Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Rate constants for OH with selected large alkanes : shock-tube measurements and an improved group scheme.

High-temperature rate constant experiments on OH with the five large (C{sub 5}-C{sub 8}) saturated hydrocarbons n-heptane, 2,2,3,3-tetramethylbutane (2,2,3,3-TMB), n-pentane, n-hexane, and 2,3-dimethylbutane (2,3-DMB) were performed with the reflected-shock-tube technique using multipass absorption spectrometric detection of OH radicals at 308 nm. Single-point determinations at {approx}1200 K on n-heptane, 2,2,3,3-TMB, n-hexane, and 2,3-DMB were previously reported by Cohen and co-workers; however, the present work substantially extends the database to both lower and higher temperature. The present experiments span a wide temperature range, 789-1308 K, and represent the first direct measurements of rate constants at T > 800 K for n-pentane. The present work utilized 48 optical passes corresponding to a total path length of {approx}4.2 m. As a result of this increased path length, the high OH concentration detection sensitivity permitted pseudo-first-order analyses for unambiguously measuring rate constants. The experimental results can be expressed in Arrhenius form in units of cm{sup 3} molecule{sup -1} s{sup -1} as follows: K{sub OH+n-heptane} = (2.48 {+-} 0.17) x 10{sup -10} exp[(-1927 {+-} 69 K)/T] (838-1287 K); k{sub OH+2,2,3,3-TMB} = (8.26 {+-} 0.89) x 10{sup -11} exp[(-1337 {+-} 94 K)/T] (789-1061 K); K{sub OH+n-pentane} = (1.60 {+-} 0.25) x 10{sup -10} exp[(-1903 {+-} 146 K)/T] (823-1308 K); K{sub OH+n-hexane} = (2.79 {+-} 0.39) x 10{sup -10} exp[(-2301 {+-} 134 K)/T] (798-1299 K); and k{sub OH+2,3-DMB} = (1.27 {+-} 0.16) x 10{sup -10} exp[(-1617 {+-} 118 K)/T] (843-1292 K). The available experimental data, along with lower-T determinations, were used to obtain evaluations of the experimental rate constants over the temperature range from {approx}230 to 1300 K for most of the title reactions. These extended-temperature-range evaluations, given as three-parameter fits, are as follows: k{sub OH+n-heptane} = 2.059 x 10{sup -5}T{sup 1.401} exp(33 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (241-1287 K); k{sub OH+2,2,3,3-TMB} = 6.835 x 10{sup -17}T{sup 1.886} exp(-365 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (290-1180 K); k{sub OH+n-pentane} = 2.495 x 10{sup -16}T{sup 1.649} exp(80 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (224-1308 K); k{sub OH+n-hexane} = 3.959 x 10{sup -18}T{sup 2.218} exp(443 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (292-1299 K); and k{sub OH+2,3-DMB} = 2.287 x 10{sup -17}T{sup 1.958} exp(365 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (220-1292 K). The experimental data and the evaluations obtained for these five larger alkanes in the present work were used along with prior data/evaluations obtained in this laboratory for H abstractions by OH from a series of smaller alkanes (C{sub 3}?C{sub 5}) to devise rate rules for abstractions from various types of primary, secondary, and tertiary H atoms. Specifically, the current scheme was applied with good success to H abstractions by OH from a series of n-alkanes (n-octane through n-hexadecane). The total rate constants using this group scheme for reactions of OH with selected large alkanes are given as three-parameter fits in this article. The rate constants for the various abstraction channels in any large n-alkane can also be obtained using the groups listed in this article. The present group scheme serves to reduce the uncertainties in rate constants for OH + alkane reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft x-ray measurements using photoconductive type-IIa and single-crystal chemical vapor deposited diamond detectors

Photoconductive detectors (PCDs) are routinely used alongside vacuum x-ray diodes (XRDs) to provide an alternative x-ray flux measurement at laser facilities such as HELEN at AWE Aldermaston, UK, and Omega at the Laboratory for Laser Energetics. To evaluate diamond PCDs as an alternative to XRD arrays, calibration measurements made at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory are used to accurately calculate the x-ray flux from a laser-heated target. This is compared to a flux measurement using the Dante XRD diagnostic. Estimates indicate that the photoinduced conductivity from measurements made at Omega are too large, and calculations using the radiometric calibrations made at the NSLS agree with this hypothesis. High-purity, single-crystal, chemical vapor deposited (CVD) diamond samples are compared to natural type-IIa PCDs and show promising high resistivity effects, the corollary of which preliminary results show is a slower response time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New measurements of the EMC Effect in Light Nuclei and at Large x

While the modification of structure functions in nuclei (the EMC Effect) has been the focus of intense experimental and theoretical study since the original discovery in 1983, the experimental emphasis has been on heavy or mediumheavy nuclei. The theoretical interpretation of the EMC Effect is far from clear; it remains difficult to disentangle the "conventional" nuclear physics effects of binding and Fermi motion from more exotic effects. The study of the EMC Effect in light nuclei, where the detailed nuclear structure is well understood, and at large x, where effects from Fermi motion dominate, will add new insight into the underlying mechanism at work. Experiment E03103 at Jefferson Lab measured electron scattering cross sections from nuclei (A=3 to 197) and the deuteron to provide new data on the EMC Effect. These measurements will greatly improve the precision of the existing data set on 4He, provide the first measurement of the EMC Effect in 3He for x>0.5, a

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Precision Measurement Of The Neutral Pion Lifetime: The PRIMEX Experiment

The PRIMEX collaboration at Jefferson Lab is completing an experimental analysis to obtain a precision measurement of the neutral pion lifetime. Results from the experiment will be presented and comparisons made with the chiral anomaly prediction and NLO calculations. An extension of the experiment to 12 GeV for measurements of the {eta} and {eta}' radiative widths is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton Form Factor Measurements Using Polarization Method: Beyond Born Approximation

Significant theoretical and experimental efforts have been made over the past 7 years aiming to explain the discrepancy between the proton form factor ratio data obtained at JLab using the polarization method and the previous Rosenbluth measurements. Preliminary results from the first high precision polarization experiment dedicated to study effects beyond Born approximation will be presented. The ratio of the transferred polarization components and, separately, the longitudinal polarization in ep elastic scattering have been measured at a fixed Q{sup 2} of 2.5 GeV{sup 2} over a wide kinematic range. The two quantities impose constraints on the real part of the ep elastic amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-Spin Asymmetry Measurement at CLAS

Beam Single Spin Asymmetries in single neutral semi-inclusive pion electroproduction off an unpolarized hydrogen target in the deep inelastic scattering regime (Q{sup 2}>1 GeV{sup 2}, W{sup 2}>4 GeV{sup 2}) have been measured using a polarized electron beam of 5.776 GeV with the CEBAF Large Acceptance Spectrometer at the Thomas Jefferson National Accelerator Facility (JLab). The measured kinematical dependences are compared with published data and existing theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New measurements of the EMC effect in light nuclei

Modifications of structure functions in nuclei (EMC effect) suggest that the nuclear quark distribution function is not just the incoherent sum of the proton and neutron distributions, and made clear the importance of nuclear effects even in high energy measurements. Jefferson Lab experiment E03-103 made precise measurements of the EMC effect in few-body and heavy nuclei with emphasis on the large x region. Data from the light nuclei suggests that the nuclear dependence of the high x quark distribution may depend on the nucleon's local environment, rather than being a purely bulk effect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty analysis technique for OMEGA Dante measurements

The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions

A high density Langmuir probe array has been developed for measurements of scrape-off layer parameters in NSTX. Relevant scale lengths for heat and particle fluxes are 1-5 cm. Transient edge plasma events can occur on a time scale of several milliseconds, and the duration of a typical plasma discharge is {approx}1 s. The array consists of 99 individual electrodes arranged in three parallel radial rows to allow both swept and triple-probe operation and is mounted in a carbon tile located in the lower outer divertor of NSTX between two segments of the newly installed liquid lithium divertor. Initial swept probe results tracking the outer strike point through probe flux measurements are presented.

36 MATERIALS SCIENCE↗

A synchronized emissive probe for time-resolved plasma potential measurements of pulsed discharges

A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals

The elliptically curved pentaerythritol (PET) crystals used in the Supersnout 2 x-ray spectrometer on the National Ignition Facility at Lawrence Livermore National Laboratory have been calibrated photometrically in the range of 5.5-16 keV. The elliptical geometry provides broad spectral coverage and minimizes the degradation of spectral resolution due to the finite source size. The reflectivity curve of the crystals was measured using a x-ray line source. The integrated reflectivity (R{sub I}) and width of its curve ({Delta}{Theta}) were the measurements of major interest. The former gives the spectrometer throughput, and the latter gives the spectrometer resolving power. Both parameters are found to vary considerably with the radius of curvature of the crystal and with spectral energy. The results are attributed to an enhanced mosaic effect due to the increase in curvature. There are also contributions from the crystal cleaving and gluing processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A shallow underground laboratory for low-background radiation measurements and materials development

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision measurement of the proton charge radius: The PRad experiment

The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 ± 0.0007 fm was extracted which is 7σ smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these 'electronic' determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved at Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup −4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗