Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Engineered optical fibers and uses thereof

A system comprises an electromagnetic radiation source, a polarizing element, a mode converter, an optical fiber, and a measurement device. The polarizing element receives electromagnetic radiation produced by the electromagnetic radiation source and outputs linearly-polarized electromagnetic radiation having a linear polarization angle θ1. The mode converter converts the linearly-polarized electromagnetic radiation to an orbital angular momentum (OAM) mode of linearly-polarized electromagnetic radiation with topological charge Li. The OAM mode of linearly-polarized electromagnetic radiation is a superposition of first and second OAM modes with topological charges Li and opposite circular polarizations. The optical fiber supports propagation of the first and second OAM modes with an absolute effective index difference Δneff greater than or equal to 5×10−5, such that linearly-polarized electromagnetic radiation with linear polarization angle θ2 is emitted by the optical fiber. The measurement device is configured to determine a property of the electromagnetic radiation based on the polarization angle θ2.

Ramachandran, Siddharth↗

Improved photographic prints with a linear radial transmission filter

Linear Radial Transmission Filter (LRTF) is easy to use and yet results in prints which depict more information contained in negative than can be shown by direct printing. LRTF is optical-quality filter which has maximum transmission in center and linear drop in transmission radially out from center.

Weinstein, L. M.↗

Study of the effects of MeV Ag, Cu, Au, and Sn implantation on the optical properties of LiNbO3

The authors present the results of characterization of linear absorption and nonlinear refractive index of Au, Ag, Cu and Sn ion implantation into LiNbO3. Ag was implanted at 1.5 MeV to fluences of 2 to 17 x 17(exp 16)/sq cm at room temperature. Au and Cu were implanted to fluences of 5 to 20 x 10(exp 16)/sq cm at an energy of 2.0 MeV. Sn was implanted to a fluence of 1.6 x 10(exp 17)/sq cm at 160 kV. Optical absorption spectrometry indicated an absorption peak for the Au implanted samples after heat treatment at 1,000 C at approx. 620 nm. The Ag implanted samples absorption peaks shifted from approx. 450 nm before heat treatment to 550 nm after 500 C for 1h. Heat treatment at 800 C returned the Ag implanted crystals to a clear state. Cu nanocluster absorption peaks disappears at 500 C. No Sn clusters were observed by optical absorption or XRD. The size of the Ag and Au clusters as a function of heat treatment were determined from the absorption peaks. The Ag clusters did not change appreciably in size with heat treatment. The Au clusters increased from 3 to 9 nm diameter upon heat treatment at 1000 C. TEM analysis performed on a Au implanted crystal indicated the formation of Au nanocrystals with facets normal to the c-axis. Measurements of the nonlinear refractive indices were carried out using the Z-scan method with a tunable dye laser pumped by a frequency doubled mode-locked Nd:YAG laser. The dye laser had a 4.5 ps pulse duration time and 76 MHz pulse repetition rate (575 nm).

Williams, E. K.↗

A sample of lobe-dominated quasars with Mg II absorption lines

We present a sample of quasars which are lobe-dominated in their radio emission and contain Mg II absorption line systems. This sample will be useful in a search for redshifted H I 21 cm absorbers which are along lines of sight different from the optical. These systems will allow the measurement of the linear size and related physical parameters of the absorption line clouds. We have defined a set of criteria for selecting these objects and obtained the necessary data to assemble a sample based on these criteria. Out of 4234 QSOs we find 31 lobe-dominated quasars which are appropriate for optical and radio absorption line study in the Northern Hemisphere. We have obtained or located optical spectra for 29 of these 31 quasars. In the optical spectra we find 17 Mg II absorption systems with redshifts between 0.3 and 1.4 and Mg II 2796 A rest equivalent widths between 0.3 and 2.0 A. Based on statistics of 21 cm absorption in Mg II selected QSOs we expect this sample of 17 systems to yield one or two new H I absorbers. In this paper we give an analysis of our criteria, discuss the sample, and present new VLA observations of 16 quasars.

Aldcroft, Thomas L.↗

The evolution of weak radio galaxies at radio and optical wavelengths

The statistical properties of radio sources are reviewed. The linear sizes of gE radio galaxies increase mildly with radio power, and decrease drastically with redshift. Combined with the redshift distribution, this causes angular sizes to decrease continuously towards fainter fluxes. Nonetheless, the fraction of large sources is not negligible at any flux level, requiring a revision of the resolution correction to the source counts. The 1.4 GHz counts are now well established (within 5 percent) from 10,575 sources in 24 different surveys. This makes it possible to study fied-to-field anisotropies. None are found in the wide area surveys for S(1.4) greater than 10 mJy, and only marginal anisotropies in some small-area surveys. These are compared to the redshift distribution and the angular correlation function of radio sources.

Windhorst, Rogier↗

Advanced multispectral remote sensing technology and applications; Proceedings of the Conference, Arlington, VA, May 6, 7, 1982

Sensor system concepts are discussed, taking into account a multispectral linear array instrument design, an improved earth resources sensing instrument, design tradeoffs for a multispectral linear array instrument, imaging spectrometer technologies for advanced earth remote sensing, and the design concept for an optimized earth radiation budget sensor. Topics related to supporting optics and signal processing methodologies are explored, giving attention to two mirror objective design for multispectral remote sensing, the measurement of optical modulation functions in sparsely sampled mosaic focal plane arrays, multispectral linear array focal plane signal processing, signal processing for the NASA multispectral linear array, the concept for a multiple resolution pushbroom sensor, and the evolution of the octal radiometer. Techniques and applications for multispectral data are considered along with aspects of focal plane technology.

Ando, K. J.↗

Development of an Optical Model for the MEDLI2 Radiometer

We present an optical model of the MEDLI2 radiometer, which was flown onboard the Mars 2020 vehicle during atmospheric entry on February 18, 2021. The proposed model takes into account the radiometer geometry and optical phenomena such as reflection, refraction, and absorption to estimate the signal loss inherent in the design of the radiometer. The model serves as a filter, which can be used to convert predicted total radiative heat fluxes on the radiometer window into predicted measured heat fluxes, enabling more accurate comparisons of the radiometer flight data with predicted radiometer measurements. Optical properties of the radiometer’s sapphire window are inferred from spectral transmissivity measurements. A modified Lorentz Oscillator Model is used to represent the dielectric function of the window and is fit to the transmission data. The resulting optical model of the radiometer is validated against experimental data used to measure the dependence of the radiometer output voltage on the incident angle of the light impinging on it. Comparison of predicted radiometer measurements with the MEDLI2 flight data show good agreement between the predicted and measured peak heat fluxes, though offset at different times. A linear increase in the signal loss due to radiometer optics alone is also demonstrated, suggesting that the changing shock angle over the course of the trajectory impacts the signal loss.

MEDLI2↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗

Mechanochromic Palettes Based on Optical Rotation in Cholesteric Liquid Crystal Elastomers for Visual Signalling

Mechanochromic photonic materials present promising prospects for enhancing diverse facets of human life. Cholesteric liquid crystal elastomers (CLCEs) present immediate mechanochromic properties, allowing their utility in various fields, including camouflages, textiles, and anticounterfeiting. Nonetheless, it is essential to provide differentiated color information corresponding to diverse types and degrees of deformation for practical use in real life. Herein, the mechanochromic responses of CLCEs are investigated using their optical rotation under compression and uniaxial stretching. The CLCEs exhibit the same reflection colors indistinguishable for compression and uniaxial stretching due to their contracted pitches. In contrast, the linearly polarized light passing through deformed CLCEs can be modulated by optical rotation, resulting in distinct transmission colors that can be discerned through mechanical deformations. A visual signaling system with color information derived from optical rotation is demonstrated. By comprehending and manipulating the mechanoresponsive behavior of CLCEs, these materials can be advanced into innovative solutions with enhanced functionality and performance, thereby broadening their applications for human life enhancement.

36 MATERIALS SCIENCE↗

Mechanochromic Palettes of Cholesteric Liquid Crystal Elastomers for Visual Signaling

Mechanochromic photonic materials present promising prospects for enhancing diverse facets of human life. Cholesteric liquid crystal elastomers (CLCEs) present immediate mechanochromic properties, allowing their utility in various fields, including camouflages, textiles, and anticounterfeiting. Nonetheless, it is essential to provide differentiated color information corresponding to diverse types and degrees of deformation for practical use in real life. Herein, we investigate the mechanochromic responses of CLCEs using their optical rotation under compression and uniaxial stretching. The CLCEs exhibit the same reflection colors indistinguishable for compression and uniaxial stretching due to their contracted pitches. In contrast, the linearly polarized light passing through deformed CLCEs can be modulated by optical rotation, resulting in distinct transmission colors that can be discerned through mechanical deformations. We demonstrate a visual signaling system with color information derived from optical rotation. By comprehending and manipulating the mechanoresponsive behavior of CLCEs, we can advance these materials into innovative solutions with enhanced functionality and performance, thereby broadening their applications for human life enhancement.

36 MATERIALS SCIENCE↗

Comparing Machine Learning and Physics-Based Nanoparticle Geometry Determinations Using Far-Field Spectral Properties

Anisotropic metal nanostructures exhibit polarization-dependent light scattering, a property which has been widely studied and exploited to determine orientations of subwavelength structures using far-field microscopy. Here we explore the use of variational autoencoders (VAEs) to determine the geometries of gold nanorods (NRs) such as in-plane orientation and aspect ratio under linearly polarized dark-field illumination in an optical microscope. We enforce a shared latent space to connect two VAEs trained separately with polarized dark-field scattering spectra and electron microscopy images and achieve image prediction (shape, orientation, and size) of Au NRs using only polarized dark-field scattering spectra. We determine the geometrical parameters of orientational angle and aspect ratio quantitatively via both our dual-VAE and physics-based analysis on the input scattering spectra. We show that orientational angle prediction by dual-VAE performs well with only a small (~300 particle) training set, yielding a mean absolute error (MAE) of 14.4° and a concordance correlation coefficient (CCC) of 0.95. This performance is only marginally worse than the physics-based cos(2?) fitting approach between the scattering intensity and the polarizing angle, which achieves MAE of 8.78° and CCC of 0.99. Aspect ratio determination is also comparable for the dual-VAE and physics-based fitting comparison (MAE of 0.21 vs. 0.23 and CCC of 0.53 vs. 0.68). Here, this dual encoder-decoder architecture effectively exploits the structure-property relationships of plasmonic nanostructures to construct a cross-modal machine learning (ML) approach, providing a pathway to employ ML approaches to address other structure-property relationships in materials science.

Dark-field scattering↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-frequency sub-Doppler spectroscopy of the caesium D{sub 1} line in various configurations of counterpropagating laser beams

Sub-Doppler resonances in caesium vapours are studied in a laser field produced by counterpropagating two-frequency light beams with mutually orthogonal linear polarisations. The beams are in resonance with optical transitions in the D{sub 1} line, the frequency difference of the field spectral components being equal to the hyperfine ground-state splitting in the Cs atom (∼9.2 GHz). It has already been shown that in this configuration, the hypercontrast effect can be observed for sub-Doppler resonances, which makes this configuration promising for the employment in new-generation miniature optical frequency standards. In the present work, two different two-frequency configurations are compared with each other and with the single-frequency configuration widely used in practice for observing saturated absorption resonances. The parameters of nonlinear resonances are measured at various temperatures of caesium vapours and at different optical field intensities. The results of the investigations performed make it possible to find an optimal two-frequency scheme for exciting nonlinear resonances and to estimate a potential of the scheme for its applications in quantum metrology. (laser spectroscopy of atoms)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gauge invariance of light-matter interactions in first-principle tight-binding models

In this work, we study the different ways of introducing light-matter interaction in first-principle tight-binding (TB) models. The standard way of describing optical properties is the velocity gauge, defined by linear coupling to the vector potential. In finite systems a transformation to represent the electromagnetic radiation by the electric field instead is possible, albeit subtleties arise in periodic systems. The resulting dipole gauge is a multi-orbital generalization of the Peierls substitution. In this work we investigate the accuracy for both pathways, with particular emphasis on gauge invariance, for TB models constructed from maximally localized Wannier functions. This approach accurately captures the light-matter interaction close to the Fermi level. Focusing on paradigmatic two-dimensional materials, we construct first-principle models and calculate the response to electromagnetic fields in linear response and for strong excitations. Benchmarks against fully converged first-principle calculations allow for ascertaining the accuracy of the TB models. We find that the dipole gauge provides a more accurate description than the velocity gauge in all cases. The main deficiency of the velocity gauge is an imperfect cancellation of paramagnetic and diamagnetic current. Formulating a corresponding sum rule however provides a way to explicitly enforce this cancellation. This procedure corrects the TB models in the velocity gauge, yielding excellent agreement with dipole gauge and thus restoring gauge invariance.

2-dimensional systems↗

Gait Characterization and Analysis of Hereditary Amyloidosis Associated with Transthyretin Patients: A Case Series

Hereditary amyloidosis associated with transthyretin (ATTRv), is a rare autosomal dominant disease characterized by length-dependent symmetric polyneuropathy that has gait impairment as one of its consequences. The gait pattern of V30M ATTRv amyloidosis patients has been described as similar to that of diabetic neuropathy, associated with steppage, but has never been quantitatively characterized. In this study we aim to characterize the gait pattern of patients with V30M ATTRv amyloidosis, thus providing information for a better understanding and potential for supporting diagnosis and disease progression evaluation. We present a case series in which we conducted two gait analyses, 18 months apart, of five V30M ATTRv amyloidosis patients using a 12-camera, marker based, optical system as well as six force platforms. Linear kinematics, ground reaction forces, and angular kinematics results are analyzed for all patients. All patients, except one, showed a delayed toe-off in the second assessment, as well as excessive pelvic rotation, hip extension and external transverse rotation and knee flexion (in stance and swing phases), along with reduced vertical and mediolateral ground reaction forces. The described gait anomalies are not clinically quantified; thus, gait analysis may contribute to the assessment of possible disease progression along with the clinical evaluation.

Vilas-Boas, Maria do Carmo (ORCID:000000025012789X↗

Electro-optical processing of phased-array antenna data

An on-line two-dimensional optical processor has been used to process simulated linear and planar phased-array radar data off-line but at real-time data rates. The input transducer is an electron-beam-addressed KD2PO4 light valve.

Casasent, D.↗