Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Role of a microbore capillary column in the development of a portable gas chromatograph-mass spectrometer

An approach to the development of a high-performance, field portable gas chromatograph-mass spectrometer is presented which is based on a combination of a short microbore capillary column and a miniaturized, light-weight focal plane mass spectrograph. Performance results of the short microbore column for the mixture separation of the major pollutants and data on time-resolved mass spectral measurements of overlapped gas chromatograph peaks are reported.

Sinha, Mahadeva P.↗

A Portable Calibrator for Dynamic Strain Gages

A portable device for calibrating dynamic strain gages is described. The device contains a motor-driven cam, which applies alternating tensile loads to a metal strip 5/8 inch wide and 6 1/4 inches long. The cam is designed to produce a nearly sinusoidal variation of strain with time. Dynamic strain gages with gage lengths up to 5 inches may be calibrated by mounting them on the strip and by changing the frequency and the amplitude of the tensile load. The frequency may be varied from 15 to 30 cycles per second and the strain amplitude from 0 to 10x10-4 in steps of 2x10-4.

Mcpherson, Albert E↗

Portable Presentation And Instruction Unit

Proposed electronic display unit reminiscent of kiosk serves as portable, interactive, multimedia information terminal. Used as traveling science exhibit, aid for teaching science in schools, or training and skill-refresher device for space flight crews. Provides interactive video and audio displays, including three-dimensional-appearing video simulations. Speeds learning and improves retention by applying principles of scientific visualization. Also helps previously trained but recently unpracticed personnel relearn special skills and procedures quickly.

Christman, L.↗

TROJID: A portable software package for upper-stage trajectory optimization

Performance optimization for upper-stage exoatmospheric vehicles often is performed within the framework of a full capability trajectory simulation package requiring either a large mainframe computer or powerful work-station. Since these software packages tend to include capabilities providing for high-fidelity boost and reentry simulations, the programs usually are quite large and not very portable. The program TROJID is an attempt to provide an environment for the optimization of upper-stage trajectories within a small package capable of being run on a standard desktop microcomputer. Utilizing a state-of-the-art nonlinear programming algorithm and a trajectory simulator implementing impulsive burns and an analytic coast phase propagator, TROJID is capable of producing trajectories for optimal multi-burn upper-stage orbit transfers. The package has been designed to allow full generality in definition of both the trajectory simulator and the parameter optimization problem.

Hammes, Steven M.↗

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Development of a portable multispectral thermal infrared camera

The purpose of this research and development effort was to design and build a prototype instrument designated the 'Thermal Infrared Multispectral Camera' (TIRC). The Phase 2 effort was a continuation of the Phase 1 feasibility study and preliminary design for such an instrument. The completed instrument designated AA465 has application in the field of geologic remote sensing and exploration. The AA465 Thermal Infrared Camera (TIRC) System is a field-portable multispectral thermal infrared camera operating over the 8.0 - 13.0 micron wavelength range. Its primary function is to acquire two-dimensional thermal infrared images of user-selected scenes. Thermal infrared energy emitted by the scene is collected, dispersed into ten 0.5 micron wide channels, and then measured and recorded by the AA465 System. This multispectral information is presented in real time on a color display to be used by the operator to identify spectral and spatial variations in the scenes emissivity and/or irradiance. This fundamental instrument capability has a wide variety of commercial and research applications. While ideally suited for two-man operation in the field, the AA465 System can be transported and operated effectively by a single user. Functionally, the instrument operates as if it were a single exposure camera. System measurement sensitivity requirements dictate relatively long (several minutes) instrument exposure times. As such, the instrument is not suited for recording time-variant information. The AA465 was fabricated, assembled, tested, and documented during this Phase 2 work period. The detailed design and fabrication of the instrument was performed during the period of June 1989 to July 1990. The software development effort and instrument integration/test extended from July 1990 to February 1991. Software development included an operator interface/menu structure, instrument internal control functions, DSP image processing code, and a display algorithm coding program. The instrument was delivered to NASA in March 1991. Potential commercial and research uses for this instrument are in its primary application as a field geologists exploration tool. Other applications have been suggested but not investigated in depth. These are measurements of process control in commercial materials processing and quality control functions which require information on surface heterogeneity.

Osterwisch, Frederick G.↗

Open environments to support systems engineering tool integration: A study using the Portable Common Tool Environment (PCTE)

A study of computer engineering tool integration using the Portable Common Tool Environment (PCTE) Public Interface Standard is presented. Over a 10-week time frame, three existing software products were encapsulated to work in the Emeraude environment, an implementation of the PCTE version 1.5 standard. The software products used were a computer-aided software engineering (CASE) design tool, a software reuse tool, and a computer architecture design and analysis tool. The tool set was then demonstrated to work in a coordinated design process in the Emeraude environment. The project and the features of PCTE used are described, experience with the use of Emeraude environment over the project time frame is summarized, and several related areas for future research are summarized.

Eckhardt, Dave E., Jr.↗

Preliminary results from the portable standard satellite laser ranging intercomparison with MOBLAS-7

Conventional Satellite Laser Ranging (SLR) instrumentation has been configured and successfully used to provide high-accuracy laboratory measurements on the LAGEOS-2 and TOPEX cube-corner arrays. The instrumentation, referred to as the Portable Standard, has also been used for field measurements of satellite ranges in tandem with MOBLAS-7. Preliminary results of the SLR measurements suggest that improved range accuracy can be achieved using this system. Results are discussed.

Selden, Michael↗

Portable Habitat for Antarctic Scientific Research (PHASR)

The Portable Habitat for Antarctic Scientific Research, PHASR, is designed as a versatile, general purpose habitat system that addresses the problem of functional space and environmental soundness in a partially fabric-covered shelter. PHASR is used for remote field site applications that can be quickly deployed. PHASR will also provide four scientists with a comfortable and efficient use of interior space. PHASR is a NASA/USRA Advanced Design Program project conducted at the University of Houston College of Architecture, Sasadawa International Center for Space Architecture (SICSA). This report is prepared for NASA/USRA.

Griswold, Samantha S.↗

Portable Linear Sled (PLS) for biomedical research

The PLS is a portable linear motion generating device conceived by researchers at Ames Research Center's Vestibular Research Facility and designed by engineers at Ames for the study of motion sickness in space. It is an extremely smooth apparatus, powered by linear motors and suspended on air bearings which ride on precision ground ceramic ways.

Vallotton, Will↗

Portable color multimedia training systems based on monochrome laptop computers (CBT-in-a-briefcase), with spinoff implications for video uplink and downlink in spaceflight operations

This report describes efforts to use digital motion video compression technology to develop a highly portable device that would convert 1990-91 era IBM-compatible and/or MacIntosh notebook computers into full-color, motion-video capable multimedia training systems. An architecture was conceived that would permit direct conversion of existing laser-disk-based multimedia courses with little or no reauthoring. The project did not physically demonstrate certain critical video keying techniques, but their implementation should be feasible. This investigation of digital motion video has spawned two significant spaceflight projects at MSFC: one to downlink multiple high-quality video signals from Spacelab, and the other to uplink videoconference-quality video in realtime and high quality video off-line, plus investigate interactive, multimedia-based techniques for enhancing onboard science operations. Other airborne or spaceborne spinoffs are possible.

Scott, D. W.↗

M.E.366-J embodiment design project: Portable foot restraint

During space shuttle operations, astronauts require support to carry out tasks in the weightless environment. In the past, portable foot restraints (PFR) with orientations adjustable in pitch, roll, and yaw provided this support for payload bay operations. These foot restraints, however, were designed for specific tasks with a load limit of 111.2 Newtons. Since the original design, new applications for foot restraints have been identified. New designs for the foot restraints have been created to boost the operational work load to 444.8 Newtons and decrease setup times. What remains to be designed is an interface between the restraint system and the extravehicular mobility unit (EMU) boots. NASA provided a proposed locking device involving a spring-loaded mechanism. This locking mechanism must withstand loads of 1334.4 Newtons in any direction and weigh less than 222.4 Newtons. This paper develops an embodiment design for the interface between the PFR and the EMU boots. This involves design of the locking mechanism and a removable cleat that allows the boot to interface with this mechanism. The design team used the Paul Beitz engineering methodology to present the systematic development, structural analysis, and production considerations of the embodiment design. This methodology provides a basis for understanding the justification behind the decisions made in the design.

Heaton, Randall↗

The embodiment design of the heat rejection system for the portable life support system

The Portable Life Support System (PLSS) provides a suitable environment for the astronaut in the Extravehicular Mobility Unit (EMU), and the heat rejection system controls the thermal conditions in the space suit. The current PLSS sublimates water to the space environment; therefore, the system loses mass. Since additional supplies of fluid must be available on the Space Shuttle, NASA desires a closed heat rejecting system. This document presents the embodiment design for a radiative plate heat rejection system without mass transfer to the space environment. This project will transform the concept variant into a design complete with material selection, dimensions of the system, layouts of the heat rejection system, suggestions for manufacturing, and financial viability.

Stuckwisch, Sue↗

Hand-portable gas chromatography-ion mobility spectrometer for the determination of the freshness of fish

A hand-held, portable gas chromatography-ion mobility spectrometer (GC-IMS) device was used to detect the presence of volatile amine compounds in the headspace of decomposing fish. The Food and Drug Administration (FDA) largely relies on olfactory discrimination with respect to fresh and spoiled, frozen and unfrozen fish. The fish are delivered at ship docks on pallets, and each pallet of fish can range from 30-40 thousand dollars in value. Fresh fish were placed in a teflon bag and the direct headspace was interrogated. In the first three days, only low molecular weight volatile amines were detected. On the fourth day, a number of spectral signatures were observed which indicated the presence of 1,5-diaminopentane, cadaverine. Analyses typically took from 0.5-1 minute.

Snyder, A. Peter↗

Improved Portable Ultrasonic Leak Detectors

Improved portable ultrasonic leak detector features three interchangeable ultrasonic-transducer modules, each suited for operation in unique noncontact or contact mode. One module equipped with ultrasound-collecting horn for use in scanning to detect leaks from distance; horn provides directional sensitivity pattern with sensitivity multiplied by factor of about 6 in forward direction. Another module similar, does not include horn; this module used for scanning close to suspected leak, where proximity of leak more than offsets loss of sensitivity occasioned by lack of horn. Third module designed to be pressed against leaking vessel; includes rugged stainless-steel shell. Improved detectors perform significantly better, smaller, more rugged, and greater sensitivity.

Youngquist, Robert C.↗