Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component

A document discusses a thermal radiator design consisting of lightweight composite materials and low-emittance metal coatings for use on the James Webb Space Telescope (JWST) structure. The structure will have a Thermal Subsystem unit to provide passive cooling to the Integrated Science Instrument Module (ISIM) control electronics. The ISIM, in the JWST observatory, is the platform that provides the mounting surfaces for the instrument control electronics. Dissipating the control electronic generated-heat away from JWST is of paramount importance so that the spacecraft s own heat does not interfere with the infrared-light gathering of distant cosmic sources. The need to have lateral control in the emission direction of the IEC (ISIM Electronics Compartment) radiators led to the development of a directional baffle design that uses multiple curved mirrorlike surfaces. This concept started out from the so-called Winston non-imaging optical concentrators that use opposing parabolic reflector surfaces, where each parabola has its focus at the opposite edge of the exit aperture. For this reason they are often known as compound parabolic concentrators or CPCs. This radiator system with the circular section was chosen for the IEC reflectors because it offers two advantages over other designs. The first is that the area of the reflector strips for a given radiator area is less, which results in a lower mass baffle assembly. Secondly, the fraction of energy emitted by the radiator strips and subsequently reflected by the baffle is less. These fewer reflections reduced the amount of energy that is absorbed and eventually re-emitted, typically in a direction outside the design emission range angle. A baffle frame holds the mirrors in position above a radiator panel on the IEC. Together, these will direct the majority of the heat from the IEC above the sunshield away towards empty space.

Rashford, Robert A.↗

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil↗

Modular Soft X-Ray Emission Spectrograph

We have been developing the Hettrick-Underwood type soft x-ray spectrograph for over a decade. This optical design uses one spherical mirror for focusing x-rays onto the CCD detector and a set of variable line-spacing gratings for energy analysis. Unlike the previous effort carried out at the ALS, what we have achieved in the current design is to incorporate the concept of modularity. The model of spectrograph is shown below. It contains three major components: the optics chamber and downstream section (detector plus driving mechanism using a swing arm pivoted at the grating location, see figure) for inside and outside order (translation stage without swing arm, not shown here). Inside order design is often used when source size is larger than the detector pixel resolution, while the outside order is used when source size is smaller than the detector pixel resolution. Irrespective to which order is selected, there is no change in the mechanism of optics chamber. The location of optics chamber relative to the source and detector can also be changed to optimize the energy resolution at target photon energy. The incident angles on mirror and gratings can be varied, in conjunction with the grating line densities, to balance the resolution and throughput. The internal components of optics chamber are also modular and changing the dimension of optics can be done by using different holders. The modularity not only greatly reduces the design and assembling effort, but also offers the cost benefit. Although the cost of this type of spectrograph is expected to be higher than XES350, it is still significant lower than the one-of-the-kind design used at every synchrotron facilities. The unique flexibility and modularity not only allows the users to tailor the design of spectrograph for the characteristic of their sources, but also to have cost down in standardizing the fabrication parts.

Hussain, Zahid↗

Cryogenic Shutter Mechanism

Electromagnetic shutter mechanism operates at ambient and cryogenic temperatures to shield optical element, such as mirror, filter, polarizer, beam splitter, or detector, from external light and radiation in cryogenic Dewar equipped with window for optical evaluation. Shutter mechanism in Dewar container alternately shields and exposes optical element as paddle rotates between mechanical stops. Mounted on cold plate of liquid-helium reservoir. Paddle, shaft, and magnet constitutes assembly rotated by electromagnetic field on coil.

Barney, Richard D.↗

Development and Operations of the Astrophysics Data System

The ADS was represented at the AAS meeting with 3 poster papers and a demonstration booth. We have setup a mirror site of the Vizier data base system at the CDS. functionality of the ADC at Goddard. This will replace the Preparations for the APS and LPSC meetings in March started. We will have demonstrations at both meetings. Preparations for the APS and LPSC meetings in March continued. We will have demonstrations at both meetings. The ADS was represented with a poster at the joint AGUEGU meeting in Nice, France. Discussions about the on-going collaboration between the ADS and the CDS in Strasbourg, France were held in Strasbourg. The ADS was invited to organize a session about the ADS and its mirror sites at the next United Nations Workshop on Basic Space Sciences in the Developing World. Efforts are under way to enter the tables of contents of all conference proceedings in the SA0 library into the ADS. This requires copying the tables of contents from all volumes in the library and have them typed in. This will greatly enhance the coverage of the literature in the ADS. We started the development of a search system for the full text of all scanned material in the ADS. This will eventually allow our users search capabilities that so far do not exist in any form. I order to enable the full text searching, we have purchased OCR software and are in the process of OCRing the scanned pages in the ADS. Efforts are in progress to handle the inclusion of data set identifiers in article manuscripts. The ADS will be the central system that will allow the journals to verify data set identifiers. The "master verifier" has been implemented in prototype form at the ADS. We started to include more journals in Geosciences/Geophysics in the ADS. The Royal astronomical Society has decided to archive their on-line journals in the ADS three years after publication. We have started to process these older on-line articles in order to archive them in the ADS. Our mirror site in Korea now has a full article mirror. We developed XML output capability in the ADS. This will make it easier to exchange data with other data systems. We started the development of new indexing software that will eventually reduce the indexing time for a database from days to hours or less. The ADS was represented at the IAU General Assembly with a poster. Discussions with the IAU management were held about extending the ADS IAU collaborations.

Murray, Stephen S.↗

Imaging Unstained Synthetic Polymer Crystals and Defects on Atomic Length Scales Using Cryogenic Electron Microscopy

Properties of soft crystalline materials such as synthetic polymers are governed by locations of constituent atoms. Determining atomic-scale structures in these materials is difficult because they degrade rapidly when studied by electron microscopy, and techniques such as x-ray scattering average over volumes much larger than coherent blocks of the unit cells. We obtained cryo-electron microscopy images of self-assembled nanosheets of a peptoid polymer, made by solid-phase synthesis, in which we see a variety of crystalline motifs. A combination of crystallographic and single particle methods, developed for cryo-electron microscopy of biological macromolecules, was used to obtain high resolution images of the crystals. Individual crystals contain grains that are mirror images of each other with concomitant grain boundaries. We have used molecular dynamic simulations to build an atomic model of the crystal structure to facilitate the interpretation of electron micrographs. Direct visualization of crystalline grains and grain boundaries on atomic length scales represents a new level of information for the polymer field.

36 MATERIALS SCIENCE↗

Electrochemically in situ formed rocksalt phase in titanium dioxide determines pseudocapacitive sodium-ion storage

Earth-abundant TiO 2 is a promising negative electrode for low-cost sodium-ion batteries (SIBs) owing to its high capacity, rapid (dis)charging capability, safe operation potential and nonflammability. Crystalline anatase TiO 2 is not suitable for reversible Na + (de)intercalation, but it displays pseudocapacitive response after repeated cycles. Herein, we find and demonstrate that ordered rocksalt (RS) NaTiO 2 nanograins are in situ formed by electrochemically cycling with Na + ions in anatase and amorphous TiO 2 . The in situ formed RS-NaTiO 2 follows a solid-solution reaction with small volume changes of only 2.0%, that determines the pseudocapacitive “mirror-like” cyclic voltammetry curve with a couple of broad redox peaks at 0.75 V vs. Na + /Na, a high capacity of 253 mAh g −1 , high-rate capability and thousands of stable cycles. The multistep crystalline-to-amorphous-to-RS transformations are able to be electrochemically activated during the aging process of assembled full cells. Our finding provides a direction for developing unconventional Ti-based high-performance active materials for SIBs with both high energy and power densities.

Tang, Dafu [Xiamen University (China); Innovation ↗

Imaging Schwarzschild multilayer X-ray microscope

We have designed, analyzed, fabricated, and tested Schwarzschild multilayer X-ray microscopes. These instruments use flow-polished Zerodur mirror substrates which have been coated with multilayers optimized for maximum reflectivity at normal incidence at 135 A. They are being developed as prototypes for the Water Window Imaging X-Ray Microscope. Ultrasmooth mirror sets of hemlite grade sapphire have been fabricated and they are now being coated with multilayers to reflect soft X-rays at 38 A, within the biologically important 'water window'. In this paper, we discuss the fabrication of the microscope optics and structural components as well as the mounting of the optics and assembly of the microscopes. We also describe the optical alignment, interferometric and visible light testing of the microscopes, present interferometrically measured performance data, and provide the first results of optical imaging tests.

Hoover, Richard B.↗

Status of The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a large aperture (6.5 meter), cryogenic space telescope with a suite of near and mid-infrared instruments covering the wavelength range of 0.6 pm to 28 pm. JWST's primary science goal is to detect and characterize the first galaxies. It will also study the assembly of galaxies, star formation, and the formation of evolution of planetary systems. We will present an overview of the Observatory's current design following the Mission Preliminary Design Review, (PDR). Recent progress in hardware development for the observatory will be presented, including a discussion of the status of JWST's optical system and Beryllium mirror fabrication, progress with sunshield prototypes, and recent changes in the integration and test configuration. We also review the expected scientific performance of the observatory based on the mission PDR design.

Clampin, Mark↗

Development of Langmuir and Spatially Resolved OES Diagnostics for Arc Jet Shock and Boundary Layer Measurements Relevant to Atmospheric Re-Entry Environments

The second-generation miniature Arc Jet Research Chamber (mARC) ground testing facility at NASA Ames requires physical characterization of its supersonic plasma flow to verify numerical models and material sample testing. Two types of plasma diagnostics will be utilized: Langmuir probes and optical emission spectroscopy (OES). Several single and triple Langmuir probes have been constructed and will be inserted parallel to the flow via a sweep arm to measure post-shock electron temperature and number density along radial profiles at different axial distances. Due to the high heat flux (200-3000 W/cm2) sweep durations are necessarily short (< 0.1 s). Measuring these properties near the probe surface provide characterization of the post-shock environment. This is an important metric for validating coupled CFD-material codes, and will provide insight into longstanding thermocouple anomalies attributed to charging of heatshield surfaces. An OES system has also been assembled to obtain spatially resolved density and temperature for various flow species. The system consists of a convex lens that forms an image of the plasma onto a 16-channel linear fiber array, which will simultaneously capture the spectra from sixteen different locations. The light emission from the plasma is then focused by a spherical mirror into a spectrometer and recorded with a camera. These measurements non-intrusively provide a new spatially resolved flow characterization capability. This will initially be used to resolve issues with shock radiation interference in pyrometer measurements of material surface temperature. The design of each diagnostic and any initial results will be discussed.

Ethan Main-Loam Leong↗

HabEx Baseline Optical Telescope Assembly

The Habitable Exoplanet Observatory Mission (HabEx) will image and spectroscopically characterize planetary systems in the habitable zone around nearby sun-like stars. Additionally, HabEx will perform a broad range of general astrophysics science enabled by 100 to 2500 nm spectral range and 3 x 3 arc-minute FOV. Critical to achieving the HabEx science goals is a large, ultra-stable telescope. The baseline HabEx telescope is a 4-m off-axis unobscured three-mirror-anastigmatic design with diffraction limited performance at 400 nm and wavefront stability of picometers per mK. These specifications are driven by science requirements. STOP (structural thermal optical performance) analysis predicts that the baseline telescope’s opto-mechanical design meets its specified performance tolerances.

Stahl, H Philip↗

Distant Observer™ [SWR-12-09]

Distant Observer™ (DO) is an optical measurement tool, designed for parabolic trough solar collectors, that determines reflector slope error, absorber position error, and the combined errors based on images of the receiver-tube reflection taken from different angles. We have demonstrated that DO can provide a measurement accuracy of 0.25 mrad for the slope and receiver position errors. DO has two implementation versions: ground-based and drone-driven. As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. The Distant Observer™ (DO) tool, developed by engineers at NREL, is a fast and highly accurate tool that provides complete characterization of the performance of the optical components which include the mirror panels and thermal receiver. This tool is very useful for testing both prototype and operational modules. The Distant Observer™ is an optical measurement tool for parabolic solar collectors that measures reflector slope error, absorber position error and the combined errors. Reflector slope errors occur for many reasons including imperfection in structural frame design, manufacturing and assembly. Absorber position error can be caused by poor structural design, poor installation, sag from the absorber weight, or change in the structure over time.

Ihas, Benjamin↗

Precision engineering and optomechanics; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on precision engineering and optomechanics are presented. Individual topics addressed include: performance optimization of an IR sensor optical system, design and development of a rugged airborne scanning optical assembly for a calibrated IR imaging radiometer, numerical method for Cassegrain telescope baffle design, precision alignment of an IR imaging system, optical alignment of a pupil imaging spectrometer, optical alignment equipment and methods for visible and IR imaging meteorological radiometer. Also addressed are: vibration-design aspects of an IR-scanning earth sensor, chopping secondary mirror for the Kuiper Airborne Observatory, advanced flexure suspension systems, subminiature IR detector translation stage, thermal/optical test setup for the Geostationary Operational Environmental Satellite Telescope, design of the GOES telescope secondary mirror mounting.

Vukobratovich, Daniel↗

Software For A Laser Vibrometer

Vibration Pattern Imager (VPI) system and software designed to control and acquire data from laser vibrometer sensors. Based on personal computer, includes digital signal-processing (DSP) board and analog input/output (I/O) circuit board to control sensors and process data. Originally developed for use with Ometron VPI Sensor, adapted to any commercially available sensor that provides analog output signal and requires analog inputs for control of mirror position. VPI system includes graphical user interface providing for interactive control through keyboard and mouse-selected menu options. Main menu controls all functions for setup, acquisition of data, display, file operations, and leaving program. Two types of data acquired with system: single point or "full field". Written in C language and Texas Instrument' TMS320C30 assembly language.

Rizzi, Stephen A.↗

Superconducting magnet performance for 28 GHz electron cyclotron resonance ion source developed at the Korea Basic Science Institute

A superconducting magnet for use in an electron cyclotron resonance ion source was developed at the Korea Basic Science Institute. The superconducting magnet is comprised of three solenoids and a hexapole magnet. According to the design value, the solenoid magnets can generate a mirror field, resulting in axial magnetic fields of 3.6 T at the injection area and 2.2 T at the extraction region. A radial field strength of 2.1 T can also be achieved by hexapole magnet on the plasma chamber wall. NbTi superconducting wire was used in the winding process following appropriate techniques for magnet structure. The final assembly of the each magnet involved it being vertically inserted into the cryostat to cool down the temperature using liquid helium. The performance of each solenoid and hexapole magnet was separately verified experimentally. The construction of the superconducting coil, the entire magnet assembly for performance testing and experimental results are reported herein.

43 PARTICLE ACCELERATORS↗

Ultrahigh vacuum sample mount for x-ray photoelectron spectroscopy up to very high temperature (150-1400 K)

Spectroscopic studies are rarely performed at very high temperature, especially when combined with light from a synchrotron source. Demanding conditions of maintaining ultrahigh vacuum (UHV) during heating, together with the typically brief access to beam time at multiuser synchrotron end stations, may contribute to some of the reasons for the difficulty of such experiments. Consequently, a large number of materials with interesting properties and industrial applications at high temperature remain unexplored. The authors describe here a simple portable sample mount assembly that can be easily utilized at a beamline, with potential utility for a variety of spectroscopic measurements requiring elevated temperatures and an UHV environment. In the specific application described here, the authors use a resistive cartridge heater interfaced with a standard manipulator previously designed for cooling by liquid nitrogen with an UHV chamber and a cylindrical mirror analyzer for x-ray photoemission spectroscopy (XPS) [also known as electron spectroscopy for chemical analysis (ESCA)] at the Synchrotron Radiation Center in Stoughton, WI. The heater cartridge required only modest power to reach target temperatures using an open-loop temperature control. Finally, the authors describe the measurements of XPS (ESCA) and total-electron yield x-ray absorption spectroscopy on nanopowders and on single crystals grown by them. They emphasize the simplicity of the setup, which they believe would be of interest to groups performing measurements at large facilities, where access and time are both limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗