Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The grape cluster, metal particle 63344,1

The grape cluster metal particle 63344,1 found in lunar coarse fines is examined using the scanning electron microscope (SEM), electron microprobe, and an optical microscope. This metal particle is approximately 0.5 cm in its largest dimension and consists of hundreds of metallic globules welded together to form a structure somewhat like a bunch of grapes. Electron microprobe analysis for Fe, Ni, Co, P, and S in the metal was carried out using wavelength dispersive detectors. No primary solidification structure is observed in the globules, and the particle is slow cooled from the solidification temperature (nearly 1300 C) taking days to probably months to reach 600 C. Two mechanisms for the formation of globules are proposed. One mechanism involves the primary impact of an iron meteorite which produces a metallic liquid and vapor phase. The second mechanism involves the formation of a liquid pool of metal after impact of an iron meteorite projectile followed by a secondary impact in the liquid metal pool.

Goldstein, J. I.↗

Computer synthesis of high resolution electron micrographs

Specimen damage, spherical aberration, low contrast and noisy sensors combine to prevent direct atomic viewing in a conventional electron microscope. The paper describes two methods for obtaining ultra-high resolution in biological specimens under the electron microscope. The first method assumes the physical limits of the electron objective lens and uses a series of dark field images of biological crystals to obtain direct information on the phases of the Fourier diffraction maxima; this information is used in an appropriate computer to synthesize a large aperture lens for a 1-A resolution. The second method assumes there is sufficient amplitude scatter from images recorded in focus which can be utilized with a sensitive densitometer and computer contrast stretching to yield fine structure image details. Cancer virus characterization is discussed as an illustrative example. Numerous photographs supplement the text.

Nathan, R.↗

Ultrastructural changes in tracheal epithelial cells exposed to oxygen

White albino rats were sacrificed after 24, 36, 48, 72, and 96 h of exposure to 100% O2 at 1 atm. Tissue was prepared for the scanning electron microscope (SEM) by Critical Point Drying and for the transmission electron microscope (TEM) by plastic embedding. Scanning microscopy showed a loss of microvilli after 48 h of exposure. Cilia appeared relatively normal with SEM, but TEM revealed changes in the outer membrane. In TEM, nonciliated cells appeared swollen and often encroached on the ciliated cells. A heavy mucous blanket remained even after processing. All the changes observed that are induced by oxygen exposure contribute to mucostasis, reducing and/or halting mucociliary clearance.

Philpott, D. E.↗

Surface micro-discharges on spacecraft dielectrics

Extensive measurements on Teflon and Kapton in a scanning electron microscope indicate the existence of a well-defined family of surface micro-discharges characteristic of the dielectric material. For a given small region exposed to the 16-20 kV electron beam, the strongest discharge pulses are similar in shape and amplitude. For Teflon, typical pulse durations are 2-3 ns, rise and fall times are sometimes as low as 0.2 ns, current amplitudes are approximately 100 mA flowing down to the pedestal and the pulses are unidirectional with no ringing. The use of a rapid-scan electron microscope with a secondary-electron imaging system reveals complex charge distributions resembling Lichtenberg figures on a supposedly flat homogeneous dielectric surface. These patterns undergo extensive alteration at each micro-discharge pulse and indicate that both the charging and discharging processes are highly nonuniform over the dielectric surface. The use of floodbeam causes the occurrence of a large-scale macro-discharges, in which a typical peak current is 40 A with a duration of 120 ns.

Balmain, K. G.↗

Research directed toward improved echelles for the ultraviolet

Research was undertaken to demonstrate that improved efficiencies for low frequency gratings are obtainable with the careful application of present technology. The motivation for the study was the desire to be assured that the grating-efficiency design goals for potential Space Telescope spectrographs can be achieved. The work was organized to compare gratings made with changes in the three specific parameters: the ruling tool profile, the coating material, and the lubricants used during the ruling process. A series of coatings and test gratings were fabricated and were examined for surface smoothness with a Nomarski Differential Interference Microscope and an electron microscope. Photomicrographs were obtained to show the difference in smoothness of the various coatings and rulings. Efficiency measurements were made for those test rulings that showed good groove characteristics: smoothness, proper ruling depth, and absence of defects. The intuitive feeling that higher grating efficiency should be correlated with the degree of smoothness of both the coating and the grating is supported by the results.

Source record↗

High resolution X-ray optics for astronomical and laboratory sources

In recent years X-ray telescopes have been used successfully for high resolution observations of astronomical objects, in particular the solar corona. At the present time X-ray microscopes are being developed for diagnostics of laser and electron beam induced fusion plasmas. This paper describes both types of imaging systems using as examples the AS&E X-ray telescope on Skylab and a 10X microscope being built for Los Alamos Scientific Laboratories. The designs, manufacturing tolerances, fabrication, testing, and performance are discussed. Steps for further development in both imaging areas are identified.

Silk, J. K.↗

Solar-cell defect analyzer

Laser-Scanning System pinpoints imperfections in solar cells. Entire solar panels containing large numbers of cells can be scanned. Although technique is similar to use of scanning electron microscope (SEM) to locate microscopic imperfections, it differs in that large areas may be examined, including entire solar panels, and it is not necessary to remove cover glass or encapsulants.

Gauthier, M. K.↗

Precision scriber

Device scribes fine lines to precise tolerances on flat or round surfaces. Scriber is used in conjunction with toolmaker's microscope and will scribe metal of nonmetallic surfaces. When not in use, scriber is easily retracted or swung out of way so microscope can be used for other purposes.

Buzzard, R. J.↗

Automated clinical system for chromosome analysis

An automatic chromosome analysis system is provided wherein a suitably prepared slide with chromosome spreads thereon is placed on the stage of an automated microscope. The automated microscope stage is computer operated to move the slide to enable detection of chromosome spreads on the slide. The X and Y location of each chromosome spread that is detected is stored. The computer measures the chromosomes in a spread, classifies them by group or by type and also prepares a digital karyotype image. The computer system can also prepare a patient report summarizing the result of the analysis and listing suspected abnormalities.

Castleman, K. R.↗

Lubrication and failure mechanisms of molybdenum disulfide films. 1: Effect of atmosphere

Friction, wear, and wear lives of rubbed molybdenum disulfide (MoS2 films applied to sanded 440C HT steel surfaces were evaluated in moist air, dry air, and dry argon. Optical microscope observations were made as a function of sliding distance to determine the effect of moisture and oxygen on the lubricating and failure mechanisms of MoS2 films. In general, the lubrication process consisted of the formation of a thin, metallic colored, coalesced film of MoS2 that flowed between the surfaces in relative motion. In air, failure was due to the transformation of the metallic colored, coalesced films to a black, powdery material. Water in the air appeared to accelerate the transformation rate. In argon, no transformation of MoS2 was observed with the microscope, but cracking and spalling of the coalesced film occurred and resulted in the gradual depletion of the film.

Fusaro, R. L.↗

Ice crystal growth in a dynamic thermal diffusion chamber

Ice crystals were grown in a supersaturated environment produced by a dynamic thermal diffusion chamber, which employed two horizontal plates separated by a distance of 2.5 cm. Air was circulated between and along the 1.2 m length of the plates past ice crystals which nucleated and grew from a fiber suspended vertically between the two plates. A zoom stereo microscope with a magnification which ranged from 3X to 80X and both 35 mm still photographs and 16 mm time lapse cine films taken through the microscope were used to study the variation of the shape and linear growth rate of ice crystals as a function of the ambient temperature, the ambient supersaturation, and the forced ventilation velocity. The ambient growth conditions were varied over the range of temperature 0 to -40 C, over the range of supersaturation 4% to 50% with respect to ice, and over the range of forced ventilation velocities 0 cm/s to 20 cm/s.

Keller, V. W.↗

The free-electron laser - Maxwell's equations driven by single-particle currents

It is shown that if single particle currents are coupled to Maxwell's equations, the resulting set of self-consistent nonlinear equations describes the evolution of the electron beam and the amplitude and phase of the free-electron-laser field. The formulation is based on the slowly varying amplitude and phase approximation, and the distinction between microscopic and macroscopic scales, which distinguishes the microscopic bunching from the macroscopic pulse propagation. The capabilities of this new theoretical approach become apparent when its predictions for the ultrashort pulse free-electron laser are compared to experimental data; the optical pulse evolution, determined simply and accurately, agrees well with observations.

Colson, W. B.↗

Microcrack closure in rocks under stress - Direct observation

Direct observations of the closure of microcracks in rocks under increasing stress are reported. Uniaxial stresses up to 300 bars were applied to untreated and previously heated samples of Westerly granite and Frederick diabase by a small hydraulic press which fit entirely within a scanning electron microscope. Crack closure characteristics are found to depend on crack orientation, with cracks perpendicular to the applied stress closing and those parallel tending to open, as well as crack aspect ratio, crack intersection properties, stress concentrations and surface roughness. Uniaxial and hydrostatic stress measurements are found to be strongly dependent on fracture content as observed by SEM, and the observed hysteresis in strain measurements in the first stress cycles is also related to microscopic processes

Batzle, M. L.↗

Characteristics of rain and rain systems

The description and measurement of the macroscopic and microscopic characteristics of rain and rain systems are discussed. The statistical relationships of these characteristics and their effect on polarization and attenuation are considered. Macroscopic characteristics include the size, distribution, and movements of rain cells, the height of melting layers, and the presence of ice crystals. Microscopic characteristics include the size distribution, density, and oblateness of rain drops and ice crystals. The estimation of a major propagation effect, specific attenuation, is described.

Source record↗

A description of the UK Meteorological Office CCN counter

The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.

Kitchen, M.↗

Analysis of infrared emission from thin adsorbates

Fuel and lubricant deposits on solid surfaces, though often of similar visual appearance, differ in composition, depending on the nature of the deposit formers and the circumstances of deposition. To help establish these relations an Infrared Emission Fourier Polarization Microspectrophotometer was constructed to record infrared spectra from the deposits on their original support. By focussing on small aggregates with a reflecting microscope objective and by discriminating against the randomly polarized blackbody radiation with a rotating polarizing filter phase-locked to an amplifier, excellent Fourier emission spectra of polarized bands could be obtained. In many instances, the microscope objective was adequate without the polarizer. The analysis was calibrated against a very thin film of polyethylene terephthalate attached to a highly reflective aluminum mirror on the sample positioner.

Lauer, J. L.↗

Imaging antenna arrays

Many millimeter and far-infrared imaging systems are limited in sensitivity and speed because they depend on a single scanned element. Because of recent advances in planar detectors such as Schottky diodes, superconducting tunnel junctions, and microbolometers, an attractive approach to this problem is a planar antenna array with integrated detectors. A planar line antenna array and optical system for imaging has been developed. The significant advances are a 'reverse-microscope' optical configuration and a modified bow-tie antenna design. In the 'reverse-microscope' configuration, a lens is attached to the bottom of the substrate containing the antennas. Imaging is done through the substrate. This configuration eliminates the troublesome effects of substrate surface waves. The substrate lens has only a single refracting surface, making possible a virtually aplanatic system, with little spherical aberration or coma. The array is characterized by an optical transfer function that is easily measured. An array with 19 dB crosstalk levels between adjacent antennas has been tested and it was found that the array captured 50 percent of the available power. This imaging system was diffraction limited.

Rutledge, D. B.↗

Evaluation of electrode shape and nondestructive evaluation method for welded solar cell interconnects

Resistance welds of solar cell interconnect tabs were evaluated. Both copper-silver and silver-silver welds were made with various heat inputs and weld durations. Parallel gap and annular gap weld electrode designs were used. The welds were analyzed by light microscope, electron microprobe and scanning laser acoustic microscope. These analyses showed the size and shape of the weld, the relationship between the acoustic micrographs, the visible electrode footprint, and the effect of electrode misalignment. The effect of weld heat input on weld microstructure was also shown.

Baraona, C. R.↗