Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Mirror with reflectance variable in amplitude and phase. 1. Modelling of a mirror with reflectance variable in amplitude and phase

An operator model of a mirror as a reflector with a reflectance variable over the aperture is developed on the basis of a Fabry-Perot interferometer. The main characteristics of the interferometer (mirror) are studied in the geometric, diffraction, and modal approximations. The differences in the calculation results obtained using the conventional geometric approximation and the diffraction approach proposed in this study are discussed. It is shown that, when the effective Fresnel numbers are comparable to unity, it is necessary to use the diffraction approximation. The possibility of using an interferometer-based mirror as a selector of transverse laser modes is demonstrated. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mirror with a variable amplitude - phase reflectance. 2. Modelling of a laser resonator with an active output mirror

We present the operator model of the laser resonator with an active output mirror based on the Fabry - Perot interferometer with nonflat (spherical and aspherical) mirrors and an adjustable gap. The results of numerical simulation of a microchip laser with a thermal lens and an active output interferometer-based mirror are given. It is shown that the use of an active interferometer as the output cavity mirror allows one to control the number of transverse modes of laser radiation and its power; in this case, the beam divergence can be reduced by a factor of 1.5 - 2.5. (laser resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THEORY OF DISPERSED FIXED-DELAY INTERFEROMETRY FOR RADIAL VELOCITY EXOPLANET SEARCHES

The dispersed fixed-delay interferometer (DFDI) represents a new instrument concept for high-precision radial velocity (RV) surveys for extrasolar planets. A combination of a Michelson interferometer and a medium-resolution spectrograph, it has the potential for performing multi-object surveys, where most previous RV techniques have been limited to observing only one target at a time. Because of the large sample of extrasolar planets needed to better understand planetary formation, evolution, and prevalence, this new technique represents a logical next step in instrumentation for RV extrasolar planet searches, and has been proven with the single-object Exoplanet Tracker (ET) at Kitt Peak National Observatory, and the multi-object W. M. Keck/MARVELS Exoplanet Tracker at Apache Point Observatory. The development of the ET instruments has necessitated fleshing out a detailed understanding of the physical principles of the DFDI technique. Here we summarize the fundamental theoretical material needed to understand the technique and provide an overview of the physics underlying the instrument's working. We also derive some useful analytical formulae that can be used to estimate the level of various sources of error generic to the technique, such as photon shot noise when using a fiducial reference spectrum, contamination by secondary spectra (e.g., crowded sources, spectroscopic binaries, or moonlight contamination), residual interferometer comb, and reference cross-talk error. Following this, we show that the use of a traditional gas absorption fiducial reference with a DFDI can incur significant systematic errors that must be taken into account at the precision levels required to detect extrasolar planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Formation of NOON states from Fock-state Bose-Einstein condensates

States of the form |N>{sub a}|0>{sub b}+|0>{sub a}|N>{sub b}, where a and b are single-particle states--i.e., NOON states--have been used for predicting violations of local realism (Greenberger-Horne-Zeilinger violations) and are valuable in metrology for precision measurements of phase at the Heisenberg limit. We show theoretically how the use of two Fock-state Bose-Einstein condensates as sources in a modified Mach-Zehnder interferometer can lead to creation of the NOON state in which a and b refer to arms of the interferometer and N is a subset of the total number of particles in the two condensates. The modification of the interferometer involves making ''side'' measurements of a few particles near the sources. These measurements put the remaining particles in a superposition of two phase states, which are converted into NOON states by a beam splitter if the phase states are orthogonal. When they are not orthogonal, a ''feed-forward'' correction circuit is shown to convert them into proper form so that a NOON results. We apply the NOON to the measurement of phase. Here the NOON experiment is equivalent to one in which a large molecule passes through two slits. The NOON components can be recombined in a final beam splitter to show interference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive frequency comb illumination for interferometry in the case of nested two-beam cavities

The homogeneity test of glass plates in a Fizeau interferometer is hampered by the superposition of multiple interference signals coming from the surfaces of the glass plate as well as the empty Fizeau cavity. To evaluate interferograms resulting from such nested cavities, various approaches such as the use of broadband light sources have been applied. In this paper, we propose an adaptive frequency comb interferometer to accomplish the cavity selection. An adjustable Fabry-Perot resonator is used to generate a variable frequency comb that can be matched to the length of the desired cavity. Owing to its flexibility, the number of measurements needed for the homogeneity test can be reduced to four. Furthermore, compared to approaches using a two-beam interferometer as a filter for the broadband light source, the visibility of the fringe system is considerably higher if a Fabry-Perot filter is applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum transport in coupled resonators enclosed synthetic magnetic flux

Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov–Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms. -- Highlights: •The light transport is investigated through ring array of coupled resonators enclosed synthetic magnetic field. •Aharonov–Bohm ring interferometer of arbitrary configuration is investigated. •The half-integer magnetic flux quantum leads to destructive interference and transmission zeros for two-arm at equal length. •Complete transmission is available via tuning synthetic magnetic flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase shifts and wave-packet displacements in neutron interferometry and a nondispersive, nondefocusing phase shifter

A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A metrological large range atomic force microscope with improved performance

A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z-piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x, y, and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v). Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s{sup 2}). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis

We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISAR optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibration mitigation in J-TEXT far-infrared diagnostic systems

Optical structure stability is an important issue for far-infrared (FIR) phase measurements. To ensure good signal quality, influence of vibration should be minimized. Mechanical amelioration and optical optimization can be taken in turn to decrease vibration's influence and ensure acceptable measurement. J-TEXT (Joint Texal Experiment Tokamak, formerly TEXT-U) has two FIR diagnostic systems: a HCN interferometer system for electron density measurement and a three-wave polarimeter-interferometer system (POLARIS) for electron density and Faraday effect measurements. All use phase detection techniques. HCN interferometer system has almost eliminated the influence of vibration after mechanical amelioration and optical optimization. POLARIS also obtained first experimental results after mechanical stability improvements and is expected to further reduce vibration's influence on Faraday angle to 0.1 Degree-Sign after optical optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry

After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of errors in the electron density measurements of a tangential interferometer/polarimeter system during a tokamak discharge

A new method for the comparative verification of electron density measurements obtained with a tangential interferometer and a polarimeter during a discharge is proposed. The possible errors associated with the interferometer and polarimeter are classified by the time required for their identification. Based on the characteristics of the errors, the fringe shift error of the interferometer and the low-frequency noise of the polarimeter were identified and corrected for the JT-60U tangential interferometer/polarimeter system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and characterization of the source grating for visibility improvement of neutron phase imaging with gratings

The fabrication of gratings including metal deposition processes for highly neutron absorbing lines is a critical issue to achieve a good visibility of the grating-based phase imaging system. The source grating for a neutron Talbot-Lau interferometer is an array of Gadolinium (Gd) structures that are generally made by sputtering, photo-lithography, and chemical wet etching. However, it is very challenging to fabricate a Gd structure with sufficient neutron attenuation of approximately more than 20 {mu}m using a conventional metal deposition method because of the slow Gd deposition rate, film stress, high material cost, and so on. In this article, we fabricated the source gratings for neutron Talbot-Lau interferometers by filling the silicon structure with Gadox particles. The new fabrication method allowed us a very stable and efficient way to achieve a much higher Gadox filled structure than a Gd film structure, and is even more suitable for thermal polychromatic neutrons, which are more difficult to stop than cold neutrons. The newly fabricated source gratings were tested at the polychromatic thermal neutron grating interferometer system of HANARO at the Korea Atomic Energy Research Institute, and the visibilities and images from the neutron phase imaging system with the new source gratings were compared with those fabricated by a Gd deposition method.

36 MATERIALS SCIENCE↗

Parallel multiplex laser feedback interferometry

We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaching attometer laser vibrometry

The heterodyne two-beam interferometer has been proven to be the optimal solution for laser-Doppler vibrometry regarding accuracy and signal robustness. The theoretical resolution limit for a two-beam interferometer of laser class 3R (up to 5 mW visible measurement-light) is in the regime of a few femtometer per square-root Hertz and well suited to study vibrations in microstructures. However, some new applications of RF-MEM resonators, nanostructures, and surface-nano-defect detection require resolutions beyond that limit. The resolution depends only on the noise and the sensor sensitivity to specimen displacements. The noise is already defined in nowadays systems by the quantum nature of light for a properly designed optical sensor and more light would lead to an inacceptable influence like heating of a very tiny structure. Thus, noise can only be improved by squeezed-light techniques which require a negligible loss of measurement light which is impossible for almost all technical measurement tasks. Thus, improving the sensitivity is the only possible path which could make attometer laser vibrometry possible. Decreasing the measurement wavelength would increase the sensitivity but would also increase the photon shot noise. In this paper, we discuss an approach to increase the sensitivity by assembling an additional mirror between interferometer and specimen to form an optical cavity. A detailed theoretical analysis of this setup is presented and we derive the resolution limit, discuss the main contributions to the uncertainty budget, and show a first experiment proving the sensitivity amplification of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holographic and time-resolving ability of pulse-pair two-dimensional velocity interferometry

Previous velocity interferometers used at research laboratories for shock physics experiments measured target motion at a point or many points on a line on the target. Recently, a two-dimensional (2d) version (2d-velocity interferometer system for any reflector) has been demonstrated using a pair of ultrashort (3 ps) pulses for illumination, separated by 268 ps. We have discovered new abilities for this instrument, by treating the complex output image as a hologram. For data taken in an out of focus configuration, we can Fourier process to bring narrow features such as cracks into sharp focus, which are otherwise completely blurred. This solves a practical problem when using high numerical aperture optics having narrow depth of field to observe moving surface features such as cracks. Furthermore, theory predicts that the target appearance (position and reflectivity) at two separate moments in time are recorded by the main and conjugate images of the same hologram, and are partially separable during analysis for narrow features. Hence, for the cracks we bring into refocus, we can make a two-frame movie with a subnanosecond frame period. Longer and shorter frame periods are possible with different interferometer delays. Since the megapixel optical detectors we use have superior spatial resolution over electronic beam based framing cameras, this technology could be of great use in studying microscopic three-dimensional-behavior of targets at ultrafast times scales. Demonstrations on shocked silicon are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Mbar shock conditions and isochorically heated aluminum at the MEC end station of the LCLS

Recent experiments performed at the Matter in Extreme Conditions end station (MEC) of the Linac Coherent Light Source (LCLS) have demonstrated the first spectrally resolved measurements of plasmons from isochorically heated aluminum. The experiments have been performed using a seeded 8-keV x-ray laser beam as a pump and probe to both volumetrically heat and scatter x-rays from aluminum. Collective x-ray Thomson scattering spectra show a well-resolved plasmon feature that is down-shifted in energy by 19 eV. In addition, Mbar shock pressures from laser-compressed aluminum foils using Velocity Interferometer System for Any Reflector (VISAR) have been measured. The combination of experiments fully demonstrates the possibility to perform warm dense matter studies at the LCLS with unprecedented accuracy and precision.

INST, MATSCI, PHYS, XFEL↗