Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Accurate and confident prediction of electron beam longitudinal properties using spectral virtual diagnostics

Abstract Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool’s accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE’s user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational wave modes in matter

Here, a general linear gauge-invariant equation for dispersive gravitational waves (GWs) propagating in matter is derived. This equation describes, on the same footing, both the usual tensor modes and the gravitational modes strongly coupled with matter. It is shown that the effect of matter on the former is comparable to diffraction and therefore negligible within the geometrical-optics approximation. However, this approximation is applicable to modes strongly coupled with matter due to their large refractive index. GWs in ideal gas are studied using the kinetic average-Lagrangian approach and the gravitational polarizability of matter that we have introduced earlier. In particular, we show that this formulation subsumes the kinetic Jeans instability as a collective GW mode with a peculiar polarization, which is derived from the dispersion matrix rather than assumed a priori. This forms a foundation for systematically extending GW theory to GW interactions with plasmas, where symmetry considerations alone are insufficient to predict the wave polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Good plasmons in a bad metal

Correlated metals may exhibit unusually high resistivity that increases linearly in temperature, breaking through the Mott-Ioffe-Regel bound, above which coherent quasiparticles are destroyed. The fate of collective charge excitations, or plasmons, in these systems is a subject of debate. Several studies have suggested that plasmons are overdamped, whereas other studies have detected propagating plasmons. Here, in this work, we present direct nano-optical images of low-loss hyperbolic plasmon polaritons (HPPs) in the correlated van der Waals metal MoOCl 2 . HPPs are plasmon-photon modes that waveguide through extremely anisotropic media and are remarkably long-lived in MoOCl 2 . Photoemission data presented here reveal a highly anisotropic Fermi surface, reconstructed and made partly incoherent, likely through electronic interactions as explained by many-body theory. HPPs remain long-lived despite this, revealing previously unseen imprints of many-body effects on plasmonic collective modes.

36 MATERIALS SCIENCE↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An In-situ and Direct Confirmation of Super-Planckian Thermal Radiation Emitted From a Metallic Photonic-Crystal at Optical Wavelengths

Planck’s law predicts the distribution of radiation energy, color and intensity, emitted from a hot object at thermal equilibrium. The Law also sets the upper limit of radiation intensity, the blackbody limit. Recent experiments reveal that micro-structured tungsten can exhibit significant deviation from the blackbody spectrum. However, whether thermal radiation with weak non-equilibrium pumping can exceed the blackbody limit in the far field remains un-answered experimentally. Here, we compare thermal radiation from a micro-cavity/tungsten photonic crystal (W-PC) and a blackbody, which are both measured from the same sample and also in-situ. We show that thermal radiation can exceed the blackbody limit by >8 times at λ=1.7 μm resonant wavelength in the far-field. Our observation is consistent with a recent calculation by Wang and John performed for a 2D W-PC filament. This finding is attributed to non-equilibrium excitation of localized surface plasmon resonances coupled to nonlinear oscillators and the propagation of the electromagnetic waves through non-linear Bloch waves of the W-PC structure. This discovery could help create super-intense narrow band thermal light sources and even an infrared emitter with a laser-like input-output characteristic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Artificial intelligence time series forecasting for feed-forward laser stabilization

Laser plasma accelerators, typically operating at 1–10 Hz repetition rates, have the ability to produce high-quality electron beams in compact, all-optical-driven configurations, with the electron beams uniquely suited for a wide variety of accelerator-based applications. However, fluctuations and drifts in the laser delivery to the meter-scaled and below plasma target (the electron beam source) will translate into electron beam source variations that can limit their utility for demanding applications like light sources or linear colliders. Commercially available active feedback laser stabilization systems are intrinsically bandwidth limited due to their integration with multi-inch corrective mirror mounts which minimizes their effectiveness. In this manuscript, we present a Neural Network time series forecaster that can predict laser position fluctuations of the laser delivery to the final target well ahead of a future laser shot. The Root-Mean-Square-Error (RMSE) of the prediction accuracy was < 2 μ m for a 1 / e 2 beam radius of 34 μ m . Our feed-forward approach serves as a first-step in circumventing the bandwidth limitations imposed by the currently available stabilization systems since it allows for mirrors to be moved into position ahead of time to offset the predicted future position drift. This will help advance laser plasma accelerator research by providing greater robustness and stability needed for its applications.

Berger, Curtis↗

Spin/valley pumping of resident electrons in WSe2 and WS2 monolayers

Abstract Monolayers of transition metal dichalcogenides are ideal materials to control both spin and valley degrees of freedom either electrically or optically. Nevertheless, optical excitation mostly generates excitons species with inherently short lifetime and spin/valley relaxation time. Here we demonstrate a very efficient spin/valley optical pumping of resident electrons in n-doped WSe 2 and WS 2 monolayers. We observe that, using a continuous wave laser and appropriate doping and excitation densities, negative trion doublet lines exhibit circular polarization of opposite sign and the photoluminescence intensity of the triplet trion is more than four times larger with circular excitation than with linear excitation. We interpret our results as a consequence of a large dynamic polarization of resident electrons using circular light.

36 MATERIALS SCIENCE↗

Polarization angle requirements for CMB B-mode experiments. Application to the LiteBIRD satellite

A methodology to provide the polarization angle requirements for different sets of detectors, at a given frequency of a CMB polarization experiment, is presented. The uncertainties in the polarization angle of each detector set are related to a given bias on the tensor-to-scalar ratio r parameter. The approach is grounded in using a linear combination of the detector sets to obtain the CMB polarization signal. In addition, assuming that the uncertainties on the polarization angle are in the small angle limit (lower than a few degrees), it is possible to derive analytic expressions to establish the requirements. The methodology also accounts for possible correlations among detectors, that may originate from the optics, wafers, etc. The approach is applied to the LiteBIRD space mission. We show that, for the most restrictive case (i.e., full correlation of the polarization angle systematics among detector sets), the requirements on the polarization angle uncertainties are of around 1 arcmin at the most sensitive frequency bands (i.e., ≈ 150 GHz) and of few tens of arcmin at the lowest (i.e., ≈ 40 GHz) and highest (i.e., ≈ 400 GHz) observational bands. Conversely, for the least restrictive case (i.e., no correlation of the polarization angle systematics among detector sets), the requirements are ≈ 5 times less restrictive than for the previous scenario. At the global and the telescope levels, polarization angle knowledge of a few arcmins is sufficient for correlated global systematic errors and can be relaxed by a factor of two for fully uncorrelated errors in detector polarization angle. The reported uncertainty levels are needed in order to have the bias on r due to systematics below the limit established by the LiteBIRD collaboration.

79 ASTRONOMY AND ASTROPHYSICS↗

Modelling galaxy cluster triaxiality in stacked cluster weak lensing analyses

Counts of galaxy clusters offer a high-precision probe of cosmology, but control of systematic errors will determine the accuracy of this measurement. Using Buzzard simulations, we quantify one such systematic, the triaxiality distribution of clusters identified with the redMaPPer optical cluster finding algorithm, which was used in the Dark Energy Survey Year-1 (DES Y1) cluster cosmology analysis. We test whether redMaPPer selection biases the clusters’ shape and orientation and find that it only biases orientation, preferentially selecting clusters with their major axes oriented along the line of sight. Modelling the richness–mass relation as log-linear, we find that the log-richness amplitude ln (A) is boosted from the lowest to highest orientation bin with a significance of 14σ, while the orientation dependence of the richness-mass slope and intrinsic scatter is minimal. We also find that the weak lensing shear-profile ratios of cluster-associated dark haloes in different orientation bins resemble a ‘bottleneck’ shape that can be quantified with a Cauchy function. We test the correlation of orientation with two other leading systematics in cluster cosmology – miscentering and projection – and find a null correlation. The resulting mass bias predicted from our templates confirms the DES Y1 finding that triaxiality is a leading source of bias in cluster cosmology. However, the richness-dependence of the bias confirms that triaxiality does not fully resolve the tension at low-richness between DES Y1 cluster cosmology and other probes. Our model can be used for quantifying the impact of triaxiality bias on cosmological constraints for upcoming weak lensing surveys of galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Data-Driven Approaches for Bead Geometry Prediction Via Melt Pool Monitoring

In the realm of additive manufacturing, the selection of process parameters to avoid over and under deposition entails a time-consuming and resource-intensive trial-and-error approach. Given the distinct characteristics of each part geometry, there is a pressing need for advancing real-time process monitoring and control to ensure consistent and reliable part dimensional accuracy. Here, this research shows that support vector regression (SVR) and convolutional neural network (CNN) models offer a promising solution for real-time process control due to the models’ abilities to recognize complex, non-linear patterns with high accuracy. A novel experiment was designed to compare the performance of SVR and CNN models to indirectly detect bead height from a coaxial image of a melt pool from a single-layer, single bead build. The study showed that both SVR and CNN models trained on melt pool data collected from a coaxial optical camera can accurately predict the bead height with a mean absolute percentage error of 3.67% and 3.68%, respectively.

36 MATERIALS SCIENCE↗

Temporal characterization of fundamental plasma parameters in pulsed liquid electrode plasma (LEP) optical emission spectrometry

The fundamental characteristics of liquid electrode plasma (LEP), a pulsed plasma source for optical emission spectrometry, were investigated. Two distinct phases were observed during the process of pulsed plasma generation, namely bubble generation and active plasma discharge. Additionally the ionization efficiency of the LEP, with Mg as a representative analyte, was gauged from the ratio of Mg II 279.553 nm to Mg I 285.213 nm emission and was found to increase from about 5% to 20% in a close-to-linear fashion with the discharge voltage from 800 V to 1200 V. The Mg II/Mg I ratio of the LEP was 2.5 to 3 orders of magnitude less than that typically offered by an inductively coupled plasma (ICP) but was comparable to other solution-based glow discharges. It was found that an off-time interval of more than 150 ms between successive discharge pulses was required to obtain a stable pulse-to-pulse discharge current. Temporally resolved emissions of Mg II 279.6 nm, Mg I 285.2 nm, Fe I 373.5 nm, OH band head at 306 nm, and Hα line at 656.3 nm showed that the background species (OH band and Hα line) reached their maximum emission intensities at around 0.5 ms to 0.7 ms with respect to the onset of the discharge pulse whereas the maximum emissions were observed between 0.7 ms to 0.9 ms for analyte species (Mg and Fe lines). The electron density observed in the present work was in the range from 5.7 × 10 15 cm -3 to 8.2 × 10 15 cm -3 , which was similar to those found in an analytical ICP. The temporal averaged OH rotational temperature was 3300 K, which was comparable to the values of an analytical ICP and solution-based glow discharges. By contrast, the temporally averaged Fe I excitation temperature was around 8900 K, which was even higher than that of an analytical ICP and roughly triple the values obtained by techniques based on glow discharge of liquid samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

White-light interferometry for early-stage metal oxide growth characterization

Oxidation of metals can provide a functional oxide film or an oxide layer that can lead to material degradation causing performance limiting concerns. Because of the technological and economic impacts of oxidation, understanding early-stage oxidation growth and its mechanisms is of high importance. Unfortunately, poor empirical data during early-stage oxidation has left our current understanding of oxidation incomplete and woefully inadequate. Measurement techniques previously used for oxidation kinetics characterization include microbalance, x-ray diffraction, Fourier-transform infrared spectroscopy, and spectroscopic ellipsometry. However, these techniques lack the necessary time-resolution or vertical resolution in addition to not providing any spatial data, which is essential to early-stage oxidation studies to understand both oxidation kinetics and mechanisms. Here, a novel rapid and surface-sensitive data collection technique that provides three-dimensional spatial data of a growing oxide layer with sub-nanometer thickness resolution using white-light interferometry has been developed. This technique will be the first technique capable of providing real-time spatial results of early-stage oxidation growth. The effectiveness of this characterization tool is shown by observing the early-stage oxidation kinetics and film cracking of uranium heated to 90 °C under 500 torr of pure O 2 . Initially a parabolic oxidation growth is observed. Once the oxide layer reaches ≈ 30 nm, the epitaxial stresses between the uranium substrate and oxide film layer causes localized cracking in addition to the observed transition of the parabolic growth rate to a linear growth rate. The results of the white-light interferometry are verified by glancing incidence x-ray diffraction.

47 OTHER INSTRUMENTATION↗

Comparison of quantum advantage experiments using random circuit sampling

Random circuit sampling, the task of sampling bit strings from a random unitary operator, has been implemented to demonstrate quantum advantage on the Sycamore quantum processor with 53 qubits and on the Zuchongzhi quantum processor with 56 and 61 qubits. Recently, it was claimed that classical computers using tensor network simulation could catch on to current noisy quantum processors for random circuit sampling. While the linear cross-entropy benchmark fidelity was used to certify all these claims, it may not capture statistical properties of outputs in detail. Here, we compare the bit strings sampled from classical computers using tensor network simulation by Pan et al. [F. Pan, K. Chen, and P. Zhang, Phys. Rev. Lett. 129, 090502 (2022)] and by Kalachev et al. [G. Kalachev, P. Panteleev, P. Zhou, and M.-H. Yung, arXiv:2112.15083] with the bit strings from the Sycamore quantum processor. It is shown that all of Kalachev et al.'s samples passed the NIST random number tests. The heat maps of bit strings show that Pan et al.'s and Kalachev et al.'s samples are quite different from the Sycamore or Zuchongzhi samples. The analysis with the Marchenko-Pastur distribution and the Wasssertein distances demonstrates that Kalachev et al.'s samples are statistically closer to the Sycamore samples than Pan et al.'s while the three datasets have similar values for the linear cross-entropy fidelity. In conclusion, our finding implies that further study is needed to certify or beat the claims of quantum advantage using random circuit sampling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress towards understanding ultranonlocality through the wave-vector and frequency dependence of approximate exchange-correlation kernels

In the framework of time-dependent density functional theory (TDDFT), the exact exchange-correlation (xc) kernel f xc (n, q, ω) determines the ground-state energy, excited-state energies, lifetimes, and the time-dependent linear density response of any many-electron system. The recently developed MCP07 xc kernel f xc (n, q, ω) of A. Ruzsinszky et al. [Phys. Rev. B 101, 245135 (2020)] yields excellent uniform electron gas (UEG) ground-state energies and plausible plasmon lifetimes. As MCP07 is constructed to describe f xc of the UEG, it cannot capture optical properties of real materials. To verify this claim, we follow Nazarov et al. [Phys. Rev. Lett. 102, 113001 (2009)] to construct the long-range, dynamic xc kernel, lim q→0 f xc (n, q, ω) = -α(ω)e 2 /q 2 , of a weakly inhomogeneous electron gas, using MCP07 and other common xc kernels. The strong wavevector and frequency dependence of the “ultranonlocality” coefficient α(ω) is demonstrated for a variety of simple metals and semiconductors. We examine how imposing exact constraints on an approximate kernel shapes α(ω). Comparisons to kernels derived from correlated-wavefunction calculations are drawn.

36 MATERIALS SCIENCE↗

Dephasingless Laser Wakefield Acceleration

Laser wakefield accelerators (LWFAs) produce significantly high gradients enabling compact accelerators and radiation sources, but face design limitations, such as dephasing, occurring when trapped electrons outrun the accelerating phase of the wakefield. In this report we combine spherical aberration with a novel cylindrically symmetric echelon optic to spatiotemporally structure an ultra-short, high-intensity laser pulse that can overcome dephasing by propagating at any velocity over any distance. The ponderomotive force of the spatiotemporally shaped pulse can drive a wakefield with a phase velocity equal to the speed of light in vacuum, preventing trapped electrons from outrunning the wake. Simulations in the linear regime and scaling laws in the bubble regime illustrate that this dephasingless LWFA can accelerate electrons to high energies in much shorter distances than a traditional LWFA—a single 4.5 m stage can accelerate electrons to TeV energies without the need for guiding structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗

Spectroscopic Properties of Americium(III) in Mineral Acid Media

We report the preparation and optical characterization of three solutions of Am(III) in common aqueous (aq.) mineral acids (HCl, HNO 3 and HBr), including absorption, emission, and Raman vibrational analyses. To our knowledge, this study provides the first detailed absorption spectra of Am(III) spanning the entire UV/Vis/NIR region in these mineral acids reported since the 1960s. Here, using this high-resolution absorption data, provided in an open access format for the broader field, we build on prior work by Carnall and others to provide detailed optical analysis including all transition assignments. This work also includes the first reported absorption spectrum of Am(III) in aq. HBr. Characteristic Am(III) luminescence could be detected from all three samples. These are the first reports of emission from Am(III) in these acid systems, which build on prior emission reports collected from aq. HClO 4 solutions. The acquired emission spectra display anion-dependent shifting of the visible-region transitions by up to 21 nm from their predicted positions, akin to the nephelauxetic effect. The shift magnitude trends linearly according to the acid p K a and more generally according to the transition metal spectrochemical series. These ligand field effects, coupled with luminescence lifetime experiments, indicate that weak Am-X interactions persist in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗