Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Active virus-host interactions at sub-freezing temperatures in Arctic peat soil

Abstract Background Winter carbon loss in northern ecosystems is estimated to be greater than the average growing season carbon uptake and is primarily driven by microbial decomposers. Viruses modulate microbial carbon cycling via induced mortality and metabolic controls, but it is unknown whether viruses are active under winter conditions (anoxic and sub-freezing temperatures). Results We used stable isotope probing (SIP) targeted metagenomics to reveal the genomic potential of active soil microbial populations under simulated winter conditions, with an emphasis on viruses and virus-host dynamics. Arctic peat soils from the Bonanza Creek Long-Term Ecological Research site in Alaska were incubated under sub-freezing anoxic conditions with H 2 18 O or natural abundance water for 184 and 370 days. We sequenced 23 SIP-metagenomes and measured carbon dioxide (CO 2 ) efflux throughout the experiment. We identified 46 bacterial populations (spanning 9 phyla) and 243 viral populations that actively took up 18 O in soil and respired CO 2 throughout the incubation. Active bacterial populations represented only a small portion of the detected microbial community and were capable of fermentation and organic matter degradation. In contrast, active viral populations represented a large portion of the detected viral community and one third were linked to active bacterial populations. We identified 86 auxiliary metabolic genes and other environmentally relevant genes. The majority of these genes were carried by active viral populations and had diverse functions such as carbon utilization and scavenging that could provide their host with a fitness advantage for utilizing much-needed carbon sources or acquiring essential nutrients. Conclusions Overall, there was a stark difference in the identity and function of the active bacterial and viral community compared to the unlabeled community that would have been overlooked with a non-targeted standard metagenomic analysis. Our results illustrate that substantial active virus-host interactions occur in sub-freezing anoxic conditions and highlight viruses as a major community-structuring agent that likely modulates carbon loss in peat soils during winter, which may be pivotal for understanding the future fate of arctic soils' vast carbon stocks.

59 BASIC BIOLOGICAL SCIENCES↗

Management of Risks Associated with Application of Novel Materials in Novel Operating Environments in Novel Reactor Designs

There is currently no widely agreed, detailed general method for licensing a novel plant incorporating novel materials (or materials being deployed in novel environments); in many such situations, there are no directly applicable engineering code cases for decision-makers (including regulators) to rely on. This paper discusses a framework for solving this problem that is based on the Reliability and Integrity Management (RIM) approach delineated in ASME BPVC Section XI Division 2. NRC Regulatory Guide 1.246, Rev. 0, endorses, with conditions, the subject portion of the ASME Code. The proposed framework is meant to support development of a licensing case by addressing certain technical challenges. The framework discussed here is compatible with the Licensing Modernization Project, but applying it in a specific case will call for advances in the state of practice, if not the state of the art. The RIM approach calls for applicants to (a) allocate reliability targets to plant structures, systems, and components (SSCs), (b) show that they are able to relate the currently observed physical condition of each SSC in the program to its failure probability well enough to determine whether the target reliability allocations are being satisfied, allowing for uncertainty related to the novelty of the materials/designs/operating environments, and (c) be able to demonstrate that the proposed program of surveillances will reliably detect unacceptable degradation of an SSC before SSC failure occurs. These challenges are discussed in the paper, and a potentially applicable modeling approach based on cumulative damage rather than failure rates is briefly illustrated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 California Household Travel Survey Supplement

# 2012 California Household Travel Survey Supplement The 2012 California Household Travel Survey Supplement focused on gathering specific travel information from residents for the development of next-generation, activity-based models. Called the "Augment Survey," it supplemented the [2010–2012 California Household Travel Survey](https://www.nrel.gov/transportation/secure-transportation-data/tsdc-california-travel-survey). ## Data Collection Agency The Southern California Association of Governments (SCAG) hired Abt-SRBI, Inc. to conduct the survey. ## Methodology Travel data were collected from households via in-vehicle (625 vehicles) and wearable (244 participants) global positioning system (GPS) devices. ## Drive Cycle Processing and Filtering NREL has developed a GPS data filtration routine to filter erroneous data points in individual drive cycles sourced from GPS devices mounted in vehicles. Second-by-second drive cycle data collected from GPS-instrumented vehicles during this survey have passed through NREL's drive cycle processing and filtering routines. ## Survey Records Study records include 473 households. ## Transportation Data The SCAG data set contains data from 473 households that participated in one or more areas of study. Of these, 141 completed the wearable GPS portion of the study and 332 completed the vehicle GPS portion. There was no overlap between households participating in the two study areas (wearable and vehicle GPS). For details on available travel survey data and variable definitions, see the [data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/caltrans_scag_data_dictionary.pdf?sfvrsn=6ec36d7a_1). NREL-generated drive cycle data are also available for this survey. For details on available data and variable definitions, see the [drive cycle data dictionary](https://www.nrel.gov/media/docs/libraries/tsdc/drive_cycles_data_dictionary.pdf?sfvrsn=7de7e888_1). Transportation data are available as zipped files. [Download Winzip](http://www.winzip.com/downwz.htm).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially Dependent Seismic Wavefield Scattering from an Underground Chemical Explosion: Analysis of the Source Physics Experiment Dry Alluvium Geology Large- N Array

Explosion sources have been observed to generate significant shear‐wave energy despite their isotropic nature. To investigate this phenomenon, we conduct an analysis of the seismic data collected as part of the Source Physics Experiment (SPE): Dry Alluvium Geology (DAG) and investigate the generation of shear‐wave energy via scattering. The data were produced by three underground chemical explosions and consist of three‐component seismograms, which were recorded by the DAG Large‐N array. Synthetic tests suggest that for the DAG experiments, small‐scale stochastic heterogeneities, defined as features with correlation lengths of 10–100s of meters, are more effective than large‐scale geologic structure (scales >1–10 km) at reproducing the scattering of explosion generated wavefields observed at DAG. We analyze the seismic data for spatially variable ratios between transversely and radially polarized seismic energy, and then estimate the mean free path of P and S waves. All analyses are conducted within a frequency band of 5–50 Hz. The ratio of transversely to radially polarized energy is the highest in the east and west portion of the Large‐N array. In addition, the magnitude of the estimated S‐wave mean free path is shorter in the eastern portion of the Large‐N array. This variation indicates that the eastern area of the DAG array is where more scattering is occurring, suggesting azimuthal dependence of P‐to‐P and P‐to‐S scattering. Furthermore, this azimuthal dependence of P‐to‐S scattering can have implications for explosion discrimination based on spectral ratios of seismic wave types, because the general assumption is that explosions do not generate shear‐wave energy. Synthetic tests modeling only larger‐scale geologic structure had lower transversely polarized energy (only four stations showing a transversely to radially polarized energy ratio greater than 1) and fewer stations (<10) displaying shorter (<300 m) mean free paths than what was observed in the DAG data results.

Darrh, Andréa Nicole↗

Wasatch Fault Structure from Machine Learning Arrival Times and High-Precision Earthquake Locations

Abstract On 18 March 2020, a magnitude 5.7 earthquake hit the Salt Lake valley in the state of Utah, United States. Using a dense geophone deployment and machine learning (ML), an additional several thousand events were detected and located. Currently, both the mainshock and the majority of the aftershocks are suspected to have occurred on or near a deeper portion of the Salt Lake segment of the Wasatch fault—part of a large range-bounding fault system thought to be capable of generating an Mw 7.2 earthquake. However, a small subset of aftershocks may have occurred on a portion of the more steeply, eastward dipping, and poorly understood West Valley fault. Unfortunately, the catalog locations and lack of focal mechanisms for this subset of aftershocks provide only a crude constraint on the true fault structure. To better illuminate fault structure, we relocate the ML-generated catalog with a range of magnitudes from −2 to 4.6, using: (1) NonLinLoc, a nonlinear location algorithm, (2) source-specific station terms, and (3) waveform coherence. We further compute first-motion focal mechanisms for 68 events. Results of the relocation suggest a simpler, minimally listric Wasatch fault geometry, contrary to what has been previously proposed. We also find that analysis of the focal mechanisms and waveform similarity indicates minimal event similarity throughout the Magna sequence, suggesting a highly complex and heterogeneous rupture zone, as opposed to rupture on a single plane. These findings suggest an increased seismic hazard due to the overall shallowness of the earthquake sequence and highly varied rupture mechanisms.

Geochemistry & Geophysics↗

Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO2 Storage

The project Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO2 Storage is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The South Carolina Research Foundation and partners evaluated the feasibility of CCS in the Jurassic/ Triassic (J / TR) saline formations of the buried Mesozoic South Georgia Rift (SGR) Basin that extends from South Carolina into Georgia. The J / TR sequence, based on preliminary assessment of limited geologic and geophysical data, appears to have both the appropriate areal extent and multiple horizons to permanently and safely store CO2 The presence of several igneous rock layers within the sequence may potentially provide adequate seals to prevent upward CO2 migration into the Coastal Plain aquifer systems. Approximately 81 kilometers of 2-D seismic reflection data were collected by Bay Geophysical, Inc. to explore a portion of the SGR located in southern Georgia. The 81 kilometers were divided into two lines approximately 40.5 kilometers each, with Line 1 intersecting Georgia well GGS 3457. Line 2 intersects Line 1 at the southern portion of Line 1 to maximize the extent of coverage away from GGS-3457 (a deep well drilled in the 1980s for oil and gas exploration). This well had a set of usable logs, including gamma and neutron logs that provided promising results related to CO2 storage. Results showed sandstone with porosity values greater than 10 percent and a thickness of 120 meters. The design of the seismic shot was to extrapolate information away from the well and to better define the extent of the SGR and the necessary reservoir and caprock for a successful CO2 injection. A numerical simulation model of CO2 Injection and migration was developed based on the geology log for the GGS-3457 well. The simulation model was used to investigate the feasibility of injecting 30 million metric tons of CO2 into SGR J / TA sediments and integrity of the diabase layers as seals to prevent CO2 migration.

2-D seismic↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗