Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Retrieving images from tarnished daguerreotypes using X-ray fluorescence imaging with an X-ray micro beam with tunable energy

We report recent observations using a synchrotron X-ray micro-beam to retrieve images from tarnished 19th century daguerreotypes. We confirm that high quality image can always be retrieved from tarnished plates using Hg L α XRF as long as the bulk of the image particles and their distribution remains intact. We also report results from using tunable tender X-rays (2 - 7 keV) to conduct imaging in high vacuum at energy above the Ag L-edge and the Hg M-edge, extracting images using Ag L α and Hg M α , respectively among others (e.g., S to track corrosion). Images obtained with the surface sensitive total electron yield (TEY) and the bulk sensitive fluorescence yield (FLY) as well as corresponding micro-XANES are reported. Flux tolerance to high intensity X-beam is also explored. These results and their implications for cultural heritage research are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Evolution of Photoexcited Methylcobalamin toward a CarH-like Metastable State: Evidence from Time-Resolved X-ray Absorption and X-ray Emission

CarH is a protein photoreceptor that uses a form of B 12 , adenosylcobalamin (AdoCbl), to sense light via formation of a metastable excited state. Aside from AdoCbl bound to CarH, methylcobalamin (MeCbl) is the only other example – to date – of photoexcited cobalamins forming metastable excited states with lifetimes of nanoseconds or longer. The UV-visible spectra of the excited states of MeCbl and AdoCbl bound to CarH are similar. We have used transient Co K-edge X-ray absorption and X-ray emission spectroscopies in conjunction with transient absorption spectroscopy in the UV–visible region to characterize the excited states of MeCbl. These data show that the metastable excited state of MeCbl has a slightly expanded corrin ring and increased electron density on the cobalt, but only small changes in the axial bond lengths. Finally, this is similar to changes seen previously for CarH, suggesting that MeCbl may be a good model for AdoCbl in CarH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Ab Initio Methods for L-edge X-ray Absorption Spectroscopy

The theoretical prediction of X-ray absorption spectra (XAS) has become common- place in electronic structure theory. The ability to better model and understand L-edge spectra is of great interest in the study of transition metal complexes and a wide variety of solid state materials. However, until recently few rst-principles works have mod- eled L-edge XAS due to the presence of strong spin-orbit coupling in the 2p orbitals which splits the observed peaks into multiple groups of features. Therefore, a proper description of spin-orbit coupling is vital for the successful prediction of L-edge spectra. A number of new approaches that incorporate spin-orbit coupling have recently made advances in the computation of L-edge spectra. In this review, we describe recent work in computational L-edge XAS and how these methods may continue to improve in the future. Comparison of the advantages and disadvantages of the various approaches are considered, with special attention to not only the computational cost of the level of theory, but also the various approaches that can be used to compute the absorption spectra with a large number of high energy excited states.

Kasper, Joseph M.↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Reflectivity Around the Gold L-Edges of X-Ray Reflector of the Soft X-Ray Telescope Onboard ASTRO-H

We report the atomic scattering factor in the 11.215.4 keV for the ASTRO-H Soft X-ray Telescope (SXT) obtained in the ground based measurements. The large effective area of the SXT covers above 10 keV. In fact, the flight data show the spectra of the celestical objects in the hard X-ray band. In order to model the area, the reflectivity measurements in the 11.2-15.4 keV band with the energy pitch of 0.4-0.7 eV were made in the synchrotron beamline Spring-8 BL01B1. We obtained atomic scattering factors f1 and f2 by the curve fitting to the reflectivities of our witness sample. The edges associated with the golds L-I, II, and III transitions are identified, of which the depths are found to be roughly 60 percent shallower than those expected from the Henke's atomic scattering factor.

X-rays↗

Miniaturization in X-Ray and Gamma-Ray Spectroscopy

The paper presents advances in two new sensor and miniaturized associated electronics technologies which, when combined, can allow for very significant miniaturization, and the reduction of weight and power consumption in x-ray and gamma-ray spectroscopy systems.

Mercuric↗

Complex Variations in X-ray Polarization in the X-ray pulsar LS V +44 17 / RX J0440.9+4431

We report on Imaging X-ray polarimetry explorer (IXPE) observations of the Be-transient X-ray pulsar LS V+44 17/RX J0440.9+4431 made at two luminosity levels during the giant outburst in January–February 2023. Considering the observed spectral variability and changes in the pulse profiles, the source was likely caught in supercritical and subcritical states with significantly different emission-region geometry, associated with the presence of accretion columns and hot spots, respectively. We focus here on the pulse-phase-resolved polarimetric analysis and find that the observed dependencies of the polarization degree and polarization angle (PA) on the pulse phase are indeed drastically different for the two observations. The observed differences, if interpreted within the framework of the rotating vector model (RVM), imply dramatic variations in the spin axis inclination, the position angle, and the magnetic colatitude by tens of degrees within the space of just a few days. We suggest that the apparent changes in the observed PA phase dependence are predominantly related to the presence of an unpulsed polarized component in addition to the polarized radiation associated with the pulsar itself. We then show that the observed PA phase dependence in both observations can be explained with a single set of RVM parameters defining the pulsar’s geometry. We also suggest that the additional polarized component is likely produced by scattering of the pulsar radiation in the equatorial disk wind.

RX J0440.9+4431↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

Anomalous X-Ray Scattering and Extended X-Ray Absorption Fine Structure Study of the Local Structure of CrFeCoNiMo x (x = 0.11, 0.18, and 0.23) High-Entropy Alloys

Anomalous x-ray scattering (AXS) and extended x-ray absorption fine structure (EXAFS) were used to determine the local structure of Mo in CrFeCoNiMo x (x = 0.11, 0.18, and 0.23), a high-entropy alloy with a face-centered cubic (FCC) lattice. No superlattice peaks were observed down to the 10 -4 intensity level. This observation along with the nearly constant decrease of the FCC diffraction peaks above the Mo K absorption edge suggests that Mo atoms have no preferred site occupancy in the FCC lattice. Modeling of the EXAFS data suggests a local chemical order in CrFeCoNiMo x , where in Mo-rich samples (e.g., x = 0.23), Mo atoms are preferably surrounded by lighter atoms, such as Cr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed synchrotron X-ray imaging of directed energy deposition of titanium: effects of processing parameters on the formation of entrapped-gas pores

Laser based directed energy deposition (DED) is a competitive method for repairing and remanufacturing metallic parts used in numerous industries including aerospace and biomedical. However, the numerous dynamic phenomena associated with the DED process often result in defects such as entrapped-gas pores, lack of fusion, and undesirable anisotropic properties. The entrapped-gas pore, being one of the most common issues, not only influences melt-pool dynamics but also reduces the fabrication quality and mechanical properties of parts fabricated by the DED process. To reduce and further understand this issue, the real-time observation of the pore formation process needs to be studied first. To directly observe the phenomena in the melt pool, high-speed techniques are needed because rapid solidification leads to rapid pore formation and movement. In-situ high-speed X-ray has been proven to be an effective method in investigating the melt pool dynamics and pore formation mechanisms in the laser powder bed fusion process, in which the fabrication process is quite different from that in DED. Here, the high-speed X-ray method is extended to study the formation of entrapped-gas pores. The real-time formation and quantitative analysis of pores under each set of processing parameters (particle velocity, laser power, and spot welding dwelling time of stationary laser) in the DED process are investigated. We found that the DED with a higher particle velocity (3.19 m/s) produced a smaller average pore size of 27.8 µm and a lower pore area fraction of 0.52%. The DED under lower laser power (156 W) generated a smaller average pore size of 20.3 µm and a lower pore area fraction of 1.94%. The shorter dwelling time (10 ms) benefited the decrease of both average pore size and pore area fraction.

Defect↗

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗