Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Medium-resolution Autonomous in situ Gamma Detection System for Marine and Coastal Waters

We are developing a medium-resolution autonomous in situ gamma detection system for marine and coastal waters. The system is designed to extract and preconcentrate isotopes of interest from natural waters prior to detection in order to eliminate signal attenuation of the gamma rays traveling through water and lower the overall background due to the presence of naturally occurring radioactive isotopes (40K and U/Th series radionuclides). Filtration is used to preconcentrate target isotopes residing on suspended particles, while chemosorption is employed to preferentially extract truly dissolved components from the water column. A variety of commercial and in-house nano-porus chemosorbents have been selected, procured or produced, and tested. Used filter and chemosorbent media are counted autonomously using two LaBr3 detectors in a near 4-pi configuration around the samples. A compact digital pulse processing system developed in-house and capable of running in coincidence mode is used to process the signal from the detectors to a small on-board computer. The entire system is extremely compact (9” dia. x 30” len.) and platform independent, but designed for initial deployment on a research buoy.

Gamma ray spectrometry↗

RADSAT Benchmarks for Prompt Gamma Neutron Activation Analysis Measurements

The accurate and efficient simulation of coupled neutron-photon problems is necessary for several important radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples. High-resolution gamma-ray spectrometers are used in these applications to measure the spectrum of the emitted photon flux, which consists of both continuum and characteristic gamma rays with discrete energies. Monte Carlo transport is the most commonly used simulation tool for this type of problem, but computational times can be prohibitively long. This work explores the use of multi-group deterministic methods for the simulation of coupled neutron-photon problems. The main purpose of this work is to benchmark several problems modeled with RADSAT and MCNP to experimental data. Additionally, the cross section libraries for RADSAT are updated to include ENDF/B-VII cross sections. Preliminary findings show promising results when compared to MCNP and experimental data, but also areas where additional inquiry and testing are needed. The potential benefits and shortcomings of the multi-group-based approach are discussed in terms of accuracy and computational efficiency.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarization of nuclear spins by a cold nanoscale resonator

A cold nanoscale resonator coupled to a system of nuclear spins can induce spin relaxation. In the low-temperature limit where spin-lattice interactions are ''frozen out,'' spontaneous emission by nuclear spins into a resonant mechanical mode can become the dominant mechanism for cooling the spins to thermal equilibrium with their environment. We provide a theoretical framework for the study of resonator-induced cooling of nuclear spins in this low-temperature regime. Relaxation equations are derived from first principles, in the limit where energy donated by the spins to the resonator is quickly dissipated into the cold bath that damps it. A physical interpretation of the processes contributing to spin polarization is given. For a system of spins that have identical couplings to the resonator, the interaction Hamiltonian conserves spin angular momentum, and the resonator cannot relax the spins to thermal equilibrium unless this symmetry is broken by the spin Hamiltonian. The mechanism by which such a spin system becomes ''trapped'' away from thermal equilibrium can be visualized using a semiclassical model, which shows how an indirect spin-spin interaction arises from the coupling of multiple spins to one resonator. The internal spin Hamiltonian can affect the polarization process in two ways: (1) By modifying the structure of the spin-spin correlations in the energy eigenstates, and (2) by splitting the degeneracy within a manifold of energy eigenstates, so that zero-frequency off-diagonal terms in the density matrix are converted to oscillating coherences. Shifting the frequencies of these coherences sufficiently far from zero suppresses the development of resonator-induced correlations within the manifold during polarization from a totally disordered state. Modification of the spin-spin correlations by means of either mechanism affects the strength of the fluctuating spin dipole that drives the resonator. In the case where product states can be chosen as energy eigenstates, spontaneous emission from eigenstate populations into the resonant mode can be interpreted as independent emission by individual spins, and the spins relax exponentially to thermal equilibrium if the development of resonator-induced correlations is suppressed. When the spin Hamiltonian includes a significant contribution from the homonuclear dipolar coupling, the energy eigenstates entail a correlation specific to the coupling network. Simulations of dipole-dipole coupled systems of up to five spins suggest that these systems contain weakly emitting eigenstates that can trap a fraction of the population for time periods >>100/R{sub 0}, where R{sub 0} is the rate constant for resonator-enhanced spontaneous emission by a single spin 1/2. Much of the polarization, however, relaxes with rates comparable to R{sub 0}. A distribution of characteristic high-field chemical shifts tends to increase the relaxation rates of weakly emitting states, enabling transitions to states that can quickly relax to thermal equilibrium. The theoretical framework presented in this paper is illustrated with discussions of spin polarization in the contexts of force-detected nuclear-magnetic-resonance spectroscopy and magnetic-resonance force microscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

NRC Job Code V6060: Extended In-Situ and Real Time Monitoring. Task 4: Detection and Monitoring of Leaks at Nuclear Power Plants External to Structures

In support of Task 4 of the NRC study on compliance with 10 CFR part 20.1406, minimization of contamination, Argonne National Laboratory (ANL) conducted a one-year scoping study, in concert with a parallel study performed by NRC/NRR staff, on monitoring for leaks at nuclear power plants (NPPs) external to structures. The objective of this task-4 study is to identify and assess those sensors and monitoring techniques for early detection of abnormal radioactive releases from the engineered facility structures, systems and components (SSCs) to the surrounding underground environment in existing NPPs and planned new reactors. As such, methods of interest include: (1) detection of anomalous water content of soils surrounding SSCs, (2) radionuclides contained in the leaking water, and (3) secondary signals such as temperature. ANL work scope includes mainly to (1) identify, in concert with the nuclear industry, the sensors and techniques that have most promise to detect radionuclides and/or associated chemical releases from SSCs of existing NPPs and (2) review and provide comments on the results of the NRC/NRR staff scoping study to identify candidate technologies. This report constitutes the ANL deliverable of the task-4 study. It covers a survey of sensor technologies and leak detection methods currently applied to leak monitoring at NPPs. The survey also provides a technology evaluation that identifies their strength and deficiency based on their detection speed, sensitivity, range and reliability. Emerging advanced technologies that are potentially capable of locating releases, identifying the radionuclides, and estimating their concentrations and distributions are also included in the report along with suggestions of required further research and development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sequential optimal positioning of mobile sensors using mutual information

Source localization, such as detecting a nuclear source in an urban area or ascertaining the origin of a chemical plume, is generally regarded as a well-documented inverse problem; however, optimally placing sensors to collect data for such problems is a more challenging task. In particular, optimal sensor placement—that is, measurement locations resulting in the least uncertainty in the estimated source parameters—depends on the location of the source, which is typically unknown a priori. Mobile sensors are advantageous because they have the flexibility to adapt to any given source position. While most mobile sensor strategies designate a trajectory for sensor movement, we instead employ mutual information, based on Shannon entropy, to choose the next measurement location from a discrete set of design conditions.

97 MATHEMATICS AND COMPUTING↗

Study of Te Inclusions in CdMnTe Crystals for Nuclear Detector Applications

The concentration, size and spatial distribution of Te inclusions in the bulk of CdMnTe crystals mined from two batches of ingots were studied. An isolated planar layer decorated with Te inclusions was identified in CdMnTe crystals from the second ingot. The internal electric field of a CMT crystal was probed by infrared (IR) imaging employing Pockels electro-optic effect. The effect of an isolated plane of Te inclusions on the internal electric-field distribution within the CdMnTe crystal was studied. Space charge accumulation around the plane of Te inclusions was observed, which was found to be higher when the detector was reverse-biased. The effects of the plane of Te inclusions on the electric-field distribution within the CdMnTe crystal, and the quality of CdMnTe crystals for nuclear detector applications are discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Potential impact of releases from a new Molybdenum-99 production facility on regional measurements of airborne xenon isotopes

The monitoring of the radioactive xenon isotopes 131mXe, 133Xe, 133mXe, and 135Xe is important for the detection of nuclear explosions. While backgrounds of the xenon isotopes are short-lived, they are constantly replenished from activities dominated by the fission-based production of 99Mo used for medical procedures. One of the most critical locations on earth for the monitoring of nuclear explosions is the Korean peninsula, where the Democratic Republic of North Korea (DPRK) has announced that it had conducted three nuclear tests between 2009 and 2013. This paper explores the backgrounds that would be caused by the medium to large scale production of 99Mo in the region of the Korean peninsula.

Comprehensive Nuclear-Test-Ban Treaty↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗

Hot-pressed 6 LiInSe 2 for use as a ceramic radiation detector

Lithium based chalcogenides have many uses in the nuclear science field. 6 LiInSe 2 (or LISe) has been researched extensively because of its ability to operate in both scintillator and semiconductor modes. Here, this makes it useful in applications including nuclear material detection for national security, space applications, and medical imaging. In some applications growth and fabrication costs are of concern, as it takes upwards of 40 days to synthesize a charge, grow a crystal and fabricate a detector. Ceramics are a solution for this long route of preparation. This research shows that using a 6 LiInSe 2 ceramic instead of a single crystal significantly decreases the time required to make a detector. In the present work, ceramic wafers can be formed using a mechanical press equipped with a heating attachment. The resulting ceramic wafer performs very similar to a slow-growth single crystal when used in the scintillator mode.

36 MATERIALS SCIENCE↗

Hexagonal boron nitride: Epitaxial growth and device applications

As a newest family member of the III-nitrides, BN is considered amongst the remaining frontiers in wide energy bandgap semiconductors with potentials for technologically significant applications in deep UV (DUV) optoelectronics, solid-state neutron detectors, electron emitters, single photon emitters, switching/memory devices, and super-capacitors. It was shown that it is possible to produce h-BN epilayers with high hexagonal phase purity, UV transparency, and film stoichiometry by employing nitrogen-rich growth conditions. The quasi-2D nature of h-BN supports unusually strong optical transitions near the band edge and a large exciton binding energy on the order of 0.7 eV. Since the isotope of B-10 has a large capture cross-section for thermal neutrons, h-BN is an ideal material for the fabrication of solid-state neutron detectors for special nuclear materials detection, well and geothermal logging, and medical imaging applications. Freestanding B-10 enriched h-BN (h- 10 BN) epilayers with varying thicknesses up to 200 μm have been successfully synthesized by metal organic chemical vapor deposition (MOCVD) as of this writing. By utilizing the conductivity anisotropy nature of h-BN, 1 cm 2 lateral detectors fabricated from 100 μm thick h-10BN epilayers have demonstrated a detection efficiency of 59% for thermal neutrons, which is the highest on record among all solid-state neutron detectors as of today. It was noted that high growth temperatures, long growth times and the use of sapphire substrate tend to incorporate oxygen related impurities into h- 10 BN epilayers, which strongly impacted the carrier mobility-lifetime (μτ) products and charge collection efficiencies of h- 10 BN neutron detectors. As the h-BN material technology further develops, improved carrier mobilities and μτ products will allow the fabrication of h-BN devices with enhanced performance.

42 ENGINEERING↗

An Effective Purification Process for the Nuclear Radiation Detector Tl 6 SeI 4

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6Se4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TU. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 10(11) Omega.cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV gamma-ray from Co-57 radiation source. The electron mobility-lifetime product mu(e)tau(e) for TI6SeI4 detector is 8.1 X 10(-5) cm(2).V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV alpha-particles from Am-241, the electron and hole mobilities were estimated to be 112 +/- 22 and 81 +/- 16 cm(2).V-1.s(-1), respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Lin, Wenwen (ORCID:0000000216279558)↗

Fast Neutron Dose Evaluation Using CR39 by Coincidence Counting Process

The solid state nuclear tracks detection (SSNTD) technique is widely used in the area of radiation dosimetry. Different materials can be used applying this technique as glass and the most used in the dosimetry field that are the polycarbonates, CR39 and Makrofol-DE. Both are very rich in hydrogenous, that enables the SSNTD to detect fast neutrons through recoils of protons in the own detector material, without need of converters. The low reproducibility of its backgroundhas often been the major drawback in the assessment of low fluences of fast neutrons with SSNTDs. This problem can be effectively solved by counting coincidence of tracks in two detectors foils irradiated in close contact. After processing and counting only tracks produced by the same recoil nuclei on the surfaces of both detectors are considered as a track. This procedure enables the reduction of the background counts in the response of the detectors. In this work a preliminary study on the application of the coincidence technique for neutron dosimetry is presented. The CR39 material was investigated aiming to achieve the personal dose equivalent for fast neutrons. Using this method of analysis a significant reduction on the lower detectable dose was observed resulting even one order of magnitude smaller value. Reading, however, needs to be automated due to the large areas necessary to achieve a satisfactory number of tracks for statistical significance of results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laser Plasma Accelerators for Medical and Nuclear Uses

Starting from the cases of the current clinical facilities as a source of reference to compare with, final performance of lasers and accelerators and even cost target were discussed. We assume maximum flexibility to enable treatment of small as well as large in-depth tumor volumes requiring the maximum energy of 250 MeV for protons and 400 MeV/u for carbon. We adopt their reference numbers for the required total number of protons / carbon ions per fraction (5 min) as well as peak numbers (per second). Other parameters (like energy spread and total number of voxels) are adjusted to the particularities of laser acceleration, which include a much higher production energy spread than in the synchrotron case and a laser pulse rate currently suggested by technology. As far as cost, it is assumed that a single laser driver unit is foreseen for one treatment room. It is suggested that the target for 10-20 years of development could be a cost of the laser driver unit not exceeding 1/4 of the conventional synchrotron facility cost, which is 40 MEuro. Further, design study, proposal and preliminary experimental results for all optical Compton scattering X-ray source for nuclear material detection at University of Tokyo is introduced. By using the Ti:Sapphire laser at about 7 TW and our original gas-jet and magnetic plasma channel, we succeeded in generating more than 100 MeV electrons with a reasonable emittance. Compton scattering with beam-spread Ti:Sapphire laser pulse can yield quasi-monochromatic X-rays around 110 keV near the K-edges of U, Np, Pu. Subtraction imaging across the K-edge realizes clear recognition and distingushment of those compounds in liquid.

43 PARTICLE ACCELERATORS↗

An experiment on the dynamics of ion implantation and sputtering of surfaces

A major impediment towards a better understanding of the complex plasma-surface interaction is the limited diagnostic access to the material surface while it is undergoing plasma exposure. The Dynamics of ION Implantation and Sputtering Of Surfaces (DIONISOS) experiment overcomes this limitation by uniquely combining powerful, non-perturbing ion beam analysis techniques with a steady-state helicon plasma exposure chamber, allowing for real-time, depth-resolved in situ measurements of material compositions during plasma exposure. Design solutions are described that provide compatibility between the ion beam analysis requirements in the presence of a high-intensity helicon plasma. The three primary ion beam analysis techniques, Rutherford backscattering spectroscopy, elastic recoil detection, and nuclear reaction analysis, are successfully implemented on targets during plasma exposure in DIONISOS. These techniques measure parameters of interest for plasma-material interactions such as erosion/deposition rates of materials and the concentration of plasma fuel species in the material surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Communication: Atomic force detection of single-molecule nonlinear optical vibrational spectroscopy

Atomic Force Microscopy (AFM) allows for a highly sensitive detection of spectroscopic signals. This has been first demonstrated for NMR of a single molecule and recently extended to stimulated Raman in the optical regime. We theoretically investigate the use of optical forces to detect time and frequency domain nonlinear optical signals. We show that, with proper phase matching, the AFM-detected signals closely resemble coherent heterodyne-detected signals. Applications are made to AFM-detected and heterodyne-detected vibrational resonances in Coherent Anti-Stokes Raman Spectroscopy (χ{sup (3)}) and sum or difference frequency generation (χ{sup (2)})

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact deuterium-tritium neutron generator using a novel field ionization source

Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilizing shallow color centers in diamond created by nitrogen delta-doping using SF{sub 6} plasma treatment

Here we report the fabrication of stable, shallow (<5 nm) nitrogen-vacancy (NV) centers in diamond by nitrogen delta doping at the last stage of the chemical vapor deposition growth process. The NVs are stabilized after treating the diamond in SF{sub 6} plasma, otherwise the color centers are not observed, suggesting a strong influence from the surface. X-ray photoelectron spectroscopy measurements show the presence of only fluorine atoms on the surface, in contrast to previous studies, indicating very good surface coverage. We managed to detect hydrogen nuclear magnetic resonance signal from protons in the immersion oil, revealing a depth of the NVs of about 5 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗