Generation and behavior of solar system magnetic fields

A range of problems aimed primarily at elucidating the character and consequences of magnetic-field generation in the solar system and at testing ideas against known properties of natural magnetic fields are covered. Among the specific subjects currently under investigation are the magnetohydrodynamic (MHD) character of the protosolar nebula, including the generation and behavior of magnetic fields, the electrical conductivity of dusty nebular gas, transient magnetodynamic and electrodynamic nebular phenomena, and the generation and dynamical behavior of planetary magnetic fields. During the past year, the focus of this research was on disk magnetic field generation and transient MHD heating events possibly associated with the protoplanetary nebula.

Levy, Eugene H.↗

Operation of A Sunpower M87 Cryocooler In A Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMS-02) is an experiment that will be flown as an attached payload on the International Space Station to detect dark matter and antimatter. It uses large superconducting magnets cooled with superfluid helium to bend the path of cosmic particles through a series of detectors, which then measure the mass, speed, charge, and direction of the particles. Four Sunpower M87N Stirling-cycle cryocoolers are used to extend the mission life by cooling the outer vapor-cooled shield of the dewar. The main magnet coils are separated by a distance of approximately 1 m and the coolers are located approximately 1.5 m from the center line of the magnet, where the field is as high as 925 gauss perpendicular to the cryocooler axis and 400 gauss along the cryocooler axis. Interactions between the applied magnetic field and the linear motor may result in additional forces and torques on the compressor piston. Motion of the compressor arid displacer pistons through the magnetic field spatial gradients will generate eddy currents. Additional eddy currents are created during magnet charge, discharge, and quench by the time-varying magnetic field. The results of tests to determine the magnitude of the forces, torques, and heating effects, as well as the need for additional magnetic shielding, are presented.

Breon, S. R.↗

Stage 2 Sub-Scale Magnetic Gear

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). In order to reduce risk, a sub-scale 5kW multistage MGG was first built. This project will benefit MHK device developers by providing an MHK PTO that overcomes the reliability concerns of the mechanical gears and the sizing constraints of the direct-drive generators. 7.67:1 gear ratio magnetic gear with a measured peak torque of 1796 N-m

16 TIDAL AND WAVE POWER↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Zirconium‐Based Metal–Organic Frameworks with Free Hydroxy Groups for Enhanced Perfluorooctanoic Acid Uptake in Water

Perfluorooctanoic acid (PFOA) is a highly recalcitrant organic pollutant, and its bioaccumulation severely endangers human health. While various methods are developed for PFOA removal, the targeted design of adsorbents with high efficiency and reusability remains largely unexplored. Here, in this work, the rational design and synthesis of two novel zirconium‐based metal‒organic frameworks (MOFs) bearing free ortho ‐hydroxy sites, namely noninterpenetrated PCN‐1001 and twofold interpenetrated PCN‐1002, are presented. Single crystal analysis of the pure ligand reveals that intramolecular hydrogen bonding plays a pivotal role in directing the formation of MOFs with free hydroxy groups. Furthermore, the transformation from PCN‐1001 to PCN‐1002 is realized. Compared to PCN‐1001, PCN‐1002 displays higher chemical stability due to interpenetration, thereby demonstrating an exceptional PFOA adsorption capacity of up to 632 mg g −1 (1.53 mmol g −1 ), which is comparable to the reported record values. Moreover, PCN‐1002 shows rapid kinetics, high selectivity, and long‐life cycles in PFOA removal tests. Solid‐state nuclear magnetic resonance results and density functional theory calculations reveal that multiple hydrogen bonds between the free ortho ‐hydroxy sites and PFOA, along with Lewis acid‐base interaction, work collaboratively to enhance PFOA adsorption.

36 MATERIALS SCIENCE↗

Conceptual design of BabyIAXO, the intermediate stage towards the International Axion Observatory

This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to g aγ ~ 1 . 5 × 10 -11 GeV -1 , and masses up to m a ~ 0.25 eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Common Tracking Software Project

Abstract The reconstruction of the trajectories of charged particles, or track reconstruction, is a key computational challenge for particle and nuclear physics experiments. While the tuning of track reconstruction algorithms can depend strongly on details of the detector geometry, the algorithms currently in use by experiments share many common features. At the same time, the intense environment of the High-Luminosity LHC accelerator and other future experiments is expected to put even greater computational stress on track reconstruction software, motivating the development of more performant algorithms. We present here A Common Tracking Software (ACTS) toolkit, which draws on the experience with track reconstruction algorithms in the ATLAS experiment and presents them in an experiment-independent and framework-independent toolkit. It provides a set of high-level track reconstruction tools which are agnostic to the details of the detection technologies and magnetic field configuration and tested for strict thread-safety to support multi-threaded event processing. We discuss the conceptual design and technical implementation of ACTS, selected applications and performance of ACTS, and the lessons learned.

97 MATHEMATICS AND COMPUTING↗

Emergent Ferromagnetism in CaRuO 3 /CaMnO 3 (111)-Oriented Superlattices

The boundary between CaRuO 3 and CaMnO 3 is an ideal test bed for emergent magnetic ground states stabilized through interfacial electron interactions. In this system, nominally antiferromagnetic and paramagnetic materials combine to yield interfacial ferromagnetism in CaMnO 3 due to electron leakage across the interface. In this work, we show that the crystal symmetry at the surface is a critical factor determining the nature of the interfacial interactions. Specifically, by growing CaRuO 3 /CaMnO 3 heterostructures along the (111) instead of the (001) crystallographic axis, we achieve a 3-fold enhancement of the magnetization and involve the CaRuO 3 layers in the ferromagnetism, which now spans both constituent materials. Importantly, the stabilization of a net magnetic moment in CaRuO 3 through strain effects has been long-sought but never consistently achieved, and our observations demonstrate the importance of interface engineering in the development of new functional heterostructures.

36 MATERIALS SCIENCE↗

A new tri-particle backlighter for high-energy-density plasmas (invited)

A new tri-particle mono-energetic backlighter based on laser-driven implosions of DT3He gas-filled capsules has been implemented at the OMEGA laser. This platform, an extension of the original D 3 He backlighter platform, generates 9.5 MeV deuterons from the T3He reaction in addition to 14.7 and 3.0 MeV protons from the deuterium and helium-3 reactants. The monoenergetic 14.7 and 3.0 MeV protons have been used with success at OMEGA and the NIF for both radiography and stopping-power studies. There are several advantages of having a third particle to diagnose plasma conditions: an extra time-of-flight-separated radiograph and an improved ability to discern between electric and magnetic fields. In cases where the 3.0 MeV protons cannot penetrate an experiment, the benefit of the additional 9.5 MeV deuterons is magnified. This capability is well-suited for NIF experiments, where large fields and plasma densities often preclude useful 3.0 MeV proton data. The advantages are demonstrated with radiographs of OMEGA plasmas with magnetic and electric fields. Tests using backlighter-scale 420 μm diameter thin glass capsules validate the platform’s extended backlighting capability. The performance characteristics of this backlighter, such as source size and timing, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying magnetic field driven lattice distortions in kagome metals at the femto-scale using scanning tunneling microscopy

A wide array of unusual phenomena has recently been uncovered in kagome solids. The charge density wave (CDW) state in the kagome superconductor AV 3 Sb 5 , in particular, intrigued the community; the CDW phase appears to break the time-reversal symmetry despite the absence of spin magnetism, which has been tied to exotic orbital loop currents possibly intertwined with magnetic field tunable crystal distortions. To test this connection, precise determination of the lattice response to an applied magnetic field is crucial but can be challenging at the atomic scale. We establish a scanning tunneling microscopy (STM) based method to study the evolution of the AV 3 Sb 5 atomic structure as a function of magnetic field. The method substantially reduces the errors of typical STM measurements, which are at the order of 1% when measuring an in-plane lattice constant change. Here, we find that the out-of-plane lattice constant of AV 3 Sb 5 remains unchanged (within 10 —6 ) by the application of both in-plane and out-of-plane magnetic fields. We also reveal that the in-plane lattice response to magnetic field is at most at the order of 0.05%. Our experiments provide further constraints on time-reversal symmetry breaking in kagome metals and establish a tool for higher-resolution extraction of the field-lattice coupling at the nanoscale applicable to other quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved measurements of nonlinear integrable optics at IOTA

Nonlinear integrable optics (NIO) are a promising novel approach at improving the stability of high intensity beams. Implementations of NIO based on specialized magnetic elements are being tested at the Integrable Optics Test Accelerator (IOTA) at Fermilab. One method of verifying proper implementation of these solutions is by measuring the analytic invariants predicted by theory. The initial measurements of nonlinear invariants were performed during IOTA run in 2019/20, however the covid-19 pandemic prevented the full-scale experimental program from being completed. Several important improvements were implemented in IOTA for the 2022/23 run, including the operation at higher beam energy of 150 MeV, improved optics control, and chromaticity correction. This report presents on the improved calibrations of the NIO for nonlinear invariant measurements.

43 PARTICLE ACCELERATORS↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Analysis of the MQXFA Low Beta Quadrupoles for HL-LHC after 50% magnet assembly complete +

The US HL-LHC Accelerator Upgrade Project (AUP) is fabricating the MQXFA magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC (HL-LHC). This is the first production of Nb3Sn magnets for a particle accelerator, together with the MQXFB magnets for Q2a and Q2b. Here we show status and some results of MQXFA magnets fabrication and vertical test.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QXFA 167 Coil Fabrication Report

QXFA is a cosine theta coil used in the MQXFA, a Nb3Sn superconducting accelerator quadrupole magnet to be installed in the High-Luminosity LHC Interaction Regions. A series of MQXFA magnets is fabricated and tested by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). This report details the fabrication process of the QXFA coil (QXFA 167) using Wind-and-React method, conducted from February 6 to March 20, 2025. The content covers coil winding, curing, and reaction, based on the travelers of FNAL as well as the observations and records by the author. The coil fabrication processes following heat reaction, including the impregnation process, are not covered in this report, as they were carried out after March 20.

43 PARTICLE ACCELERATORS↗

Competition for Management and Operation of Los Alamos National Laboratory

Reconnection is one of the key nonlinear processes in a plasma, in which great amounts of magnetic energy can be rapidly transformed and released via a change in magnetic topology. Field lines of opposite polarity flow together, annihilate, and release pent-up magnetic stress. Snapshots from one of our 2D test simulations (Fig 1) demonstrate key stages in magnetic reconnection. First, antiparallel magnetic field lines are brought together by an inflow in the z direction (the “upstream”). Second, the field lines begin reconnecting and an outflow forms in the x direction (the “downstream”). Finally, in the fully nonlinear stage, structures known as plasmoids are formed.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining Stability Margins in Adiabatic Superconducting Magnets with 3-D Finite Element Analysis

Superconducting magnets play a key role in the development of experiments at Fermilab; understanding the operating stability of these can allow us to utilize more potent magnets for future experiments (like the proposed Muon Collider), optimize the design of magnets in more immediate experiments (like Mu2e), and research the future use of more exotic materials (like high-temperature superconductors). This summer, I developed a 3-D parametric FEA program in ANSYS Mechanical APDL that simulates quench in superconducting magnets, and I also developed a parametric MATLAB program that predicts thermal behavior in magnet quench using the MIITS method. These programs can provide useful quenching parameters (like minimum quench energy and normal zone propagation velocity) for different cases of quench, leading to the previously mentioned objective of magnet design optimization. To test the programs, preliminary cases were run and the data produced was compared and analyzed. The results of these analyses, as well as the program operating methods, are discussed in this project.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computer program performs aerothermodynamic flight test data correlation

Computer program plots flight test data /stored on magnetic tape during the flight/ with comparative data from other tapes /design and post-flight predictions/. Information as to which measurements are on each tape, the order in which they appear, and the exact time span is supplied by the source of the data.

Schmus, F.↗