Raman Life Detection Instrument Development for Icy Worlds

The objective of this project is to develop a compact, high sensitivity Raman sensor for detection of life signatures in a flow cell configuration to enable bio-exploration and life detection during future mission to our Solar Systems Icy Worlds. The specific project objectives are the following: 1) Develop a Raman spectroscopy liquid analysis sensor for biosignatures; 2) Demonstrate applicability towards a future Enceladus or other Icy Worlds missions; 3) Establish key parameters for integration with the ARC Sample Processor for Life on Icy Worlds (SPLIce); 4) Position ARC for a successful response to upcoming Enceladus or other Icy World mission instrument opportunities.

astrobiolog↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Wernet, Mark P.↗

Context Imaging Raman Spectrometer

Methods and systems for Raman spectroscopy and context imaging are disclosed. One or two lasers can be used to excite Raman scattering in a sample, while a plurality of LEDs can illuminate the sample at a different wavelength. The LED light is collected by a lenslet array in order to enable a high depth of field. Focusing of the image can be carried out at specific points of the image by processing the light collected by the lenslet array.

Lambert, James L.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

Carbon fiber classification using raman spectroscopy

Carbon fiber characterization processes are described that include multi-condition Raman spectroscopy-based examination combined with multivariate data analyses. Methods are a nondestructive material characterization approach that can provide predictions as to carbon fiber bulk physical properties, as well as identification of unknown carbon fiber materials for quality control purposes. The framework of the multivariate analysis methods includes a principal component-based identification protocol including comparison of Raman spectral data from an unknown carbon fiber with a data library of multiple principal component spaces.

Houk, Amanda L.↗

Selective Detection in Impulsive Low-Frequency Raman Imaging Using Shaped Probe Pulses

Impulsive stimulated Raman scattering (ISRS) using a single short femtosecond pump pulse to excite molecular vibrations offers an elegant pump-probe approach to perform vibrational imaging below 200 cm –1 . One shortcoming of ISRS is its inability to offer vibrational selectivity as all the vibrational bonds whose frequencies lie within the short pump-pulse bandwidth are excited. To date, several coherent control techniques have been explored to address this issue and selectively excite a specific molecular vibration by shaping the pump pulse. There has not been any systematic work that reports an analogous shaping of the probe pulse to implement preferential detection. In this work, we focus on vibrational imaging and report vibrational selective detection by shaping the probe pulse in time. Here, we demonstrate numerically and experimentally two pulse-shaping strategies with one functioning as a vibrational notch filter and the other functioning as a vibrational low-pass filter. This enables fast (25 μs/pixel) and selective hyperspectral imaging in the low-frequency regime (< 200 cm –1 ).

74 ATOMIC AND MOLECULAR PHYSICS↗

Impact of Surface Enhanced Raman Spectroscopy in Catalysis

Catalysis stands as an indispensable cornerstone of modern society, underpinning the production of over 80% of manufactured goods and driving over 90% of industrial chemical processes. As the demand for more efficient and sustainable processes grows, better catalysts are needed. Understanding the working principles of catalysts is key, and over the last 50 years, surface-enhanced Raman Spectroscopy (SERS) has become essential. Discovered in 1974, SERS has evolved into a mature and powerful analytical tool, transforming the way in which we detect molecules across disciplines. In catalysis, SERS has enabled insights into dynamic surface phenomena, facilitating the monitoring of the catalyst structure, adsorbate interactions, and reaction kinetics at very high spatial and temporal resolutions. This review explores the achievements as well as the future potential of SERS in the field of catalysis and energy conversion, thereby highlighting its role in advancing these critical areas of research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mixed ortho- H 2 and para- H 2 clusters studied by vibrational coherent anti-Stokes Raman spectroscopy

The search for macroscopic quantum effects, including superfluidity, in molecular hydrogen is mostly focused on its parahydrogen (p-H 2 ) nuclear spin modification because of weaker intermolecular interaction compared to orthohydrogen (o-H 2 ), both modifications being bosonic. In this work, mixed clusters of o-H 2 and p-H 2 containing similar to 10(4) molecules are prepared by supersonic expansion with helium and studied by vibrational coherent anti-Stokes Raman scattering (CARS) spectroscopy. At similar experimental conditions the neat p-H 2 clusters avoid freezing and remain fluid at 1-2 K, which is predicted to be the realm of their superfluid behavior [Phys. Rev. Lett. 101, 205301 (2008)]. Dependence of the vibrational frequencies and intensities of the main CARS peaks due to o-H 2 and p-H 2 versus the ratio of the o-H 2 and p-H 2 concentrations in the expanding gas suggests that o-H 2 and p-H 2 molecules are uniformly mixed in the interior of the clusters. A weak spectral feature at 4157 cm -1 that appears independent of the concentration ratio is assigned to the outer shell of the clusters enriched with p-H 2 molecules. Although the phase of the mixed clusters could not be unambiguously identified, the shift of the vibrational frequencies with respect to the bulk solid is consistent with the liquid state of the clusters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Longitudinal Single‐Cell Imaging of Engineered Strains with Stimulated Raman Scattering to Characterize Heterogeneity in Fatty Acid Production

Abstract Understanding metabolic heterogeneity is critical for optimizing microbial production of valuable chemicals, but requires tools that can quantify metabolites at the single‐cell level over time. Here, longitudinal hyperspectral stimulated Raman scattering (SRS) chemical imaging is developed to directly visualize free fatty acids in engineered Escherichia coli over many cell cycles. Compositional analysis is also developed to estimate the chain length and unsaturation of the fatty acids in living cells. This method reveals substantial heterogeneity in fatty acid production among and within colonies that emerges over the course of many generations. Interestingly, the strains display distinct types of production heterogeneity in an enzyme‐dependent manner. By pairing time‐lapse and SRS imaging, the relationship between growth and production at the single‐cell level are examined. The results demonstrate that cell‐to‐cell production heterogeneity is pervasive and provides a means to link single‐cell and population‐level production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous assessment of metabolic activity of mitochondria using resonance Raman microspectroscopy

Dysfunctional mitochondrial activity can lead to a variety of different diseases. As such, there exists a need to quantify changes in mitochondria function as it relates to these specific diseased states. Here, we present the use of resonance Raman (RR) spectroscopy as a tool to determine changes in isolated mitochondrial activity. RR spectroscopy, using 532 nm as the excitation source, specifically provides information on the reduction and oxidation (RedOx) state of cytochrome c, which is determined by the activity of protein complexes in the electron transport chain. In this model, injection of the substrate succinate into the mitochondrial sample is used to drive the electron transport chain, which causes a subsequent change in cytochrome c RedOx state. This change in RedOx state is tracked by RR spectroscopy. We report this tool gives real-time information on the rise and fall of the amount of reduced cytochrome c within the mitochondrial sample, providing a method for rapid assessment of mitochondrial metabolism that has broad applications in both basic science and medical research.

59 BASIC BIOLOGICAL SCIENCES↗

Imprinting a Three-Dimensional Skyrmion in a Bose–Einstein Condensate Via a Raman Process

We describe an experimental protocol for the creation of a three-dimensional topological defect, a skyrmion, in a pseudo-spin-1/2 Bose–Einstein condensate (BEC) confined in a spin-independent harmonic trap. We show that one can imprint the skyrmion on the BEC within a few tens of microseconds using a Raman process with the structured laser fields. We numerically solved the mean-field Gross– Pitaevskii equation to examine our imprinting scheme and found that all parameters we use are experimentally feasible.

3D Skyrmion↗

Plasma-assisted deflagration to detonation transition in a microchannel with fast-frame imaging and hybrid fs/ps coherent anti-Stokes Raman scattering measurements

Our study examines kinetic enhancement by nanosecond dielectric barrier discharge (ns-DBD) plasma on fuellean dimethyl ether (DME), oxygen (O 2 ), and argon (Ar) premixtures during deflagration to detonation transition (DDT) experiments in a microchannel. Non-equilibrium plasma produces active species and radicals and creates fast and slow heating of a mixture to promote ignition due to electronic and vibrational excitation. Experiments have been conducted to examine the influence of the plasma discharge on the premixture and on the resultant deflagration to detonation transition (DDT) onset time and distance through the use of high speed imaging and one-dimensional, two-beam, femtosecond/picosecond, coherent anti-Stokes Raman scattering (CARS). A highspeed camera is used to trace the time histories of flame front position and velocity and to identify the dynamics and onset of DDT. The results show that plasma discharge can nonlinearly affect the onset time and distance of DDT. It is shown that a small number of plasma discharge pulses prior to ignition result in reduced DDT onset time and distance by 60% and 40%, respectively, when compared to the results without pre-excitation by ns discharges. The results also show that an increase of plasma discharge pulses results in an extended DDT onset time and distance of 224% and 94%, respectively. Time history of the deflagration wave speed of DME and the analysis of ignition timescale under the choking condition of the deflagration front suggest low temperature ignition may play a role for DME near the isobaric choking condition of the burned gas and the DDT. Plasmainduced conversion of the reactive mixture was assessed via the O 2 to CO 2 ratio as measured through fs/ps CARS during the DBD discharges. The present experiments demonstrate the ability of non-equilibrium plasma to alter the chemistry of DME/O 2 /Ar premixtures in order to control DDT for applications in advanced propulsion engines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of transverse stimulated Raman scattering in KDP/DKDP in large-aperture plates suitable for polarization control

Transverse stimulated Raman scattering (TSRS) in potassium dihydrogen phosphate (KDP) and deuterated potassium dihydrogen phosphate (DKDP) plates for large-aperture, inertial confinement fusion (ICF)-class laser systems is a well-recognized limitation giving rise to parasitic energy conversion and laser-induced damage. The onset of TSRS is manifested in plates exposed to the ultraviolet section of the beam. TSRS amplification is a coherent process that grows exponentially and is distributed nonuniformly in the crystal and at the crystal surfaces. To understand the growth and spatial distribution of TSRS energy in various configurations, a modeling approach has been developed to simulate the operational conditions relevant to ICF-class laser systems. Specific aspects explored in this work include (i) the behavior of TSRS in large-aperture crystal plates suitable for third-harmonic generation and use as wave plates for polarization control in current-generation ICF-class laser system configurations; (ii) methods, and their limitations, of TSRS suppression and (iii) optimal geometries to guide future designs.

47 OTHER INSTRUMENTATION↗

Understanding Solvation Behavior of the Saturated Electrolytes with Small/Wide-Angle X-ray Scattering and Raman Spectroscopy

Concentrated electrolytes are attracting significant attention because the solvation structures could stabilize the interface, encouraging novel electrolyte development for high-voltage and long-cycle-life batteries. Saturated electrolytes, which have the highest salt concentrations, have been rarely studied because of their shortcomings of high viscosity and low ionic conductivity. Nevertheless, the exciting solvation structure in saturated solution is still worth studying, significantly broadening the comprehensive understanding of the solvation processes. In this work, we investigate the saturated lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) dissolved in seven different organic solvents, including propylene carbonate (PC), tetrahydrofuran (THF), acetonitrile (ACN), dimethylformamide (DMF), 1,2-dimethoxyethane (DME), diethylene glycol dimethyl ether (Diglyme), and tetraethylene glycol dimethyl ether (Tetraglyme). The combined small/wide-angle X-ray scattering and Raman spectroscopy are employed to study the global and local solvation structure. Here, this work demonstrates a method for detecting the structure of liquids, which will facilitate the study of structure–performance relationships and the screening of new electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Raman-Interfering Polyoxoanions for Process Analysis: Comparison of Different Chemometric Models and a Demonstration on Real Hanford Waste

The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.

54 ENVIRONMENTAL SCIENCES↗

Spatio-Spectral Characterization of Multipolar Plasmonic Modes of Au Nanorods via Tip-Enhanced Raman Scattering

Tip-enhanced Raman (TER) spectral images of 4-thiobenzonitrile-coated Au nanorods map the spatial profiles and trace the resonances of dipolar and multipolar plasmonic modes that are characteristic of the imaged particles. For any particular rod, we observe sequential transitions between high-order modes at low frequency shifts and lower-order modes at higher frequencies. We also notice that higher-order modes (up to $m$ = 4) are generally observed for long rods as compared to their shorter analogues, where longitudinal dipolar resonances ($m$ = 1) are observable. In effect, this research adds a new dimension to local optical field mapping via TERS, which we have previously explored. Not only can the magnitudes, vector components, local/nonlocal characters of local optical fields be imaged through molecular TERS, but spatially varying local optical resonances are also direct observables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗