Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Autonomous Intelligence Measurements and Sensor Systems (AIMS): Gaussian Processes in Remote Sensing: Literature Review

Power grid resilience and reliability is crucial to supporting critical infrastructure. Service interruptions can have devastating consequences to communication, emergency, and transportation services, just to name a few. In addition to infrastructure, power services are crucial to everyday life. Nearly every element of modern-day living relies on a stable and functioning power grid - heating and cooling systems to lighting, refrigeration, telecommunications, and internet access. Interruptions in the power supply can range from minor inconveniences, such as the temporary loss of internet or television services, to more significant problems, like the inability to access medical equipment or emergency services during critical situations. As climate conditions worsen, the reliability of the power grid becomes even more significant. Extreme weather events, such as hurricanes, wildfires, or severe storms, can cause serious damage to power infrastructure, leading to prolonged power outages. Rising temperatures and changing weather patterns can strain the grid, resulting in increased demand for electricity, stressing transmission and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Cybersecurity of DER Systems: Cybersecurity Training for State Commissions

NARUC regularly hosts multi-day cybersecurity training events for commissioners and their staff to gain knowledge of IT/OT technologies, understand the spectrum of state and federal approaches to cybersecurity, and explore cybersecurity cost recovery challenges and innovative solutions to address them. About 300 commissioners and staffers typically register for these virtual events.

cybersecurity cost recovery↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Kinetic Monte Carlo Approach for Simulating Cascading Transmission Line Failure

In this work, cascading transmission line failures are studied through a dynamical model of the power system operating under fixed conditions. The power grid is modeled as a stochastic dynamical system where first-principles electromechanical dynamics are excited by small Gaussian disturbances in demand and generation around a specified operating point. In this context, a single line failure is interpreted in a large deviation context as a first escape event across a surface in phase space defined by line security constraints. The resulting system of stochastic differential equations admits a transverse decomposition of the drift, which leads to considerable simplification in evaluating the quasipotential (rate function) and, consequently, computation of exit rates. Tractable expressions for the rate of transmission line failure in a restricted network are derived from large deviation theory arguments and validated against numerical simulations. Extensions to realistic settings are considered, and individual line failure models are aggregated into a Markov model of cascading failure inspired by chemical kinetics. Cascades are generated by traversing a graph composed of weighted edges representing transitions to degraded network topologies. Numerical results indicate that the Markov model can produce cascades with qualitative power-law properties similar to those observed in empirical cascades.

Kinetic Monte Carlo, rare events, Cascading Failur↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Near Infrared Cavity Ring-Down Spectroscopy for Isotopic Analyses of CH4 on Future Martian Surface Missions

A compact Near Infrared Continuous Wave Cavity Ring-Down Spectrometer (near-IR-cw-CRDS) was developed as a candidate for future planetary surface missions. The optical cavity was made of titanium with rugged quartz windows to protect the delicate super cavity from the harsh environmental changes that it would experience during space flight and a Martian surface mission. This design assured the long-term stability of the system. The system applied three distributed feedback laser diodes (DFB-LD), two of which were tuned to the absorption line peaks of (sup 12)CH4 and (sup 13)CH4 at 6046.954 inverse centimeters and 6049.121 inverse centimeters, respectively. The third laser was tuned to a spectral-lines-free region for measuring the baseline cavity loss. The multiple laser design compensated for typical baseline drift of a CRDS system and, thus, improved the overall precision. A semiconductor optical amplifier (SOA) was used instead of an Acousto-Optic Module (AOM) to initiate the cavity ring-down events. It maintained high acquisition rates such as AOM, but consumed less power. High data acquisition rates combined with improved long-term stability yielded precise isotopic measurements in this near-IR region even though the strongest CH4 absorption line in this region is 140 times weaker than that of the strongest mid-IR absorption band. The current system has a detection limit of 1.4 times 10( sup –12) inverse centimeters for (sup 13)CH4. This limit corresponds to approximately 7 parts per trillion volume of CH4 at 100 Torrs. With no further improvements the detection limit of our current near IR-cw-CRDS at an ambient Martian pressure of approximately 6 Torrs (8 millibars) would be 0.25 parts per billion volume for one 3.3 minute long analysis.

portable nir crds↗

Human Mars Mission Transit Abort Options for Ballistic High Thrust and Hybrid Transportation Systems

Throughout the entire history of human spaceflight, astronauts have never been more than a few day's journey from Earth. For missions to the International Space Station, or even to the Moon, aborting the mission and returning home is a relatively straightforward operation in the event of a life-threatening contingency. But on the journey to Mars, a mission abort is complicated by a single factor: the sheer distance to Mars that will take time to cover regardless of how powerful the propulsion system is. In a significant departure from the entire human spaceflight experience to date, a Mars mission abort will not mean an immediate return to Earth due to the heliocentric nature of the transit. After escaping Earth’s gravity and entering heliocentric space, aborting a mission to Mars will be measured in months not days even if the abort is initiated relatively early in the mission. This represents a fundamental shift in the way mission aborts are utilized to reduce mission risks and this change must be part of the narrative when discussing reliability, crew risk, contingency planning, and mission operations. Abort capability will vary between transportation propulsion systems depending on final design, operational implementation, and actual mission parameters such as departure date, but the difference is relatively insignificant given that ``mission abort'' in the heliocentric frame of reference is a wildly different paradigm than that historically used for Earth-centric missions which rely on abort as a risk mitigation strategy. The primary objective of this paper is to provide a clearer definition of human Mars mission aborts from a celestial physics and orbital mechanics perspective in the context of different propulsion systems.

Mars Architecture Team↗

The Orbiting Carbon Observatory (OCO-2) Tracks 2-3 Peta-Gram Increase in Carbon Release to the Atmosphere During the 2014-2016 El Nino

The powerful El Niño event of 2015-2016 - the third most intense since the 1950s - has exerted a large impact on the Earth's natural climate system. The column-averaged CO2 dry-air mole fraction (XCO2) observations from satellites and ground based networks are analyzed together with in situ observations for the period of September 2014 to October 2016. From the differences between satellite (OCO-2) observations and simulations using an atmospheric chemistry-transport model, we estimate that, relative to the mean annual fluxes for 2014, the most recent El Niño has contributed to an excess CO2 emission from the Earth's surface (land+ocean) to the atmosphere in the range of 2.4+/-0.2 PgC (1 Pg = 10(exp 15) g) over the period of July 2015 to June 2016. The excess CO2 flux is resulted primarily from reduction in vegetation uptake due to drought, and to a lesser degree from increased biomass burning. It is about the half of the CO2 flux anomaly (range: 4.4-6.7 PgC) estimated for the 1997/1998 El Niño. The annual total sink is estimated to be 3.9+/-0.2 PgC for the assumed fossil fuel emission of 10.1 PgC. The major uncertainty in attribution arise from error in anthropogenic emission trends, satellite data and atmospheric transport.

OCO-2↗

Nuclear Safety [Vol. 33, No. 1, January-March 1992]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 Technical Note: A New Approach to Fission Reactor Safety, Yu. V. Petrov; 5 Erratum; ACCIDENT ANALYSIS: 6 Analysis and Modeling of Fission Product Release from Various Uranium-Aluminum Plate-Type Reactor Fuels, R. P. Taleyarkhan; CONTROL AND INSTRUMENTATION: 23 Applications of a Surveillance and Diagnostics Methodology Using Neutron Noise From a Pressurized-Water Reactor, R. T. Wood, L. F. Miller, and R. B. Perez; DESIGN FEATURES: 36 Westinghouse Advanced Passive 600 Plant, B. A. McIntyre and R. K. Beck; 47 System 80+™ PWR Safety Design, C. W. Bagnal, R. A. Matzie, and R. S. Turk; ENVIRONMENTAL EFFECTS: 58 The MATS Experiments—Mesoscale Atmospheric Transport Studies at the Savannah River Site, A. H. Weber, S. Berman, R. J. Kurzeja, and R. P. Addis; 75 Book Review: Environmental Radioactivity in the European Community 1984-1985-1986, C. A. Little; WASTE AND SPENT FUEL MANAGEMENT: 76 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 87 Aging Assessment of BWR Control Rod Drive Systems, R. H. Greene; 100 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 103 Selected Safety-Related Events, Compiled by G. A. Murphy; 110 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; RECENT DEVELOPMENTS: 129 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 139 Reports, Standards, and Safety Guides, D. S. Queener; 143 Proposed Rule Changes as of Sept. 30 1991; ANNOUNCEMENTS: 128 Harvard School of Public Health Announces Short Courses; 128 16th Biennial ANS Topical Meeting on Reactor Operating Experience: Present and Future Technologies—Applying Lessons Learned (Call for Papers); 147 The Authors; 150 Indexes to Nuclear Safety, Volume 32; 154 Errata.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Thrust Takeoff for the NASA X-57 Mod IV Flight Demonstrator

The Mod IV configuration of the X-57 flight demonstrator concept featured two forms of distributed electric propulsion—one cruise propulsor at each wingtip for primary propulsion that enabled favorable interaction with the wingtip vortex, and six high-lift propulsors distributed along the leading edge of each wing to enhance low-speed flight characteristics. The power system that fed these propulsors was arranged in two independent power buses. This unique arrangement did not lend itself to traditional “one engine inoperative” methods for determining performance after a critical failure in the propulsion system. Several potential failure scenarios were identified as potential “critical loss of thrust” events, and experiments that included pilot-in-the-loop simulation with the project test pilots were conducted to determine if these events would result in adequate handling and performance. Prior research showed that a total failure of one of the cruise motors during takeoff or initial climb could result in unacceptable performance for a traditional full-power takeoff. A new technique dubbed Distributed Thrust Takeoff (DiTTo) was developed to reduce the impact of the thrust asymmetry and total loss of thrust that could occur in any of the critical loss of thrust scenarios. The results showed that adequate performance and handling qualities could be achieved in each of the critical failure scenarios when using the DiTTo technique.

Distributed Propulsion, Electric Propulsion, Criti↗

Distributed Thrust Takeoff for the NASA X-57 Mod IV Flight Demonstrator

The Mod IV configuration of the X-57 flight demonstrator concept featured two forms of distributed electric propulsion—one cruise propulsor at each wingtip for primary propulsion that enabled favorable interaction with the wingtip vortex, and six high-lift propulsors distributed along the leading edge of each wing to enhance low-speed flight characteristics. The power system that fed these propulsors was arranged in two independent power buses. This unique arrangement did not lend itself to traditional “one engine inoperative” methods for determining performance after a critical failure in the propulsion system. Several potential failure scenarios were identified as potential “critical loss of thrust” events, and experiments that included pilot-in-the-loop simulation with the project test pilots were conducted to determine if these events would result in adequate handling and performance. Prior research showed that a total failure of one of the cruise motors during takeoff or initial climb could result in unacceptable performance for a traditional full-power takeoff. A new technique dubbed Distributed Thrust Takeoff (DiTTo) was developed to reduce the impact of the thrust asymmetry and total loss of thrust that could occur in any of the critical loss of thrust scenarios. The results showed that adequate performance and handling qualities could be achieved in each of the critical failure scenarios when using the DiTTo technique.

Distributed Propulsion↗

Search for bursts in air shower data

There have been reports in recent years of the possible observation of bursts in air shower data. If such events are truly of an astrophysical nature then, they represent an important new class of phemonenon since no other bursts have been observed above the MeV level. The spectra of conventional gamma ray bursts are unknown at higher energies but their observed spectra at MeV energies appear generally to exhibit a steepening in the higher MeV range and are thus unlikely to extrapolate to measurable fluxes at air shower energies. An attempt has been made to look for deviations from randomness in the arrival times of air showers above approx. 10 to the 14th power eV with a number of systems and results so far are presented here. This work will be continued for a substantial period of ime with a system capable of recording bursts with multiple events down to a spacing of 4 microns. Earlier data have also been searched for the possible association of air shower events with a glitch of the Vela pulsar.

Bruce, T. E. G.↗

Proactive Posturing of Large Power Grid for Mitigating Hurricane Impacts

In the past decade, natural disasters such as hurricanes have challenged the operation and control of U.S. power grid more. It is crucial to develop proactive strategies to assist grid operators for better emergency response and minimized electricity service interruptions. In this paper, we propose a proactive posturing methodology of power system elements, and formulated a Security-Constrained Optimal Power Flow (SCOPF) that informed by cross-domain hurricane modeling and its potential impacts on the grid elements. Simulation results based on real-world power grid and historical hurricane event validated the applicability of the proposed optimization formulation, and show potential to enable grid operators and planners with interactive cross-domain data analytics in mitigating hurricane impacts.

power system emergency response, security constrai↗

FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter

This technology enables detection and measurement of x-rays in an x-ray polarimeter using a field-programmable gate array (FPGA). The technology was developed for the Gravitational and Extreme Magnetism Small Explorer (GEMS) mission. It performs precision energy and timing measurements, as well as rejection of non-x-ray events. It enables the GEMS polarimeter to detect precisely when an event has taken place so that additional measurements can be made. The technology also enables this function to be performed in an FPGA using limited resources so that mass and power can be minimized while reliability for a space application is maximized and precise real-time operation is achieved. This design requires a low-noise, charge-sensitive preamplifier; a highspeed analog to digital converter (ADC); and an x-ray detector with a cathode terminal. It functions by computing a sum of differences for time-samples whose difference exceeds a programmable threshold. A state machine advances through states as a programmable number of consecutive samples exceeds or fails to exceed this threshold. The pulse height is recorded as the accumulated sum. The track length is also measured based on the time from the start to the end of accumulation. For track lengths longer than a certain length, the algorithm estimates the barycenter of charge deposit by comparing the accumulator value at the midpoint to the final accumulator value. The design also employs a number of techniques for rejecting background events. This innovation enables the function to be performed in space where it can operate autonomously with a rapid response time. This implementation combines advantages of computing system-based approaches with those of pure analog approaches. The result is an implementation that is highly reliable, performs in real-time, rejects background events, and consumes minimal power.

Gregory, Kyle↗

Nuclear Safety [Vol. 34, No. 1, January-March 1993]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 An Integrated Regional Approach To Risk Management of Industrial Systems, S. Chakraborty and R. Stratton; 9 Annual Technical Meeting of the NRC Cooperative Severe Accident Research Program, E. G. Silver; ACCIDENT ANALYSIS: 13 Deterministic Severe Accident Criteria as Severe Accident Design Criteria and Policy for the New Production Reactor-Heavy Water Reactor, P. T. Rhoads; 20 Proposed Deterministic Severe Accident Criteria for the Heavy Water Reactor-New Production Reactor Containment, K. D. Bergeron, S. E. Slezak, and C. E. Leach; 33 Quasi-Static Core Liquid Level Depression and Long-Term Core Uncovery During a PWR LOCA, Y. Kukita, R. R. Schultz, H. Nakamura, and J. Katayama; 49 LIRA: An Advanced Containment System to Minimize the Accidental Radioactivity Releases, A. Turricchia; 63 Errata to “A Review of Hydrogen Production During Melt/Water Interaction in LWRs,” Vol. 33, No. 4; CONTROL AND INSTRUMENTATION: 64 The Nuplex 80+™ Advanced Control Complex from ABB Combustion Engineering, F. Ridolfo, D. Harmon, and K. Scarola; DESIGN FEATURES: 76 A Scheme for Passive Isolation of the Containment of a Reactor, A. K. Ghosh, V. V. Raj, and K. Kakodkar; 84 Utility Requirements for Safety in the Passive Advanced Light-Water Reactor, T. U. Marston, W. H. Layman, and G. Bockhold, Jr.; WASTE AND SPENT FUEL MANAGEMENT: 91 Activities Related to Waste and Spent Fuel Management, Compiled by M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 103 Testing Deficiencies in Auxiliary Systems Feedwater Systems, J. D. Kueck; 110 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 113 Selected Safety-Related Events, Compiled by G. A. Murphy; 115 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; RECENT DEVELOPMENTS: 133 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 145 Reports, Standards, and Safety Guides, D. S. Queener; 150 Proposed Rule Changes as of Sept. 30, 1992; ANNOUNCEMENTS: 75 Harvard Short Course on Risk: Science, Assessment, and Management; 102 International Conference on Reactor Physics and Reactor Computations; 102 The Fourth International Conference on Nuclear Waste Reprocessing and Waste Management [RECOD ’94]; 132 International Symposium on the Radiological Exposure of the Population of the European Community from Radioactivity in the Mediterranean Sea [MARINA-MED]; 162 International High-Level Radioactive Waste Conference ‘Technology Integration—Above and Below”; 154 The Authors; 158 Indexes to Nuclear Safety, Volume 33.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗