Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resource consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

2015-2017 California Vehicle Survey

The 2015-2017 California Vehicle Survey of residential and commercial light-duty vehicle owners in California assessed consumer preferences for vehicles and included a targeted sample of plug-in electric vehicle (PEV) owners. Resource Systems Group conducted the survey on behalf of the California Energy Commission. In addition to economic and demographic data, the survey integrated light-duty vehicle holding and use information with vehicle choice data collected via the stated preferences survey's set of eight vehicle and fuel type choice exercises. The PEV owner survey participants provided additional data on charging behavior, electricity rates, and their main motivations for purchasing PEVs.

1Hz data↗

Assessing the Current State of U.S. Energy Equity Regulation and Legislation [Slides]

This report examined state energy equity actions from January 2020 to July 2022. Lawrence Berkeley National Laboratory and Pacific Northwest National Laboratory partnered with E9 Insight to screen executive, legislative, and regulatory actions focusing on energy equity. A total of 95 actions were identified across 22 states and Washington, DC. Energy equity was most associated with resource planning, decarbonization, and energy efficiency regulatory focus areas. States tended to focus on distributive and procedural justice tenets over recognition and restorative justice tenets. The review also suggested that energy equity metrics are in nascent stages; most outcomes identified in equity actions did not have corresponding metrics. Affordability and energy burden were identified as metrics in multiple cases and appeared in several different forms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlling solvation in conducting redox polymers for selective electrochemical separation of nitrate from wastewater

Selective capture of nitrate from wastewater is crucial for ensuring safe drinking water and promoting resource circularity. This study investigated alkylated polyaniline redox polymers as highly-selective electrosorbents to address this challenge. By controlling polymer solvation properties through synthetic functionalization, poly(N-methylaniline) (PNMA) achieves a nitrate uptake of up to 1.38 mmol g −1 -polymer and a separation factor of 7 over chloride. Poly(N-butylaniline) (PNBA) further enhances selectivity, achieving a separation factor beyond 14 due to increased hydrophobicity. The mechanisms underlying this selectivity are investigated using ab initio molecular dynamics (AIMD) and in-situ electrochemical quartz crystal microbalance (EQCM) studies, which reveal that hydrophobicity reduces chloride binding. A technoeconomic analysis indicates that methylation on PANI reduces nitrate removal costs by 50% compared to non-functionalized PANI, due to enhanced selectivity and uptake, and decreased energy consumption. PNMA electrodes demonstrate practical nitrate selectivity over 20 versus chloride in real wastewater, while avoiding sulfate binding. This study highlights the potential of controlling solvation at electroactive polymers to enhance nitrate selectivity, offering a promising design path for redox-mediated electrochemical separations.

chemical engineering↗

Infrastructure and resource development needs to support a significant expansion of US nuclear capacity

In December 2023, the United States pledged at a United Nations conference to triple nuclear energy by 2050. In May of 2025 a new administration announced plans to quadruple nuclear energy by 2025, setting a new target that requires understanding the key infrastructure and resources needed to achieve large-scale deployment. This study attempts to quantify “what it takes” to deploy an additional 200 GWe of nuclear capacity. It projects demand levels for workforce, fuel, uranium mining and enrichment, waste management, supply chain, land, licensing, and water. Demand growth is also contextualized. For example, the peak number of construction workers required is approximately 215,000, a 37 % increase in the current US utility construction workforce. Up to 80,000 MT/year of mined uranium will be needed, necessitating a 60-fold increase in US mining production or a doubling of global mining if sourced externally. Advanced reactor fuels, uranium mining, and nuclear-grade equipment production would need substantial expansion. Operational workforce, enrichment needs, and licensing submissions also face significant increases. Although water consumption may see relatively lower increases, securing water rights poses unique challenges. This study consolidates various demand metrics in a broad context, highlighting the necessity of early preparations, such as workforce training, to support a tripling of nuclear energy. While it outlines the demand-side requirements, it does not assess the difficulties of ramping up or other supply-side issues. The findings also shed light on the impact of reactor size and reactor technology on various demand metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen Energy Storage Integrated with a Combined Cycle Plant

A project is being developed that will build upon the existing infrastructure and resources at the Intermountain Power Project (IPP) site to provide reliable, dispatchable energy and to support the transmission of renewable energy resources while transitioning to an economical green energy future. The concept study depicted in this report outlines a techno-economic optimization to fulfill the demand for 30% vol hydrogen co-firing in the IPP 840 MW advanced class combined cycle power plant. In an initial step, a site assessment concluded the site has sufficient land available to co-locate a hydrogen production and storage facility. The team evaluated and defined a scalable concept that considered technology characteristics, including input and output models to be used for optimization purposes. The concept for the hydrogen production and storage system integrates multiple technologies, to determine system size and scalable approach, for each of the technologies evaluated, the team defined component and subcomponent sizes, minimum and maximum capacity, modularity, component utility consumption (electric, water), component flexibility and servicing, layout, and technology status, as well as technology alternatives. For hydrogen generation, the project considers Siemens Energy’s Silyzer-300 (S300) technology, a 17.5 MW modular Proton Exchange Membrane (PEM) electrolyzer. For the S300 configuration, the team determined that three S300 arrays, or approximately 1,000 kg/hr, per block would yield a compact block design. This configuration results in a fairly wide and flexible arrangement that fits well into the spaces available at the site. Therefore, the overall design approach is based on multiple identical blocks of 3 arrays to minimize engineering cost and optimize constructability. In parallel, a transmission screening study was conducted to determine any potential transmission constraints from the energy sources that could feed the hydrogen production equipment. The study results show that minimum transmission constraints would be encountered to deliver 400 MW renewable generation from southern California, or south-central Wyoming. At last, the techno-economic analysis concluded that a scenario that uses solar and wind power yields the lowest levelized cost of hydrogen (LCOH 2 ) production and the lowest cost per tonne of CO 2 reduced. In this optimized scenario, the hydrogen production plant was determined as 6,201 kg/hr and the hydrogen storage (underground cavern) was determined as 4,600 tonnes. The resulting capacity factor for the hydrogen production plant was 66.33% with 8,745 operating hours in one year. This techno-economic analysis provided various options for integrating hydrogen storage at the Intermountain Power Plant site to co-fire the CCPP units. The results provide insightful data about the magnitude of capacity needed and the economics of producing hydrogen and reducing CO 2 emissions.

08 HYDROGEN↗

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Herbaceous Feedstock 2019 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the State of Technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and elsewhere (such as the High-Tonnage Feedstock Logistics projects (Webb et al. 2013a, Webb et al. 2013b, Webb et al. 2013c, Webb and Sokhansanj 2014, Sokhansanj et al. 2014)) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D improvements to individual supply system unit operations and present the status of feedstock logistics technology development for converting biomass into biofuels. These analyses are supported by experimental data where possible and help to align the SOT relative to the cost goals defined in the Multi-Year Program Plan. The 2019 Herbaceous SOT incorporates several technology changes in feedstock preprocessing and introduces opportunities from the integrated landscape management (ILM) strategy and increased grower participation to reduce biomass access costs, while maintaining or improving grower profitability. During FY18 uneven flow from the horizontal bale grinder was identified as a significant issue limiting preprocessing system throughput. Based on FSL-funded research at INL, the 2019 Herbaceous SOT replaces the horizontal bale grinder used in the first stage size reduction with a bale processor. The improved uniformity of biomass flow entering the PDU eliminated slugging flow from the first stage size reduction and improved the throughput of downstream operations. In order to achieve moisture reduction through frictional heating during grinding (which allowed elimination of the costly rotary drum dryer in previous SOTs), the second stage grinder was changed from a rotary shear, which does not remove moisture, back to a hammer mill. Finally, the 2019 Herbaceous SOT introduces modified three-pass and two-pass corn stover supply curves derived from the BT16 resource assessment, based on FY19 modeling results (WBS 4.2.1.20) quantifying economic benefits of ILM in the supply area, together with modeling results (WBS 1.2.1.5) identifying ILM strategies to increase grower participation. The 2019 Herbaceous SOT report documents the current modeled cost of an herbaceous feedstock supply system from harvest to the pretreatment reactor throat for hydrocarbon fuel production via biochemical conversion, based on equipment and processes now available or potentially available in the near term. The modeled cost also considers both the required quality and the availability of the biomass resources. The 2019 Herbaceous SOT predicts a modeled delivered feedstock cost of $81.37 /dry ton (2016$); this is a $2.30/dry ton (2016$) decrease from the 2018 Herbaceous SOT. Technology improvements that contributed to this modeled cost reduction include reduced cost for the new preprocessing design and quantification of the opportunities of the integrated landscape management (ILM) strategy and an increased grower participation rate to reduce the grower payment portion of biomass access costs, while maintaining or improving grower profitability. A greenhouse gas emissions (GHG) assessment was completed by Argonne National Laboratory using the 2019 Greenhouse Gases, Regulated Emissions, and Energy use in Transportation model, estimating an increase of 14.89 kg CO2e/ton from the 2018 SOT (69.27 kg CO2e/ton in 2018 to 84.16 kg CO2e/ton in 2019). The increase of energy consumption during preprocessing along with higher transportation distance to access low cost biomass from further distance contributed to the increase of GHG emissions in the 2019 Herbaceous SOT. The reason for the increased transportation distances was the cost tradeoff of going farther from the biorefinery to access the cheaper ILM-derived counties (the cheaper price outweighed the cost of increased supply radius).

09 BIOMASS FUELS↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying Non-Energy Impacts from Other Jurisdictions in Cost-Benefit Analyses of Energy Efficiency Programs: Resources for States for Utility Customer-Funded Programs

Avoided energy and capacity costs are the primary yardstick utilities use to determine which energy efficiency programs are cost-effective for their customers. But sometimes "non-energy impacts" — not commonly recognized as directly associated with energy generation, transmission and distribution — represent substantial benefits, such as improving comfort, air quality and public health. Considering whether and how to include non-energy impacts is an important part of cost-benefit analyses for these programs. This report offers practical considerations for deciding which non-energy impacts to include and how to apply values or methods from other jurisdictions. Researchers reviewed studies quantifying non-energy impacts used in 30 states and applied a five-point system to indicate transferability of a value or method from each study for 16 categories of non-energy impacts: Water resource costs and benefits; Other fuels costs and benefits; Avoided environmental compliance costs; Environmental impacts; Productivity; Health and safety; Asset value; Energy and/or capacity price suppression effects; Avoided costs of compliance with Renewable Portfolio Standard requirements; Avoided credit and collection costs; Avoided ancillary services; Comfort; Economic development and job impacts; Public health impacts; Energy security impacts; Increased reliability. The U.S. Department of Energy’s Building Technologies Office supported this work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying grid reliability and resilience impacts of energy efficiency: Examples and opportunities

Traditional reliability and emerging resilience metrics may not fully recognize benefits from distributed energy resources (DERs) such as energy efficiency. This technical brief explains how existing planning processes for bulk power and distribution systems capture the impact of energy efficiency on power system reliability and resilience with illustrative examples. We identify limitations in using existing reliability and resilience metrics to quantify efficiency and other DER benefits. The brief concludes with a discussion of opportunities to enhance current planning practices to better capture the reliability and resilience value of energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada For Calendar Year 2022

This report includes visual inspection results, descriptions of maintenance and repair activities, and recommendations for calendar year (CY) 2022 for use restrictions (URs) at corrective action sites (CASs) located on the Nevada National Security Site (NNSS) and on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. This document is formatted by project activity (i.e., Industrial Sites, Soils, and Defense Threat Reduction Agency [DTRA]); then by corrective action unit (CAU); and then by CAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An integrated supply chain analysis for cobalt and rare earth elements under global electrification and constrained resources

As global electrification becomes more prominent, demand is projected to increase for electric vehicles (EVs), their components (EV batteries, rare earth traction motors), and their raw materials (cobalt, rare earths). To analyze the supply chain constraints associated with these components and raw materials, a system dynamics model was developed to simulate the interactions between the rare earth and cobalt supply chains. The results showed that under current understanding of raw material resources, production of the projected volume of EVs could be inadequate. To meet the aggressive EV volume sale projections set by the International Energy Agency, EV manufacturers will need to implement a large portion of traction motors without rare earths and utilize non-cobalt batteries as much as possible. On the supply side, a much faster ramp-up than what being modeled would be needed to meet much higher demand than current market forecasts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗