Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Transient of scanning electron microscopic images for a buried microstructure in insulators

We clarify the transient process and its mechanism of scanning electron microscope (SEM) images of a trench microstructure buried in insulators. First, interface charges of primary electrons trapped on the trench are derived from the charging model of a capacitor considering the electron beam induced current, and the surface potential is therefore assumed. The SEM signal current is then determined from its simplified relation with the surface potential. Calculated profiles of the secondary electron (SE) signal current and their time-evolution behaviors can well fit the transient of the experimental SEM images. Results show that the variation of the surface potential due to the transient interface charges and the effect of SE redistribution result in transients of the SEM imaging signal and the image width of the buried trench.

36 MATERIALS SCIENCE↗

Upconversion in Nd{sup 3+}-doped glasses: Microscopic theory and spectroscopic measurements

In this work, we report a systematic investigation of upconversion losses and their effects on fluorescence quantum efficiency and fractional thermal loading in Nd{sup 3+}-doped fluoride glasses. The energy transfer upconversion ({gamma}{sub up}) parameter, which describes upconversion losses, was experimentally determined using different methods: thermal lens (TL) technique and steady state luminescence (SSL) measurements. Additionally, the upconversion parameter was also obtained from energy transfer models and excited state absorption measurements. The results reveal that the microscopic treatment provided by the energy transfer models is similar to the macroscopic ones achieved from the TL and SSL measurements because similar {gamma}{sub up} parameters were obtained. Besides, the achieved results also point out the migration-assisted energy transfer according to diffusion-limited regime rather than hopping regime as responsible for the upconversion losses in Nd-doped glasses.

36 MATERIALS SCIENCE↗

Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: A kinetostatic method

Our previous study of the particle mass sensor has shown a large ratio (up to thousands) between the spring constants of a rectangular cantilever in higher mode vibration and at the static bending or natural mode vibration. This has been proven by us through the derived nodal point position equation. That solution is good for a cantilever with the free end in noncontact regime and the probe shifted from the end to an effective section and contacting a soft object. Our further research shows that the same nodal position equation with the proper frequency equations may be used for the same spring constant ratio estimation if the vibrating at higher mode cantilever's free end has a significant additional mass clamped to it or that end is in permanent contact with an elastic or hard measurand object (reference cantilever). However, in the latter case, the spring constant ratio is much smaller (in tens) than in other mentioned cases at equal higher (up to fourth) vibration modes. We also present the spring constant ratio for a vibrating at higher eigenmode V-shaped cantilever, which is now in wide use for atomic force microscopy. The received results on the spring constant ratio are in good (within a few percent) agreement with the theoretical and experimental data published by other researchers. The knowledge of a possible spring constant transformation is important for the proper calibration and use of an atomic force microscope with vibrating cantilever in the higher eigenmodes for measurement and imaging with enlarged resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser powered heating stage in a scanning electron microscope for microstructural investigations at elevated temperatures

A laser powered heating stage designed for application in high vacuum environment of a scanning electron microscope (SEM) is presented. It was developed to observe and characterize microstructural changes in crystalline materials at elevated temperatures up to 1000 deg. C. The approach utilizes the power output of a commercial infrared diode laser in order to heat up specimens without interference with the electronic system of the SEM. The heating stage can be used in combination with any standard characterization technique applicable for SEMs - electron backscatter diffraction, orientation contrast imaging, x-ray energy dispersive spectrometry, etc. The results of test measurements are presented.

36 MATERIALS SCIENCE↗

Quantum preequilibrium multistep direct calculations for nucleon scattering on deformed nuclei: a microscopic approach

An introduction of the different quantum mechanics models is given for the calculation of pre-equilibrium multistep direct process for nucleon induced reaction. A practical application is presented for {sup 238}U neutron induced reaction at medium energy (10-20 MeV). The double differential cross-sections are calculated with no adjustable parameter and reproduced the data very well. The cross-sections are expressed as a sum of DWBA transition amplitudes computed with a microscopic two-body interaction. The exited states of the target are expressed as particle-hole excitations built from single particle states obtained with the HF+BCS calculation with a Skyrme force. We also perform a sensitivity study our calculations with respect to the ingredients of the model, namely the two-body interaction which generates the transitions and the target states description.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic nature of 0{sup +} states populated in large abundance in deformed nuclei

The low-lying excited 0{sup +} states populated in large abundance in several deformed nuclei through two-nucleon transfer reaction experiments are thoroughly investigated within a microscopic multiphonon framework. The approach reproduces satisfactorily the experimental data and provides exhaustive information about the nature of those states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An integrated approach to piezoactuator positioning in high-speed atomic force microscope imaging

In this paper, an integrated approach to achieve high-speed atomic force microscope (AFM) imaging of large-size samples is proposed, which combines the enhanced inversion-based iterative control technique to drive the piezotube actuator control for lateral x-y axis positioning with the use of a dual-stage piezoactuator for vertical z-axis positioning. High-speed, large-size AFM imaging is challenging because in high-speed lateral scanning of the AFM imaging at large size, large positioning error of the AFM probe relative to the sample can be generated due to the adverse effects--the nonlinear hysteresis and the vibrational dynamics of the piezotube actuator. In addition, vertical precision positioning of the AFM probe is even more challenging (than the lateral scanning) because the desired trajectory (i.e., the sample topography profile) is unknown in general, and the probe positioning is also effected by and sensitive to the probe-sample interaction. The main contribution of this article is the development of an integrated approach that combines advanced control algorithm with an advanced hardware platform. The proposed approach is demonstrated in experiments by imaging a large-size (50 {mu}m) calibration sample at high-speed (50 Hz scan rate)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICROSCOPIC DYNAMICS AT THE GLASS TRANSITION: INSIGHTS FROM SOFT COLLOIDAL DISPERSIONS

We investigate the microscopic dynamics of compressible colloidal particles as function of concentration through dynamic light scattering and confocal microscopy experiments. In analogy with hard sphere (HS) colloidal systems, we find that the particles display liquid, supercooled liquid or glassy dynamics, depending on volume fraction. In the present case, however caging effects are observed for particle volume fractions higher than one, i.e. when the particles are compressed. We find that heterogeneous dynamics, described by a non Gaussian distribution of the displacements, play a major role in the supercooled liquid in proximity of the relaxation time.

36 MATERIALS SCIENCE↗

Graphical template software for accurate micromanipulation in a scanning electron microscope

Micromanipulation techniques in a scanning electron microscope (SEM) have been utilized for assembling micrometer-sized structures. The precision of the assembled microstructures has been limited by the poor accuracy of the SEM image. We have developed a software to assist the operator in the accurate assembly of microstructures in a SEM, in which computer-generated outlines of the target structure [graphical templates (GTs)] are superimposed on the monitor. The displayed GTs are distorted on the basis of the image properties of the SEM evaluated in advance. As a consequence, the operator can construct microstructures with a high precision only by maneuvering the manipulator so that the outline of each object perfectly overlaps the GT without any alteration of the electron optics or circuits for improving the image accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic description of the pygmy dipole resonance and its contribution to radiative capture

The radiative capture cross sections for the compound nuclei {sup 100}Sn, {sup 132}Sn and {sup 144}Nd have been calculated using both self-consistent and non-selfconsistent microscopic theories which, in addition to the standard RPA or QRPA approaches, take the single-particle continuum and phonon coupling into account. We show that the inclusion of the phonon coupling is necessary for a proper description of the pygmy resonance. Consequently, the radiative capture cross sections and corresponding rates are increased by a factor of 2-3 as compared with RPA or QRPA approaches. We conclude that the present approach provides a more complete and coherent description of the {gamma}-ray strength function than the previous models used so far and for astrophysics applications in particular, such calculations are highly recommended for a more reliable estimate of the electromagnetic properties of exotic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A metrological large range atomic force microscope with improved performance

A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z-piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x, y, and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v). Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopically Based Nuclear Energy Functionals

A major goal of the SciDAC project 'Building a Universal Nuclear Energy Density Functional' is to develop next-generation nuclear energy density functionals that give controlled extrapolations away from stability with improved performance across the mass table. One strategy is to identify missing physics in phenomenological Skyrme functionals based on our understanding of the underlying internucleon interactions and microscopic many-body theory. In this contribution, I describe ongoing efforts to use the density matrix expansion of Negele and Vautherin to incorporate missing finite-range effects from the underlying two- and three-nucleon interactions into phenomenological Skyrme functionals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A direct micropipette-based calibration method for atomic force microscope cantilevers

In this report, we describe a direct method for calibrating atomic force microscope (AFM) cantilevers with the micropipette aspiration technique (MAT). A closely fitting polystyrene bead inside a micropipette is driven by precisely controlled hydrostatic pressures to apply known loads on the sharp tip of AFM cantilevers, thus providing a calibration at the most functionally relevant position. The new method is capable of calibrating cantilevers with spring constants ranging from 0.01 to hundreds of newtons per meter. Under appropriate loading conditions, this new method yields measurement accuracy and precision both within 10%, with higher performance for softer cantilevers. Furthermore, this method may greatly enhance the accuracy and precision of calibration for colloidal probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-beam irradiation induced conductivity in ZnS nanowires as revealed by in situ transmission electron microscope

Electron transport variations in individual ZnS nanowires synthesized through a chemical vapor deposition process were in situ studied in transmission electron microscope under convergent electron-beam irradiation (EBI). It was found that the transport can dramatically be enhanced using proper irradiation conditions. The conductivity mechanism was revealed based on a detailed study of microstructure and composition evolutions under irradiation. EBI-induced Zn-rich domains' appearance and related O doping were mainly responsible for the conductivity improvements. First-principles theoretical calculations additionally indicated that the generation of midbands within a ZnS band gap might also contribute to the improved conductivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscopic theory of relaxation processes in systems of particles interacting with the hydrodynamic medium

Our work considers spatially nonuniform states of particles, weakly interacting with a hydrodynamic medium. We developed a microscopic theory, describing such systems involving Bogolubov's reduced description method. It was shown that such systems have both kinetic and hydrodynamic stages of evolution. At the kinetic stage of evolution the one-particle distribution function is a reduced description parameter for particles, and, therefore, a medium is described by five hydrodynamic parameters (density, temperature, and velocity). The coupled system of equations of motion describing the system on the kinetic stage of evolution was obtained on the basis of Bogolubov's reduced description method. The transition from the kinetic to hydrodynamic stage of evolution for particles interacting with the medium was also studied within the reduced description method. It was shown that on the hydrodynamic stage the only description parameter of particles is their density, although the medium is still described by five hydrodynamic variables. Consequently, a coupled system of equations, which completely describe the evolution of the system under consideration on the hydrodynamic stage, including dissipation processes, was obtained. These equations were used to study the propagation of acoustic waves in our system. Also the influence of particles on relaxation processes was discussed. The obtained equations, for example, may be used to describe the neutrons propagating in a hydrodynamic medium without multiplication and capture.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pygmy Resonances Within a Microscopic Multiphonon Approach

We perform HF+RPA calculations for nuclei with neutron excess in order to study the nature of the low lying dipole states. A detailed analysis shows that they are composed by many particle hole configurations in a cooperative, rather than collective, way. Nevertheless they represent a different mode as is evidenced by their transition densities. Relativistic Coulomb calculations within a microscopic multiphonon approach show that the contributions to the inelastic cross section of low lying multiphonon states is of the order of 10%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Microscopic Derivation of the Interacting Boson Model and Its Applications to Exotic Nuclei

We present a new scheme to determine the Hamiltonian of the Interacting Boson Model (IBM) microscopically, which starts from the mean-field model with Skyrme-type interactions. Surface deformations and the effects of the nuclear force are simulated in terms of bosons. By comparing Potential Energy Surface (PES) of the mean-field model with that of the IBM, the parameters of the IBM Hamiltonian can be obtained. By this method, quantum shape/phase transitions and critical-point symmetries can be reproduced. Systematic calculations on Xe and Ru isotopes shall be newly presented, which partly contain the predicted energy levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗