Dealloying of Cu (3) Pt(111) Studied by Surface X-ray Scattering Surface X-Ray Scattering
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In nondestructive testing (NDT) and medical diagnostic x-ray imaging (photon energy<140 keV), scattered x-ray caused by Compton and Rayleigh scattering should be eliminated. Scattered x-ray photons reduce image contrast, increase image noise, and introduce artifact into the reconstructed computed tomography (CT) images. In cone-beam CT, where the coverage of the x-ray beam and the area of the detector are significantly larger than those in fan-beam CT, x-ray photon scatter is one of the major sources of image degradation. The artifacts caused by scattered x-ray photon can be divided into two categories: 1) low spatial frequency scatter profile adds a positive bias to the detected radiation signal, thus reducing the effective attenuation of the imaged object, resulting in a negative bias in the measured linear attenuation coefficient in the image; 2) a high spatial frequency scatter profile causes a differential artifact, such as shading in uniform regions. A real x-ray scan is composed of both low and high frequency scatter profiles. Thus, the key to a successful scatter correction is the ability to accurately capture the scatter profile of a real x-ray imaging scan. The most accurate method for estimating a scatter profile is the Monte Carlo simulation. However, the computation cost of the Monte Carlo method makes it unfeasible for simulating real and complex scan geometries in clinical settings. A practical yet accurate scatter profile estimation method is through ray tracing techniques, where the scatter profiles are computed by tracking rays through the object's volume. The x-ray from the source is tracked when it interacts with the material in the volume. The interaction creates scattered x-rays, in all possible directions. These rays are again either attenuated or scattered, creating cascaded scatter events. In x-ray CT, the first-order scattering (where only one scatter interaction is encountered) accounts for the most severe image artifacts since this first-order scatter contains a high frequency component of the scatter profile. Previous studies have shown that ray tracing techniques are quite effective in simulating the contribution of first-order scattering in radiological images. In this study, a similar ray tracing technique is applied to simulate the scatter profile of a real x-ray computed tomography (CT) scan in clinical settings. A good agreement has been found between the simulated scatter profile and the experimental measurement result. (authors)
Purpose: Small calcifications are often the earliest and the main indicator of breast cancer. Dual-energy digital mammography (DEDM) has been considered as a promising technique to improve the detectability of calcifications since it can be used to suppress the contrast between adipose and glandular tissues of the breast. X-ray scatter leads to erroneous calculations of the DEDM image. Although the pinhole-array interpolation method can estimate scattered radiations, it requires extra exposures to measure the scatter and apply the correction. The purpose of this work is to design an algorithmic method for scatter correction in DEDM without extra exposures.Methods: In this paper, a scatter correction method for DEDM was developed based on the knowledge that scattered radiation has small spatial variation and that the majority of pixels in a mammogram are noncalcification pixels. The scatter fraction was estimated in the DEDM calculation and the measured scatter fraction was used to remove scatter from the image. The scatter correction method was implemented on a commercial full-field digital mammography system with breast tissue equivalent phantom and calcification phantom. The authors also implemented the pinhole-array interpolation scatter correction method on the system. Phantom results for both methods are presented and discussed. The authors compared the background DE calcification signals and the contrast-to-noise ratio (CNR) of calcifications in the three DE calcification images: image without scatter correction, image with scatter correction using pinhole-array interpolation method, and image with scatter correction using the authors' algorithmic method.Results: The authors' results show that the resultant background DE calcification signal can be reduced. The root-mean-square of background DE calcification signal of 1962 μm with scatter-uncorrected data was reduced to 194 μm after scatter correction using the authors' algorithmic method. The range of background DE calcification signals using scatter-uncorrected data was reduced by 58% with scatter-corrected data by algorithmic method. With the scatter-correction algorithm and denoising, the minimum visible calcification size can be reduced from 380 to 280 μm.Conclusions: When applying the proposed algorithmic scatter correction to images, the resultant background DE calcification signals can be reduced and the CNR of calcifications can be improved. This method has similar or even better performance than pinhole-array interpolation method in scatter correction for DEDM; moreover, this method is convenient and requires no extra exposure to the patient. Although the proposed scatter correction method is effective, it is validated by a 5-cm-thick phantom with calcifications and homogeneous background. The method should be tested on structured backgrounds to more accurately gauge effectiveness.
Purpose: X-ray scatter is a source of significant image quality loss in cone-beam computed tomography (CBCT). The use of Monte Carlo (MC) simulations separating primary and scattered photons has allowed the structure and nature of the scatter distribution in CBCT to become better elucidated. This work seeks to quantify the structure and determine a suitable basis function for the scatter distribution by examining its spectral components using Fourier analysis.Methods: The scatter distribution projection data were simulated using a CBCT MC model based on the EGSnrc code. CBCT projection data, with separated primary and scatter signal, were generated for a 30.6 cm diameter water cylinder [single angle projection with varying axis-to-detector distance (ADD) and bowtie filters] and two anthropomorphic phantoms (head and pelvis, 360 projections sampled every 1°, with and without a compensator). The Fourier transform of the resulting scatter distributions was computed and analyzed both qualitatively and quantitatively. A novel metric called the scatter frequency width (SFW) is introduced to determine the scatter distribution's frequency content. The frequency content results are used to determine a set basis functions, consisting of low-frequency sine and cosine functions, to fit and denoise the scatter distribution generated from MC simulations using a reduced number of photons and projections. The signal recovery is implemented using Fourier filtering (low-pass Butterworth filter) and interpolation. Estimates of the scatter distribution are used to correct and reconstruct simulated projections.Results: The spatial and angular frequencies are contained within a maximum frequency of 0.1 cm{sup −1} and 7/(2π) rad{sup −1} for the imaging scenarios examined, with these values varying depending on the object and imaging setup (e.g., ADD and compensator). These data indicate spatial and angular sampling every 5 cm and π/7 rad (∼25°) can be used to properly capture the scatter distribution, with reduced sampling possible depending on the imaging scenario. Using a low-pass Butterworth filter, tuned with the SFW values, to denoise the scatter projection data generated from MC simulations using 10{sup 6} photons resulted in an error reduction of greater than 85% for the estimating scatter in single and multiple projections. Analysis showed that the use of a compensator helped reduce the error in estimating the scatter distribution from limited photon simulations by more than 37% when compared to the case without a compensator for the head and pelvis phantoms. Reconstructions of simulated head phantom projections corrected by the filtered and interpolated scatter estimates showed improvements in overall image quality.Conclusions: The spatial frequency content of the scatter distribution in CBCT is found to be contained within the low frequency domain. The frequency content is modulated both by object and imaging parameters (ADD and compensator). The low-frequency nature of the scatter distribution allows for a limited set of sine and cosine basis functions to be used to accurately represent the scatter signal in the presence of noise and reduced data sampling decreasing MC based scatter estimation time. Compensator induced modulation of the scatter distribution reduces the frequency content and improves the fitting results.
Purpose: The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for {sup 99m}Tc/{sup 123}I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). Methods: A tailing model was developed to account for the low energy tail effects of the CZT detector. The parameters of the model were obtained using {sup 99m}Tc and {sup 123}I point source measurements. A scatter model was defined to characterize the relationship between down-scatter and self-scatter projections. The parameters for this model were obtained from Monte Carlo simulation using SIMIND. The tailing and scatter models were further incorporated into a projection count model, and the primary and self-scatter projections of each radionuclide were determined with a maximum likelihood expectation maximization (MLEM) iterative estimation approach. The extracted scatter and crosstalk projections were then incorporated into MLEM image reconstruction as an additive term in forward projection to obtain scatter- and crosstalk-corrected images. The proposed method was validated using Monte Carlo simulation, line source experiment, anthropomorphic torso phantom studies, and patient studies. The performance of the proposed method was also compared to that obtained with the conventional TEW method. Results: Monte Carlo simulations and line source experiment demonstrated that the TEW method overestimated scatter while their proposed method provided more accurate scatter estimation by considering the low energy tail effect. In the phantom study, improved defect contrasts were observed with both correction methods compared to no correction, especially for the images of {sup 99m}Tc in dual-radionuclide imaging where there is heavy contamination from {sup 123}I. In this case, the nontransmural defect contrast was improved from 0.39 to 0.47 with the TEW method and to 0.51 with their proposed method and the transmural defect contrast was improved from 0.62 to 0.74 with the TEW method and to 0.73 with their proposed method. In the patient study, the proposed method provided higher myocardium-to-blood pool contrast than that of the TEW method. Similar to the phantom experiment, the improvement was the most substantial for the images of {sup 99m}Tc in dual-radionuclide imaging. In this case, the myocardium-to-blood pool ratio was improved from 7.0 to 38.3 with the TEW method and to 63.6 with their proposed method. Compared to the TEW method, the proposed method also provided higher count levels in the reconstructed images in both phantom and patient studies, indicating reduced overestimation of scatter. Using the proposed method, consistent reconstruction results were obtained for both single-radionuclide data with scatter correction and dual-radionuclide data with scatter and crosstalk corrections, in both phantom and human studies. Conclusions: The authors demonstrate that the TEW method leads to overestimation in scatter and crosstalk for the CZT-based imaging system while the proposed scatter and crosstalk correction method can provide more accurate self-scatter and down-scatter estimations for quantitative single-radionuclide and dual-radionuclide imaging.
The origins of side scattering from a fibroblast and cervical cell line were determined by comparing side-scatter images with images stained for lysosomes, nuclei, and mitochondria on a cell by cell basis. Lysosomes or nuclei are the most efficient type of scatterer depending on the cell type and incident light polarization. The relative scattering efficiencies of lysosomes and mitochondria were the same for both cell lines, while the scattering efficiencies of the nuclei differed. The percent of 90° scattering from the nucleus, mitochondria, and lysosomes as well as the group of other internal cellular objects was estimated. The nucleus was the largest contributor to side scatter in the cervical carcinoma cells. The contributions of lysosomes, mitochondria, the nucleus, and particles unstained by either Hoechst, LysoSensor or MitoTracker ranges from ~20% to ~30% in fibroblast cells. The contribution of lysosomes to side scatter was much stronger when the incident light was polarized perpendicular to the scattering plane than when the polarization of the side scatter laser was parallel to the scattering plane. This dependence on side scatter polarization indicates that lysosomes contain scattering structures that are much smaller than the wavelength of light used in the measurements (785 nm). In conclusion, mitochondria were not found to be either the most efficient scatterer or to have the largest contribution to scattering in either cell line, in contrast to previous reports. Rather lysosomes, nuclei and unknown particles all have significant contributions to 90° scattering and the contributions of some of these particles can be modulated by changing the polarization of the incident light.
Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.
The potential importance of longwave (LW) cloud scattering has been recognized but the actual estimate of this effect on thermal radiation varies greatly among different studies. General circulation models (GCMs) generally neglect or simplify the multiple scattering in the LW. In this study, we use a rigorous radiative transfer algorithm to explicitly consider LW multiple-scattering and apply the GCM to quantify the impact of cloud LW scattering on thermal radiation fluxes. Our study shows that the cloud scattering effect on downward thermal radiation at the surface is concentrated in the infrared atmospheric window spectrum (800–1250 cm9exp −1)). The scattering effect on the outgoing longwave radiation (OLR) is also present in the window region over low clouds but it is mainly in the far-infrared spectrum (300–600 cm(exp −1)) over high clouds. For clouds with small to moderate optical depth (τ < 10), the scattering effect on thermal fluxes shows large variation with the cloud τ and has a maximum at an optical depth of ∼3. For opaque clouds, the scattering effect approaches an asymptote and is smaller and less important. The 2-stream radiative transfer scheme could have an error over 10% with an RMS error around 3.5%–4.0% in the calculated LW flux. This algorithm error of the 2-stream approximation could readily exceed the no-scattering error in the LW, and thus it is worthless to include the time-consuming computation of multiple scattering in a 2-stream radiative transfer scheme. However, the calculation error rapidly decreases as stream number increases and the RMS error in LW flux using the 4-stream scheme is under 0.3%, an accuracy sufficient for most climate studies. We implement the 4-stream discrete-ordinate algorithm in the GISS GCM and run the GCM for 20 years with and without the LW scattering effect, respectively. When cloud LW scattering is included, we find that the global annual mean OLR is reduced by 2.7 W/m(exp 2), and the downward surface flux and the net atmospheric absorption are increased by 1.6 W/m2 and 1.8 W/m(exp 2), respectively. Using one year of ISCCP clouds and running the standalone radiative transfer offline, the global annual mean non-scattering errors in OLR, surface LW downward flux and net atmospheric absorption are 3.6 W/m(exp 2), −1.1 W/m(exp 2), and −2.5 W/m(exp 2), respectively. The global scattering impact of 2.7 W/m(exp 2) on the OLR is small when compared to the typical global OLR value of 240 W/m2, but it is significant when compared to cloud LW radiative forcing (30 W/m2) and net cloud forcing (−14 W/m(exp 2)). Overall, the effect of neglecting scattering on the thermal fluxes is comparable to the reported clear sky radiative effect of doubling CO2.
Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient tail information and therefore improve the accuracy of scatter estimation.
Phonon scattering plays a central role in the quantum theory of phonon linewidth, which in turn governs important properties including infrared spectra, Raman spectra, lattice thermal conductivity, thermal radiative properties, and also signifi- cantly affects other important processes such as hot electron relaxation. Since Maradudin and Fein’s classic work in 1962, three-phonon scattering had been considered as the dominant intrinsic phonon scattering mechanism and has seen tremendous advances. However, the role of the higher-order four-phonon scattering had been persistently unclear and so was ignored. The tremendous complexity of the formalism and computational challenges stood in the way, prohibiting the direct and quantitative treatment of four-phonon scattering. In 2016, a rigorous four-phonon scattering formalism was developed, and the prediction was realized using empirical potentials. In 2017, the method was extended using first-principles calculated force constants, and the thermal conductivities of boron arsenides (BAs), Si and diamond were predicted. The predictions for BAs were later confirmed by several independent experiments. Four-phonon scattering has since been investigated in a range of materials and established as an important intrinsic scattering mechanism for thermal transport and radiative properties. Specifically, four-phonon scattering is important when the fourth-order scattering potential or phase space becomes relatively large. The former scenario includes: (i) nearly all materials when the temperature is high; (ii) strongly anharmonic (low thermal conductivity) materials, including most rocksalt compounds, halides, hydrides, chalcogenides and oxides. The latter scenario includes: (iii) materials with large acoustic–optical phonon band gaps, such as XY compounds with a large atomic mass ratio between X and Y; (iv) two- dimensional materials with reflection symmetry, such as single-layer graphene, single-layer boron nitride and carbon nanotubes; and (v) phonons with a large density of states, such as optical phonons, which are important for Raman, infrared and thermal radiative properties. Four-phonon scattering is expected to gain broad interest in various technologically important materials for thermoelectrics, thermal barrier coatings, thermal energy storage, phase change, nuclear power, ultra-high temperature ceramics, infrared spectra, Raman spectra, radiative transport, hot electron relaxation and radiative cooling. Four-phonon scattering has been, and will continue to be, established as an important intrinsic phonon scattering mechanism beyond three-phonon scattering. The prediction of four-phonon scattering will transition from a breakthrough to a new routine in the next decade.
Two simple scattering mechanisms are fitted to polarimetric synthetic aperture radar (SAR) observations of forests. The mechanisms are canopy scatter from a reciprocal medium with azimuthal symmetry and a ground scatter term that can represent double-bounce scatter from a pair of orthogonal surfaces with different dielectric constants or Bragg scatter from a moderately rough surface, which is seen through a layer of vertically oriented scatterers. The model is shown to represent the behavior of polarimetric backscatter from a tropical forest and two temperate forest sites by applying it to data from the National Aeronautic and Space Agency/Jet Propulsion Laboratory's Airborne SAR (AIRSAR) system. Scattering contributions from the two basic scattering mechanisms are estimated for clusters of pixels in polarimetric SAR images. The solution involves the estimation of four parameters from four separate equations. This model fit approach is justified as a simplification of more complicated scattering models, which require many inputs to solve the forward scattering problem. The model is used to develop an understanding of the ground-trunk double-bounce scattering that is present in the data, which is seen to vary considerably as a function of incidence angle. Two parameters in the model fit appear to exhibit sensitivity to vegetation canopy structure, which is worth further exploration. Results from the model fit for the ground scattering term are compared with estimates from a forward model and shown to be in good agreement. The behavior of the scattering from the ground-trunk interaction is consistent with the presence of a pseudo-Brewster angle effect for the air-trunk scattering interface. If the Brewster angle is known, it is possible to directly estimate the real part of the dielectric constant of the trunks, a key variable in forward modeling of backscatter from forests. It is also shown how, with a priori knowledge of the forest height, an estimate for the attenuation coefficient of the canopy can be obtained directly from the multi-incidence-angle polarimetric observations. This attenuation coefficient is another key variable in forward models and is generally related to the canopy density.
Abstract Molecular beam experiments in which gas molecules are scattered from liquids provide detailed, microscopic perspectives on the gas–liquid interface. Extending these methods to volatile liquids while maintaining the ability to measure product energy and angular distributions presents a significant challenge. The incorporation of flat liquid jets into molecular beam scattering experiments in our laboratory has allowed us to demonstrate their utility in uncovering dynamics in this complex chemical environment. Here, we summarize recent work on the evaporation and scattering of Ne, CD 4 , ND 3 , and D 2 O from a dodecane flat liquid jet and present first results on the evaporation and scattering of Ar from a cold salty water jet. In the evaporation experiments, Maxwell–Boltzmann flux distributions with a cos θ angular distribution are observed. Scattering experiments reveal both impulsive scattering (IS) and trapping followed by thermal desorption (TD). Super‐specular scattering is observed for all four species scattered from dodecane and is attributed to anisotropic momentum transfer to the liquid surface. In the IS channel, rotational excitation of the polyatomic scatterers is a significant energy sink, and these species accommodate more readily on the dodecane surface compared to Ne. Our preliminary results on cold salty water jets suggest that Ar atoms undergo some vapor‐phase collisions when evaporating from the liquid surface. Initial scattering experiments characterize the mechanisms of Ar interacting with an aqueous jet, allowing for comparison to dodecane systems. Key Points Molecular beam scattering from flat liquid jets is a powerful technique to elucidate mechanistic detail at the gas–liquid interface. Previous dodecane scattering experiments have uncovered angularly‐resolved thermal desorption fractions and energy transfer at the interface for several small molecule scatterers. Preliminary results on scattering from cold salty water reveal mechanisms of interaction between argon and an aqueous jet.
Electromagnetic (EM) beams with orbital angular momentum (OAM) may have great potential applications in communication technology and in remote sensing of the Earth-atmosphere system and outer planets. Study of their interaction with optical lenses and dielectric or metallic objects, or scattering of them by particles in the Earth-atmosphere system, is a necessary step to explore the advantage of the OAM EM beams. In this study, the 3-dimensional (3D) scattered-field (SF) finite-difference time domain (FDTD) technique with the convolutional perfectly matched layer (CPML) absorbing boundary conditions (ABC) is applied to calculate the scattering of the purely azimuthal (the radial mode number is assumed to be zero) Laguerre–Gaussian (LG) beams with the OAM by dielectric particles. We found that for OAM beam׳s interaction with dielectric particles, the forward-scattering peak in the conventional phase function (P11) disappears, and light scattering peak occurs at a scattering angle of ~15° to 45°. The disappearance of forward-scattering peak means that, in laser communications most of the particle-scattered noise cannot enter the receiver, thus the received light is optimally the original OAM-encoded signal. This feature of the OAM beam also implies that in lidar remote sensing of the atmospheric particulates, most of the multiple-scattering energy will be off lidar sensors, and this may result in an accurate profiling of particle layers in the atmosphere or in the oceans by lidar, or even in the ground when a ground penetration radar (GPR) with the OAM is applied. This far-field characteristics of the scattered OAM light also imply that the optical theorem, which is derived from plane-parallel wave scattering case and relates the forward scattering amplitude to the total cross section of the scatterer, is invalid for the scattering of OAM beams by dielectric particles.
The modulated scatterer technique (MST) has shown promise for applications in microwave imaging, electric field mapping, and materials characterization. Traditionally, MST scatterers are dipoles centrally loaded with an element capable of modulation (e.g., a p-i-n diode). By modulating the load element, signals scattered from the MST scatterer are also modulated. However, due to the small size of such scatterers, it can be difficult to reliably detect the modulated signal. Increasing the modulation depth (MD; a parameter related to how well the scatterer modulates the scattered signal) may improve the detectability of the scattered signal. In an effort to improve the MD, the concept of electrically invisible antennas is applied to the design of MST scatterers. Our paper presents simulations and measurements of MST scatterers that have been designed to be electrically invisible during the reverse bias state of the modulated element (a p-i-n diode in this case), while producing detectable scattering during the forward bias state (i.e., operate in an electrically visible state). Furthermore, the results using the new design show significant improvement to the MD of the scattered signal as compared with a traditional MST scatterer (i.e., dipole centrally loaded with a p-i-n diode).