Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference cell performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗

Dissection of the Voltage Losses of an Acidic Quinone Redox Flow Battery

We measure the polarization characteristics of a quinone-bromide redox flow battery with interdigitated flow fields, using electrochemical impedance spectroscopy and voltammetry of a full cell and of a half cell against a reference electrode. We find linear polarization behavior at 50% state of charge all the way to the short-circuit current density of 2.5 A/cm 2 . We uniquely identify the polarization area-specific resistance (ASR) of each electrode, the membrane ASR to ionic current, and the electronic contact ASR. We use voltage probes to deduce the electronic current density through each sheet of carbon paper in the quinone-bearing electrode. By also interpreting the results using the Newman 1-D porous electrode model, we deduce the volumetric exchange current density of the porous electrode. We uniquely evaluate the power dissipation and identify a correspondence to the contributions to the electrode ASR from the faradaic, electronic, and ionic transport processes. We find that, within the electrode, more power is dissipated in the faradaic process than in the electronic and ionic conduction processes combined, despite the observed linear polarization behavior. We examine the sensitivity of the ASR to the values of the model parameters. The greatest performance improvement is anticipated from increasing the volumetric exchange current density.

25 ENERGY STORAGE↗

Uncertainties in Masses, Dimensions, Impurities, and Isotopics of HEU Metal Used in Critical Experiments at ORCEF

This report documents uncertainties in the mass, dimensions, impurities, and isotopics of the highly enriched uranium (HEU) metal (oralloy) used in a wide variety of delayed critical experiments at the Oak Ridge Critical Experiments Facility (ORCEF) in the late 1950s, 1960s, and 1970s. Most of these experiments were performed in the east cell of ORCEF. The accuracies of the masses were much less than 1 gram, the dimensions to 0.0004 in., and 0.0177 wt % uncertainty for the 235U isotopic content of HEU. The total 235U uncertainty for a 25,000 gram mass of oralloy (nominal 93.15 wt% 235U) is 0.054%, which corresponds to ~13 grams. This calculated uncertainty includes the uncertainties associated with impurity content, grams of uranium per grams of oralloy, and isotopic content. These data are of interest to the Working Party of Nuclear Criticality Safety (WPNCS) International Criticality Safety Benchmark Experiment Project (ICSBEP) because these HEU metal critical experiments at ORCEF have been or are being documented as benchmarks for nuclear criticality safety calculations for ICSBEP. This report is a collection of information from various sources, some of which are contained in previous reports and emails. These experiments may be the most accurately described critical experiments ever performed, mainly because of the combination of the Y-12 capabilities for accurately fabricating and defining the materials (mainly HEU metal, referred to as oralloy, an acronym for Oak Ridge alloy) and the care of the researchers in documenting the experiments.

Mihalczo, John T.↗

Requirements and Conceptual Design of Off-gas Systems for the Reprocessing of Metallic Fuels

An assessment has been conducted to determine how key regulations regarding volatile radionuclide emissions to the atmosphere may apply to the off-gas streams associated with electrochemical reprocessing. The scope of this assessment was based upon a generic electrochemical reprocessing scheme with a throughput rate of 200 MTIHM/y applied to metallic fuel discharged from a sodium fast reactor (SFR), but the findings are able to be translated to other advanced nuclear scenarios as merited. Air dispersion modeling was performed using the EPA CAP-88 model and evaluated the uncontrolled decontamination factors (DFs) that would be required to achieve regulatory compliance with the dose-based limits set forth by EPA regulation 40 CFR 190.10(a). These DFs were compared to those required by fuel cycle–based limits set forth by EPA regulation 40 CFR 190.10(b). Two theoretical sites with disparate climatological conditions were selected for air dispersion modeling (Idaho and Tennessee). The radionuclides modeled included 3 H, 85 Kr, 129 I, and selected alpha-emitting transuranic isotopes (referred to here as 239 Pu-TRU <1y ). It was found that the fuel cycle-based limits in 40 CFR 190.10(b) are most restrictive for 85 Kr and 239 Pu-TRU <1y , with DFs of 3 and 6.1E+09, respectively. The dose-based limit as derived from 40 CFR 190.10(a) could require mitigation of tritium in some scenarios, with an estimated DF of about 3 for the reference scenarios. The fuel cycle-based limit for 129 I resulted in a DF of about 240 for the reference scenario. The need for iodine mitigation based on dose to the public depended upon the physical form of iodine as either particulate or vapor-phase species. Emission of iodine from the facility as a vapor necessitated DFs of about 2 but emission as a particulate would require DFs >6,000 to meet thyroid dose-based limits. Effects of physical form on needed iodine mitigation are significant, but the understanding of speciation of iodine both during electrochemical reprocessing and after release to the atmosphere is limited. The electrochemical processing unit operations were evaluated to identify potential release points for the volatile radionuclides and to assess the potential for retention of the radionuclides within the process (thus decreasing the need for mitigation). Mitigation strategies for 3 H, 85 Kr, 129 I, and 239 Pu-TRU <1y were identified. In all cases, there are reasonably achievable pathways to regulatory compliance, although in some cases additional R&D is merited to verify the chemical speciation of these isotopes and to develop and demonstrate potential treatment technologies for this application. Whether or not additional off-gas controls (beyond common operations such as HEPA filtration and oxygen and moisture control) are needed for any of these regulated or volatile radionuclides depends on the (a) type of facility (NRC-regulated or DOE), (b) used fuel process rate, (c) used fuel burnup and composition, (d) speciation and retention of volatile radionuclides in the process and in the cell gas cleanup system, (e) site-specific parameters such as location, meteorology, stack height, and site boundaries, and (f) levels of conservatism and safety factors used in assessing compliance to air emissions regulations. Performance of this assessment revealed several areas where information is lacking or additional research is required in order to better determine if or what kinds of off-gas control might be needed. First, and most significantly, the understanding of the chemical speciation and physical form and partitioning of iodine during electrochemical processing operations is lacking and prevents the ability to accurately assess the potential iodine mitigation requirements. Future research in this area should be multifaceted and include thermodynamic modeling of iodine speciation in different process steps, experiments to quantify the kinetics of vapor-phase and melt-phase transitions, bench-scale experiments to determine the potential chemical and physical form of iodine emissions from the electrorefining process, and verification of iodine behavior with experiments utilizing operational facilities. Similarly, an improved understanding of iodine behavior in the environment after release from the facility stack will be required to refine dose estimations, as particulate and vapor-phase emissions result in significantly different doses to the MEI.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE Analyses of Scenarios in the Molten Salt Reactor Fuel Cycle

In support of the US Nuclear Regulatory Commission non-light-water reactor fuel cycle demonstration project, the capabilities of SCALE 6.3.1 for radionuclide characterization, criticality, and shielding were demonstrated through several scenarios in a molten salt reactor (MSR) nuclear fuel cycle. Three scenarios were selected for this study, with the molten salt breeder reactor (MSBR) serving as the reference design. The original thorium-based fuel salt used in MSBR was replaced with a 235 U-enriched fuel salt to better reflect anticipated future MSR concepts. The first scenario focused on the fuel salt preparation stage. Criticality analyses, using SCALE/CSAS-Shift and SCALE/SAMPLER, examined potential critical configurations in the fresh fuel salt container based on variables such as 235 U enrichment, UF 4 molar fraction, temperature, and container geometry. The second scenario explored the release of fission products during reactor operation in which the tritium buildup in the primary fuel salt was quantified through depletion calculations using SCALE/TRITON with continuous fuel makeup and fractional fission product removal. This scenario also assessed radioactivity levels in the off-gas system (OGS), quantifying radiotoxic nuclides that could be released into the environment. SCALE/SAMPLER was employed to perform uncertainty quantification to identify key operating parameters influencing the buildup of radiotoxic nuclides in the OGS. Additionally, radiation dose rates were calculated using SCALE/MAVRIC to estimate the maximum exposure levels within the reactor cell complex during operation. The final scenario evaluated the decay heat and radioactivity of the primary fuel salt collected in the drain tank, as well as the radiation dose rate outside the building from the presence of the drain tank. Overall, the application of SCALE’s various capabilities for radionuclide inventory generation, criticality analysis, and shielding in MSR fuel cycles was successfully demonstrated across these scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Strain-dependent Damage in Mouse Lung After Carbon Ion Irradiation

Purpose: To examine whether inherent factors produce differences in lung morbidity in response to carbon ion (C-ion) irradiation, and to identify the molecules that have a key role in strain-dependent adverse effects in the lung. Methods and Materials: Three strains of female mice (C3H/He Slc, C57BL/6J Jms Slc, and A/J Jms Slc) were locally irradiated in the thorax with either C-ion beams (290 MeV/n, in 6 cm spread-out Bragg peak) or with {sup 137}Cs {gamma}-rays as a reference beam. We performed survival assays and histologic examination of the lung with hematoxylin-eosin and Masson's trichrome staining. In addition, we performed immunohistochemical staining for hyaluronic acid (HA), CD44, and Mac3 and assayed for gene expression. Results: The survival data in mice showed a between-strain variance after C-ion irradiation with 10 Gy. The median survival time of C3H/He was significantly shortened after C-ion irradiation at the higher dose of 12.5 Gy. Histologic examination revealed early-phase hemorrhagic pneumonitis in C3H/He and late-phase focal fibrotic lesions in C57BL/6J after C-ion irradiation with 10 Gy. Pleural effusion was apparent in C57BL/6J and A/J mice, 168 days after C-ion irradiation with 10 Gy. Microarray analysis of irradiated lung tissue in the three mouse strains identified differential expression changes in growth differentiation factor 15 (Gdf15), which regulates macrophage function, and hyaluronan synthase 1 (Has1), which plays a role in HA metabolism. Immunohistochemistry showed that the number of CD44-positive cells, a surrogate marker for HA accumulation, and Mac3-positive cells, a marker for macrophage infiltration in irradiated lung, varied significantly among the three mouse strains during the early phase. Conclusions: This study demonstrated a strain-dependent differential response in mice to C-ion thoracic irradiation. Our findings identified candidate molecules that could be implicated in the between-strain variance to early hemorrhagic pneumonitis after C-ion irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineering the electronic and strained interface for high activity of PdM core @Pt monolayer electrocatalysts for oxygen reduction reaction

Alloyed nanoparticles with core-shell structures provide a favorable model to modulate interfacial interaction and surface structures at the atomic level, which is important for designing electrocatalysts with high activity and durability. Herein, core-shell structured Pd 3 M@Pt/C nanoparticles with binary PdM alloy cores (M = Fe, Ni, and Co) and a monolayer Pt shell were successfully synthesized with diverse interfaces. Among these, Pd 3 Fe@Pt/C exhibited the best oxygen reduction reaction catalytic performance, roughly 5.4 times more than that of the commercial Pt/C catalyst used as reference. The significantly enhanced activity is attributed to the combined effects of strain engineering, interfacial electron transfer, and improved Pt utilization. Density functional theory simulations and extended X-ray absorption fine structure analysis revealed that engineering the alloy core with moderate lattice mismatch and alloy composition (Pd 3 Fe) optimizes the surface oxygen adsorption energy, thereby rendering excellent electrocatalytic activity. Finally, future researches may use this study as a guide on the construction of highly effective core-shell electrocatalysts for various energy conversions and other applications.

25 ENERGY STORAGE↗

Interfacial Reaction Studies Using ONIOM

In this report, we focus on the calculations of the energetics and chemical kinetics of heterogeneous reactions for Organometallic vapor phase epitaxy (OMVPE). The work described in this report builds upon our own previous thermochemical and chemical kinetics studies. The first of these articles refers to the prediction of thermochemical properties, and the latter one deals with the prediction of rate constants for gaseous homolytic dissociation reactions. The calculations of this investigation are at the microscopic level. The systems chosen consisted of a gallium nitride (GaN) substrate, and molecular nitrogen (N2) and ammonia (NH3) as adsorbants. The energetics for the adsorption and the adsorbant dissociation processes were estimated, and reaction rate constants for the dissociation reactions of free and adsorbed molecules were predicted. The energetics for substrate decomposition was also computed. The ONIOM method, implemented in the Gaussian98 program, was used to perform the calculations. This approach has been selected since it allows dividing the system into two layers that can be treated at different levels of accuracy. The atoms of the substrate were modeled using molecular mechanics6 with universal force fields, whereas the adsorbed molecules were approximated using quantum mechanics, based on density functional theory methods with B3LYP functionals and 6-311G(d,p) basis sets. Calculations for the substrate were performed in slabs of several unit cells in each direction. The N2 and NH3 adsorbates were attached to a central location at the Ga-lined surface.

Cardelino, Beatriz H.↗

Validation of ATR Fission Power Deposition Fraction in HEU and LEU Fuel Plates

The Advanced Test Reactor (ATR) is a high power (250 MW), high neutron flux research reactor operating in the United States. Powered with highly enriched uranium (HEU), the ATR has a maximum unperturbed thermal neutron flux rating of 1.0 x 1015 n/cm2–s. Because of its high power and large test volumes located in high flux areas, the ATR is an ideal candidate for assessing the feasibility of converting an HEU driven reactor to a low-enriched core. A detailed plate-by-plate MCNP ATR full core model has been developed and validated for the low-enriched uranium (LEU) fuel conversion feasibility study. Using this model, an analysis has been performed to determine the LEU density and U-235 enrichment required in the fuel meat to yield equivalent K-eff versus effective full power days (EFPDs) between the HEU and LEU cores. This model has also been used to optimize U-235 content of the LEU core, minimizing the differences in K-eff and heat flux profile between the HEU and LEU cores at 115 MW total core power for 125 EFPDs. The LEU core conversion feasibility study evaluated foil type (U-10Mo) fuel with the LEU reference design of 19.7 wt% U-235 enrichment. The LEU reference design has a fixed fuel meat thickness of 0.330 mm and can sustain the same operating cycle length as the HEU fuel. Heat flux and fission power density are parameters that are proportional to the fraction of fission power deposited in fuel. Thus, the accurate determination of the fraction of fission power deposited in the fuel is important to ATR nuclear safety. In this work, a new approach was developed and validated, the Tally Fuel Cells Only (TFCO) method. This method calculates and compares the fission power deposition fraction between HEU and LEU fuel plates. Due to the high density of the U-10Mo LEU fuel, the fission ?-energy deposition fraction is 37.12%, which is larger than the HEU’s ?-energy deposition fraction of 19.7%. As a result, the fuel decay heat cooling will need to be improved. During the power operation, the total fission energy (200 MeV per fission) deposition fraction of LEU and HEU are 90.9% and 89.1%, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The NASA "PERS" Program: Solid Polymer Electrolyte Development for Advanced Lithium-Based Batteries

In fiscal year 2000, The National Aeronautics and Space Administration (NASA) and the Air Force Research Laboratory (AFRL) established a collaborative effort to support the development of polymer-based, lithium-based cell chemistries and battery technologies to address the next generation of aerospace applications and mission needs. The ultimate objective of this development program, which was referred to as the Polymer Energy Rechargeable System (PERS), was to establish a world-class technology capability and U.S. leadership in polymer-based battery technology for aerospace applications. Programmatically, the PERS initiative exploited both interagency collaborations to address common technology and engineering issues and the active participation of academia and private industry. The initial program phases focused on R&D activities to address the critical technical issues and challenges at the cell level. Out of a total of 38 proposals received in response to a NASA Research Announcement (NRA) solicitation, 18 proposals (13 contracts and 5 grants) were selected for initial award to address these technical challenges. Brief summaries of technical approaches, results and accomplishments of the PERS Program development efforts are presented. With Agency support provided through FY 2004, the PERS Program efforts were concluded in 2005, as internal reorganizations and funding cuts resulted in shifting programmatic priorities within NASA. Technically, the PERS Program participants explored, to various degrees over the lifetime of the formal program, a variety of conceptual approaches for developing and demonstrating performance of a viable advanced solid polymer electrolyte possessing the desired attributes, as well as several participants addressing all components of an integrated cell configuration. Programmatically, the NASA PERS Program was very successful, even though the very challenging technical goals for achieving a viable solid polymer electrolyte material or the overall envisioned long-term, program objectives were not met due to funding reductions. The NASA PERS Program provided research opportunities and generated and disseminated a wealth of new scientific knowledge and technical competencies within the polymer electrolyte area.

Baldwin, Richard S.↗

Microglia are implicated in the development of paclitaxel chemotherapy-associated cognitive impairment in female mice

Chemotherapy remains a mainstay in the treatment of many types of cancer even though it is associated with debilitating behavioral side effects referred to as “chemobrain,” including difficulty concentrating and memory impairment. The predominant hypothesis in the field is that systemic inflammation drives these cognitive impairments, although the brain mechanisms by which this occurs remain poorly understood. Here, we hypothesized that microglia are activated by chemotherapy and drive chemotherapy-associated cognitive impairments. To test this hypothesis, we treated female C57BL/6 mice with a clinically-relevant regimen of a common chemotherapeutic, paclitaxel (6 i.p. doses at 30 mg/kg), which impairs memory of an aversive stimulus as assessed via a contextual fear conditioning (CFC) paradigm. In this work, paclitaxel increased the percent area of IBA1 staining in the dentate gyrus of the hippocampus. Moreover, using a machine learning random forest classifier we identified immunohistochemical features of reactive microglia in multiple hippocampal subregions that were distinct between vehicle- and paclitaxel-treated mice. Paclitaxel treatment also increased gene expression of inflammatory cytokines in a microglia-enriched population of cells from mice. Lastly, a selective inhibitor of colony stimulating factor 1 receptor, PLX5622, was employed to deplete microglia and then assess CFC performance following paclitaxel treatment. PLX5622 significantly reduced hippocampal gene expression of paclitaxel-induced proinflammatory cytokines and restored memory, suggesting that microglia play a critical role in the development of chemotherapy-associated neuroinflammation and cognitive impairments. This work provides critical evidence that microglia drive paclitaxel-associated cognitive impairments, a key mechanistic detail for determining preventative and intervention strategies for these burdensome side effects.

60 APPLIED LIFE SCIENCES↗

Preliminary critical experiments validation of a lattice physic code LATC - 14415

Core and System Integrated Engine for design and analysis (COSINE) is an integrated nuclear engineering code package, which is being developed by State Nuclear Power Software Development Center (SNPSDC) in China. A lattice physics code named LATC is included in COSINE.LATC is a 2D, steady-state code for modeling PWR fuel. A WIMS-D 69 group micro library based on ENDF/B-VI is used and there are two transportation methods in LATC, such as two steps method (collision probability method for cell homogenization, discrete coordinate method for assembly homogenization) and one step method (MOC). The UO{sub 2} fuel assembly, which may contain guide tubes, burnable poisons such as Integral Fuel Burnable Absorbers (IFBA) / Wet Annular Burnable Absorbers (WABA)/ Pyrexes or control rods etc, can be calculated in LATC. LATC provides the required cross-section data for the core physics simulator analysis code in COSINE. In order to evaluate the quality of the LATC, a strategy of validation is researched and applied to the LATC. Firstly, a validation requirement analysis is performed, and the corresponding critical experiments are collected, and then a critical experimental matrix considering the variety of fuel enrichments, fuel pitch and water to uranium ratio is generated. Finally, a comparison of results between LATC using collision probability and discrete coordinate method and critical experiments are made to make sure that the code works well. According to the validation strategy discussed above, the preliminary validation is carried out and critical experiments are calculated according to the critical experimental matrix and results from LATC code are compared with reference results. The result shows that the calculated results agree well with critical experiments, and do not indicate any significant trends with respect to the various conditions considered. (authors)

42 ENGINEERING↗

PyProcar: A Python library for electronic structure pre/post-processing

The PyProcar Python package plots the band structure and the Fermi surface as a function of site and/or s,p,d,f - projected wavefunctions obtained for each k-point in the Brillouin zone and band in an electronic structure calculation. This can be performed on top of any electronic structure code, as long as the band and projection information is written in the PROCAR format, as done by the VASP and ABINIT codes. PyProcar can be easily modified to read other formats as well. This package is particularly suitable for understanding atomic effects into the band structure, Fermi surface, spin texture, etc. PyProcar can be conveniently used in a command line mode, where each one of the parameters define a plot property. In the case of Fermi surfaces, the package is able to plot the surface with colors depending on other properties such as the electron velocity or spin projection. Furthermore, the mesh used to calculate the property does not need to be the same as the one used to obtain the Fermi surface. A file with a specific property evaluated for each k-point in a k-mesh and for each band can be used to project other properties such as electron–phonon mean path, Fermi velocity, electron effective mass, etc. Another existing feature refers to the band unfolding of supercell calculations into predefined unit cells.

97 MATHEMATICS AND COMPUTING↗

An In-Depth Exploration of the Electrochemical Oxygen Reduction Reaction (ORR) Phenomenon on Carbon-Based Catalysts in Alkaline and Acidic Mediums

Detailed studies of the electrochemical oxygen reduction reaction (ORR) on catalyst materials are crucial to improving the performance of different electrochemical energy conversion and storage systems (e.g., fuel cells and batteries), as well as numerous chemical synthesis processes. In the effort to reduce the loading of expensive platinum group metal (PGM)-based catalysts for ORR in the electrochemical systems, many carbon-based catalysts have already shown promising results and numerous investigations on those catalysts are in progress. Most of these studies show the catalyst materials’ ORR performance as current density data obtained through the rotating disk electrode (RDE), rotating ring-disk electrode (RRDE) experiments taking cyclic voltammograms (CV) or linear sweep voltammograms (LSV) approaches. However, the provided descriptions or interpretations of those data curves are often ambiguous and recondite which can lead to an erroneous understanding of the ORR phenomenon in those specific systems and inaccurate characterization of the catalyst materials. In this paper, we presented a study of ORR on a newly developed carbon-based catalyst, the nitrogen-doped graphene/metal-organic framework (N-G/MOF), through RDE and RRDE experiments in both alkaline and acidic mediums, taking the LSV approach. The functions and crucial considerations for the different parts of the RDE/RRDE experiment such as the working electrode, reference electrode, counter electrode, electrolyte, and overall RDE/RRDE process are delineated which can serve as guidelines for the new researchers in this field. Experimentally obtained LSV curves’ shapes and their correlations with the possible ORR reaction pathways within the applied potential range are discussed in depth. We also demonstrated how the presence of hydrogen peroxide (H2O2), a possible intermediate of ORR, in the alkaline electrolyte and the concentration of acid in the acidic electrolyte can maneuver the ORR current density output in compliance with the possible ORR pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code

Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the GEANT 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from GEANT 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LET{sub t} and dose-averaged LET, LET{sub d}) using GEANT 4 for different tracking step size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LET{sub t} and LET{sub d} of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LET{sub t} but significant for LET{sub d}. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in GEANT 4 can result in incorrect LET{sub d} calculation results in the dose plateau region for small step limits. The erroneous LET{sub d} results can be attributed to the algorithm to determine fluctuations in energy deposition along the tracking step in GEANT 4. The incorrect LET{sub d} values lead to substantial differences in the calculated RBE. Conclusions: When the GEANT 4 particle tracking method is used to calculate the average LET values within targets with a small step limit, such as smaller than 500 μm, the authors recommend the use of LET{sub t} in the dose plateau region and LET{sub d} around the Bragg peak. For a large step limit, i.e., 500 μm, LET{sub d} is recommended along the whole Bragg curve. The transition point depends on beam parameters and can be found by determining the location where the gradient of the ratio of LET{sub d} and LET{sub t} becomes positive.

60 APPLIED LIFE SCIENCES↗

Applicability of the Nasa Galactic Cosmic Ray Simulator for Mice, Rats, and Minipigs

Space radiation poses multiple health risks to astronauts including cancer, cardiovascular disease, and damage to the central nervous system. Radiation from galactic cosmic rays (GCR) is the main source of these risks for missions beyond low Earth orbit to the moon and beyond. A galactic cosmic ray simulator (GCRsim) was developed at the NASA Space Radiation Laboratory to better understand and mitigate these risks by simulating the complex mixed field of the GCR environment at a ground-based facility. The GCRsim delivers a radiation field to cell and animal models in a laboratory setting that is comparable to the shielded radiation environment within internal organs of astronauts in deep space missions. Previous verification studies using Monte Carlo simulations with mouse (Digimouse) and rat (Digirat) digital phantoms showed that the GCRsim yields acceptable dose homogeneity within the internal organs of these animals. Spectral characteristics of the intended space radiation environment are also accurately reproduced at radiosensitive sites in both phantoms. In this work, similar Monte Carlo simulations were performed in a minipig model (Digipig) to show the applicability and limitations of the current GCRsim for larger animal model systems. The results showed dose homogeneity in internal organs of the three animal models with GCRsim irradiation. While slightly lower average doses were seen in the minipig compared to the external beam dose, the individual voxel doses in slices of the phantoms were found to be within 6%–8% of the average voxel dose, establishing that the GCRsim can still provide a relatively homogeneous irradiation within larger animals. Furthermore, simulated dose and fluence spectral results across the relevant linear energy transfer (LET) range agreed well with the reference field in the most relevant regions of the spectra, further verifying that the GCRsim beam represents the reference field in larger animals.

Galactic cosmic rays↗

Examples of X-Ray Characterization Techniques in Energy Storage Research

Lithium-ion batteries have revolutionized the portable electronics and transportation sectors. Their performance is often critically dependent on the crystal structures of the anode and cathode electrode materials, which must enable the transport and reversible storage of lithium ions into and out of the lattice. Because lithium is a low-Z element, characterization of materials for lithium-ion batteries can be particularly challenging. Regardless, X-ray techniques enable analysis of material structures to better understand how battery materials perform and degrade, particularly when combined with other materials characterization and electrochemical characterization techniques. While X-ray techniques are most often used in battery research for phase identification of crystal structures, X-ray characterization techniques are also used for a wide variety of other purposes. I will discuss several examples from my research with various collaborators on several projects that highlight the impact that X-ray characterization techniques can have on battery research. The first example will focus on low-temperature microwave-assisted solvothermal synthesis of vanadium-doped LiFePO4 cathode materials for lithium-ion batteries. (1,2) Through a combination of electrochemical and materials characterization, we determined that low temperature synthesis resulted in metastable phases that enabled incorporation of higher dopant levels than resulting from high-temperature synthesis of thermodynamically stable phases. Rietveld refinement of X-ray diffraction data enabled understanding of how lattice parameters changed with doping levels and synthesis temperature. X-ray absorption near edge spectroscopy enabled understanding of the vanadium and iron oxidation states to confirm how vacancies in the structure caused by doping were charge compensated. This was important to understand because the literature suggests doping can improve LiFePO4 electrical conductivity, which improves battery charge and discharge rates. The second example will focus on understanding residual strain in lithium metal anodes. Lithium-ion batteries typically use graphite anodes, but the charge-storage capacity can be theoretically improved ~10x by using lithium metal as the anode material instead. However, lithium anodes suffer from growth of high-aspect-ratio features, such as dendrites, that can pierce nanoporous polymer separators and lead to short circuits and fires. External pressure is commonly applied to cells to enable better morphological control. We hypothesized that applied pressure may promote strain and possibly work hardening during electrochemical cycling, which motivated us to look for evidence of residual strain in lithium metal cycled under applied pressure using X-ray diffraction and sin2(..psi..) analysis. We found that lithium electrodeposited under high pressure exhibited in-plane compressive strain and that that lithium electrodeposited under low pressure did not. (3) The residual strain that accompanies electrodeposition under high pressure may lead to work hardening, which may explain how a soft metal like lithium can puncture separators and why higher pressure does not always decrease short circuits. (4-6) References: 1) Harrison, K. L.; Manthiram, A. Microwave-Assisted Solvothermal Synthesis and Characterization of Metastable LiFe1- x (VO) x PO4 Cathodes. Inorganic chemistry 2011, 50(8), 3613-3620. 2) Harrison, K. L.; Bridges, C. A.; Paranthaman, M. P.; Segre, C. U.; Katsoudas, J.; Maroni, V. A.; Idrobo, J. C.; Goodenough, J. B.; Manthiram, A. Temperature Dependence of Aliovalent-Vanadium Doping in LiFePO4 Cathodes. Chemistry of Materials 2013, 25(5), 768-781. 3) Rodriguez, M. A.; Harrison, K. L.; Goriparti, S.; Griego, J. J.; Boyce, B. L.; Perdue, B. R. Use of a Be-Dome Holder for Texture and Strain Characterization of Li Metal Thin Films via Sin2 (..psi..) Methodology. Powder Diffraction 2020, 35(2), 89-97. 4) Jungjohann, K. L.; Gannon, R. N.; Goriparti, S.; Randolph, S. J.; Merrill, L. C.; Johnson, D. C.; Zavadil, K. R.; Harris, S. J.; Harrison, K. L. Cryogenic Laser Ablation Reveals Short-Circuit Mechanism in Lithium Metal Batteries. ACS Energy Letters 2021, 6(6), 2138-2144. 5) Harrison, K. L.; Merrill, L. C.; Long, D. M.; Randolph, S. J.; Goriparti, S.; Christian, J.; Warren, B.; Roberts, S. A.; Harris, S. J.; Perry, D. L. Cryogenic Electron Microscopy Reveals That Applied Pressure Promotes Short Circuits in Li Batteries. Iscience 2021, 24(12). 6) Harrison, K. L.; Goriparti, S.; Merrill, L. C.; Long, D. M.; Warren, B.; Roberts, S. A.; Perdue, B. R.; Casias, Z.; Cuillier, P.; Boyce, B. L. Effects of Applied Interfacial Pressure on Li-Metal Cycling Performance and Morphology in 4 M LiFSI in DME. ACS Applied Materials & Interfaces 2021, 13(27), 31668-31679.

batteries↗