Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Bipolar Blobs as Evidence of Hidden AGN Activities in the Low-mass Galaxies

Abstract We report evidence of a hidden black hole (BH) in a low-mass galaxy, MaNGA 9885-9102, and provide a new method to identify active BHs in low-mass galaxies. This galaxy is originally selected from the MaNGA survey with distinctive bipolar Hαblobs at the minor axis. The bipolar feature can be associated with active galactic nuclei (AGN) activity, while the two blobs are classified as the Hiiregions on the BPT diagram, making the origins confusing. The Swift UV continuum shows that the two blobs do not have UV counterparts, suggesting that the source of ionization is out of the blobs. Consistent with this, the detailed photoionization models prefer AGN rather than the star-forming origin with a significance of 5.8σ. The estimated BH mass isM BH ∼ 7.2 × 10 5 M ⊙ from theM BH –σ * relationship. This work introduces a novel method for detecting the light echo of BHs, potentially extending to intermediate mass, in low-metallicity environments where the traditional BPT diagram fails.

Astronomy & Astrophysics↗

Di-nucleons do not form bound states at heavy pion mass

We perform a high-statistics lattice QCD calculation of the low-energy two-nucleon scattering amplitudes. In order to address discrepancies in the literature, the calculation is performed at a heavy pion mass in the limit that the light quark masses are equal to the physical strange quark mass, $m_π= m_K \simeq 714 $ MeV. Using a state-of-the-art momentum space method, we rule out the presence of a bound di-nucleon in both the isospin 0 (deuteron) and 1 (di-neutron) channels, in contrast with many previous results that made use of compact hexaquark creation operators. In order to diagnose the discrepancy, we add such hexaquark interpolating operators to our basis and find that they do not affect the determination of the two-nucleon finite volume spectrum, and thus they do not couple to deeply bound di-nucleons that are missed by the momentum-space operators. Further, we perform a high-statistics calculation of the HAL QCD potential on the same gauge ensembles and find qualitative agreement with our main results. We conclude that two-nucleons do not form bound states at heavy pion masses and that previous identification of deeply bound di-nucleons must have arisen from a misidentification of the spectrum from off-diagonal elements of a correlation function.

FOS: Physical sciences↗

Implications of reduced-complexity aerosol thermodynamics on organic aerosol mass concentration and composition over North America

Atmospheric organic aerosol (OA) mass concentrations can be affected by water uptake through its impact on the gas–particle partitioning of semi-volatile compounds. Current chemical transport models (CTMs) neglect this process. We have implemented the Binary Activity Thermodynamics model coupled to a volatility basis set partitioning scheme in the GEOS-Chem CTM, providing an efficient reduced-complexity OA model that predicts relative-humidity-dependent mixing and partitioning thermodynamics, while limiting the impact on computational efficiency. We provide a quantitative assessment of this water-sensitive OA treatment, focusing on a subdomain over North America. The updated OA scheme predicts a spatiotemporal mean enhancement in surface-level OA mass concentration of 145 % for January 2019 and 76 % for July 2019 compared to GEOS-Chem's most advanced OA scheme. The temporal mean surface-level OA organic mass concentration can increase by up to ∼590 % for January 2019 and ∼280 % for July 2019, with the greatest enhancements occurring over the ocean. The updated OA scheme also quantifies the OA-associated water content. The simulations show how different OA precursors and related OA surrogates contribute and respond to water uptake, including that due to changes in temperature and relative humidity over the diurnal cycle in selected winter and summer months. These results are independent of future CTM improvements involving updates to chemical reaction schemes and emission inventories. Our water-sensitive OA scheme allows for a better representation of the seasonal and regional variations in OA mass concentration in CTMs.

54 ENVIRONMENTAL SCIENCES↗

A differential emissivity imaging technique for measuring hydrometeor mass and type

Abstract. The Differential Emissivity Imaging Disdrometer (DEID) is a new evaporation-based optical and thermal instrument designed to measure the mass, size, density and type of individual hydrometeors as well as their bulk properties. Hydrometeor spatial dimensions are measured on a heated metal plate using an infrared camera by exploiting the much higher thermal emissivity of water compared with metal. As a melted hydrometeor evaporates, its mass can be directly related to the loss of heat from the hotplate assuming energy conservation across the hydrometeor. The heat loss required to evaporate a hydrometeor is found to be independent of environmental conditions including ambient wind velocity, moisture level and temperature. The difference in heat loss for snow vs. rain for a given mass offers a method for discriminating precipitation phase. The DEID measures hydrometeors at sampling frequencies of up to 1 Hz with masses and effective diameters greater than 1 µg and 200 µm, respectively, determined by the size of the hotplate and the thermal camera specifications. Measurable snow water equivalent (SWE) precipitation rates range from 0.001 to 200 mm h−1, as validated against a standard weighing bucket. Preliminary field experiment measurements of snow and rain from the winters of 2019 and 2020 provided continuous automated measurements of precipitation rate, snow density and visibility. Measured hydrometeor size distributions agree well with canonical results described in the literature.

47 OTHER INSTRUMENTATION↗

An evaluation of multi-fidelity methods for quantifying uncertainty in projections of ice-sheet mass change

Abstract. This study investigated the computational benefits of using multi-fidelity statistical estimation (MFSE) algorithms to quantify uncertainty in the mass change of Humboldt Glacier, Greenland, between 2007 and 2100 using a single climate change scenario. The goal of this study was to determine whether MFSE can use multiple models of varying cost and accuracy to reduce the computational cost of estimating the mean and variance of the projected mass change of a glacier. The problem size and complexity were chosen to reflect the challenges posed by future continental-scale studies while still facilitating a computationally feasible investigation of MFSE methods. When quantifying uncertainty introduced by a high-dimensional parameterization of the basal friction field, MFSE was able to reduce the mean-squared error in the estimates of the statistics by well over an order of magnitude when compared to a single-fidelity approach that only used the highest-fidelity model. This significant reduction in computational cost was achieved despite the low-fidelity models used being incapable of capturing the local features of the ice-flow fields predicted by the high-fidelity model. The MFSE algorithms were able to effectively leverage the high correlation between each model's predictions of mass change, which all responded similarly to perturbations in the model inputs. Consequently, our results suggest that MFSE could be highly useful for reducing the cost of computing continental-scale probabilistic projections of sea-level rise due to ice-sheet mass change.

54 ENVIRONMENTAL SCIENCES↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

Time-resolved chemical studies via time-of-flight secondary ion mass spectrometry

A method of performing time-of-flight secondary ion mass spectrometry on a sample includes the step of directing a beam of primary ions to the sample, and stimulating the migration of ions within the sample while the beam of primary ions is directed at the sample. The stimulation of the ions is cycled between a stimulation state and a lower stimulation state. Secondary ions emitted from the sample by the beam of primary ions are collected in a time-of-flight mass spectrometer. Time-of-flight secondary ion mass spectrometry is then performed on the secondary ions. A system for performing time-of-flight secondary ion mass spectrometry on a sample is also disclosed.

Ievlev, Anton V.↗

Search For Low-Mass Quark-Antiquark Resonances Produced With an Initial State Photon at 13 TeV Using the CMS Detector

We present a search for low-mass narrow qq̅ resonances. This search uses data from LHC pp collisions at a center of mass of 13 TeV in Run 2, and corresponds to an integrated luminosity of 137 fb^{-1}, currently using 10\% of data. Utilizing full Run 2 data allows the use of a lower photon pT threshold trigger than a previous analysis performed with only 2016 data, allowing this analysis to be more sensitive to resonances in the low mass region. We require an initial state photon recoiling against the narrow resonance, leading to the resonance having a high transverse momentum. The high pT decay products of the resonance collimate and are reconstructed as a single large jet with an internal two-pronged substructure. A two-pronged dijet score based on the ParticleNet tagger is used to select jets with two-pronged substructure. The background is estimated via a data-driven method using a transfer factor between the distributions which fail and pass the two-pronged substructure requirement. The new physics signal is searched for as a narrow peak excess above the Standard Model backgrounds in the jet mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dwarf galaxy halo masses from spectroscopic and photometric lensing in DESI and DES

We present the most precise and lowest-mass weak lensing measurements of dwarf galaxies to date, enabled by spectroscopic lenses from the Dark Energy Spectroscopic Instrument (DESI) and photometric lenses from the Dark Energy Survey (DES) calibrated with DESI redshifts. Using DESI spectroscopy from the first data release, we construct clean samples of galaxies with median stellar masses $\log_{10}(M_*/M_{\odot})=8.3-10.1$ and measure their weak lensing signals with sources from DES, KiDS, and SDSS, achieving detections with $S/N$ up to 14 for dwarf galaxies ($\log_{10}(M_*/M_{\odot})<$9.25) -- opening up a new regime for lensing measurements of low-mass systems. Leveraging DES photometry calibrated with DESI, we extend to a photometric dwarf sample of over 700,000 galaxies, enabling robust lensing detections of dwarf galaxies with combined $S/N=38$ and a significant measurement down to $\log_{10}(M_*/M_{\odot})=8.0$. We show that the one-halo regime (scales $\lesssim 0.15h^{-1}\rm Mpc$) is insensitive to various systematic and sample selection effects, providing robust halo mass estimates, while the signal in the two-halo regime depends on galaxy color and environment. These results demonstrate that DESI already enables precise dwarf lensing measurements, and that calibrated photometric samples extend this capability. Together, they pave the way for novel constraints on dwarf galaxy formation and dark matter physics with upcoming surveys like the Vera C. Rubin Observatory's LSST.

Treiber, Helena [Princeton U., Astrophys. Sci. Dep↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

The AME 2020 atomic mass evaluation (I). Evaluation of input data, and adjustment procedures*

Abstract This is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, AME2020. It includes complete information on the experimental input data that were used to derive the tables of recommended values which are given in Part II. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometric data which were used in a least-squares fit adjustment in order to determine the recommended mass values and their uncertainties. All input data, including both the accepted and rejected ones, are tabulated and compared with the adjusted values obtained from the least-squares fit analysis. Differences with the previous AME2016 evaluation are discussed and specific examples are presented for several nuclides that may be of interest to AME users.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mapping the N = 40 island of inversion: Precision mass measurements of neutron-rich Fe isotopes

Nuclear properties across the chart of nuclides are key to improving and validating our understanding of the strong interaction in nuclear physics. Here we present high-precision mass measurements of neutron-rich Fe isotopes performed at the TITAN facility. The multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS), achieving a resolving power greater than 600000 for the first time, enabled the measurement of 63–70 Fe, including first-time high-precision direct measurements (δm/m ≈ 10 -7 ) of 68–70 Fe, as well as the discovery of a long-lived isomeric state in 69 Fe. These measurements are accompanied by both mean-field and ab initio calculations using the most recent realizations which enable theoretical assignment of the spin-parities of the 69 Fe ground and isomeric states. Together with mean-field calculations of quadrupole deformation parameters for the Fe isotope chain, these results benchmark a maximum of deformation in the N = 40 island of inversion in Fe and shed light on trends in level densities indicated in the newly refined mass surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurements of neutron-rich nuclei near $N = 70$

The astrophysical origin for the chemical elements between the first and second r-process peaks is a matter of intense debate, with a number of nucleosynthesis processes at explosive stellar environments possibly contributing to their production. Reliable data on the trends of neutron separation energies of neutron-rich isotopes are required to model neutron-capture processes that would produce these elements. Masses of 104 Y, 106 Zr, 112 Mo, and 115 Tc have been measured with the time-of-flight-magnetic-rigidity (ToF–Bρ) technique at the National Superconducting Cyclotron Laboratory at Michigan State University. The experiment is the first application of the ToF–Bρ technique at the S800 spectrograph that reached the mass region relevant to heavy-element nucleosynthesis. Finally, the two-neutron separation energy deduced from the measured masses exhibits a smooth trend consistent with the theoretical predictions within the range of experimental uncertainty, indicating that there is no sudden shape transition in these isotopes as hinted at by previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

Virtual Slit Cycloidal Mass Spectrometry for Isotopic Measurements of Actinide Particles

The Virtual Slit Cycloidal Mass Spectrometer is a unique instrument for analysis of particles with mass spectrometry. It combines the unique properties of the cycloidal mass analyzer with capacitive transimpedance amplifier array detectors to make a portable instrument potentially capable of high sensitivity measurements on single particles, including high precision isotope ratios.

47 OTHER INSTRUMENTATION↗

Direct Experimental Observation of the Tetrabromine Cluster Br 4 by Synchrotron Photoionization Mass Spectrometry

We present a first spectroscopic characterization of the homoatomic polyhalogen tetrabromine, Br 4 , in the gas phase. Photolysis of CHBr 3 at 248 nm is used to generate atomic bromine radicals in a flow tube reactor. Resulting combination products are detected by photoionization mass spectrometry at the Advanced Light Source of the Lawrence Berkeley National Laboratory. Interpretation of the experimental mass spectra is informed by calculated adiabatic ionization energies carried out at the CCSD(T)/aug-cc-pVTZ//M06-2X/aug-cc-pVTZ and CCSD(T)/aug-cc-pVTZ//cam-B3LYP/6-311++g** levels of theory. Tunable VUV synchrotron radiation enables the collection of the mass-selected photoionization spectra by which Br 4 is assigned using Franck-Condon simulations of a Br 2 dimer with a stretched tetrahedral geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flying Blind, or Just Flying Under the Radar? The Underappreciated Power of De Novo Methods of Mass Spectrometric Peptide Identification

Mass spectrometry-based proteomics is a popular and powerful method for precise and highly multiplexed protein identification. The most common method of analyzing untargeted proteomics data is called database searching, where the database is simply a collection of protein sequences from the target organism, derived from genome sequencing. Experimental peptide tandem mass spectra are compared to simplified models of theoretical spectra calculated from the translated genomic sequences. However, in several interesting application areas, such as forensics, archaeology, venomics and others, a genome sequence may not be available, or the correct genome sequence to use is not known. In these cases, de novo peptide identification can play an important role. De novo peptide identification infers peptide sequence directly from the tandem mass spectrum without reference to a sequence database, usually using graph-based or machine learning algorithms. In this review, we provide a basic overview of de novo peptide identification methods and applications, briefly covering de novo algorithms and tools, and focusing in more depth on recent applications from venomics, metaproteomics, forensics, and characterization of antibody drugs.

proteomics, mass spectrometry, forensics, de novo ↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗