Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

NASA Curation Preparation for Ryugu Sample Returned by JAXA's Hayabusa2 Mission

The NASA OSIRIS-REx and JAXA Hayabusa2 missions to near-Earth asteroids Bennu and Ryugu share similar mission goals of understanding the origins of primitive, organic-rich asteroids. Under an agreement between JAXA and NASA, there is an on-going and productive collaboration between science teams of Hayabusa2 and OSIRIS-REx missions. Under this agreement, a portion of each of the returned sample masses will be exchanged between the agencies and the scientific results of their study will be shared. NASA’s portion of the returned Hayabusa2 sample, consisting of 10% of the returned mass, will be jointly separated by NASA and JAXA. The sample will be legally and physically transferred to NASA’s dedicated Hayabusa2 curation facility at Johnson Space Center (JSC) no later than one year after the return of the Hayabusa2 sample to Earth (December 2020). The JSC Hayabusa2 curation cleanroom facility design has now been completed. In the same manner, JAXA will receive 0.5% of the total returned OSIRIS-REx sample (minimum required sample to return 60 g, maximum sample return capacity of 2 kg) from the rest of the specimen. No later than one year after the return of the OSIRIS-REx sample to Earth (September 2023), legal, physical, and permanent custody of this sample subset will be transferred to JAXA, and the sample subset will be brought to JAXA’s Extraterrestrial Sample Curation Center (ESCuC) at Institute of Space and Astronautical Science, Sagamihara City Japan.

Nakamura-Messenger, Keiko↗

The Multi-Mission Earth Entry Vehicle for Sample Return Missions – Past, Present, and Future

The Multi-Mission Earth Entry Vehicle (MMEEV) is an enabling technology developed at NASA’s Langley Research Center (LaRC) over the last two decades for returning samples to Earth across a wide array of space science missions. Currently, the MMEEV is being considered for NASA’s Mars Sample Return (MSR) mission. The original vehicle concept, the Earth Entry Vehicle (EEV), was innovated at LaRC in 1998 as a robust solution to return Mars soil samples to Earth under stringent backward contamination requirements. These backward contamination requirements drove the EEV to have higher reliability than any capsule previously designed for a return-to-Earth sample return mission. The EEV achieved this high reliability by employing a passive (no active systems) vehicle architecture optimized for fault tolerance in a compact, low-mass configuration that is extensible to virtually any sample return mission. The original EEV concept utilized a carbon-carbon primary structure with high-density carbon phenolic thermal protection system. The capsule had a 60-degree sphere-cone forebody and a backshell geometry uniquely tailored to produce aerodynamics that would passively re-orient the vehicle if it entered the atmosphere with an off-nominal attitude. Contrary to every other sample return capsule conceived at the time, the EEV was designed to land without a parachute. The vehicle incorporated an integral energy-absorbing crushable structure that protected the Mars sample for landings on surfaces ranging from soft soil to solid concrete. This paper describes 20 years of technological advancements LaRC has incorporated into the EEV architecture to evolve it from the original, MSR-enabling vehicle, to a true multi-mission capability relevant to any sample return mission. The vehicle’s unique Integrated Composite Stiffener Structure (ICoSS) has been optimized for specific strength - supporting high-G atmospheric entries with steep entry angles that produce precise landing footprints on the ground. The vehicle geometry has been refined through wind tunnel testing and computational fluid dynamics simulations to improve the vehicle’s aerodynamic stability and robustness to off-nominal conditions from hypersonic to subsonic flight. The resulting configuration of the current MMEEV architecture is described, with details provided on its sample carrying capacity and atmospheric entry trajectory capabilities. The upgraded vehicle performance is mapped into current space science objectives, showing how the MMEEV supports future sample return missions and continues to be an enabling technology for NASA’s vision to return samples from Mars.

J M Corliss↗

Curation planning and facilities for asteroid Bennu samples returned by the OSIRIS-REx mission

NASA's OSIRIS-REx spacecraft collected samples from carbonaceous near-Earth asteroid (101955) Bennu on October 20, 2020, and will deliver them to the Earth on September 24, 2023. The samples will be processed at the NASA Johnson Space Center (JSC), where most of the sample collection will be subsequently curated in a new cleanroom suite. The spacecraft collected loose regolith two ways: in a bulk sample chamber capable of holding up to 2 kg, and on industrial Velcro “contact pads” intended to collect small particles at the surface. Included in the JSC collection will be the bulk sample, the contact pads, contamination-monitoring witness plates, and supporting hardware. Planning for the curation of the samples and hardware started at the earliest phase of proposal development and continued in parallel with project development and execution. Because a major mission goal is characterization of organic compounds in the Bennu samples, extra effort was spent in the design stage to ensure a clean curation environment. Here, we describe the preparations to receive the sample, including the design, construction, outfitting, and monitoring of the cleanrooms at JSC; the planned recovery of the sample-containing capsule when it lands on Earth; and the approach to characterizing and cataloging the samples. These curation efforts will result in the distribution of pristine Bennu samples from JSC to the OSIRIS-REx science team, international partners, and the global scientific community for years to come.

curation↗

Connecting Community Scientific Hypotheses to Mars Sample Science

The proposed Mars Sample Return (MSR) program seeks to bring back to Earth a set of specially curated samples from the surface of Mars. The first segment of the MSR program is presently under-way; the Mars 2020 rover Perseverance has, to date, collected 24 samples of martian rock, regolith, and at-mosphere within Jezero crater. Its geologically diverse rock sample set can provide insight into the time evolu-tion of the Jezero environment, including the possible preservation of ancient biosignatures. Presently, a cache of 10 samples has been deposited in the Three Forks region on the floor of Jezero crater. These sam-ples, deemed scientifically return worthy by the Mars science community [1], are intended as a contingency sample set, as Perseverance has subsequently obtained more samples, and is therefore storing a more compre-hensive and scientifically valuable set of samples that will grow as the rover ascends to the rim of Jezero crater. The return of samples from Mars has been identi-fied as the highest priority planetary mission in the past three National Academies Decadal Surveys [2-4]. Sub-stantial work has gone into establishing science objec-tives for an MSR program, an overall framework for sample retrieval and analysis, and the expected impact on future Mars science and exploration (e.g., [5]). These objectives have been established at a relatively high level, e.g., “Interpret the primary geologic pro-cesses and history that formed the martian geologic rec-ord, with an emphasis on the role of water.” (Objective 1 in [5]) and are designed to encapsulate the broad sci-entific priorities of, and lay the groundwork for, inves-tigation strategies and measurements to be conducted by a future MSR program. It is from this overarching framework that the Connecting Community Scientific Hypotheses to Mars Sample Science workshop (‘The Workshop’) was conceived, with the purpose of distil-ling these high-level scientific objectives into discrete, testable hypotheses across a range of scientific disci-plines. The output of the workshop is meant to be a ‘hy-pothesis document’ serving as a starting point for cata-loging and condensing specific hypotheses for consid-eration by the scientific community. The template for this approach is based on the “driving hypotheses” de-veloped by the OSIRIS-REx team as part of their Sam-ple Analysis Plan [6].

Michael A Mischna↗

A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

Koh, Chung-Yan↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Improved Sampling Algorithms in the Risk-Informed Safety Margin Characterization Toolkit

The RISMC approach is developing advanced set of methodologies and algorithms in order to perform Probabilistic Risk Analyses (PRAs). In contrast to classical PRA methods, which are based on Event-Tree and Fault-Tree methods, the RISMC approach largely employs system simulator codes applied to stochastic analysis tools. The basic idea is to randomly perturb (by employing sampling algorithms) timing and sequencing of events and internal parameters of the system codes (i.e., uncertain parameters) in order to estimate stochastic parameters such as core damage probability. This approach applied to complex systems such as nuclear power plants requires to perform a series of computationally expensive simulation runs given a large set of uncertain parameters. These types of analysis are affected by two issues. Firstly, the space of the possible solutions (a.k.a., the issue space or the response surface) can be sampled only very sparsely, and this precludes the ability to fully analyze the impact of uncertainties on the system dynamics. Secondly, large amounts of data are generated and tools to generate knowledge from such data sets are not yet available. This report focuses on the first issue and in particular employs novel methods that optimize the information generated by the sampling process by sampling unexplored and risk-significant regions of the issue space: adaptive (smart) sampling algorithms. They infer system response from surrogate models constructed from existing samples and predict the most relevant location of the next sample. It is therefore possible to understand features of the issue space with a small number of carefully selected samples. In this report, we will present how it is possible to perform adaptive sampling using the RISMC toolkit and highlight the advantages compared to more classical sampling approaches such Monte-Carlo. We will employ RAVEN to perform such statistical analyses using both analytical cases but also another RISMC code: RELAP-7.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Say where you sample: Increasing site selection transparency in urban ecology

Urban ecological studies have the potential to extend our understanding of socio-ecological systems beyond that of an individual city or region. Cross-comparative empirical work and synthesis are imperative to develop a general urban ecological theory. This can be achieved only if studies are replicable and generalizable. Transparency in methods reporting facilitates generalizability and replicability by documenting the decisions scientists make during the various steps of research design; this is particularly true for sampling design and selection because of their impact on both internal and external validity and the potential to unintentionally introduce bias. Three interdependent aspects of sample design are study sample selection (e.g., specific organisms, soils, or water), sample specification (measurement of specific variable of interest), and site selection (locations sampled). Of these, documentation of site selection—the where component of sample design—is underrepresented in the urban ecology literature. Using a stratified random sample of 158 papers from 12 major urban ecology journals, we investigated how researchers selected study sites in urban ecosystems and evaluated whether their site selection methods were transparent. We extracted data from these papers using a 50-question, theory-based questionnaire and a multiple-reviewer approach. Our sample represented almost 45 years of urban ecology research across 40 different countries. We found that more than 80% of the papers read were not transparent in their site selection methodology. We do not believe site selection methods are replicable for 70% of the papers read. Key weaknesses include incomplete descriptions of populations and sampling frames, urban gradients, sample selection methods, and property access. Low transparency in reporting the where methodology limits urban ecologists’ ability to assess the internal and external validity of studies’ findings and to replicate published studies; it also limits the generalizability of existing studies. The challenges of low transparency are particularly relevant in urban ecology, a field where standard protocols for site selection and delineation are still being developed. These limitations interfere with the fields’ ability to build theory and inform policy. We conclude by offering a set of recommendations to increase transparency, replicability, and generalizability.

54 ENVIRONMENTAL SCIENCES↗

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Iterative self-organizing SCEne-LEvel sampling (ISOSCELES) for large-scale building extraction

Convolutional neural networks (CNN) provide state-of-the-art performance in many computer vision tasks, including those related to remote-sensing image analysis. Successfully training a CNN to generalize well to unseen data, however, requires training on samples that represent the full distribution of variation of both the target classes and their surrounding contexts. With remote sensing data, acquiring a sufficiently representative training set is a challenge due to both the inherent multi-modal variability of satellite or aerial imagery and the general high cost of labeling data. To address this challenge, we have developed ISOSCELES, an Iterative Self-Organizing SCEne LEvel Sampling method for hierarchical sampling of large image sets. Using affinity propagation, ISOSCELES automates the selection of highly representative training images. Compared to random sampling or using available reference data, the distribution of the training is principally data driven, reducing the chance of oversampling uninformative areas or undersampling informative ones. In comparison to manual sample selection by an analyst, ISOSCELES exploits descriptive features, spectral and/or textural, and eliminates human bias in sample selection. Using a hierarchical sampling approach, ISOSCELES can obtain a training set that reflects both between-scene variability, such as in viewing angle and time of day, and within-scene variability at the level of individual training samples. We verify the method by demonstrating its superiority to stratified random sampling in the challenging task of adapting a pre-trained model to a new image and spatial domain for country-scale building extraction. Using a pair of hand-labeled training sets comprising 1,987 sample image chips, a total of 496,000,000 individually labeled pixels, we show, across three distinct model architectures, an increase in accuracy, as measured by F1-score, of 2.2–4.2%.

42 ENGINEERING↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Correcting intensity loss errors in the absence of texture-free reference samples during pole figure measurement

Even with the use of X-ray polycapillary lenses, sample tilting during pole figure measurement results in a decrease in the recorded X-ray intensity. The magnitude of this error is affected by the sample size and/or the finite detector size. These errors can be typically corrected by measuring the intensity loss as a function of the tilt angle using a texture-free reference sample (ideally made of the same alloy as the investigated material). Since texture-free reference samples are not readily available for all alloys, the present study employs an empirical procedure to estimate the correction curve for a particular experimental configuration. It involves the use of real texture-free reference samples that pre-exist in any X-ray diffraction laboratory to first establish the empirical correlations between X-ray intensity, sample tilt and their Bragg angles and thereafter generate correction curves for any Bragg angle. It will be shown that the empirically corrected textures are in very good agreement with the experimentally corrected ones. - Highlights: •Sample tilting during X-ray pole figure measurement leads to intensity loss errors. •Texture-free reference samples are typically used to correct the pole figures. •An empirical correction procedure is proposed in the absence of reference samples. •The procedure relies on reference samples that pre-exist in any texture laboratory. •Experimentally and empirically corrected textures are in very good agreement.

36 MATERIALS SCIENCE↗

Current and future federal and state sampling guidance for per- and polyfluoroalkyl substances in environmental matrices

Per- and polyfluoroalkyl substances (PFAS) are a class of emerging contaminants composed of an estimated 5000 to 10,000 human-made, fluorinated, organic chemicals. Due to the complexity of PFAS, the need for multiple environmental matrix considerations and the absence of a promulgated federal standard for environmental sampling and analysis, U.S. states have begun developing health-based regulatory and/or guidance values for a limited number of PFAS in environmental matrices. As there is a growing body of science to inform PFAS sampling guidance standard development, it is important to understand which U.S. states are implementing sampling guidelines and how they plan to handle emerging PFAS. This critical review discusses the current and impending federal and state sampling guidelines for PFAS in environmental matrices, the data gaps surrounding PFAS sampling guidance in U.S. states, and the future impacts of impending guidance documents and regulations. Ten federal guidance documents are available for PFAS sampling guidance and analysis. The maximum number of PFAS covered in these guidance documents is 25 analytes spanning across 8 unique media. While the EPA has developed several different sampling and analytical guidelines for PFAS, there is no formal regulation of PFAS or requirements of states to enforce these guidelines. Consequently, only 31 states have informally adopted sampling guidelines, while the other 19 states have no guidance documentation in place for PFAS. The introduction of new PFAS sampling guidelines by the EPA, as well as updated analytical guidelines that target more PFAS or total organofluoride, is expected to continuously shift the landscape of federal and state guidance for PFAS sampling moving forward.

54 ENVIRONMENTAL SCIENCES↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of sampling techniques on short-term survival and genotyping success of salmonid fry

ABSTRACT Objective Genetics tools have become an integral part of managing and understanding fish populations. Generally, a small tissue sample, such as a fin clip, is taken and then genotyped, with little effect on survival of the fish. However, tissue sampling may have a larger effect on juvenile fish survival compared to their adult counterparts. We evaluated survival and genotyping success of various genetic sampling techniques for Chinook Salmon Oncorhynchus tshawytscha and Rainbow Trout Oncorhynchus mykiss fry. Methods Three sampling treatments were evaluated including control (anesthetized and handled), fin clipping (partial caudal fin clip), and swabbing (OmniSwab was used to collect external mucus). Survival was monitored for 12 d posttreatment, and genotyping success was evaluated. Results Survival was high in all treatment groups (i.e., 0.93–1.00) but, on average, was lower in the swab treatment group. Genotyping was successful in 100% of the fin clip samples and 11–50% of the swab samples. Conclusions Results of this study suggest that sampling caudal-fin tissue does not negatively affect fry short-term survival and the small tissue samples yield highly successful genotyping results. Swabbing did not produce successful genotyping results, and fish sampled with swabs experienced higher mortality than those that received fin clips. Results indicate that fin clips should be used for collection of genetic samples from fry.

McCarrick, Darcy K.↗

Comparison of quantum advantage experiments using random circuit sampling

Random circuit sampling, the task of sampling bit strings from a random unitary operator, has been implemented to demonstrate quantum advantage on the Sycamore quantum processor with 53 qubits and on the Zuchongzhi quantum processor with 56 and 61 qubits. Recently, it was claimed that classical computers using tensor network simulation could catch on to current noisy quantum processors for random circuit sampling. While the linear cross-entropy benchmark fidelity was used to certify all these claims, it may not capture statistical properties of outputs in detail. Here, we compare the bit strings sampled from classical computers using tensor network simulation by Pan et al. [F. Pan, K. Chen, and P. Zhang, Phys. Rev. Lett. 129, 090502 (2022)] and by Kalachev et al. [G. Kalachev, P. Panteleev, P. Zhou, and M.-H. Yung, arXiv:2112.15083] with the bit strings from the Sycamore quantum processor. It is shown that all of Kalachev et al.'s samples passed the NIST random number tests. The heat maps of bit strings show that Pan et al.'s and Kalachev et al.'s samples are quite different from the Sycamore or Zuchongzhi samples. The analysis with the Marchenko-Pastur distribution and the Wasssertein distances demonstrates that Kalachev et al.'s samples are statistically closer to the Sycamore samples than Pan et al.'s while the three datasets have similar values for the linear cross-entropy fidelity. In conclusion, our finding implies that further study is needed to certify or beat the claims of quantum advantage using random circuit sampling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗