Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Angular Correlation Function Estimators Accounting for Contamination from Probabilistic Distance Measurements

With the advent of surveys containing millions to billions of galaxies, it is imperative to develop analysis techniques that utilize the available statistical power. In galaxy clustering, even small sample contamination arising from distance uncertainties can lead to large artifacts, which the standard estimator for two-point correlation functions does not account for. We first introduce a formalism, termed decontamination, that corrects for sample contamination by utilizing the observed cross-correlations in the contaminated samples; this corrects any correlation function estimator for contamination. Using this formalism, we present a new estimator that uses the standard estimator to measure correlation functions in the contaminated samples but then corrects for contamination. We also introduce a weighted estimator that assigns each galaxy a weight in each redshift bin based on its probability of being in that bin. We demonstrate that these estimators effectively recover the true correlation functions and their covariance matrices. Our estimators can correct for sample contamination caused by misclassification between object types as well as photometric redshifts; they should be particularly helpful for studies of galaxy evolution and baryonic acoustic oscillations, where forward modeling the clustering signal using the contaminated redshift distribution is undesirable.

79 ASTRONOMY AND ASTROPHYSICS↗

Applications of High Resolution Laser Induced Breakdown Spectroscopy for Environmental and Biological Samples

This chapter details the application of LIBS in a number of environmental areas of research such as carbon sequestration and climate change. LIBS has also been shown to be useful in other high resolution environmental applications for example, elemental mapping and detection of metals in plant materials. LIBS has also been used in phytoremediation applications. Other biological research involves a detailed understanding of wood chemistry response to precipitation variations and also to forest fires. A cross-section of Mountain pine (pinceae Pinus pungen Lamb.) was scanned using a translational stage to determine the differences in the chemical features both before and after a fire event. Consequently, by monitoring the elemental composition pattern of a tree and by looking for abrupt changes, one can reconstruct the disturbance history of a tree and a forest. Lastly we have shown that multivariate analysis of the LIBS data is necessary to standardize the analysis and correlate to other standard laboratory techniques. LIBS along with multivariate statistical analysis makes it a very powerful technology that can be transferred from laboratory to field applications with ease.

Martin, Madhavi Z↗

Anatomical Fraction segmentation in the biomass bales

The U.S. Department of Energy Bioenergy Technologies Office (BETO) is committed to the development of sustainable, nationwide, commercial biofuel production to displace petroleum-derived fuels, increase domestic energy production, and encourage the creation of a domestic bioenergy and bioproducts industry. Operating a commercial-scale bioenergy operation requires significant technological advancements for determining biomass feedstock quality during the preprocessing stage. Usage of non-food feedstocks- e.g., corn-stover, pine residue, and forest residue - at the biorefineries reduces strain on the food supply chain. But the non-food feedstock heterogeneity- physical size, shape, and chemical composition-poses a significant challenge during milling, conveyance, feeding, and biofuel conversion processes. 3D X-Ray imaging (CT) is capable of distinguishing material features by detecting density and compositional differences. But the inherent complexity introduced during harvesting and bailing makes the reconstruction and interpretation of baled biomass materials from x-ray data time consuming, laborious, and expensive. Feedstocks are low-density materials that produce small contrast differences in the x-ray images. This paper focuses on using the shape and texture properties, using 3D image processing techniques like 3D skeletonization, directional statistics to characterize and extract volumetric content of the different tissue samples in the biomass bales.

09 BIOMASS FUELS↗

Understanding Manufacturing Scale-Up of Plasma Sprayed Zr Barrier Coatings on U-10Mo Fuels

The United States government is committed to further strengthening nuclear security and nonproliferation in order to reduce the threat of terrorists acquiring nuclear material. To meet this important mission, the US Department of Energy/National Nuclear Security Agency's Office of Material Management and Minimization (M{sup 3}) Reactor Conversion Program minimizes the use of highly enriched uranium (HEU) in civilian applications by working with governments and facilities around the world to convert research reactors to the use of non-weapons-usable low-enriched uranium (LEU) fuels. Each reactor converted not only eliminates the need for HEU at civilian sites, but also reduces the amount of HEU being manufactured, stored, and transported, where it is at its most vulnerable. In instances where suitable LEU fuels do not exist for particular reactors to convert, the M{sup 3} Reactor Conversion Program (CONVERT) contributes to the development of new LEU fuels. Currently, the M{sup 3} Reactor Conversion Program is committed to developing a high-density U-Mo LEU fuel that will be able to convert high performance research reactors while establishing an efficient and economic fabrication capability to make the fuel. To that end, Los Alamos National Laboratory (LANL) has been tasked with developing a method to affix a Zirconium fuel diffusion barrier via plasma spraying that will prevent a reaction between the U-Mo fuel and the aluminum cladding. This report discusses the transitions from development of the plasma spray deposition process to a scientific understanding of pseudo-production conditions and quantification of coating layer properties, characterization, reproducibility, etc. Understanding quality assurance and its applications to experiment work is non-trivial; statistical analysis of various measurement techniques not only improve quality, but will allow for scale up of manufacturing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capturing dynamics on multiple timescales: a hybrid approach for cluttered electromagnetic data

Many problems in electromagnetic signal analysis exhibit dynamics on a wide range of time scales against nonstationary clutter and noise. We consider a problem in which the relevant time scales can range from nanoseconds to hours or days (12 or 13 orders of magnitude). We present a hybrid algorithm currently designed to capture the dynamic behavior at scales from nanoseconds to milliseconds (6 orders of magnitude) while remaining robust to clutter and noise. We draw from techniques of adaptive feature extraction, statistical machine learning, and discrete process modeling and present results on a simulated multimode problem. Our goals are to find a representation of the signal that allows us to identify which pulses were produced by a target emitter and to determine the operational mode of the target.

97 MATHEMATICS AND COMPUTING↗

A statistical method for retrospective cardiac and respiratory motion gating of interventional cardiac x-ray images

Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy. Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique. The principal component analysis (PCA) statistical method is used in combination with other image processing operations to make our proposed masked-PCA technique suitable for cardiorespiratory gating. Unlike many previously proposed techniques, our technique is robust to varying image-content, thus it does not require specific catheters or any other optically opaque structures to be visible. Therefore, it works without any knowledge of catheter geometry. The authors demonstrate the application of our technique for the purposes of retrospective cardiorespiratory gating of normal and very low dose x-ray fluoroscopy images. Results: For normal dose x-ray images, the algorithm was validated using 28 clinical electrophysiology x-ray fluoroscopy sequences (2168 frames), from patients who underwent radiofrequency ablation (RFA) procedures for the treatment of atrial fibrillation and cardiac resynchronization therapy procedures for heart failure. The authors established end-systole, end-expiration, and end-inspiration success rates of 97.0%, 97.9%, and 97.0%, respectively. For very low dose applications, the technique was tested on ten x-ray sequences from the RFA procedures with added noise at signal to noise ratio (SNR) values of√(5)0, √(1)0, √(8), √(6), √(5), √(2), and √(1) to simulate the image quality of increasingly lower dose x-ray images. Even at the low SNR value of √(2), representing a dose reduction of more than 25 times, gating success rates of 89.1%, 88.8%, and 86.8% were established. Conclusions: The proposed technique can therefore extract useful information from interventional x-ray images while minimizing exposure to ionizing radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization Studies of Radiation Shielding for the PIP-II Project at Fermilab

The PIP-II project at Fermilab, which includes an 800-MeV superconducting LINAC, demands rigorous radiation shielding optimization to meet safety requirements. We updated the MARS geometry model to reflect new magnet and collimator designs and introduced high-resolution detector planes to better capture radiation field distributions. To overcome the significant computational demands, we implemented a well-known branching technique that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through particle splitting and the application of Russian Roulette techniques. Additionally, new graphical tools were created to streamline data visualization and MARS code usability.

Makovec, Alajos [Fermilab] (ORCID:0000000286157492↗

Dosimetric Comparison of RapidArc with Fixed Gantry Intensity-Modulated Radiotherapy Treatment for Multiple Liver Metastases Radiotherapy

We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and fixed gantry intensity-modulated radiotherapy treatment (IMRT) for multiple liver metastases. Computed tomography datasets of 10 patients were studied retrospectively. IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose distribution of planning target volume (PTV), organs at risk (OARs), and the normal tissue were compared. Monitor units and treatment time were scored to measure expected treatment efficiency. Both RapidArc and IMRT plans resulted in equivalent target coverage. There was no statistically significant difference for the maximum and the minimum dose of PTV. RapidArc plans achieved an improved conformity index compared with IMRT (RA1 = 1.68 {+-} 0.27, RA2 = 1.61 {+-} 0.25, IMRT = 1.80 {+-} 0.37). For OARs, all techniques respected planning objectives. RapidArc plans had a lower dose in V{sub 40} of small bowel than IMRT, but were higher in mean dose of kidneys. Concerning the V{sub 5}, V{sub 10}, and V{sub 15} of healthy tissue, RapidArc plans were higher than IMRT. However, the V{sub 20}, V{sub 25}, and V{sub 30} of healthy tissue in RapidArc plans were lower than IMRT. Monitor units per fraction of RapidArc plans were about 40% or 46% of IMRT. Compared with IMRT plans, treatment time of RapidArc plans were reduced by 60% or 70%. All techniques respected planning objectives. RapidArc showed statistical improvements in conformity index and healthy tissue sparing with uncompromised target coverage. This, in combination with fewer monitor units and short delivery time, can lead to clinically significant advances for the treatment of multiple liver metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction of Dual-PRF Doppler Velocity Outliers in the Presence of Aliasing

Abstract In Doppler weather radars, the presence of unfolding errors or outliers is a well-known quality issue for radial velocity fields estimated using the dual–pulse repetition frequency (PRF) technique. Postprocessing methods have been developed to correct dual-PRF outliers, but these need prior application of a dealiasing algorithm for an adequate correction. This paper presents an alternative procedure based on circular statistics that corrects dual-PRF errors in the presence of extended Nyquist aliasing. The correction potential of the proposed method is quantitatively tested by means of velocity field simulations and is exemplified in the application to real cases, including severe storm events. The comparison with two other existing correction methods indicates an improved performance in the correction of clustered outliers. The technique proposed is well suited for real-time applications requiring high-quality Doppler radar velocity fields, such as wind shear and mesocyclone detection algorithms, or assimilation in numerical weather prediction models.

58 GEOSCIENCES↗

A Parameter-masked Mock Data Challenge for Beyond-two-point Galaxy Clustering Statistics

The past few years have seen the emergence of a wide array of novel techniques for analyzing high-precision data from upcoming galaxy surveys, which aim to extend the statistical analysis of galaxy clustering data beyond the linear regime and the canonical two-point (2pt) statistics. We test and benchmark some of these new techniques in a community data challenge named “Beyond-2pt,” initiated during the Aspen 2022 Summer Program “Large-Scale Structure Cosmology beyond 2-Point Statistics,” whose first round of results we present here. The challenge data set consists of high-precision mock galaxy catalogs for clustering in real space, in redshift space, and on a light cone. Participants in the challenge have developed end-to-end pipelines to analyze mock catalogs and extract unknown (“masked”) cosmological parameters of the underlying ΛCDM models with their methods. The methods represented are density-split clustering, nearest neighbor statistics, BACCO power spectrum emulator, void statistics, LEFTfield field-level inference using effective field theory (EFT), and joint power spectrum and bispectrum analyses using both EFT and simulation-based inference. In this work, we review the results of the challenge, focusing on problems solved, lessons learned, and future research needed to perfect the emerging beyond-2pt approaches. The unbiased parameter recovery demonstrated in this challenge by multiple statistics and the associated modeling and inference frameworks supports the credibility of cosmology constraints from these methods. The challenge data set is publicly available, and we welcome future submissions from methods that are not yet represented.

Krause, Elisabeth [Univ. of Arizona, Tucson, AZ (U↗

An optimized posterior axillary boost technique in radiation therapy to supraclavicular and axillary lymph nodes: A comparative study

To assess the advantages of an optimized posterior axillary (AX) boost technique for the irradiation of supraclavicular (SC) and AX lymph nodes. Five techniques for the treatment of SC and levels I, II, and III AX lymph nodes were evaluated for 10 patients selected at random: a direct anterior field (AP); an anterior to posterior parallel pair (AP-PA); an anterior field with a posterior axillary boost (PAB); an anterior field with an anterior axillary boost (AAB); and an optimized PAB technique (OptPAB). The target coverage, hot spots, irradiated volume, and dose to organs at risk were evaluated and a statistical analysis comparison was performed. The AP technique delivered insufficient dose to the deeper AX nodes. The AP-PA technique produced larger irradiated volumes and higher mean lung doses than the other techniques. The PAB and AAB techniques originated excessive hot spots in most of the cases. The OptPAB technique produced moderate hot spots while maintaining a similar planning target volume (PTV) coverage, irradiated volume, and dose to organs at risk. This optimized technique combines the advantages of the PAB and AP-PA techniques, with moderate hot spots, sufficient target coverage, and adequate sparing of normal tissues. The presented technique is simple, fast, and easy to implement in routine clinical practice and is superior to the techniques historically used for the treatment of SC and AX lymph nodes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decoding defect statistics from diffractograms via machine learning

Abstract Diffraction techniques can powerfully and nondestructively probe materials while maintaining high resolution in both space and time. Unfortunately, these characterizations have been limited and sometimes even erroneous due to the difficulty of decoding the desired material information from features of the diffractograms. Currently, these features are identified non-comprehensively via human intuition, so the resulting models can only predict a subset of the available structural information. In the present work we show (i) how to compute machine-identified features that fully summarize a diffractogram and (ii) how to employ machine learning to reliably connect these features to an expanded set of structural statistics. To exemplify this framework, we assessed virtual electron diffractograms generated from atomistic simulations of irradiated copper. When based on machine-identified features rather than human-identified features, our machine-learning model not only predicted one-point statistics (i.e. density) but also a two-point statistic (i.e. spatial distribution) of the defect population. Hence, this work demonstrates that machine-learning models that input machine-identified features significantly advance the state of the art for accurately and robustly decoding diffractograms.

36 MATERIALS SCIENCE↗

Statistics of Fractionalized Excitations through Threshold Spectroscopy

We show that neutral anyonic excitations have a signature in spectroscopic measurements of materials: The low-energy onset of spectral functions near the threshold follows universal power laws with an exponent that depends only on the statistics of the anyons. This provides a route, using experimental techniques such as neutron scattering and tunneling spectroscopy, for detecting anyonic statistics in topologically ordered states such as gapped quantum spin liquids and hypothesized fractional Chern insulators. Our calculations also explain some recent theoretical results in spin systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a Single-Isocenter Technique for Axillary Radiotherapy in Breast Cancer

The aim of this study was to develop a technique for axillary radiotherapy that minimizes the risk of radiation-induced damage to the surrounding normal tissue (i.e., arm, shoulder, lung, esophagus, and spinal cord) while keeping the risk of a nodal recurrence to a minimum. A planning study was performed in 20 breast cancer patients. The target volume of the axillary treatment encompassed the periclavicular and axillary lymph node areas. The 3-dimensional (3D) computed tomography (CT) information in this study was used to outline the lymph node areas and the organs at risk (i.e., the esophagus, spinal cord, brachial plexus, and lung). A conventional AP-PA technique (with a transmission plate placed in the AP beam) was evaluated. In addition, a new single-isocenter technique consisting of AP/PA fields using a gantry rotation of {+-}20 deg. and a medial AP segment was developed. Both techniques were compared by evaluation of the calculated dose distributions and the dose-volume histograms of the target volume and surrounding organs at risk. The field borders and humeral shielding were redefined based on the 3D anatomical references. Adapting the humeral shielding reduced the irradiated volume by 19% and might contribute to a reduction of the incidence of arm edema and impairment of shoulder function. The maximum radiation dose in the esophagus and spinal cord was reduced by more than 50% using the single-isocenter technique. The difference between both techniques with respect to the mean doses in the target volume and lung, and the maximum dose in brachial plexus, was not statistically significant. Moreover, the single-isocenter technique allowed a fast and easy treatment preparation and reduced the execution time considerably (with approximately 10 minutes per fraction)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathways to Identity. Using Visualization to Aid Law Enforcement in Identification Tasks

The nature of identity has changed dramatically in recent years and has grown in complexity. Identities are defined in multiple domains: biological and psychological elements strongly contribute, but biographical and cyber elements also are necessary to complete the picture. Law enforcement is beginning to adjust to these changes, recognizing identity’s importance in criminal justice. The SuperIdentity project seeks to aid law enforcement officials in their identification tasks through research of techniques for discovering identity traits, generation of statistical models of identity and analysis of identity traits through visualization. We present use cases compiled through user interviews in multiple fields, including law enforcement, and describe the modeling and visualization tools design to aid in those use cases.

99 GENERAL AND MISCELLANEOUS↗

Uniform Beam Simulation Technique for Beam Scans and Machine Learning Studies at Fermilab

Fermilab's neutrino facilities, including NuMI and the upcoming LBNF, use proton beams to produce positively and negatively charged pions and kaons. Detailed simulations are necessary to study particle interactions and beam propagation. To efficiently analyze beam scan effects, we propose a technique to generate multiple simulation samples with high statistics. These samples can be used to develop beamline simulation based machine learning applications. In this technique, we generate a uniformly distributed single simulation data sample. We calculate Gaussian weights for each beam configurations and apply them to post-processing measurements. In this poster, we demonstrate the proposed simulation technique. This technique reduces simulation time and computing resources significantly.

Wickremasinghe, Athula↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Global Spray Combustion Characteristics and Local Shot-to-Shot Variations in a Reacting n -Heptane Spray

In support of efforts to develop improved models of turbulent spray behavior and combustion in diesel engines, experimental data and analysis must be obtained for guidance and validation. For Reynolds-averaged Navier–Stokes (RANS)-based Computational fluid dynamics (CFD) modeling approaches, representative ensemble average experimental results are important. For high-fidelity models such as large eddy simulations (LES)-based CFD, precise individual experimental results are desirable. However, making comparisons between a given experiment and LES is a challenge since local parameters cannot be directly compared. In this work, an optically accessible constant pressure flow rig (CPFR) is utilized to acquire diesel-like fuel injection and reaction behavior simultaneously with three optical diagnostic techniques: rainbow Schlieren deflectometry (RSD), OH* chemiluminescence (OH*), and two-color pyrometry (2CP). The CPFR allows a large number of repeated injection experiments to be performed for statistical analysis and convergence using ensemble-averaging techniques, while maintaining highly repeatable test conditions. Even for stable test conditions, variations in local turbulent fuel–air mixing introduce variability, which manifests as significant differences in OH* and 2CP results. Experimental measurements of characteristic parameters including liquid and vapor jet penetration, liftoff length, soot temperature and concentration, and turbulent flame speed, along with the shot-to-shot variability of each dataset, are presented and discussed. Finally, a statistical method is utilized to analyze the extent of this variability, and to identify superlative injections within the dataset for discussion and analysis of shot-to-shot variations.

42 ENGINEERING↗