Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Mars oxygen production system design

The design and construction phase is summarized of the Mars oxygen demonstration project. The basic hardware required to produce oxygen from simulated Mars atmosphere was assembled and tested. Some design problems still remain with the sample collection and storage system. In addition, design and development of computer compatible data acquisition and control instrumentation is ongoing.

Cotton, Charles E.↗

Adaptive data acquisition multiplexing system and method

A reconfigurable telemetry multiplexer is described which includes a monitor-terminal and a plurality of remote terminals. The remote terminals each include signal conditioning for a plurality of sensors for measuring parameters which are converted by an analog to digital converter. CPU's in the remote terminals store instructions for prompting system configuration and reconfiguration commands. The measurements, instructions, and the terminal's present configuration and status data are transmitted to the monitor-terminal and displayed. In response to menu-driven prompts generated and displayed at the monitor-terminal, data generation request commands, status and health commands, and the like are input at the monitor-terminal and transmitted to the remote terminals. The CPU in each remote terminal receives the various commands, stores them in electrically alterable memory, and reacts in accordance with the commands to reconfigure a plurality of aspects of the system. The CPU in each terminal also generates parameter measurements, status and health signals, and transmits these signals of the respective terminals to the monitor-terminal for low data rate operator viewing and to higher rate external transmission/monitor equipment. Reconfiguration may be in real time during the general period of parameter measurement acquisition, and may include alteration of the gain, automatic gain rescaling, bias, and or sampling rates associated with one or more of the parameter measurements made by the remote terminals.

Sinderson, Richard L.↗

Low cost coherent demodulation for mobile satellite terminals

This paper describes some low cost approaches to coherent BPSK demodulation for mobile satellite receivers. The specific application is an Inmarsat-C Land Mobile Earth Station (LMES), but the techniques are applicable to any PSK demodulator. The techniques discussed include combined sampling and quadrature downconversion with a single A/D and novel DSP algorithms for carrier acquisition offering both superior performance and economy of DSP resources. The DSP algorithms run at 5.7 MIPS, and the entire DSP subsystem, built with commercially available parts, costs under $60 at quantity-10,000.

Dutta, Santanu↗

Using dark current data to estimate AVIRIS noise covariance and improve spectral analyses

Starting in 1994, all AVIRIS data distributions include a new product useful for quantification and modeling of the noise in the reported radiance data. The 'postcal' file contains approximately 100 lines of dark current data collected at the end of each data acquisition run. In essence this is a regular spectral-image cube, with 614 samples, 100 lines and 224 channels, collected with a closed shutter. Since there is no incident radiance signal, the recorded DN measure only the DC signal level and the noise in the system. Similar dark current measurements, made at the end of each line are used, with a 100 line moving average, to remove the DC signal offset. Therefore, the pixel-by-pixel fluctuations about the mean of this dark current image provide an excellent model for the additive noise that is present in AVIRIS reported radiance data. The 61,400 dark current spectra can be used to calculate the noise levels in each channel and the noise covariance matrix. Both of these noise parameters should be used to improve spectral processing techniques. Some processing techniques, such as spectral curve fitting, will benefit from a robust estimate of the channel-dependent noise levels. Other techniques, such as automated unmixing and classification, will be improved by the stable and scene-independence noise covariance estimate. Future imaging spectrometry systems should have a similar ability to record dark current data, permitting this noise characterization and modeling.

Boardman, Joseph W.↗

CO2 Acquisition Membrane (CAM) Project

The CO2 Acquisition Membrane (CAM) project will develop, test, and analyze membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The CAM technology will enable passive separation of these gases, allow energy efficient acquisition and purification of these important resources, and lay the foundation for future unmanned sample return and human space missions. The CAM membranes are targeted toward In Situ Resource Utilization (ISRU) applications, such as In Situ Propellant Production (ISPP) and In Situ Consumables Production (ISCP).

Mason, L. W.↗

Moon Mineral Mapper (M3): A High Uniformity and High Precision Science Imaging Spectrometer in the Solar Reflected Spectrum

The Moon Mineralogy Mapper was selected as a NASA Discovery Mission of Opportunity in February 2005. At the core of this mission is an imaging spectrometer instrument with high spectral-spatial uniformity and high signal-to-noise ratio for the expected illumination conditions. The spectral range of the Moon Mineralogy Mapper is from 430 to 3000 nm with 10 nm spectral sampling. The radiometric range is from 0 to maximum expected radiance with 14 bit sampling. The spatial swath is nominally 40 Ian with 70 m spatial sampling. The Moon Mineralogy Mapper has both a global and target mode of data acquisition. In global spectral and spatial resolution full coverage of the Moon will be acquired. Target mode will be used to examine selected areas a full spectral and spatial resolution. The science objectives and mission and instrument characteristics are presented.

mapping↗

Innovative Video Diagnostic Equipment for Material Science

Materials science experiments under microgravity increasingly rely on advanced optical systems to determine the physical properties of the samples under investigation. This includes video systems with high spatial and temporal resolution. The acquisition, handling, storage and transmission to ground of the resulting video data are very challenging. Since the available downlink data rate is limited, the capability to compress the video data significantly without compromising the data quality is essential. We report on the development of a Digital Video System (DVS) for EML (Electro Magnetic Levitator) which provides real-time video acquisition, high compression using advanced Wavelet algorithms, storage and transmission of a continuous flow of video with different characteristics in terms of image dimensions and frame rates. The DVS is able to operate with the latest generation of high-performance cameras acquiring high resolution video images up to 4Mpixels@60 fps or high frame rate video images up to about 1000 fps@512x512pixels.

Capuano, G.↗

Multi-Beam Laser Beacon Propagation Over Lunar Distance: Comparison of Predictions and Measurements

A multi-beam beacon was transmitted from the Optical Communication Telescope Laboratory (OCTL) located at Table Mountain, CA to the Lunar Laser Space Terminal (LLST), on-board the Lunar Atmospheric Dust and Environment Explorer (LADEE) spacecraft, during NASA’s recent Lunar Laser Communication Demonstration (LLCD). The laser beacon (1568?0.1 nm) was square wave modulated and sensed by a LLST quadrant sensor to enable link acquisition and tracking. LLST computed the mean received beacon power and returned 5 kHz sampled power time series over the downlink. Post-processing of the decoded downlink received at OCTL retrieved the uplink power recorded at LLST. The predicted mean irradiance delivered to LLST consistently agreed with the variable beam divergence transmitted from OCTL to within < 1 decibel (dB). Irradiance fluctuations detected at LLST were reconciled with an uplink wave-propagation model derived using independently monitored atmospheric parameters. We report good agreement of the scintillation index and atmospheric coherence time.

Biswas, A↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

A fast lightstripe rangefinding system with smart VLSI sensor

The focus of the research is to build a compact, high performance lightstripe rangefinder using a Very Large Scale Integration (VLSI) smart photosensor array. Rangefinding, the measurement of the three-dimensional profile of an object or scene, is a critical component for many robotic applications, and therefore many techniques were developed. Of these, lightstripe rangefinding is one of the most widely used and reliable techniques available. Though practical, the speed of sampling range data by the conventional light stripe technique is severely limited. A conventional light stripe rangefinder operates in a step-and-repeat manner. A stripe source is projected on an object, a video image is acquired, range data is extracted from the image, the stripe is stepped, and the process repeats. Range acquisition is limited by the time needed to grab the video images, increasing linearly with the desired horizontal resolution. During the acquisition of a range image, the objects in the scene being scanned must be stationary. Thus, the long scene sampling time of step-and-repeat rangefinders limits their application. The fast range sensor proposed is based on the modification of this basic lightstripe ranging technique in a manner described by Sato and Kida. This technique does not require a sampling of images at various stripe positions to build a range map. Rather, an entire range image is acquired in parallel while the stripe source is swept continuously across the scene. Total time to acquire the range image data is independent of the range map resolution. The target rangefinding system will acquire 1,000 100 x 100 point range images per second with 0.5 percent range accuracy. It will be compact and rugged enough to be mounted on the end effector of a robot arm to aid in object manipulation and assembly tasks.

Gruss, Andrew↗

Development of Low-Cost Micromanipulation Systems for Small Extraterrestrial Samples

The analysis of microscale to mm-scale astromaterials often involves the transfer of samples from storage or collection substrates to analytical substrates. These transfers are accomplished by hand (via tweezers or fine-tipped needles) or by utilizing micromanipulation instruments. Freehand manipulation of small particles is extremely challenging due to involuntary hand tremors on the order of 100μm and due to the triboelectric charging induced by frequent contact between the manipulation tool and the support substrate. Months or years of practice may be required before an investigator develops the necessary experience to confidently transfer a 10-20μm particle in this manner. Handling even mm-sized particles with fine-tipped tweezers can be challenging, due to the inability to precisely control the force with which grains are being held. Mechanical, hydraulic, and motorized/electrical micromanipulators enable the precise handling of microscale samples and are often utilized in laboratories where frequent small sample preparation is required. However, the price of such instruments (~ $10,000 to $100,000) makes them cost-prohibitive for some institutions. Graduate students or early-career scientists interested in conducting research on interplanetary dust particles, Itokawa particles returned by Hayabusa, or future samples returned by OSIRIS-REx or Hayabusa2 may experience difficulty in justifying the expense of a micromanipulator to their advisors or principle investigators. Johnson Space Center’s Astromaterials Acquisition and Curation Office and the Lunar and Planetary Institute conduct annual training for early career scientists and for investigators that require experience with handling of small extraterrestrial samples. In support of this training, we have been developing low-cost mechanical alternatives to expensive micromanipulators that training participants can implement in their respective facilities.

Snead, Christopher J.↗

Hyperspectral acquisition with ScanImage at the single pixel level: application to time domain coherent Raman imaging

We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time-dependent signal varies at each pixel level. In the proposed acquisition scheme, the scan along the X-axis is slowed down while the data acquisition is maintained at a high pace to enable the rapid acquisition of the time-dependent signal at each pixel level. The ScanImage generated raw 2D images have a very asymmetric aspect ratio between X and Y, the X axis encoding both for space and time acquisition. The results are X-axis macro-pixel where the associated time-dependent signal is sampled to provide hyperspectral information. We exemplified the proposed hyperspectral scheme in the context of time-domain coherent Raman imaging, where a pump pulse impulsively excites molecular vibrations that are subsequently probed by a time-delayed probe pulse. In this case, the time-dependent signal is a fast acousto-optics delay line that can scan a delay of 4.5ps in 25 μ s at each pixel level. With this acquisition scheme, we demonstrate ultra-fast hyperspectral vibrational imaging in the low frequency range [10 cm −1 , 150 cm −1 ] over a 500 μm field of view (64 x 64 pixels) in 130ms (∼ 7.5 frames/s). The proposed acquisition scheme can be readily extended to other applications requiring the acquisition of a fast-evolving signal at each pixel level.

Metais, Samuel↗

Missing observations in multiyear rotation sampling designs

Because Multiyear estimation of at-harvest stratum crop proportions is more efficient than single year estimation, the behavior of multiyear estimators in the presence of missing acquisitions was studied. Only the (worst) case when a segment proportion cannot be estimated for the entire year is considered. The effect of these missing segments on the variance of the at-harvest stratum crop proportion estimator is considered when missing segments are not replaced, and when missing segments are replaced by segments not sampled in previous years. The principle recommendations are to replace missing segments according to some specified strategy, and to use a sequential procedure for selecting a sampling design; i.e., choose an optimal two year design and then, based on the observed two year design after segment losses have been taken into account, choose the best possible three year design having the observed two year parent design.

Gbur, E. E.↗

Efficient boundary-guided scanning for high-resolution X-ray ptychography

In the realm of X-ray ptychography experiments, a considerable amount of ptychography scans are typically performed within a field of view encompassing the target sample. While it is crucial to obtain overlapping scans in small increments over the region of interest for achieving high-resolution sample reconstruction, a significant number of these scans often redundantly measure the empty background within the wide field of view. To address this inefficiency, an innovative algorithm is proposed that introduces automatic guidance for data acquisition. The algorithm first directs the scan point to actively search for the object of interest within the field of view. Subsequently, it intelligently scans along the perimeter of the sample, strategically acquiring measurements exclusively within the boundary of the region of interest. By employing this approach, a reduction in the number of measurements required to obtain high-resolution reconstruction images is demonstrated, as compared with conventional raster scanning methods. Furthermore, the automatic guidance provided by the algorithm offers the added advantage of saving valuable time during the reconstruction process. Through practical implementation on real experiments, these findings showcase the efficacy of the proposed algorithm in enhancing the efficiency and accuracy of X-ray ptychography experiments. This novel approach holds immense potential for advancing sample analysis and imaging techniques in various scientific disciplines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Description of the SSF PMAD dc testbed control system data acquisition function

A functional description of the various levels of the SSF power management and distribution dc test-bed control system architecture is presented, and the data acquisition function and the status of its implementation are described. The data requirements for the test-bed control system are dictated by the functionality being implemented at each level of the architecture. The test-bed control system hierarchy data acquisition function is distributed among its various levels. Fast-acting control functions that require time critical data are implemented at the lowest level. These functions require periodic data sampling to assure safe system operation and performance. Slower response control functions are implemented at the higher levels and require data to be reported at least every second. The present data acquisition function meets the requirements for a hierarchical and distributed power management and control system.

Baez, Anastacio N.↗

Characterization of biological materials with soft X-ray scattering

The complex structure of biological assemblies is crucial for function yet challenging to discern given the chemical similarities between constituent components. Hard X-ray techniques, for example, rely on small density differences between domains that lead to modest scattering intensities. Resonant soft X-ray scattering (RSoXS) uses X-rays below 2 keV to access absorption edges of low-Z elements. In this way, RSoXS can enhance scattering contrast between domains of different chemical compositions or bonding motifs, thus providing structural information about specific chemical motifs. RSoXS is emerging as a technique applicable for biological systems, having been used to characterize protein structure in solution and polysaccharide organization in plant cell walls. Sample environment instrumentation, however, is challenging in the current state of the art, particularly with liquid samples. Here, this chapter contains a brief introduction to RSoXS and current beamline capabilities, and provides methods to prepare, store, and mount biological samples for RSoXS characterization. Furthermore, key details during RSoXS and X-ray absorption data acquisition are highlighted and some future opportunities in RSoXS instrumentation for biological systems are discussed.

47 OTHER INSTRUMENTATION↗