Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Clip-On Extensometer

Flexural clamp eliminates problems of operator variability. Extensometer opens and closes like clothespin and placed easily on specimen. Dimensions of block specimen are 1 by 1 by 2.2 inches (2.54 by 2.54 by 5.59 centimeters). By constructing central flexure units of various widths, one adapts extensometer to handle specimens ranging from thin strips to those many inches thick. New design reduces measurement errors caused by variability among test operators.

Holmes, A. M. C.↗

Crop area estimation based on remotely-sensed data with an accurate but costly subsample

Research activities conducted under the auspices of National Aeronautics and Space Administration Cooperative Agreement NCC 9-9 are discussed. During this contract period research efforts are concentrated in two primary areas. The first are is an investigation of the use of measurement error models as alternatives to least squares regression estimators of crop production or timber biomass. The secondary primary area of investigation is on the estimation of the mixing proportion of two-component mixture models. This report lists publications, technical reports, submitted manuscripts, and oral presentation generated by these research efforts. Possible areas of future research are mentioned.

Gunst, R. F.↗

The structure of separated flow regions occurring near the leading edge of airfoils including transition

A semi-empirical method for predicting separation bubble characteristics was evaluated using low Reynolds number test data. On the basis of this data, several observations were made. First, a sizable growth in the momentum thickness can occur in the laminar portion of a separation bubble. This is in direct contrast to the theory and is apparently due to low Reynolds number effects. Secondly, the transition Reynolds number (R sub l sub 1) which governs the extent of a bubble's laminar region, was found to be much lower than that used in the method. At present, there does not seem to be any evidence supporting a single value for R sub l sub 1. Apparently, R sub l sub 1 is affected by the freestream disturbance environment, and airfoil's pressure distribution, and possibly the chord Reynolds number as well. Thirdly, the growth in momentum thickness over a bubble's turbulent region was predicted reasonably well by the method, provided that Roberts' suggested value for the mean dissipation coefficient was used. Finally, the present data does not substantiate the universality of the velocity profile at reattachment. However, measurement error may be responsible for this result.

Mueller, T. J.↗

Verification of static rotor-load measurement capabilities of the RSRA helicopter active-isolator system

The Rotor Systems Research Aircraft helicopter technology demonstration test bed incorporates an active isolator system which reduces the rotor vibrations that are transmitted to the airframe and allows the simultaneous measurement of all six forces and moments generated by the rotor. The first full system calibration was performed in 1983 to verify the system's static load measurement capabilities; the analysis of the data encompassed multiple linear regressions to determine calibration matrices for different data sets, and a hysteresis removal algorithm for the estimation of in-flight measurement errors. The results obtained indicate that the active isolator system meets most performance predictions.

Acree, C. W., Jr.↗

Accuracy of wind measurements using an airborne Doppler lidar

Simulated wind fields and lidar data are used to evaluate two sources of airborne wind measurement error. The system is sensitive to ground speed and track angle errors, with accuracy required of the angle to within 0.2 degrees and of the speed to within 1 knot, if the recovered wind field is to be within five percent of the correct direction and 10 percent of the correct speed. It is found that errors in recovered wind speed and direction are dependent on wind direction relative to the flight path. Recovery of accurate wind fields from nonsimultaneous sampling errors requires that the lidar data be displaced to account for advection so that the intersections are defined by air parcels rather than fixed points in space.

Carroll, J. J.↗

Tracking Landsat-5 by a differential GPS technique

As part of an international campaign to develop precise geodetic applications of the Global Positioning System (GPS), the Jet Propulsion Laboratory is conducting a demonstration of differential GPS tracking using Landsat-5. Two strategies have been investigated: one in which only the Landsat-5 orbit is estimated, and one in which both the Landsat-5 and GPS orbits are estimated together. Error studies show that under the limited conditions of the experiment, three-dimensional Landsat-5 position accuracies of about 5 m with the first strategy and 2 m with the second strategy can be achieved over a 20-min period of good observing geometry. Orbit determination results using a version of the first strategy appear to achieve the 5 m goal. This is supported by various formal error measures and independent comparisons. The more powerful strategy has yet to be carried out.

Yunck, T. P.↗

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

Influence of Rayleigh-Doppler broadening on the selection of H2O dial system parameters

Computer simulations have enabled the performance of a H2O Differential Absorption Lidar (DIAL) system to be studied by spectrally analyzing the forward propagating and backscattered laser energy. The simulations were done for a high altitude (21 km) DIAL system operating in a nadir-viewing mode. The influence of Rayleigh Doppler broadening on DIAL measurement accuracies were evaluated and show that the Rayleigh broadening influence, which can be corrected to first order in regions free of large aerosol gradients, reduces the sensitivity of DIAL H2O measurement errors in the upper tropospheric region. The ability to correct the Rayleigh broadening and the selection of H2O DIAL parameters when all the systematic effects are combined, were discussed.

Ismail, S.↗

DYCAST: A finite element program for the crash analysis of structures

DYCAST is a nonlinear structural dynamic finite element computer code developed for crash simulation. The element library contains stringers, beams, membrane skin triangles, plate bending triangles and spring elements. Changing stiffnesses in the structure are accounted for by plasticity and very large deflections. Material nonlinearities are accommodated by one of three options: elastic-perfectly plastic, elastic-linear hardening plastic, or elastic-nonlinear hardening plastic of the Ramberg-Osgood type. Geometric nonlinearities are handled in an updated Lagrangian formulation by reforming the structure into its deformed shape after small time increments while accumulating deformations, strains, and forces. The nonlinearities due to combined loadings are maintained, and stiffness variation due to structural failures are computed. Numerical time integrators available are fixed-step central difference, modified Adams, Newmark-beta, and Wilson-theta. The last three have a variable time step capability, which is controlled internally by a solution convergence error measure. Other features include: multiple time-load history tables to subject the structure to time dependent loading; gravity loading; initial pitch, roll, yaw, and translation of the structural model with respect to the global system; a bandwidth optimizer as a pre-processor; and deformed plots and graphics as post-processors.

Pifko, A. B.↗

Cloud-top meridional momentum transports on Saturn and Jupiter

Cloud-tracked wind measurements reported by Sromovsky et al. were analyzed to determine meridional momentum transports in Saturn's northern middle latitudes. Results are expressed in terms of eastward and northward velocity components (u and v), and eddy components u and v. At most latitudes between 13 and 44 deg N (planetocentric), the transport by the mean flow ( ) is measurably southward, tending to support Saturn's large equatorial jet, and completely dominating the eddy transport. Meridional velocities are near zero at the peak of the relatively weak westward jet; along the flanks of that jet, measurements indicate divergent flow out of the jet. In this region the dominant eddy transport ( ) is northward on the north side of the jet, but not resolvable on the south side. Eddy transports at most other latitudes are not significantly different from measurement error. The conversion of eddy kinetic energy to mean kinetic energy, indicated by the correlation between and d /dy (where y is meridional distance) is clearly smaller than various values reported for Jupiter, and not significantly different from zero. Both Jovian and Saturnian results may be biased by the tendency for cloud tracking to favor high contrast features, and thus may not be entirely representative of the cloud level motions as a whole.

Stromovsky, L. A.↗

A comprehensive estimate of the static aerodynamic forces and moments of the 8 x 8 x 20 ft. cargo container

A comprehensive static aerodynamic simulation model of the 8 by 8 by 20 ft MILVAN cargo container is determined by combining the wind tunnel data from a 1972 NASA Ames Research Center study taken over the restricted domain (0 is less than or equal to phi is less than or equal to 90 degrees; 0 is less than or equal to alpha is less than or equal to 45 degrees) with extrapolation relations derived from the geometric symmetry of rectangular boxes. It is found that the aerodynamics of any attitude can be defined from the aerodynamics at an equivalent attitude in the restricted domain (0 is less than phi is less than 45 degrees; 0 is less than alpha is less than 90 degrees). However, a similar comprehensive equivalence with the domain spanned by the data is not available; in particular, about two-thirds of the domain with the absolute value of alpha is greater than 45 degrees is unrelated to the data. Nevertheless, as estimate can be defined for this region consistent with the measured or theoretical values along its boundaries and the theoretical equivalence of points within the region. These descrepancies are assumed to be due to measurement errors. Data from independent wind tunnel studies are reviewed; these are less comprehensive than the NASA Ames Research Center but show good to fair agreement with both the theory and the estimate given here.

Cicolani, Luigi↗

Static calibration of the RSRA active-isolator rotor balance system

The Rotor Systems Research Aircraft (RSRA) active-isolator system is designed to reduce rotor vibrations transmitted to the airframe and to simultaneously measure all six forces and moments generated by the rotor. These loads are measured by using a combination of load cells, strain gages, and hydropneumatic active isolators with built-in pressure gages. The first static calibration of the complete active-isolator rotor balance system was performed in l983 to verify its load-measurement capabilities. Analysis of the data included the use of multiple linear regressions to determine calibration matrices for different data sets and a hysteresis-removal algorithm to estimate in-flight measurement errors. Results showed that the active-isolator system can fulfill most performance predictions. The results also suggested several possible improvements to the system.

Acree, C. W., Jr.↗

Optical strain measurement system development

A laser speckle, differential strain measurement system has been built and tested for future applications in hostile environments. One-dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system has been used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement error is estimated to be +/-18 microstrain +/-3 percent of the strain reading. The upper temperature limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

Modeling Pluto-Charon mutual eclipse events. I - First-order models

The present 'first order' analytical and numerical models of light curves due to mutual events between close planetary binaries, the effects of shadowing are included. Attention is given to the case of the Pluto-Charon system. The results of the analytical and numerical approaches agree to well within the expected light curve measurement error. The model predicts that the current mutual eclipse event series will end by November 1990.

Dunbar, R. Scott↗

Fast-response, high-precision carbon monoxide sensor using a tunable diode laser absorption technique

A tunable diode laser instrument, denoted as DACOM (Differential Absorption CO Measurement), has been developed to meet the fast-response, high-precision CO measurement needs of the GTE (Global Tropospheric Experiment) program. Under the GTE program, DACOM participated in the three field missions of CITE 1 (Chemical Instrumentation Test and Evaluation 1), a project involving the intercomparison of trace gas measurement techniques. DACOM performance, including analyses of measurement error sources, is discussed for the ground-based mission at Wallops Island, VA (summer 1983), and two missions on the NASA CV-990 (fall 1983 and spring 1984). Examples of fast-response (about 1 s), high-precision (+ or - 1 part per billion by volume, + or - 1.5 percent of reading) airborne data are included to illustrate the capability of this instrument.

Sachse, Glen W.↗

The effect of the dynamic wet troposphere on radio interferometric measurements

A statistical model of water vapor fluctuations is used to describe the effect of the dynamic wet troposphere on radio interferometric measurements. It is assumed that the spatial structure of refractivity is approximated by Kolmogorov turbulence theory, and that the temporal fluctuations are caused by spatial patterns moved over a site by the wind, and these assumptions are examined for the VLBI delay and delay rate observables. The results suggest that the delay rate measurement error is usually dominated by water vapor fluctuations, and water vapor induced VLBI parameter errors and correlations are determined as a function of the delay observable errors. A method is proposed for including the water vapor fluctuations in the parameter estimation method to obtain improved parameter estimates and parameter covariances.

Treuhaft, R. N.↗

Fine-scale motion in the central Orion nebula

The inner region of M42 has been mapped in the O III N1 forbidden line at an unprecedented combination of velocity and spatial resolution and photometric accuracy. Three separate velocity systems along the line of sight are identified. Differential mass flow is present in two of these systems. All three systems show random fluctuations in velocity well above their measurement errors. The point-by-point velocities are used to determine the diagnostic statistical parameter, the structure function. The random motions show correlation with spatial separation, as expected for turbulence; but comparison with the predictions of classical theory for nebular turbulence shows poor agreement. If Kolmogorov (1941, 1942) theory applies, then the energy must be input at many scales.

Castaneda, Hector O.↗

A systematic search for long-term variability in a large sample of X-ray sources

A method which uses the correct measurement error distribution (Poisson) and which naturally takes into account detections as well as upper limits has been developed to search for flux variability in X-ray sources. The method is applied to 256 sources observed at least twice with the Einstein Observatory Imaging Proportional Counter. These sources have, in the very large majority of cases, an X-ray flux in the range 1 x 10 to the -13th to 6 x 10 to the -12th erg/sq cm/s (0.2-3.5 keV). Thirty-one sources show flux variations with amplitude ranging from about 20 percent to a factor of 6. Flux variations of small amplitude seem to be fairly common, but can be detected only in bright sources or in sources observed with very long exposures. Variations of a factor of 2 or more are seen in about 15 percent of the sources for which variations of such an amplitude are detectable.

Maccacaro, Tommaso↗