At least 595 records · Page 33

The National Transmission Planning Study: Chapter 2: Long-Term U.S. Transmission Planning Scenarios

The National Transmission Planning Study (NTP Study) was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. The study sought to develop new national grid-scale planning tools and methods that can be used by industry, especially when planning for interregional transmission capacity needs; identify potential transmission solutions that will provide broad-scale benefits to electric customers under a wide range of potential futures; inform planning processes for regional and interregional transmission; and identify interregional and national strategies to maintain grid reliability as the grid transitions, including to a reliance on low- and zero-carbon energy resources. The NTP Study is presented as a collection of six chapters.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

The National Transmission Planning Study: Chapter 3: Transmission Portfolios and Operations for 2035 Scenarios

The National Transmission Planning Study (NTP Study) was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. The study sought to develop new national grid-scale planning tools and methods that can be used by industry, especially when planning for interregional transmission capacity needs; identify potential transmission solutions that will provide broad-scale benefits to electric customers under a wide range of potential futures; inform planning processes for regional and interregional transmission; and identify interregional and national strategies to maintain grid reliability as the grid transitions, including to a reliance on low- and zero-carbon energy resources. The NTP Study is presented as a collection of six chapters.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

The National Transmission Planning Study: Chapter 5: Stress Analysis for 2035 Scenarios

The National Transmission Planning Study (NTP Study) was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. The study sought to develop new national grid-scale planning tools and methods that can be used by industry, especially when planning for interregional transmission capacity needs; identify potential transmission solutions that will provide broad-scale benefits to electric customers under a wide range of potential futures; inform planning processes for regional and interregional transmission; and identify interregional and national strategies to maintain grid reliability as the grid transitions, including to a reliance on low- and zero-carbon energy resources. The NTP Study is presented as a collection of six chapters.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

The National Transmission Planning Study: Chapter 4: AC Power Flow Analysis for 2035 Scenarios

The National Transmission Planning Study (NTP Study) was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. The study sought to develop new national grid-scale planning tools and methods that can be used by industry, especially when planning for interregional transmission capacity needs; identify potential transmission solutions that will provide broad-scale benefits to electric customers under a wide range of potential futures; inform planning processes for regional and interregional transmission; and identify interregional and national strategies to maintain grid reliability as the grid transitions, including to a reliance on low- and zero-carbon energy resources. The NTP Study is presented as a collection of six chapters.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Mass Production of Microreactors: A Look at Potential Scenarios and Fabrication Facility Requirements

Microreactors may be able to be cost competitive in niche markets, but they are likely to be much more expensive than small modular reactors or large reactors in terms of levelized cost. The vision of microreactors being catered to larger markets relies heavily on their ability to be mass produced and cut costs. Since commercial nuclear reactors have not been mass produced before it is challenging to estimate what kind of manufacturing facilities will be needed, what they will cost, and how factory considerations influence the unit cost of microreactors. This summary attempts to imagine the various possible production layouts of microreactors and identify the different possible manufacturing facilities (factories) that might be required. Regulatory and economic considerations for these layouts and factories are then listed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid Interconnection and Renewables Deployment Related Air Quality and Human Health Benefits in Southeast Asia

The Association of Southeast Asian Nations (ASEAN) has increasingly focused on multilateral electricity trade, improved grid resiliency and modernization. These opportunities in the power sector have been studied through the ASEAN Interconnection Masterplan Studies, the most recent of which is the ASEAN Interconnection Masterplan Study III (AIMS III). AIMS III assessed four different scenarios of power system in the ASEAN countries that include a base scenario and three additional scenarios (called optimum RE, ASEAN RE, and High RE) considering different levels of deployment of renewable energy (RE) and cross-border generation and trade of electricity for three years (2025, 2030, 2040). In this work, we quantify the potential air quality and public health co-benefits of AIMS III scenarios. For a rapidly expanding, energy hungry region like SE Asia generation is power generation is expected to increase significantly. The AIMS III scenarios' capacity expansion modeling suggest that: 1) Generation nearly doubles from 2025 to 2040 in all four AIMS III scenarios; 2) Most of the increased generation is met by coal in all four AIMS III scenarios; 3) While renewables generation increases in all four AIMS III scenarios, the fraction of total generation (its share) generally decreases because of the much greater increase in non-renewable sources, mostly coal. Only in the High RE Target scenario do renewables represent a higher share in 2040 than in 2025, though even here it is at the expense of natural gas rather than coal; 4) As a result, emissions of gaseous and aerosol pollutants increase significantly in all scenarios. Because emissions increase in 2040 compared to 2025 for all four AIMS III scenarios, so do PM2.5 concentrations. Even for the High RE Target scenario (the scenario with highest share of renewable energy), compared to the Base scenario in 2025, in 2040 PM2.5 concentrations are higher. Compared to the Base scenario in the same years, the Optimum RE and ASEAN RE Target scenarios do not differ very much from the Base in terms of PM2.5 concentration. The High RE Target scenario, on the other hand, yields noticeably lower PM2.5 concentration. For example, in 2040 the population-weighted decrease in annual average PM2.5 concentration in the High RE Target scenario relative to the Base scenario is 0.5 ug m-3. Compared to the Base scenario in 2040, each of the alternative AIMS III scenarios is estimated to result in net reductions in power-sector air quality-related excess mortality in the ASEAN region. Yet there are a few countries for which the Optimum RE and ASEAN RE Target result in increases in PM2.5-related excess mortality (Thailand and Vietnam for the ASEAN RE Target scenario and Thailand for the Optimum RE scenario). However, for the High RE Target scenario, all countries benefit and find reductions in excess mortality resulting from the power sector scenarios modeled in AIMS III with regionwide mortality decreasing by 16,000 compared to the Base scenario in 2040. In summary, our analysis finds that changing power generation emissions is a crucial lever for improving public health in ASEAN member countries and provides a pathway for policymakers to make decision backed by a realistic power sector expansion and air quality analyses.

air quality↗

Projected Urban Morphology of the Los Angeles Area by the Year 2100

This dataset provides projections of urban building morphologies for the Los Angeles urban area at 30-meter spatial resolution. It contains 192 raster files that detail two primary building attributes: building footprint fractions (ranging from 0 to 1) and average building heights (ranging from 0 to 75 meters). The projections account for a wide range of future pathways, covering two Shared Socioeconomic Pathway (SSP) scenarios (SSP3 and SSP5), two population scenarios, two developed land intensification scenarios, and four distinct levels of intensification. The dataset was created using dual Generative Adversarial Networks (GANs) trained on 2015 land cover and building properties from the National Land Cover Database (NLCD) and Model America datasets. Supporting information on the dataset has been described in the LAUrbanAreaMorphologyProjections2100_README.txt file.

Pandey, Bhartendu↗

How structural differences influence cross-model consistency: An electric sector case study

Multiple models are often employed to describe a range of possible outcomes for one or more scenarios, yielding insights into causal relationships and their uncertainties. Electric sector capacity expansion scenarios are a common topic of such efforts due to the economic influence of the electric sector, but model results typically span a broad solution space despite efforts to harmonize input assumptions, making decision implications difficult to discern. This study investigates the relationship between input harmonization and cross-model scenario consistency under disparate electric sector scenarios. We compare cross-model consistency between two state-of-the-art electric sector capacity expansion models (GCAM-USA and ReEDS) for six electric sector scenarios comprising alternate assumptions about fossil fuel resource availability, technology innovation, and long-term economy-wide transitions under four harmonization configurations varying model representations of electricity demand, fuel prices, renewable resources, and capacity retirements. These comparisons reveal that cross-model consistency can vary across scenarios under a given harmonization configuration, suggesting that harmonization efforts must often be scenario-specific if comparable cross-model consistency is desired. Model structural differences can hinder consistency, and the impact of these differences can depend on the scenario. Ultimately, thorough harmonization can reveal insights into cross-model consistency, which can be used to tighten uncertainty bounds and improve the decision-making implications of multi-model activities.

Cohen, Stuart↗

Integrated GW Farm ABM

This Data Repository includes data used for the integrated groundwater- farm ABM model, raw model output from scenario ensemble, and processed outputs that isolate the groundwater storage depletion outcomes for the 35,000 farm cells. Model Inputs: Farm ABM Inputs: This folder contains the input data used by the integrated groundwater - farm ABM modelling script (Python file) used for the high performance computing (HPC) experiments. The sub-folder "data inputs" contains all of the farm attribute data, while the three files in the folder have the hydrogeological data lookup table (NLDAS Cost Curve Attributes.csv), a lookup table (Theis well function table.csv) for the groundwater cost curve function, and the farm indexes and corresponding NLDAS ids for all of the cells run in this experiment (nldas farms subset final.csv). NLDAS Cost curve hydrogeological data: Hydrogeological data aggregated to 1/8 degree resolution and aligned with the NLDAS grid. Parameters include: water depth below ground surface [meters], subsurface porosity [unitless], aquifer depth from ground surface to aquifer bottom [meters], annual average recharge (USGS: mm, Doll: meters), and three different hydraulic conductivity (K) values (meters/day). The three K values represent the mean value from Gleeson et al. (2018), one standard deviation above the mean from Gleeson et al. (2018), and the de Graaf et al. 2020 modifications to certain lithologies. Additional information about these datasets and their processing are documented in the supplement to Yoon et al. 2025 (in review). Output: Raw outputs: This folder contains a .zip file that has model outputs for the entire scenario ensemble. There is one csv for each farm id, using the format "farm farmid cases.csv". The relationship between the farm id and NLDAS id is defined by the "nldas farms subset final.csv" located in the Farm ABM Inputs folder. Each csv has 625 rows, corresponding to 625 combinations of different scenario parameter values. Each row (scenario) represents the outcome of a 100 year simulation. Columns define scenario settings and summary statistics for each scenario. The first four columns define the scenario settings: "hydro ratio," "econ ratio," "K scenario," and "gamma scenario." The hydro and econ ratios are values passed to the modeling script that influence multipliers for other model parameters, as documented in the supplement to Yoon et al. 2025 (in review). The gamma multiplier is a coefficient multiplier applied to the baseline gamma values (values below 1 represent lower unobserved costs compared to baseline, values above 1 represent higher costs). The K scenario names represent K values of: "low": 0.5 m/d, "int 1": 2.5 m/d, "int 2": 10 m/d, "high": 50 m/d, and "gleeson": mean Gleeson K value. "Perc vol depleted" is the fraction of groundwater depleted at the end of the 100 simulation. Processed Output: Derived depletion outcomes from raw outputs: All of the individual csv files from the Raw outputs were aggregated into a single file that has the scenario settings and fraction depletion "Perc vol depleted" for every farm cell, for every scenario. The other two files define relationships between the farm id, NLDAS id, and local and major aquifer units, used for aquifer-level depletion analysis.

Agent based modeling↗

A heuristic tool to assess regional impacts of renewable energy infrastructure on conservation areas

Wind and hydropower are important renewable components of national energy portfolios, but their infrastructure negatively affects biodiversity. Regional development requires identification of scenarios that minimize the cumulative impacts of multiple facilities. We introduce the cumulative impact plot (CIP) to quantify cumulative impacts of renewable energy development within a region. Summed impacts of facilities are plotted as a function of the number of facilities, with facilities ranked by increasing (the best-case scenario) or decreasing (worst-case scenario) individual impact. These curves represent lower and upper bounds to which alternative development scenarios (e.g., facilities ranked by generating capacity) can be compared. We used CIPs to assess overlap of potential wind and hydropower facilities with two types of conservation area in the United States: (1) federally protected lands and (2) critical habitats of federally threatened and endangered species. Here, we evaluated two alternative scenarios: facilities ranked by (A) decreasing generating capacity and (B) increasing distance from urban centers. Differences between the best-case and worst-case scenarios were large, thus revealing opportunities to develop facilities with limited impact on conservation areas. Alternative scenarios maximizing energy density generally resulted in conservation area overlap intermediate to best-case and worst-case scenarios. CIPs can also identify the proportion of wind versus hydropower favored under alternative scenarios. Build-out scenarios aimed at minimizing conservation area overlap favor hydropower, whereas alternative scenarios favor wind power. We conclude that CIPs can (1) complement—but should not replace—project-level environmental impact assessment, (2) integrate strategic, cumulative, and scenario-based assessments, and (3) harness rapidly growing geospatial data.

54 ENVIRONMENTAL SCIENCES↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Ectomycorrhizal effects on decomposition are highly dependent on fungal traits, climate, and litter properties: A model-based assessment. Dataset.

To simulate the effects of mycorrhizal fungi on soil organic matter cycling, we incorporated mycorrhizal processes into the Carbon, Organisms, Rhizosphere, and Protection in the Soil Environment (CORPSE) model to develop a new soil model Myco-CORPSE. The new model was calibrated and evaluated against soil measurements taken at temperate forests in New Hampshire (NH) and Georgia (GA). A series of scenario analysis were also conducted to explore the conditions under which ectomycorrhizal (ECM) N acquisition processes can induce different soil C accumulation in ECM systems compared to arbuscular (AM) systems.In this data package, we included:-The Python codes of the standard Myco-CORPSE model we developed: "Standard Myco_CORPSE python codes.zip". The main program is the "gradient_sim.py" which calculates the bulk soil microbes and CN content along a user defined gradient of clay, soil temperature, soil moisture and mycorrhizal dominance, and relies on two subprograms "CORPSE_deriv.py" and "CORPSE_integrate.py". "CORPSE_deriv.py" calculated the changes in all simulated soil stock within every time step and "CORPSE_integrate.py" integrate the changes in all simulated soil stock within simulated time period. The program "Plot.py" is used to plot the major outputs produced by the main program "gradient_sim.py".-The modified Python codes of Myco-CORPSE models with site-level environmental inputs (in NH and GA) used to conduct simulations in NH and GA sites: "NH_GA model simulations.zip". -The Python codes used to evaluate the Myco-CORPSE simulation outputs in NH and GA sites against site-level measurements: "Plot NH_GA simulation against measurements.zip". It includes both the evaluation Python code, the model outputs on NH and GA sites, and the measured soil properties in both sites.-The modified Python codes of Myco-CORPSE models "Scenario analysis_model simulations.zip" that is used to conduct scenario analysis of how different litter properties, mycorrhizal fungal traits, climate, and seasonal variation in temperature and vegetation phenology impact the mycorrhizal effects on soil CN properties. The sub file folder "Scenario analysis_litter traits" contains the codes for scenario analysis of different litter properties; The sub file folder "Scenario analysis_ECM types" contains the codes for scenario analysis of different ECM fungal traits; The sub file folder "Scenario analysis_climate&seasonality" contains the codes for scenario analysis of different climate and seasonalities;-"Scenario analysis_model results and plotting codes.zip" contains all the output files from the the scenario analysis of Myco-CORPSE model as described above and the plotting codes used to the generate the heatmaps and scatterplots shown in the manuscript "Ectomycorrhizal effects on decomposition are highly dependent on fungal traits, climate, and litter properties: A model-based assessment"The majority of the model outputs did not have specific geographic information or temporal coverage because the analysis we conducted are mainly hypothetical model simulations. We only provided geographic description, coordinates and temporal coverage for those soil measurements which we used for model evaluations (included in the "Plot NH_GA simulation against measurements.zip").

54 ENVIRONMENTAL SCIENCES↗