Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Pump depletion in Raman lasing in a graded index multimode fibre

We examine multimode diode laser pump depletion in a graded index multimode (MM) fibre Raman laser generating a high-quality Stokes beam. Spatial ‘hole burning’ in the transmitted pump beam is demonstrated. A balance model is constructed for interaction of the pump and Stokes waves in the MM Raman laser. Analytical formulas are derived and used in calculations demonstrating qualitative agreement with experimental data. The origin of the observed quantitative discrepancies is discussed. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Toroidal modeling of plasma flow damping and density pump-out by RMP during ELM mitigation in HL-2A

Reduction of both the plasma density and toroidal flow speed, due to application of the predominantly n = 1 (n is the toroidal mode number) resonant magnetic perturbation (RMP) for controlling the edge localized mode in the HL-2A tokamak, is numerically investigated utilizing the quasi-linear initial-value code MARS-Q (Liu et al 2013 Phys. Plasmas 20 042503). Simulation results reveal that the neoclassical toroidal viscosity (NTV) due to three dimensional fields plays the key role in modifying the plasma momentum and particle transport in the HL-2A discharge. By comparing the modeling results with the measured density pump-out in the experiment, the electron NTV particle flux model, in combination with the free-boundary condition for the axisymmetric change of the density at the plasma edge, is found to yield the best agreement in terms of both the pump-out level and the overall time scale. Further sensitivity studies show that the simulated density pump-out level is reasonably robust against variations in the model assumptions, including the particle diffusion model and the non-ambipolar versus ambipolar NTV particle flux. The latter however affects the time scale for reaching the steady state solution. Finally, it is found that the plasma edge-peeling response, the NTV torque, as well as the plasma momentum and particle transport, all are sensitive to the toroidal phase difference between the upper and lower rows of the RMP coil currents in HL-2A, with the 30 ∘ coil phasing producing the minimal side effects on the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Survival estimates across five life stages of redfin ( Perca fluviatilis ) exposed to simulated pumped-storage hydropower stressors

The global prevalence of pumped-storage hydropower (PSH) is expected to grow exponentially as countries transition to renewable energy sources. Compared to conventional hydropower, little is currently known regarding PSH impacts on aquatic biota. This study estimated the survival of five life stages (egg, two larval stages, juvenile and adult) of redfin (European) perch (Perca fluviatilis) following passage through a PSH facility during the pumping phase. This was achieved by simulating the individual stressors expected to occur during passage through a 2000-MW PSH facility using laboratory-simulated (shear strain and extreme compression) and modelling (blade strike, BS) approaches. Our results indicate that redfin could survive the shear, pressure and BS stressors expected within the PSH facility, but impacts varied among life stages. Juvenile survival was >70% across all shear strain rates, while the survival of eggs and larvae declined markedly as strain rate increased. All life stages had high survival when exposed to rapid compression and BS. The high survival of redfin to the stressors tested suggests the PSH facility could facilitate the passage of redfin during the pumping phase from the lower to the higher elevation reservoir. This outcome would be welcomed in situations where the species is native, but could have adverse implications for the conservation of native biota where the species is considered a pest.

59 BASIC BIOLOGICAL SCIENCES↗

Theory of tunneling between two-dimensional electron layers driven by spin pumping: Adiabatic regime and beyond

Tunneling spectroscopy between parallel two-dimensional (2D) electronic systems provides a powerful method to probe the underlying electronic properties by measuring tunneling conductance. Here, in this work, we present a theoretical framework for spin transport in 2D-to-2D tunneling systems, driven by spin pumping. This theory applies to a vertical heterostructure where two layers of metallic 2D electron systems are separated by an insulating barrier, with one layer exchange coupled to a magnetic layer driven at resonance. Utilizing a nonperturbative Floquet-Keldysh formalism, we derive general expressions for the tunneling spin and charge currents across a broad range of driving frequencies, extending beyond the traditional adiabatic pumping regime. At low frequencies, we obtain analytical results that recover the known behaviors in the adiabatic regime. However, at higher frequencies, our numerical findings reveal significant deviations in the dependence of spin and charge currents on both frequency and precession angle. This work offers fresh insights into the role of magnetization dynamics in tunneling transport, opening up new avenues for exploring nonadiabatic spin pumping phenomena.

Green's function methods↗

Time-resolved resonant inelastic x-ray scattering in a pumped Mott insulator

Collective excitations contain rich information about photoinduced transient states in correlated systems. In a Mott insulator, charge degrees of freedom are frozen, but can be activated by photodoping. The energy-momentum distribution of the charge excitation spectrum reflects the propagation of charge degrees of freedom and provides information about the interplay among various intertwined instabilities on the timescale set by the pump. To reveal charge excitations out of equilibrium, here we simulate time-resolved x-ray absorption and resonant inelastic x-ray scattering using a Hubbard model. After pumping, the former resolves photodoping, while the latter characterizes the formation, dispersion, weight, and nonlinear effects of collective excitations. Intermediate-state information from time-resolved resonant inelastic x-ray scattering (trRIXS) can be used to decipher the origin of these excitations, including bimagnons, Mott-gap excitations, doublon and single-electron in-gap states, and anti-Stokes relaxation during an ultrafast pump. This paper provides a theoretical foundation for existing and future trRIXS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear optical control of chiral charge pumping in a topological Weyl semimetal

Solids with topologically robust electronic states exhibit unusual electronic and optical properties that do not exist in other materials. A particularly interesting example is chiral charge pumping, the so-called chiral anomaly, in recently discovered topological Weyl semimetals, where simultaneous application of parallel DC electric and magnetic fields creates an imbalance in the number of carriers of opposite topological charge (chirality). Here, using time-resolved terahertz measurements on the Weyl semimetal TaAs in a magnetic field, we optically interrogate the chiral anomaly by dynamically pumping the chiral charges and monitoring their subsequent relaxation of the nonequilibrium state. Theory based on Boltzmann transport shows that the observed effects originate from an optical nonlinearity in the chiral charge pumping process. Our measurements reveal that the nonequilibrium chiral excitation relaxation time is much greater than 1 ns. The observation of terahertz-controlled chiral carriers with long coherence times and topological protection suggests the application of Weyl semimetals for quantum optoelectronic technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topological Charge Pumping in Excitonic Insulators

Here, we show that in excitonic insulators with s-wave electron-hole pairing, an applied electric field (either pulsed or static) can induce a p-wave component to the order parameter, and further drive it to rotate in the s + ip plane, realizing a Thouless charge pump. In one dimension, each cycle of rotation pumps exactly two electrons across the sample. Higher dimensional systems can be viewed as a stack of one-dimensional chains in momentum space in which each chain crossing the Fermi surface contributes a channel of charge pumping. Physics beyond the adiabatic limit, including in particular dissipative effects is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for Suitable Binary Fluid for an Ejector Heat Pump for Domestic Water Heating

Water heating is a major source of energy consumption in the U.S. residential sector. Heat pumps can significantly increase the energy efficiency of water heating. An ejector heat pump (EHP) is a novel, thermally driven heat pump that uses an ejector as a thermocompressor. Choosing suitable working fluids is critical in developing high-performance EHPs. Therefore, this research screens binary fluid pairs (BFPs) for EHPs to produce domestic hot water at a high coefficient of performance (COP). The criteria for screening BFP candidates for EHP water heaters (EHPWHs) are established, and BFP candidates are shortlisted. This study identifies HFE7000, Novec649, HFE7100, HFE7200, and HFE7500 for the primary fluids and RE170, R600a, R600, and R1234ze(Z) for the secondary fluids. The thermodynamic model is employed to investigate the performance of EHPWHs using the shortlisted BFPs under various operating parameters, including the evaporation pressure of the primary working fluid in the high-temperature evaporator and the condensation temperature. In conclusion, the highest heating-cycle COP of 1.328 is achieved by an EHPWH operating with HFE7000/R600 at a condenser temperature of 50 °C and a pressure of 1.69 MPa in the high-temperature evaporator.

42 ENGINEERING↗

Mutations in the proximal binding site and F-loop of AdeJ confer resistance to efflux pump inhibitors

Multidrug efflux is one of the major mechanisms of antibiotic resistance in gram-negative bacteria. Inhibitors of efflux pumps potentiate the activities of antibiotics, and their discovery could lead to new therapeutic options. The AdeIJK pump in Acinetobacter baumannii is a promising target for efflux pump inhibitors (EPIs) due to its high clinical importance and conservation, and several classes of EPIs targeting this and other A. baumannii efflux transporters have been recently reported. However, the mechanisms of action of these EPIs and their resistance liability remain underexplored. Here, we analyzed the impact of site-specific substitutions in the substrate/EPI translocation path of the inner membrane transporter AdeJ on efflux of substrate antibiotics and fluorescent probes and activities of substituted 4,6-diaminoquinoline EPIs. We found that substitutions in amino acid residues located in the entrance cleft (R701) and the flexible loop (E675) of AdeJ lead to resistance specifically against biphenyl-substituted EPIs, whereas the substitution of F178 in the distal binding pocket increased AdeJ sensitivity to certain naphthyl- and biphenyl-substituted EPIs. No major differences in docking scores and poses of substrates and EPIs were observed between the wild type and corresponding AdeJ variants for any of the mutations considered. This study concludes that substrates and EPIs bound along the translocation path of AdeJ participate in its conformational transitions and can either increase or decrease the rate of transport and therefore the efficiency of EPIs.

Acinetobacter↗

An Analysis of the Novel Fluorocycline TP-6076 Bound to Both the Ribosome and Multidrug Efflux Pump AdeJ from Acinetobacter baumannii

Antibiotic resistance among bacterial pathogens continues to pose a serious global health threat. Multidrug-resistant (MDR) strains of the Gram-negative organism Acinetobacter baumannii utilize a number of resistance determinants to evade current antibiotics. One of the major resistance mechanisms employed by these pathogens is the use of multidrug efflux pumps. These pumps extrude xenobiotics directly out of bacterial cells, resulting in treatment failures when common antibiotics are administered. Here, the structure of the novel tetracycline antibiotic TP-6076, bound to both the Acinetobacter drug efflux pump AdeJ and the ribosome from Acinetobacter baumannii, using single-particle cryo-electron microscopy (cryo-EM), is elucidated. In this work, the structure of the AdeJ–TP-6076 complex is solved, and we show that AdeJ utilizes a network of hydrophobic interactions to recognize this fluorocycline. Concomitant with this, we elucidate three structures of TP-6076 bound to the A. baumannii ribosome and determine that its binding is stabilized largely by electrostatic interactions. We then compare the differences in binding modes between TP-6076 and the related tetracycline antibiotic eravacycline in both targets. These differences suggest that modifications to the tetracycline core may be able to alter AdeJ binding while maintaining interactions with the ribosome. Together, this work highlights how different mechanisms are used to stabilize the binding of tetracycline-based compounds to unique bacterial targets and provides guidance for the future clinical development of tetracycline antibiotics.

36 MATERIALS SCIENCE↗

Cold Climate Air Source Heat Pumps (ccASHPs) Technology

This report describes cold climate air source heat pump technology. Cold climate air source heat pumps (ccASHPs) are a variation of an existing air conditioning technology - heat pumps - that are designed to heat homes adequately in very cold weather (usually at or below 5 degrees F) and, as a secondary function, cool these homes during warm weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗