Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plant operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

Assessment of small mechanical wastewater treatment plants: Relative life cycle environmental impacts of construction and operations

Many slow growing and shrinking rural communities struggle with aging or inadequate wastewater treatment plants (WWTPs), and face challenges in constructing and operating such facilities. Although existing literature has provided insight into the environmental sustainability of large facilities, including both the construction and operational phases, these studies have not examined small, rural facilities treating less than 7,000 m 3 /d (1.8 MGD) of wastewater in adequate depth and breadth. In this study, a detailed inventory of the construction and operational data for 16 case studies of small WWTPs was developed to elucidate their environmental life cycle impacts. Conventional LCA framework was followed. The results show that the environmental impacts of both the construction and operational phases are considerable. Operational impacts are highly related to energy usage. Improving energy efficiency of a plant may reduce the environmental impacts related to operations. Construction impacts can vary considerably between facilities. Process-related factors (e.g., concrete and reinforcing steel used in basins) are typically sized using the design flow; thus much of the variability in construction impacts among plants stems from the non-process related infrastructure. Multiple regression analysis was used as an exploratory tool to identify which non-process related plant aspects contribute to the variable environmental impact of small WWTPs. These factors include aluminum, cast iron, and the capacity utilization ratio (defined as the ratio of average flow to design flow). Furthermore, industry practitioners should consider these factors when aiming to reduce the environmental impacts of a small WWTP related to construction. Scenario sensitivity analyses found that the environmental impact of construction became smaller with longer design life, and the end-of-life consideration does not heavily influence the environmental sustainability of a WWTP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Cyber Security Testing Platform for Industrial Control Systems

Nuclear Power Plants (NPPs) are a complex system of coupled physics controlled by a network of Programmable Logic Controllers (PLCs). These PLCs communicate process data across the network to coordinate control actions with each other and inform the operators of process variables and control decisions. Networking the PLCs allows more effective process control and provides the operator more information which results in more efficient plant operation. This interconnectivity creates new security issues, as operators have more access to the plant controls, so will bad actors. As plant networks become more digitized and encompass more sophisticated controllers, the network surface exposed to cyber interference grows. Understanding the dynamics of these coupled systems of physics, control logic, and network communications is critical to their protection. The research into the cybersecurity of the Operational Technologies of NPPs is developing and requires a platform that can allow high fidelity physics simulations to interact with digital networks of controllers. This will require three main components: a network simulation environment, a physics simulator, and virtual PLCs (vPLC) that represent typical industry hardware. A platform that incorporates these three components to provide the most accurate representation of actual NPP networks and controllers is developed in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Abstract for CRADA among the National Energy Technology Laboratory, National Technology & Engineering Solutions of Sandia, The Regents of the University of California, and Tri-State Generation and Transmission Association, Inc. (AGMT-0855)

The objective of this CRADA is to facilitate cooperation among Tri-State Generation and Transmission Association, Inc. and collaborators of the Institute for the Design of Advanced Energy Systems (IDAES), including the National Energy Technology Laboratory, Sandia National Laboratories, and Lawrence Berkeley National Laboratory. The goal is to develop steady-state and dynamic optimization models of power plants. Tri-State will provide data related to the design and operation of power plants, which will be used to validate the IDAES team’s models and tools. These models will provide insight into potential improvements which could improve heat rate, reduce operations and maintenance costs, and/or improve reliability of the existing fleet of coal plants in the United States.

20 FOSSIL-FUELED POWER PLANTS↗

Demonstration and Evaluation of the Human-Technology Integration Function Allocation Methodology

There is an imminent need for the existing nuclear power plants to reduce their operating and maintenance (O&M) costs to remain economically viable. Digital technology, including automation, provides a significant opportunity for the existing nuclear power plant fleet to transform the way in which work is accomplished, reducing O&M costs, and allowing the fleet to remain economically competitive. One notable opportunity to significantly reduce O&M costs pertains to modifications to the plant equipment and main control room (MCR). Existing instrumentation and control (I&C) technologies in the MCR are highly analog, costly to operate and maintain, and demand a high cognitive and physical workload from plant staff (i.e., operators). Digitalizing the MCR has a range of broad economic benefits, including improved plant performance and reduced manual work. Further, digital I&C systems can fundamentally change the way in which plant staff operate the plant; this is the concept of operation. Human-technology integration is important to ensure that impacts to the concept of operation are done in a way that account for capabilities of people and technology. Human-technology integration employs human factors engineering (HFE) methods and principles to maximize the benefits of digital technology, reducing human error, improving overall decision-making and usability. The U.S. Department of Energy Light Water Reactor Sustainability Program is applying human-technology integration research to ensure digital technologies are safe, reliable, and efficient. This paper documents the demonstration of the human-technology guidance developed by the Light Water Reactor Sustainability Program from a first-of-a-kind digital I&C upgrade, specifically addressing function analysis and allocation for a new digital I&C system that included changes in automation levels. The program’s specific approach is included in this work, following lessons learned. This document serves as a resource for industry to follow in applying human-technology integration and HFE to digital modifications, specific to function analysis and allocation. The lessons learned should be considered in the planning and execution of HFE activities that support such digital modifications.

99 GENERAL AND MISCELLANEOUS↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

WTEC panel report on European nuclear instrumentation and controls

Control and instrumentation systems might be called the 'brain' and 'senses' of a nuclear power plant. As such they become the key elements in the integrated operation of these plants. Recent developments in digital equipment have allowed a dramatic change in the design of these instrument and control (I&C) systems. New designs are evolving with cathode ray tube (CRT)-based control rooms, more automation, and better logical information for the human operators. As these new advanced systems are developed, various decisions must be made about the degree of automation and the human-to-machine interface. Different stages of the development of control automation and of advanced digital systems can be found in various countries. The purpose of this technology assessment is to make a comparative evaluation of the control and instrumentation systems that are being used for commercial nuclear power plants in Europe and the United States. This study is limited to pressurized water reactors (PWR's). Part of the evaluation includes comparisons with a previous similar study assessing Japanese technology.

White, James D.↗

Multi-Timescale Optimal Operation Framework for Integrated Economic and Reliability Analysis of Hybrid Power Plants

This paper introduces a hierarchical modeling framework for hybrid power plants (HPP) to facilitate the operation of HPP in power systems similar to conventional generators (Congens) in the integrated multi-timescale optimal operation framework. To consider the uncertainties of HPP renewable power in the day-ahead scheduling, distributionally robust optimization (DRO) is used. To ensure that the state-of-charge (SOC) of energy storage systems in HPPs aligns closely with the planned value for long-term reliability, real-time SOC management is incorporated. In addition, an adjustable real-time control is designed for the robust delivery of HPP real-time services. Case studies performed on a revised IEEE 39-bus system demonstrate the effectiveness of the proposed framework for HPP operation. Simulation results highlight that the proposed framework not only can help operators schedule HPP similar to Congens in varying weather conditions but can also maintain the frequency reliability of the system.

frequency stability↗

Introduction to Nuclear Propulsion: Lecture 15 - Nuclear Test Operations

The test operation of nuclear power plants, specifically nuclear rockets, bears some interesting similarities to the operation of chemical rocket tests as well as, of course, many differences. A significant feature common to both nuclear and chemical rocket tests is that all the fuel for the entire operation is loaded at the start of the test. As a direct consequence of this fact, the operation of nuclear power plants must be surrounded with adequate safety precautions, as is indeed the case in the operation of chemical rockets, A second direct consequence is that in both types of testing a very thorough and complete checkout is made before starting the test.

TEST METHOD↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

Plant Growth Study: Growth of Three Plant Species in 100-OL-1 Operable Unit Soils

Soil contamination from historical application of lead arsenate pesticides persists in the 100-OL-1 Operable Unit (OU) of the U.S. Department of Energy’s Hanford Site in Benton County, Washington. A remedial investigation used a portable X-ray fluorescence analyzer to estimate and map the concentrations of metals in surface soil in the 133 decision units comprising the OU. There is variability in lead and arsenic concentrations among the non-contiguous decision units, and an incomplete understanding of the ecological and human risks from soil contamination. While general screening criteria for lead are reported in literature, limited information is available on the impacts of heavy metals on site-specific plant and animal life. To address this information gap, a study on plant growth in Hanford soils was conducted using native bluegrass (Poa secunda), invasive cheatgrass (Bromus tectorum), and buttercrunch lettuce (Lactuca sativa). The latter is included because it is a common species used in plant growth studies. Soil samples were collected from a single general location within the 100-OL-1 OU, prepared, and categorized as having low, medium, or high concentrations of lead and arsenic, with the high concentration soil having concentrations of up to 3,400 and 790 mg/kg lead and arsenic, respectively. Additionally, a synthetic soil was prepared and used as a control, in accordance with standard plant growth protocols. Fifty-four seeds of each plant species were planted in each of the four soil types following the procedure outlined by the Washington State Department of Ecology. Germination rates and biomass measurements were recorded for 20 days. Both bluegrass and lettuce germination rates appeared to be reduced at the highest lead and arsenic concentrations (Pb: 3400 mg/kg, As: 790 mg/kg), while cheatgrass germination rates were unaffected. Total biomass for all species appeared to be related to the relative concentrations of lead and arsenic in the soil. Results of this growth study agree reasonably well with previous Hanford Site plant growth studies and provide additional data for assessing ecological risk at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Challenges and Gaps in Integration of Advanced Sensors, Instrumentation, and Communication Technologies with Digital Twins for Nuclear Application

This paper explores integrating advanced sensor, instrumentation, and communication technologies with digital twin technologies for nuclear energy application. Digital twins and digital-twin-enabling technologies are expected to integrate with future nuclear reactor designs and have the potential to impact currently operating nuclear power plants. Greater digital integration, advanced instrumentation and control systems, and advanced operations and maintenance practices are all associated with digital-twin-enabling technologies. Advanced sensors, instrumentation, and communication technology are expected to comprise important elements of the infrastructure required to develop and operate a nuclear digital twin system. This paper identifies and discusses challenges and gaps in developing and implementing advanced sensors and instrumentation and communication technology to be integrated with a digital twin in current and advanced reactor applications. It is important to address some challenge and gap to enable a successful near-term deploying advanced sensors, instrumentation, and communication technologies integrated with digital twins.

Yadav, Vaibhav↗

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗