Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

OARE STS-94 (MSL-1R)

The report is organized into sections representing the phases of work performed in analyzing the STS-94 (MSL-IR) results. STS-94 (MSL1R) is a reflight of the STS-83 (MSL-1) mission which was terminated early because of a fuel cell problem. Section I briefly outlines the OARE system features, coordinates, and measurement parameters. Section 2 describes the results from STS-94. The mission description, data calibration, and representative data obtained on STS-94 are presented. Also, the anomalous performance of OARE on STS-94 is discussed. Finally, Section 3 presents a discussion of accuracy achieved and achievable with OARE. Appendix A discuss the calibration and data processing methodology in detail.

Rice, James E.↗

OARE STS-87 (USMP-4)

The report is organized into sections representing the phases of work performed in analyzing the STS-87 (USMP-4) results. Section 1 briefly outlines the OARE system features, coordinates, and measurement parameters. Section 2 describes the results from STS-87. The mission description, data calibration, and representative data obtained on STS-87 are presented. Finally, Section 3 presents a discussion of accuracy achieved and achievable with OARE. Appendix A discusses the calibration and data processing methodology in detail.

Rice, James E.↗

Hybrid Gibbs Sampling and MCMC for CMB Analysis at Small Angular Scales

A) Gibbs Sampling has now been validated as an efficient, statistically exact, and practically useful method for "low-L" (as demonstrated on WMAP temperature polarization data). B) We are extending Gibbs sampling to directly propagate uncertainties in both foreground and instrument models to total uncertainty in cosmological parameters for the entire range of angular scales relevant for Planck. C) Made possible by inclusion of foreground model parameters in Gibbs sampling and hybrid MCMC and Gibbs sampling for the low signal to noise (high-L) regime. D) Future items to be included in the Bayesian framework include: 1) Integration with Hybrid Likelihood (or posterior) code for cosmological parameters; 2) Include other uncertainties in instrumental systematics? (I.e. beam uncertainties, noise estimation, calibration errors, other).

Gibbs sampling↗

Science from Kepler Collateral Data: 50 Kilosecond per Year from 13 Million Stars

As each Kepler frame is read out, light from each star in a CCD column accumulates in successive pixels as they wait for the next row to be read out. This accumulation is the same in the masked rows at the start of the readout and virtual rows at the end of the readout as it is in the science data. A range of these "smear" rows are added together for each long cadence and sent to the ground for calibration purposes. We will introduce and describe this smear collateral data, discuss and demonstrate its potential use for scientific studies exclusive of Kepler calibration,[1,2] including global characteristics of stellar variability, which are influenced by parameters of galactic evolution.

Kolodziejczak, J. J.↗

Airborne Topographic Mapper Calibration Procedures and Accuracy Assessment

Description of NASA Airborn Topographic Mapper (ATM) lidar calibration procedures including analysis of the accuracy and consistancy of various ATM instrument parameters and the resulting influence on topographic elevation measurements. The ATM elevations measurements from a nominal operating altitude 500 to 750 m above the ice surface was found to be: Horizontal Accuracy 74 cm, Horizontal Precision 14 cm, Vertical Accuracy 6.6 cm, Vertical Precision 3 cm.

Martin, Chreston F.↗

4DoF Drift Free Navigation Using Inertial Cues and Optical Flow

In this paper, we describe a novel approach in fusing optical flow with inertial cues (3D acceleration and 3D angular velocities) in order to navigate a Micro Aerial Vehicle (MAV) drift free in 4DoF and metric velocity. Our approach only requires two consecutive images with a minimum of three feature matches. It does not require any (point) map nor any type of feature history. Thus it is an inherently failsafe approach that is immune to map and feature-track failures. With these minimal requirements we show in real experiments that the system is able to navigate drift free in all angles including yaw, in one metric position axis, and in 3D metric velocity. Furthermore, it is a power-on-and-go system able to online self-calibrate the inertial biases, the visual scale and the full 6DoF extrinsic transformation parameters between camera and IMU.

reconnissance↗

Variations in Visible/Near-Infrared Hematite Spectra Related to Grain Size and Crystallinity

Drill fines created by the Curiosity rover at Gale Crater, Mars have exhibited variable visible/near-infrared spectral features attributable to the presence of ferrous and ferric minerals. Drilled locations within the Murray formation and on the Vera Rubin Ridge (VRR) were shown by the CheMin instrument to contain significant amounts of hematite. However, typical hematite spectral features (e.g., absorptions near 530 nm and 860 nm) have varied inconsistently with hematite abundances. This suggests that other factors such as hematite grain size or crystallinity, the presence of amorphous materials, and/or photometric effects play a role in the observed spectra. Using laboratory spectra of hematite acquired at difference grain sizes, we document the variability in key spectral features. We also compare spectral parameters computed from Mastcam spectra on Mars of three hematite-bearing ChemCam calibration target (CCCT) samples with known hematite and amorphous material abundances.

Johnson, J. R.↗

Parameterization-Induced Uncertainties and Impacts of Crop Management Harmonization in a Global Gridded Crop Model Ensemble

Global gridded crop models (GGCMs) combine agronomic or plant growth models with gridded spatial input data to estimate spatially explicit crop yields and agricultural externalities at the global scale. Differences in GGCM outputs arise from the use of different biophysical models, setups, and input data. GGCM ensembles are frequently employed to bracket uncertainties in impact studies without investigating the causes of divergence in outputs. This study explores differences in maize yield estimates from five GGCMs based on the public domain field-scale model Environmental Policy Integrated Climate (EPIC) that participate in the AgMIP Global Gridded Crop Model Intercomparison initiative. Albeit using the same crop model, the GGCMs differ in model version, input data, management assumptions, parameterization, and selection of subroutines affecting crop yield estimates via cultivar distributions, soil attributes, and hydrology among others. The analyses reveal inter-annual yield variability and absolute yield levels in the EPIC-based GGCMs to be highly sensitive to soil parameterization and crop management. All GGCMs show an intermediate performance in reproducing reported yields with a higher skill if a static soil profile is assumed or sufficient plant nutrients are supplied. An in-depth comparison of setup domains for two EPIC-based GGCMs shows that GGCM performance and plant stress responses depend substantially on soil parameters and soil process parameterization, i.e. hydrology and nutrient turnover, indicating that these often neglected domains deserve more scrutiny. For agricultural impact assessments, employing a GGCM ensemble with its widely varying assumptions in setups appears the best solution for coping with uncertainties from lack of comprehensive global data on crop management, cultivar distributions and coefficients for agro-environmental processes. However, the underlying assumptions require systematic specifications to cover representative agricultural systems and environmental conditions. Furthermore, the interlinkage of parameter sensitivity from various domains such as soil parameters, nutrient turnover coefficients, and cultivar specifications highlights that global sensitivity analyses and calibration need to be performed in an integrated manner to avoid bias resulting from disregarded core model domains. Finally, relating evaluations of the EPIC-based GGCMs to a wider ensemble based on individual core models shows that structural differences outweigh in general differences in configurations of GGCMs based on the same model, and that the ensemble mean gains higher skill from the inclusion of structurally different GGCMs. Although the members of the wider ensemble herein do not consider crop-soil-management interactions, their sensitivity to nutrient supply indicates that findings for the EPIC-based sub-ensemble will likely become relevant for other GGCMs with the progressing inclusion of such processes.

Folberth, Christian↗

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

Evaluation of the Hinge Moment and Normal Force Aerodynamic Loads from a Seamless Adaptive Compliant Trailing Edge Flap in Flight

A seamless adaptive compliant trailing edge (ACTE) flap was demonstrated in flight on a Gulfstream III aircraft at the NASA Armstrong Flight Research Center. The trailing edge flap was deflected between minus 2 deg up and plus 30 deg down in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The interface hardware instrumentation layout and load calibration are discussed. Twenty-one applied calibration test load cases were developed for each individual fitting. The 2-sigma residual errors for the hinge moment was calculated to be 2.4 percent, and for normal force was calculated to be 7.3 percent. The hinge moment and normal force generated by the ACTE flap with a hinge point located at 26-percent wing chord were measured during steady state and symmetric pitch maneuvers. The loads predicted from analysis were compared to the loads observed in flight. The hinge moment loads showed good agreement with the flight loads while the normal force loads calculated from analysis were over-predicted by approximately 20 percent. Normal force and hinge moment loads calculated from the pressure sensors located on the ACTE showed good agreement with the loads calculated from the installed strain gages.

Hinge Moment Loads↗

Calibrations of phase abundance, composition, and particle size distribution for olivine-orthopyroxene mixtures from reflectance spectra

An analytical method for quantifying the characteristics (phase abundances, phase composition, and grain size) of an olivine-orthopyroxene mixture from reflectance spectra is described. The spectral parameters related to reflectance, wavelength position, and albedo are investigated; the absorption bands for the olivine-orthopyroxene mixture is also studied. Primary calibrations useful for the determination of the olivine-orthopyroxene mixture characteristics are examined.

Cloutis, Edward A.↗

Breathing metabolic simulator

The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

Bartlett, R. G.↗

Calibration and evaluation of Skylab altimetry for geodetic determination of the geoid

The author has identified the following significant results. The analysis was based on a time series intrinsic relationship between the satellite ephemeris, altimeter measured ranges, and the corresponding a priori values of subsatellite geoidal heights. Using, least squares processing with parameter weighting, the objective was to recover: (1) the absolute geoidal heights of the subsatellite points; and (2) the associated altimeter calibration constants. Preliminary results from Skylab mission SL-2 are given, using various combinations from two sets of orbit ephemeris and altimeter ranges. It is shown that correctly scaled geoidal heights cannot be deduced by merely subtracting the altimeter range from the geodetic height of the satellite unless the satellite ephemeris and the altimeter have no unknown significant systematic errors or biases and drifts. It is emphasized that the primary objective of the Skylab altimeter is to determine the instrument feasibility. Any additional applications of the data such as for geodesy, geophysics, and oceanography are desirable. Although accurate orbit is required for such applications, it is not a prerequisite for determining the instrument feasibility.

Mourad, A. G.↗

Absolute Radiometric Calibration of Narrow-Swath Imaging Sensors with Reference to Non-Coincident Wide-Swath Sensors

An inter-calibration method is developed to provide absolute radiometric calibration of narrow-swath imaging sensors with reference to non-coincident wide-swath sensors. The method predicts at-sensor radiance using non-coincident imagery from the reference sensor and knowledge of spectral reflectance of the test site. The imagery of the reference sensor is restricted to acquisitions that provide similar view and solar illumination geometry to reduce uncertainties due to directional reflectance effects. Spectral reflectance of the test site is found with a simple iterative radiative transfer method using radiance values of a well-understood wide-swath sensor and spectral shape information based on historical ground-based measurements. At-sensor radiance is calculated for the narrow-swath sensor using this spectral reflectance and atmospheric parameters that are also based on historical in situ measurements. Results of the inter-calibration method show agreement on the 2 5 percent level in most spectral regions with the vicarious calibration technique relying on coincident ground-based measurements referred to as the reflectance-based approach. While the variability of the inter-calibration method based on non-coincident image pairs is significantly larger, results are consistent with techniques relying on in situ measurements. The method is also insensitive to spectral differences between the sensors by transferring to surface spectral reflectance prior to prediction of at-sensor radiance. The utility of this inter-calibration method is made clear by its flexibility to utilize image pairings with acquisition dates differing in excess of 30 days allowing frequent absolute calibration comparisons between wide- and narrow-swath sensors.

McCorkel, Joel↗

Digital Correlation Microwave Polarimetry: Analysis and Demonstration

The design, analysis, and demonstration of a digital-correlation microwave polarimeter for use in earth remote sensing is presented. We begin with an analysis of three-level digital correlation and develop the correlator transfer function and radiometric sensitivity. A fifth-order polynomial regression is derived for inverting the digital correlation coefficient into the analog statistic. In addition, the effects of quantizer threshold asymmetry and hysteresis are discussed. A two-look unpolarized calibration scheme is developed for identifying correlation offsets. The developed theory and calibration method are verified using a 10.7 GHz and a 37.0 GHz polarimeter. The polarimeters are based upon 1-GS/s three-level digital correlators and measure the first three Stokes parameters. Through experiment, the radiometric sensitivity is shown to approach the theoretical as derived earlier in the paper and the two-look unpolarized calibration method is successfully compared with results using a polarimetric scheme. Finally, sample data from an aircraft experiment demonstrates that the polarimeter is highly-useful for ocean wind-vector measurement.

Piepmeier, J. R.↗

The Colorado IUE active galaxy survey. I - Blazars

This paper presents consistently reduced UV continuum flux densities amd spectra indices derived from all 499 usable archived IUE observations of blazars made through mid-1991. The extraction of 1D spectra and the measurement of spectral parameters are discussed. A detailed error analysis is presented, including a discussion of the difference in the calibration between the IUE long- and short-wavelength cameras. The resulting data are presented in tabular and graphical form and are available by electronic mail as well. These results will be most useful for variability studies, but can also be used to characterize the broad-band energy distributions and to compare blazar properties with those of other AGN. This is the first in a series of papers, in which extracted spectral parameters will be published for the over 4500 spectra of AGN in the IUE archives.

Edelson, Rick↗

Inference of geophysical parameters from multifrequency polarimetric radar observations and model inversion

In summer 1988 an intensive field experiment was conducted in the vicinity of the Pisgah lava flow in the Mojave Desert. Physical properties such as microtopography, composition, soil moisture, and dielectric constant were measured at five sites representing surfaces with rms heights varying from less than one centimeter to tens of centimeters. In addition, polarimetric radar images at P-band, L-band, and C-band were acquired at three different incidence angles with the NASA/JPL airborne imaging radar polarimeter. Using trihedral corner reflectors deployed in the area prior to imaging, the L- and C-band images were calibrated to provide sigma0 values for each resolution element in the scene. The results of inferring geophysical parameters such as rms surface height and correlation length of the measured surfaces by fitting the observed signatures with those predicted by the small-perturbation model are presented: for smoother surfaces, the rms height values inferred are in good agreement with in situ measurements.

Van Zyl, J. J.↗