Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model validation and calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

579 records · Page 33

The Beam Dump eXperiment

Hadronic matter makes about 14% of the known universe. The remaining 86% is Dark Matter (DM). Since it does not interact with the ordinary matter via electromagnetic force, DM is not visible and, to date, it escaped detection. The search for Dark Matter (DM) is one of the hottest topic in modern physics. Despite the increasing number of astrophysical and cosmological observations proving the existence, so far no particle physics experiment has detected DM yet. Up to now, most of the experimental efforts have been focused on the so called WIMP (Weakly Interacting Massive Particle) paradigm, which predicts heavy DM (10 GeV-10 TeV mass range) interacting with Standard Model (SM) particles via the weak force mediators (W or Z bosons). More recently, due to the lack of clear evidence of WIMPs, other models of DM gained the interest of the physics community. These models consider Light DM particles (LDM), in MeV-GeV mass range. Among LDM theories, the Dark Photon theory predicts the existence of a Dark Sector interacting with SM particles via a new massive vector boson (Dark Photon, Heavy Photon or A0), mediator of a new force. This scenario, despite being theoretically well motivated, is remarkably experimentally unexplored. The Beam Dump eXperiment (BDX), is an approved experiment at Jefferson Lab (JLab), aiming to discover the DM predicted witihn the Dark Photon theory. The experiment uses the CEBAF (Continuous Electron Beam Accelerator Facility) 11 GeV electron beam, impinging on the JLab Hall-A beam-dump, to produce a beam of DM particles, detected by a ~ 1 m3 detector made of thallium doped cesium iodide (CsI(Tl)) crystals located ~ 20 m downstream. In order to achieve excellent background rejection, the experimental setup includes active vetos and passive shielding surrounding CsI(Tl) crystals. Given the weakness of the DM-SM interaction, the scattering of a DM particle in the BDX detector is a rare event. Therefore, the characterization of the expected background is a critical aspect of the experiment. Both cosmogenic and penetrating SM particles produced by the beam interaction in the dump contribute to the background of the experiment. While the cosmogenic contribution can be measured during the experiment when the beam is off, beam-related background can only be estimated via Monte Carlo (MC) simulations. Therefore, a careful assessment of possible systematics introduced by the MC is needed. The beam-correlated background characterization was made by measuring the muon flux produced by the interaction of the CEBAF beam with Hall-A dump in a dedicated experimental campaign in spring 2018 [1]. The comparison to the ?ux predicted by MC allowed us to validate the BDX simulation framework. The reach of BDX, i.e. the region that the experiment can probe in the LDM theory parameter space, depends critically on the background rejection capability and signal detection effciency. For this reason, the detector setup was fine-tuned through a dedicated study. The response to LDM and background events was evaluated for different setups and selection cuts. As a result of this procedure, the configuration resulting in the best sensitivity was selected [2]. The reach calculation was performed taking into account the different LDM production mechanisms, including the contribution of secondary particles produced in the beam-dump. In particular, the effect of the secondary positrons annihilation was found to be extremely significant. In the majority of the sensitivity studies, this contribution is neglected, but recent results [3] [4] demonstrated that this process significantly enhances the sensitivity of lepton beam-dump experiments. Currently, the BDX collaboration is focused on the deployment and operation of a small detector, called BDX-MINI, built to perform a preliminary physics measurement searching for LDM at JLab. This test will pave the way to the realization of the full BDX experiment. The measurement is currently ongoing but results are expected by the end of this year. During my PhD I was involved in all aspects of the BDX experiment: design, simulation, prototyping and data analysis. The main results of my work are reported in this thesis. This manuscript is organized as follows: the first Chapter provides an introduction to the theory of LDM, with particular attention to the Dark Photon paradigm; the second Chapter illustrates the BDX experimental setup, the LDM production and detection mechanisms and the expected backgrounds; Chapter 3 and 4 describe, respectively, the BDX-HODO measurement, with a detailed description of the simulations, and the BDX experimental setup and analysis cuts optimization. Chapter 5 reports about BDXMINI detector characterization, calibration and sensitivity estimate. Finally, Chapter 6 describes in detail the calculation of the secondary positron annihilation contribution to the sensitivity of BDX and other electron-beam thick-target experiment.

Marsicano, Luca↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗