Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Fast optimization and dose calculation in scanned ion beam therapy

Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min.

60 APPLIED LIFE SCIENCES↗

SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inspection error and its adverse effects - A model with implications for practitioners

Inspection error has clearly been shown to have adverse effects upon the results desired from a quality assurance sampling plan. These effects upon performance measures have been well documented from a statistical point of view. However, little work has been presented to convince the QC manager of the unfavorable cost consequences resulting from inspection error. This paper develops a very general, yet easily used, mathematical cost model. The basic format of the well-known Guthrie-Johns model is used. However, it is modified as required to assess the effects of attributes sampling errors of the first and second kind. The economic results, under different yet realistic conditions, will no doubt be of interest to QC practitioners who face similar problems daily. Sampling inspection plans are optimized to minimize economic losses due to inspection error. Unfortunately, any error at all results in some economic loss which cannot be compensated for by sampling plan design; however, improvements over plans which neglect the presence of inspection error are possible. Implications for human performance betterment programs are apparent, as are trade-offs between sampling plan modification and inspection and training improvements economics.

Collins, R. D., Jr.↗

Autonomy Verification & Validation Roadmap and Vision 2045

Advanced capabilities planned for the next generation of autonomous and increasingly autonomous air vehicles will include non-traditional components based on artificial intelligence, machine learning, and complex optimization and planning algorithms. These complex components will be used to provide enhanced safety and high-level decision-making functions. However, there are serious barriers to the deployment of autonomous aircraft in the National Airspace System (NAS). Current civil aviation certification processes are based on the concept that the correct behavior of a system or a component must be completely specified and verified prior to operation. This report from the Autonomy Verification and Validation (V&V) Roadmap and Vision 2045 project presents the most recent effort to build a comprehensive list of verification challenges and needs for autonomous aircraft, a roadmap to meet those autonomy V&V needs, the services they can enable, and point to the certification gaps they fill. To accomplish these goals, we assembled a team of world-class researchers from the aerospace industry (Boeing, Collins Aerospace, and GeneralElectric) and academia (University of Michigan, University of Texas, and Massachusetts Institute of Technology) with deep expertise in autonomy, aerospace systems, and assurance of Artificial Intelligence/machine learning systems.

Software Assurance↗

SU-E-T-555: A Protontherapy Inverse Treatment Planning System Prototype with Linear Energy Transfer (LET) Optimization

Purpose: Develop and benchmark an inverse treatment planning system (TPS) for proton radiotherapy integrating fast analytical dose and LET calculations in patient geometries and a dual objective function with both dose and LET components, enabling us to apply optimization techniques to improve the predicted outcome of treatments based on radiobiological models. Methods: The software package was developed in MATLAB and implements a fluence-dose calculation technique based on a pencil beam model for dose calculations and a 3D LET model based on the extension of the LET in the radial direction as a function of the predicted radiological pathway. Both models were benchmarked against commissioning data from our institution, dose calculations performed with a commercial treatment planning system and Monte Carlo simulations. The optimization is based on the adaptive simulated annealing approach . Results: The dose and LET calculations were tested in a water phantom and several real patient treatments. The pass rate for the gamma index analysis (3%/3mm) test was above 90% for all test cases analyzed, and the calculation time was of the order of seconds. The inverse planning module produced plans with a significantly higher mean LET in the target compared to traditional plans, without any loss of target coverage. The clinical relevance of this improvement is under consideration . Conclusion: The developed treatment planning system is a valuable clinical and research tool that enables us to incorporate LET effects into proton radiotherapy planning in a streamlined fashion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-413: Examining Acquisition Rate for Using MatriXX Ion Chamber Array to Measure HDR Brachytherapy Treatments

Purpose: There are unique obstacles to implementing the MatriXX ionchamber array as a QA tool in Brachytherapy given that the device is designed for use in the MV energy range. One of the challenges we investigate is the affect of acquisition rates on dose measurement accuracy for HDR treatment plans. Methods: A treatment plan was optimized in Oncentra Brachy TPS to deliver a planar dose to a 5×5cm region at 10mm depth. The applicator was affixed to the surface of the MatriXX array. The plan was delivered multiple times using a Nucleatron HDR afterloader with a 2.9Ci Ir192 source. For each measurement the sampling rate of the MatriXX movie mode was varied (30ms and 500ms). This experiment was repeated with identical parameters, following a source exchange, with an 11.2Ci Ir192 source. Finally, a single snap measurement was acquired. Analysis was preformed to evaluate the fidelity of the dose delivery for each iteration of the experiment. Evaluation was based on the comparison between the measured and TPS predicted dose. Results: Higher sample rates induce a greater discrepancy between the predicted and measured dose. Delivering the plan using a lower activity source also produced greater discrepancy in the measurement due to the increased delivery time. Analyzing the single snap measurement showed little difference from the 500ms integral dose measurement. Conclusion: The advantage of using movie mode for HDR treatment delivery QA is the ability for real time source tracking in addition to dose measurement. Our analysis indicates that 500ms is an optimal frame rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

An energy-aware multiobjective ant colony algorithm to minimize total completion time and energy cost on a single-machine preemptive scheduling

Energy-aware scheduling in manufacturing operations with time-of-use electricity tariffs is a challenging problem. Sustainable manufacturing is gaining significant momentum: companies are not only improving their product quality, but also optimizing the production processes to improve energy consumption (i.e., minimizing energy cost) in order to manage environmental challenges which contribute to global climate change. The purpose of this paper is to study a preemptive scheduling problem on a single-machine to minimize the total completion time and total energy cost under time-of-use electricity tariffs, which is a mixed-integer multiobjective mathematical programming model. To solve these objectives, we develop several new holistic ant colony optimization algorithms. The proposed model is solved via several methods including weighted sum method (WSM) using CPLEX, and multiobjective ant colony optimization based on a dominance ranking (ACO-DR) or based on a dominance ranking procedure and crowding distance comparison (ACO-DRC) or based on a heuristic approach to obtain an approximate Pareto-front and also provide information on when to start and resume each job for any solution on the Pareto-front. We provide detailed experimental results evaluating the performance of the proposed algorithms. In a case study, we demonstrate how the results of the multiobjective model could be utilized in decision making using the multiobjective optimization on the basis of ratio analysis (MOORA) method. Furthermore, this proposed model and heuristics allows decision makers to operate in challenging-data enabled environments in industrial internet of things ecosystem, and assists in optimizing production planning to improve energy cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Postoperative Proton Radiotherapy for Localized and Locoregional Breast Cancer: Potential for Clinically Relevant Improvements?

Purpose: To study the potential reduction of dose to organs at risk (OARs) with intensity-modulated proton radiotherapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) photon radiotherapy for left-sided breast cancer patients. Methods and Materials: Comparative treatment-planning was performed using planning computed tomography scans of 20 left-sided breast cancer patients. For each patient, three increasingly complex locoregional volumes (planning target volumes [PTVs]) were defined: whole breast (WB) or chest wall (CW) = (PTV1), WB/CW plus medial-supraclavicular (MSC), lateral-supraclavicular (LSC), and level III axillary (AxIII) nodes = (PTV2) and WB/CW+MSC+LSC+AxIII plus internal mammary chain = (PTV3). For each patient, 3D-CRT, IMRT, and IMPT plans were optimized for PTV coverage. Dose to OARs was compared while maintaining target coverage. Results: All the techniques met the required PTV coverage except the 3D-CRT plans for PTV3-scenario. All 3D-CRT plans for PTV3 exceeded left-lung V20. IMPT vs. 3D-CRT: significant dose reductions were observed for all OARs using IMPT for all PTVs. IMPT vs. IMRT: For PTV2 and PTV3, low (V5) left lung and cardiac doses were reduced by a factor >2.5, and cardiac doses (V22.5) were by a factor of >20 lower with IMPT compared with IMRT. Conclusions: When complex-target irradiation is needed, 3D-CRT often compromises the target coverage and increases the dose to OARs; IMRT can provide better results but will increase the integral dose. The benefit of IMPT is based on improved target coverage and reduction of low doses to OARs, potentially reducing the risk of late-toxicity. These results indicate a potential role of proton-radiotherapy for extended locoregional irradiation in left breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH). The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the contouring uncertainty on V100 and D90 fortunately, has a conservative effect of underestimating the prostate coverage.

60 APPLIED LIFE SCIENCES↗

SU-F-T-527: A Novel Dynamic Multileaf Collimator Leaf-Sequencing Algorithm in Radiation Therapy

Purpose: A novel leaf-sequencing algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimator (MLC). The efficiency of this dynamic MLC leaf-sequencing method was evaluated using external beam treatment plans delivered by intensity modulated radiation therapy technique. Methods: To qualify and validate this algorithm, integral test for the beam segment of MLC generated by the CORVUS treatment planning system was performed with clinical intensity map experiments. The treatment plans were optimized and the fluence maps for all photon beams were determined. This algorithm started with the algebraic expression for the area under the beam profile. The coefficients in the expression can be transformed into the specifications for the leaf-setting sequence. The leaf optimization procedure was then applied and analyzed for clinical relevant intensity profiles in cancer treatment. Results: The macrophysical effect of this method can be described by volumetric plan evaluation tools such as dose-volume histograms (DVHs). The DVH results are in good agreement compared to those from the CORVUS treatment planning system. Conclusion: We developed a dynamic MLC method to examine the stability of leaf speed including effects of acceleration and deceleration of leaf motion in order to make sure the stability of leaf speed did not affect the intensity profile generated. It was found that the mechanical requirements were better satisfied using this method. The Project is sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry.

60 APPLIED LIFE SCIENCES↗

Software for Probabilistic Risk Reduction

A computer program implements a methodology, denoted probabilistic risk reduction, that is intended to aid in planning the development of complex software and/or hardware systems. This methodology integrates two complementary prior methodologies: (1) that of probabilistic risk assessment and (2) a risk-based planning methodology, implemented in a prior computer program known as Defect Detection and Prevention (DDP), in which multiple requirements and the beneficial effects of risk-mitigation actions are taken into account. The present methodology and the software are able to accommodate both process knowledge (notably of the efficacy of development practices) and product knowledge (notably of the logical structure of a system, the development of which one seeks to plan). Estimates of the costs and benefits of a planned development can be derived. Functional and non-functional aspects of software can be taken into account, and trades made among them. It becomes possible to optimize the planning process in the sense that it becomes possible to select the best suite of process steps and design choices to maximize the expectation of success while remaining within budget.

Hensley, Scott↗

Brilliant Execution of Smart Labs: Employing Best Practices to Improve Safety and Reduce Energy for Sustainable Labs: Preprint

Laboratory buildings often dominate the energy use on research campuses, consuming three to four times the energy of a typical office building. In most cases, these facilities are defined as “mission critical,” with excessive energy use as simply an unfortunate truth that cannot be avoided without compromising safety. However, case studies indicate cost savings opportunities of up to 40% in laboratories (compared to standard practices) by employing energy efficient design strategies that also improve the safety of lab spaces (Better Buildings 2018). To help stakeholders implement improvement measures, the Smart Labs Toolkit describes a proven approach to optimizing performance of laboratories and critical control environments in new or existing facilities. The Toolkit outlines distinct phases for building a successful Smart Labs program that include: Plan, Assess, Optimize, and Manage. Each phase has specific tasks, training videos, and resources to educate users, support the efforts of key stakeholders, and maximize benefits for the organization in implementing high-performance labs. The Toolkit also includes case studies from the 17 Better Buildings Smart Labs Accelerator partners, sharing lessons learned and supporting the Smart Labs approach to safe, efficient world class science. This paper reviews the technology choices for implementing Smart Labs ventilation strategies, controls, and other efficiency measures. Better Building Smart Lab Accelerator partners provide case study examples of safety and energy-savings results of using Smart Labs approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-202-01: Incorporating Time-Dependent Hypoxia in IMRT Planning

Purpose: To incorporate uncertainties in oxygenation of tumor cells into radiation therapy planning via robust optimization. The model is demonstrated using a clinical prostate cancer case. Methods: The tumor oxygenation levels are determined based on pre- and mid-treatment PET scans. To account for oxygenation changes, we use a radio-sensitivity factor for the effective dose necessary to treat hypoxic cells. Due to the unpredictable nature of re-oxygenation of hypoxic cells, the radio-sensitivity factor and its change is modeled to reside in a time-dependent uncertainty set. This uncertainty can adapt to both pre- and mid-treatment scans, resulting in a two-stage robust treatment planning model. We develop a robust counterpart reformulation that transforms the original NP-hard problem into a linear program consisting of finitely many linear constraints, which can be solved efficiently. Results: The robust plan is compared to both the corresponding fractionated plan which ignores hypoxia, and to the commonly practiced dose-escalated plan that uniformly increases dose based on initial oxygen concentrations. For PTV, the robust plan improves D{sub 50}, D{sub 95}, and EUD by 4% on average compared to fractionated, and by 11% compared to the optimal escalated plan. Moreover, the robust plan spared organs at risk similar to the fractionated plan, while the escalated plan led to over 170% increase of Bladder D{sub 30}. Conclusion: The proposed robust adaptive model can improve tumor coverage by increasing dose to hypoxic tumor voxels that is overlooked by common fractionated treatments. In addition, the robust model anticipates the re-oxygenation process, thus reducing the excess dose at later fractions in comparison to uniform dose-escalation methods.

60 APPLIED LIFE SCIENCES↗

Inspection planning development: An evolutionary approach using reliability engineering as a tool

This paper proposes an evolutionary approach for inspection planning which introduces various reliability engineering tools into the process and assess system trade-offs among reliability, engineering requirement, manufacturing capability and inspection cost to establish an optimal inspection plan. The examples presented in the paper illustrate some advantages and benefits of the new approach. Through the analysis, reliability and engineering impacts due to manufacturing process capability and inspection uncertainty are clearly understood; the most cost effective and efficient inspection plan can be established and associated risks are well controlled; some inspection reductions and relaxations are well justified; and design feedbacks and changes may be initiated from the analysis conclusion to further enhance reliability and reduce cost. The approach is particularly promising as global competitions and customer quality improvement expectations are rapidly increasing.

Graf, David A.↗

Multicriteria VMAT optimization

Purpose: To make the planning of volumetric modulated arc therapy (VMAT) faster and to explore the tradeoffs between planning objectives and delivery efficiency. Methods: A convex multicriteria dose optimization problem is solved for an angular grid of 180 equi-spaced beams. This allows the planner to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus organ at risk sparing. The selected plan is then made VMAT deliverable by a fluence map merging and sequencing algorithm, which combines neighboring fluence maps based on a similarity score and then delivers the merged maps together, simplifying delivery. Successive merges are made as long as the dose distribution quality is maintained. The complete algorithm is called VMERGE. Results: VMERGE is applied to three cases: a prostate, a pancreas, and a brain. In each case, the selected Pareto-optimal plan is matched almost exactly with the VMAT merging routine, resulting in a high quality plan delivered with a single arc in less than 5 min on average. Conclusions: VMERGE offers significant improvements over existing VMAT algorithms. The first is the multicriteria planning aspect, which greatly speeds up planning time and allows the user to select the plan, which represents the most desirable compromise between target coverage and organ at risk sparing. The second is the user-chosen epsilon-optimality guarantee of the final VMAT plan. Finally, the user can explore the tradeoff between delivery time and plan quality, which is a fundamental aspect of VMAT that cannot be easily investigated with current commercial planning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRD-12: When Does Pencil Beam Scanning Become Superior to Passive Scattered Proton Therapy for Pediatric Head and Neck Cancers?

Purpose: To investigate the dosimetric benefits of pencil beam scanning (PBS) compared with passive scattered (PS) proton therapy for treatment of pediatric head&neck patients as a function of the PBS spot size and explore the advantages of using apertures in PBS. Methods: Ten pediatric patients with head&neck cancers treated by PS proton therapy at our institution were retrospectively selected. The histologies included rhabdomyosarcoma, ependymoma, astrocytoma, craniopharyngioma and germinoma. The prescribed dose ranged from 36 to 54 Gy(RBE). Five PBS plans were created for each patient using variable spot size (average sigma at isocenter) and choice of beam specific apertures: (1) 10mm spots, (2) 10mm spots with apertures, (3) 6mm spots, (4) 6mm spots with apertures, and (5) 3mm spots. The plans were optimized for intensity modulated proton therapy (IMPT) with no single beam uniformity constraints. Dose volume indices as well as equivalent uniform dose (EUD) were compared between PS and PBS plans. Results: Although target coverage was clinically adequate for all cases, the plans with largest (10mm) spots provide inferior quality compared with PS in terms of dose to organs-at-risk (OAR). However, adding apertures to these plans ensured lower OAR dose than PS. The average EUD difference between PBS and PS plans over all patients and organs at risk were (1) 2.5%, (2) −5.1%, (3) -5%, (4) −7.8%, and (5) −9.5%. As the spot size decreased, more conformal plans were achieved that offered similar target coverage but lower dose to the neighboring healthy organs, while alleviating the need for using apertures. Conclusion: The application of PBS does not always translate to better plan qualities compared to PS depending on the available beam spot size. We recommend that institutions with spot size larger than ∼6mm at isocenter consider using apertures to guarantee clinically comparable or superior dosimetric efficacy to PS treatments.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 03: The Potential Benefit Of Esophageal Sparing During Palliative Radiotherapy For Lung Cancer

Puropose: Palliative radiotherapy is an effective technique to alleviate systems of disease burden in late-stage lung cancer patients. Previous randomized controlled studies demonstrated a survival benefit in patients with good performance status at radiation doses of 35Gy10 or greater but with an increased incidence of esophagitis. The objective of this planning study was to assess the potential impact of esophageal-sparing IMRT (ES-IMRT) compared to the current standard of care using parallel-opposed pair beams (POP). Methods: In this study, 15 patients with lung cancer treated to a dose of 30Gy in 10 fractions between August 2015 and January 2016 were identified. Radiation treatment plans were optimized using ES-IMRT by limiting the max esophagus point dose to 24Gy. Using published Lyman-Kutcher-Burman normal tissue complication probabilities (LKB-NTCP) models, both plans were evaluated for the likelihood of esophagitis (≥ grade 2) and pneumonitis (≥ grade 2). Results: Using ES-IMRT, the median esophageal and lung mean doses reduced from 16 and 8Gy to 7 and 7Gy, respectively. Using the LKB models, the theoretical probability of symptomatic esophagitis and pneumonitis reduced from 13 to 1%, and from 5 to 3%, respectively. The median NTD mean for the GTV and PTV of the clinically approved POP plans compared to the ES-IMRT plans were similar. Conclusions: Advanced radiotherapy techniques such as ES-IMRT may have clinical utility in reducing treatment-related toxicity in advanced lung cancer patients. Our data suggests that the rate of esophagitis can be reduced without compromising tumour control.

60 APPLIED LIFE SCIENCES↗