Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

Low-Outgassing Photogrammetry Targets for Use in Outer Space

A short document discusses an investigation of materials for photogrammetry targets for highly sensitive optical scientific instruments to be operated in outer space and in an outer-space-environment- simulating thermal vacuum chamber on Earth. A key consideration in the selection of photogrammetry-target materials for vacuum environments is the need to prevent contamination that could degrade the optical responses of the instruments. Therefore, in addition to the high levels and uniformity of reflectivity required of photogrammetry-target materials suitable for use in air, the materials sought must exhibit minimal outgassing. Commercially available photogrammetry targets were found to outgas excessively under the thermal and vacuum conditions of interest; this finding prompted the investigators to consider optically equivalent or superior, lower-outgassing alternative target materials. The document lists several materials found to satisfy the requirements, but does not state explicitly whether the materials can be used individually or must be combined in the proper sequence into layered target structures. The materials in question are an aluminized polyimide tape, an acrylic pressure- sensitive adhesive, a 500-A-thick layer of vapor-deposited aluminum, and spherical barium titanate glass beads having various diameters from 20 to 63 microns..

Gross, Jason N.↗

Instrumentation for Sensitive Gas Measurements

An improved instrument for optical absorption spectroscopy utilizes off-axis paths in an optical cavity in order to increase detection sensitivity while suppressing resonance effects. The instrument is well suited for use in either cavity ring-down spectroscopy (CRDS) [in which one pulses an incident light beam and measures the rate of decay of light in the cavity] or integrated cavity output spectroscopy (ICOS) [in which one uses a continuous-wave incident light beam and measures the power of light in the cavity as a function of wavelength]. Typically, in optical absorption spectroscopy, one seeks to measure absorption of a beam of light in a substance (usually a gas or liquid) in a sample cell. In CRDS or ICOS, the sample cell is placed in (or consists of) an optical cavity, so that one can utilize multiple reflections of the beam to increase the effective optical path length through the absorbing substance and thereby increase the sensitivity for measuring absorption. If an absorbing substance is not present in the optical cavity, one can utilize the multiple passes of the light beam to increase the sensitivity for measuring absorption and scattering by components of the optical cavity itself. It is desirable to suppress the effects of resonances in the cavity in order to make the spectral response of the cavity itself as nearly constant as possible over the entire wavelength range of interest. In the present instrument, the desired flattening of the spectral response is accomplished by utilizing an off-axis beam geometry to effectively decrease the frequency interval between longitudinal electromagnetic modes of the cavity, such that the resulting transmission spectrum of the cavity is nearly continuous: in other words, the cavity becomes a broad-band optical device.

OKeefe, Anthony↗

Hermetic Glass-To-Metal Seal For Instrumentation Window

Proposed mounting scheme for optical element of instrumentation window in pressure vessel ensures truly hermetic seal while minimizing transmission of stress to optical element. Brazed metal seal superior to conventional gaskets of elastomer, carbon, asbestos, or other material compressed between optical element and wall of vessel. Concentric brazed joints in proposed seal bond metal ring to wall of vessel and to optical element. U-shaped cross section allows ring to flex under pressure.

Hill, Arthur J.↗

Efficient multiple beam ion optics for quantitative surface analysis : from simulations to a fully operational instrument.

A new ion optics system was developed and experimentally tested, which allows for high-resolution multiple beam characterization of materials. This system enables: (1) efficient, quasi-simultaneous measurements of the mass spectra of laser post-ionized sputtered species and secondary ions as well as secondary electron imaging, that can be accompanied and assisted by (2) low energy ion milling and (3) in-situ optical imaging and laser desorption with submicron resolution. Altogether, this ion optics system provides a versatile, sensitive combination of an analytical mass spectrometer and ion, electron and optical microscopes, which can efficiently detect one out of four sample atoms consumed during the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Scalable stable comb-to-tone integrated RF photonic drive for superconducting qubits

The recent advent of quantum computing has the potential to overhaul security, communications, and scientific modeling. Superconducting qubits are a leading platform that is advancing noise-tolerant intermediate-scale quantum processors. The implementation requires scaling to large numbers of superconducting qubits, circuit depths, and gate speeds, wherein high-purity RF signal generation and effective cabling transport are desirable. Fiber photonic-enhanced RF signal generation has demonstrated the principle of addressing both signal generation and transport requirements, supporting intermediate qubit numbers and robust packaging efforts; however, fiber-based approaches to RF signal distribution are often bounded by their phase instability. Here, we present a silicon photonic integrated circuit-based version of a photonic-enhanced RF signal generator that demonstrates the requisite stability, as well as a path towards the necessary signal fidelity.

47 OTHER INSTRUMENTATION↗

Fiber optic sensors

A survey of the developments in the field of fiber optics sensor technology is presented along with a discussion of the advantages of optical measuring instruments as compared with electronic sensors. The two primary types of fiber optics sensors, specifically those with multiwave fibers and those with monowave fibers, are described. Examples of each major sensor type are presented and discussed. Multiwave detectors include external and internal fiber optics sensors. Among the monowave detectors are Mach-Zender interferometers, Michelson interferometers, Sagnac interferometers (optical gyroscopes), waveguide resonators, and polarimeter sensors. Integrated optical sensors and their application in spectroscopy are briefly discussed.

Hesse, J.↗

The JPL Field Emission Spectrometer

The Jet Propulsion Laboratory (JPL) Field Emission Spectrometer (FES) was built by Designs and Prototypes based on a set of functional requirements supplied by JPL. The instrument has a spectral resolution of 6 wavenumbers (wn) and can acquire spectra from either the Mid Infrared (3-5 mu m) or the Thermal Infrared (8-12 pm) depending on whether the InSb or HgCdTe detector is installed respectively. The instrument consists of an optical head system unit and battery. The optical head which is tripod mounted includes the interferometer and detector dewar assembly. Wavelength calibration of the interferometer is achieved using a Helium-Neon laser diode. The dewar needs replenishing with liquid Nitrogen approximately every four hours. The system unit includes the controls for operation and the computer used for acquiring viewing and processing spectra. Radiometric calibration is achieved with an external temperature-controlled blackbody that mounts on the fore-optics of the instrument. The blackbody can be set at 5 C increments between 10 and 55 C. The instrument is compact and weighs about 33 kg. Both the wavelength calibration and radiometric calibration of the instrument have been evaluated. The wavelength calibration was checked by comparison of the position of water features in a spectrum of the sky with their position in the output from a high resolution atmospheric model. The results indicatethat the features in the sky spectrum are within 6-8 wn of their position ill the model spectrum. The radiometric calibration was checked by first calibrating the instrument using the external blackbody supplied with the instrument and then measuring the radiance from another external blackbody at a series of temperatures. The temperatures of these radiance spectra were then recovered by inventing Planck's law and the recovered temperatures compared lo the measured blackbody temperature. These results indicate that radiometric calibration is good to 0.5 C over the range of temperatures 10 to 55 C. The results also indicate that the instrument drifts slowly over time and should be recalibrated every 20 to 30 minutes in the field to ensure good radiometric fidelity. The instrument has now been extensively tested in the field in the United States and Australia. These in situ field measurements are being used to validate emissivity spectra recovered from the Thermal Infrared Multispectral Scanner (TIMS) and also the Australian CO2 Laser. The availability of in situ measurements is proving crucial to validation of the spectra derived from the airborne instruments since many natural surfaces cannot be easily transported back to the laboratory.

Hook, Simon J.↗

The Marshall 100-Meter X-ray Beamline

The Marshall 100-Meter X-ray Beamline is a user facility for x-ray and EUV optics and instrumentation calibration, located at NASA’s Marshall Space Flight Center in Huntsville, Alabama. Also known as the Stray Light Test Facility, the Marshall-100 provides a range of focal plane detectors, x-ray sources, translation stages, cleanrooms, and high-vacuum level capability to the high-energy astrophysics community. Facility time is made available to Astronomy and Physics Research and Analysis (APRA) funded projects and is also available to the broader community upon request made to beamline management. The beamline has successfully been employed in the calibration of larger scope projects such as the Spectrum-Roentgen-Gamma Astronomical Roentgen Telescope X-ray Concentrator (ART-XC) telescope and the Small Explorer (SMEX) class Imaging X-ray Polarimetry Explorer (IXPE) Space Telescope. Additionally, the Marshall-100 is instrumental in supporting testing related to MSFC’s high-angular resolution optics development program.

X-ray Beamline, Test Facility, X-ray Calibration↗

Multiparameter fiber optic sensing system for monitoring enhanced geothermal systems

The goal of this project was to design, fabricate and test an optical fiber cable which supports multiple sensing modalities for measurements in the harsh environment of enhanced geothermal systems. To accomplish this task, optical fiber was tested at both high temperatures and strains for mechanical integrity, and in the presence of hydrogen for resistance to darkening. Both single mode (SM) and multimode (MM) commercially available optical fiber were identified and selected for the cable based on the results of these tests. The cable was designed and fabricated using a tube-within-tube construction containing two MM fibers and one SM fiber, and without supporting gel that is not suitable for high temperature environments. Commercial fiber optic sensing instruments using Raman DTS (distributed temperature sensing), Brillouin DTSS (distributed temperature and strain sensing), and Raleigh COTDR (coherent optical time domain reflectometry) were selected for field testing.

15 GEOTHERMAL ENERGY↗

A SATELLITE AGNOSTIC APPROACH TO QUANTIFYING HAIL DAMAGE SWATHS ACROSS THE CENTRAL UNITED STATES AND OTHER AGRICULTURAL REGIONS

Intense thunderstorms can bring damaging winds and large hail to agricultural regions during the prime growing season. In certain cases, large swaths of damage from the wind and hail are left behind and visible to satellite remote sensing instruments. Often times, Earth observing optical remote sensing from low to high spatial resolutions are able to view these damaged swaths. With the large number of moderate to high-resolution instruments in orbit, these damaged areas have potential to be viewed daily. However, during the prime growing season, clouds frequently block the viewing of the land surface by these optical instruments. Space-borne synthetic aperture radar (SAR) instruments allow for the viewing of the land surface in most weather conditions, but instead measure backscatter as opposed to optical sensors measuring reflected or emitted radiation. Additionally, the number of SAR instruments with free and open data lags behind the number of optical sensors. This paper describes the development of a methodology that attempts to characterize hail damaged swaths, through independent use of multiple optical and SAR platforms. This satellite-agnostic approach will focus statistical analysis by comparing undamaged areas to suspected damaged areas by using commonly derived indices from optical instruments and SAR backscatter from multiple polarizations.

Jordan R Bell↗

Investigation of Space Based Solid State Coherent Lidar

This report describes the work performed over the period of October 1, 1997 through March 31, 2001. Under this contract, UAH/CAO participated in defining and designing the SPAce Readiness Coherent Lidar Experiment (SPARCLE) mission, and developed the instrument's optical subsystem. This work was performed in collaborative fashion with NASA/MSFC engineers at both UAH/CAO and NASA/MSFC facilities. Earlier work by the UAH/CAO had produced a preliminary top-level system design for the Shuttle lidar instrument meeting the proposed mission performance requirements and the Space Shuttle Hitchhiker canister volume constraints. The UAH/CAO system design efforts had concentrated on the optical and mechanical designs of the instrument. The instrument electronics were also addressed, and the major electronic components and their interfaces defined. The instrument design concept was mainly based on the state of the transmitter and local oscillator laser development at NASA Langley Research Center and Jet Propulsion Laboratory, and utilized several lidar-related technologies that were either developed or evaluated by the NASA/MSFC and UAH/CAO scientists. UAH/CAO has developed a comprehensive coherent lidar numerical model capable of analyzing the performance of different instrument and mission concepts. This model uses the instrument configuration, atmospheric conditions and current velocity estimation theory to provide prediction of instrument performance during different phases of operation. This model can also optimize the design parameters of the instrument.

Amzajerdian, Farzin↗

A NVLAP Accredited Process for Transfer of Calibration to High Energy Laser Probes

Experiments conducted at national user facilities, such as the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL), employ state-of-the-art instrumentation including optical and X-ray streak cameras, gated imagers, CCDs, and diodes. These instruments are characterized to ensure the diagnostics perform reliably, and data collected during their use will be traceable to relevant standards. A process accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) was developed for transferring the calibration of pulsed high energy laser probes from a standard calibrated by the National Institute of Standards and Testing (NIST) to additional energy probes for use as general working standards. We will discuss the unique challenges of developing the measurement methodologies associated with this calibration transfer, and the analysis of error propagation as it pertains to the expanded uncertainty of the calibration measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Development Work with Self-Aligned Focusing Schlieren

A novel compact focusing schlieren instrument has recently been developed that eliminates the need for a separate source and cutoff grid. The technique works by projecting an image of a grid onto a retroreflective surface and then reimaging the projection back onto the original grid. By manipulating the polarization state of the light passing through the instrument, a single Rochon polarizing prism can be used to adjust the schlieren sensitivity by translating it along the instrument’s optical axis, which changes the in-plane offset between the reimaged projection and the original grid. This arrangement makes the instrument inherently self-aligned. Relative to conventional focusing schlieren instruments, which require alignment of a separate source grid and cutoff grid to achieve sensitivity, the setup time required in order to obtain high quality focusing schlieren images is significantly reduced. Further, the self-aligned nature of this instrument makes it insensitive to vibrations and allows for on-the-fly adjustments to field-of-view. In this paper we discuss recent work that has been performed to expand the capabilities of this self-aligned focusing schlieren instrument including: schlieren visualization at extreme angles for optically-restricted test facilities, 3D schlieren visualization using a light field camera, acquisition of high quality focusing schlieren images from facilities with low quality windows, and obtaining focusing schlieren images in full-scale ground test facilities.

Brett Bathel↗

Scintillation properties and increased vacancy formation in cerium and calcium co-doped yttrium aluminum garnet

Co-doping with divalent elements is known to improve the light yield and decay times of some cerium-activated scintillators, despite the stabilization of tetravalent Ce 4+ , previously believed to be non-luminescent, from the Ce 3+ state. Ce 4+ stabilization is a charge compensation mechanism which results from divalent ion substitution of a 3+site. To elucidate the underlying mechanisms, which remain poorly understood, we have grown three Ce,Ca:YAG crystals with different amounts of calcium co-dopants by the Czochralski method and characterized their scintillation and defect properties. Calcium co-doping reduces the decay times and stabilizes the formation of Ce 4+ as expected. Interestingly, X-ray fluorescence analysis reveals a decreased concentration of cerium within the YAG crystal for the sample doped with high levels of Ca, which could contribute to the observation that scintillator properties are improved only for low levels of Ca co-doping. Additionally, positron annihilation spectroscopy reveals an increase in the concentration of vacancies with increasing Ca concentration, while thermoluminescence is observed to show no detectable signal. Furthermore, room temperature photoluminescence of the Ce 4f to 5d 1 transition demonstrates decreased emission with increasing Ca co-doping. These data suggest that Ca co-doping decreases the decay time by creating defects with non-radiative decay pathways.

36 MATERIALS SCIENCE↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗