At least 595 records · Page 33

Uterine carcinosarcoma: a primer for radiologists

Objective: To provide a modern overview for radiologists of the unique radiological, pathological, and clinical features of uterine carcinosarcoma (UCS). Results: UCS is a unique gynecological malignancy that continues to present diagnostic and therapeutic challenges to the field of oncology. The classification and clinical understanding of this malignancy have evolved in recent years, yielding a modern conceptualization of a neoplastic entity that has been well studied but incompletely understood. As UCS causes a significant proportion of deaths secondary to uterine cancer, developing a familiarity with the imaging and clinical features of this entity is critical. In addition to summarizing the modern understanding of this tumor variant, an overview of the common imaging features of UCS will be presented. The role of radiological staging, imaging findings on presentation and follow-up imaging, and modern treatment paradigms will be discussed. Lastly, the current treatment paradigms and surveillance recommendations for UCS will be summarized. Conclusion: Knowledge of the modern understanding of uterine carcinosarcoma, including its relevant imaging and clinical features, is critical for radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of transgender patients: expected findings and complications of gender reassignment therapy

Objectives: Gender dysphoria is defined as a conflict between the biological gender and the gender with which the person identifies. Gender reassignment therapy can alter external sexual features to resemble those of the desired gender and are broadly classified into two types, female to male (FTM) and male to female (MTF). In this paper we describe expected findings and complications of gender reassignment therapy. Methods: Collaborative multi-institutional project supported by Ovarian and Uterine Cancer Disease Focused panel of Society of Abdominal Radiology. Results: Gender dysphoria is defined as a conflict between the biological gender and the gender with which the person identifies. Gender reassignment therapy can alter external sexual features to resemble those of the desired gender and are broadly classified into two types, female to male (FTM) and male to female (MTF). These therapies include hormonal treatment as well as surgical procedures. FTM genital reconstructive therapy includes creation of a neophallus, which can be achieved by metoidioplasty or phalloplasty with mastectomy, along with testosterone administration. MTF gender reassignment surgery includes complete removal of external genitalia with penectomy and orchiectomy, with vaginoplasty, clitoroplasty, labiaplasty, and breast augmentation along with estrogen supplements. Conclusion: Surgical techniques alter the standard anatomy and make imaging interpretation challenging if radiologists are unfamiliar with expected post-operative appearances. It is important to recognize the complications related to surgical and non-surgical treatment of gender dysphoria to avoid interpretation errors. Furthermore, increasing the prevalence of transgender patients requires increased sensitivity when interpreting imaging studies to reduce the potential for misdiagnoses in reporting due to frequently incomplete available clinical history.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The yield and patient factors associated with CT colonography C-RADS results in a non-screening patient population

Objectives: To determine the proportion of diagnostic computed tomography colonography (CTC) Reporting and Data System (C-RADS) categories in a non-screening population, and which patient factors are associated with a positive CTC (C2–4), a non-diagnostic CTC (C0), and potentially relevant extracolonic findings (ECF, E3–4). Methods: Diagnostic CTCs performed at a single academic center from 2017 to 2018 were retrospectively reviewed. For each examination, the indications, age, sex, admission status, and C-RADS categories were recorded. Multivariate logistic regression was performed of patient demographic factors and clinical indications, with adjusted odds ratios (OR) and 95% confidence intervals. Results: 1373 CTCs were included. The mean age was 66.4 ± 13 years (range 24–97). There were 782 women and 75 inpatients. The number of CTCs reported as C0–C4 were 194/1373 (14.1%), 970/1373 (70.6%), 77/1373 (5.6%), 86/1373 (6.3%), and 46/1373 (3.4%), respectively, and 134/1373 (9.8%), 960/1373 (69.9%), 173/1373 (12.6%), and 106/1373 (7.7%) CTCs were reported as E1–4, respectively. Factors that demonstrated the strongest associations were as follows: with C2–4, age groups 50–79 (OR 2.8, 95% confidence interval 1.4–6.1), 80–89 (6.2, 2.9–14.5) and ≥ 90 (7.6, 2.0–29.1), and inpatients (3.4, 1.8–6.4); with C0, age groups 50–79 (5.9, 2.2–24.4), 80–89 (9.8, 3.4–41.8), and ≥ 90 (22.5, 5.8–113.0), incomplete colonoscopy (3.2, 2.0–5.1) and melena or gastrointestinal bleeding (4.1, 1.8–9.4); and with E3–4, age groups 50–79 (1.6, 1.0–2.9), 80–89 (2.0, 1.1–3.9), and ≥ 90 (3.2, 1.2–8.8), and inpatients (2.3, 1.3–3.9). Conclusion: Older age is increasingly associated with a positive test, a non-diagnostic test and potentially relevant ECF. Inpatients are also associated with positive tests and E3–4 findings. Symptoms are not strongly associated with a positive CTC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Therapeutic Results of Computed Tomography-Guided Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma: Results of 265 Tumors in 79 Patients

Purpose. To elucidate the local therapeutic results of computed tomography (CT)-guided transcatheter arterial chemoembolization (TACE) as initial treatment for hepatocellular carcinoma (HCC), and to verify factors which affect local therapeutic results. Methods. From 1992 to 2002, 265 tumors of 79 HCC patients were treated by 139 sessions of CT-guided TACE as initial treatment. Among these 265 tumors, 182 constituted multiple new lesions, and the remaining 83 tumors were single new lesions. Local recurrence was retrospectively ascertained on follow-up CT images obtained after TACE. Results. The overall local recurrence-free rates (LR-FRs) after a single TACE session at 6, 12, and 36 months were 67%, 49%, and 28%; those of the single new lesions were 80%, 66%, and 32%; and those of tumors with complete lipiodol accumulation were 82%, 68%, and 41%, respectively. LR-FRs of tumors of the single new lesions, and those of tumors with complete lipiodol accumulation, were significantly higher than the LR-FRs of multiple new lesions and tumors with incomplete lipiodol accumulation, respectively. For single new lesions {<=}4 cm and the tumors that were one of multiple new lesions, there were no significant differences in the LR-FRs regarding the number of TACE sessions on the basis of patient, tumor location, or tumor size. Conclusion. Local therapeutic results of single new lesions were better than those of multiple new lesions, and the local therapeutic effect of TACE was not affected by the number of treatments on the basis of patient, tumor location, or tumor size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infarction of Uterine Fibroids After Embolization: Relationship Between Postprocedural Enhanced MRI Findings and Long-Term Clinical Outcomes

Purpose. To retrospectively evaluate the relationship between the degree of infarction of uterine fibroids on enhanced MRI after embolization and long-term clinical outcomes. Methods. During 92 months, 290 consecutive patients with symptomatic uterine fibroids were treated with embolization; 221 who underwent enhanced MRI before embolization and 1 week after embolization were included in this study. The infarction rates of all fibroid tissue were assessed using enhanced MRI after embolization. Patients were divided into three groups according to the infarction rates: group A (100% infarction, n 142), group B (90-99% infarction, n = 74), group C (<90% infarction, n = 5). The cumulative rates of clinical outcomes were compared among groups using the Kaplan-Meier limited method. Results. Group A had a significantly higher rate of symptom control than groups B and C. The cumulative rates of symptom control at 5 years were 93%, 71%, and 60% in groups A, B, and C, respectively. Group A had a significantly lower rate of gynecologic intervention after embolization than groups B and C. The cumulative rates of additional gynecologic intervention at 5 years were 3%, 15%, and 20% in groups A, B, and C, respectively. Conclusions. The degree of infarction of uterine fibroids after embolization on enhanced MRI was related to long-term clinical outcomes. Complete infarction of all fibroid tissue can induce a higher rate of symptom control, with a lower rate of additional gynecologic intervention in the long term compared with incomplete infarction of fibroid tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostatic Artery Embolization as a Primary Treatment for Benign Prostatic Hyperplasia: Preliminary Results in Two Patients

Symptomatic benign prostatic hyperplasia (BPH) typically occurs in the sixth and seventh decades, and the most frequent obstructive urinary symptoms are hesitancy, decreased urinary stream, sensation of incomplete emptying, nocturia, frequency, and urgency. Various medications, specifically 5-{alpha}-reductase inhibitors and selective {alpha}-blockers, can decrease the severity of the symptoms secondary to BPH, but prostatectomy is still considered to be the traditional method of management. We report the preliminary results for two patients with acute urinary retention due to BPH, successfully treated by prostate artery embolization (PAE). The patients were investigated using the International Prostate Symptom Score, by digital rectal examination, urodynamic testing, prostate biopsy, transrectal ultrasound (US), and magnetic resonance imaging (MRI). Uroflowmetry and postvoid residual urine volume complemented the investigation at 30, 90, and 180 days after PAE. The procedure was performed under local anesthesia; embolization of the prostate arteries was performed with a microcatheter and 300- to 500-{mu}m microspheres using complete stasis as the end point. One patient was subjected to bilateral PAE and the other to unilateral PAE; they urinated spontaneously after removal of the urethral catheter, 15 and 10 days after the procedure, respectively. At 6-month follow-up, US and MRI revealed a prostate reduction of 39.7% and 47.8%, respectively, for the bilateral PAE and 25.5 and 27.8%, respectively, for the patient submitted to unilateral PAE. The early results, at 6-month follow-up, for the two patients with BPH show a promising potential alternative for treatment with PAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Randomized Comparison of Chemoembolization with Doxorubicin-Eluting Beads and Bland Embolization with BeadBlock for Hepatocellular Carcinoma

The purpose of this study was to evaluate the added role of a chemotherapeutic in transarterial chemoembolization (TACE) of intermediate-stage hepatocellular carcinoma (HCC). The issue is of major importance since, as suggested by recent evidence, hypoxia or incomplete devascularization of the tumor is a potent stimulator of angiogenesis, and there are not many papers supplying level one evidence confirming the value of a chemotherapeutic. The hypothesis was that since drug-eluting bead (DEB)-TACE is standardized and reproducible, a comparison with bland TACE can readily reveal the potential value of the chemotherapeutic. Two groups were randomized in this prospective study: group A (n = 41) was treated with doxorubicin DEB-TACE, and group B (n = 43) with bland embolization. Patients were randomized for tumor diameter. Patients were embolized at set time intervals (2 months), with a maximum of three embolizations. Tumor response was evaluated using the EASL criteria and {alpha}-fetoprotein levels. At 6 months a complete response was seen in 11 patients (26.8%) in the DEB-TACE group and in 6 patients (14%) in the bland embolization group; a partial response was achieved in 19 patients (46.3%) and 18 (41.9%) patients in the DEB-TACE and bland embolization groups, respectively. Recurrences at 9 and 12 months were higher for bland embolization (78.3% vs. 45.7%) at 12 months. Time to progression (TTP) was longer for the DEB-TACE group (42.4 {+-} 9.5 and 36.2 {+-} 9.0 weeks), at a statistically significant level (p = 0.008). In conclusion, DEB-TACE presents a better local response, fewer recurrences, and a longer TTP than bland embolization with BeadBlock. However, survival benefit and bland embolization with smaller particles must be addressed in future papers to better assess the clinical value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Tumors Treated With Percutaneous Radiofrequency Ablation: Computed Tomography Imaging Follow-Up

Purpose: To describe the morphologic evolution of lung tumors treated with radiofrequency ablation (RFA) by way of computed tomography (CT) images and to investigate patterns of incomplete RFA at the site of ablation. Materials and Methods: One hundred eighty-nine patients with 350 lung tumors treated with RFA underwent CT imaging at 2, 4, 6, and 12 months. CT findings were interpreted separately by two reviewers with consensus. Five different radiologic patterns were predefined: fibrosis, cavitation, nodule, atelectasis, and disappearance. The appearance of the treated area was evaluated at each follow-up CT using the predefined patterns. Results: At 1 year after treatment, the most common evolutions were fibrosis (50.5%) or nodules (44.8%). Differences were noted depending on the initial size of the tumor, with fibrosis occurring more frequently for tumors <2 cm (58.6% vs. 22.9%, P = 1 Multiplication-Sign 10{sup -5}). Cavitation and atelectasis were less frequent patterns (2.4% and 1.4%, respectively, at 1 year). Tumor location (intraparenchymatous, with pleural contact <50% or >50%) was not significantly correlated with follow-up image pattern. Local tumor progressions were observed with each type of evolution. At 1 year, 12 local recurrences were noted: 2 cavitations, which represented 40% of the cavitations noted at 1 year; 2 fibroses (1.9%); 7 nodules (7.4%); and 1 atelectasis (33.3%). Conclusion: After RFA of lung tumors, follow-up CT scans show that the shape of the treatment zone can evolve in five different patterns. None of these patterns, however, can confirm the absence of further local tumor progression at subsequent follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Ablation of High Intensity Focused Ultrasound with Microbubbles: An Experimental Study on Rabbit Hepatic VX2 Tumors

Purpose: This study was designed to assess the enhanced effect of high intensity focused ultrasound (HIFU) ablation with microbubbles on rabbit hepatic VX2 tumors and to compare the detection sensitivity of CEUS and CECT to determine the residual viable tissue after ablation of HIFU. Methods: Forty rabbits with hepatic VX2 tumors were randomly separated into two groups (20 animals per group) before HIFU ablation. A bolus of 0.2 mL of saline or a microbubble-based ultrasound (US) contrast agent was injected intravenously to group I rabbits and group II rabbits, respectively. The HIFU ablation procedure was started 15 s after the injection. Tumors were examined with grayscale contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) immediately before and after HIFU ablation. Histopathologic assessment was performed immediately after treatment imaging. Results: Before ablation, intense contrast enhancement during arterial phase was observed at the whole tumors or the periphery of the tumors by CEUS and CECT. Lower HIFU energy was used in group II than in group I (P < 0.001). Histopathologic assessment revealed local residual viable tumor tissues due to incomplete ablation in 47.4% (9/19) of tumors in group I and 10% (2/20) of tumors in group II (P < 0.05). The concordance rate of CEUS (90.9%) with histopathology on residual tumor detection was higher than that of CECT (27.3%, P < 0.05). Conclusions: Introduction of the microbubble agent enhances HIFU therapeutic efficacy. CEUS proves to have high sensitivity in assessment of residual viable rabbit VX2 tumor after HIFU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Visceral Aneurysm Using Multilayer Stent: Two-Year Follow-Up Results in Five Consecutive Patients

Purpose: The present study was performed to analyze the midterm results (five consecutive patients, 2-year follow-up) of the endovascular management of visceral artery aneurysms using the Cardiatis Multilayer Flow Modulator (CMFM) (Cardiatis, Isnes, Belgium), a self-expandable stent. Materials and Methods: From August 2009 to January 2011, we implanted five CMFMs in five patients (all men; mean age 73 years) to treat two common hepatic artery aneurysms, one celiac trunk aneurysm, one splenic artery aneurysm, and one superior mesenteric artery aneurysm (diameter 25-81 mm). The primary end point was technical success. The secondary end point was stent patency, absence of aneurysm rupture or reperfusion, and shrinking of the sac at 6-, 12-, and 24-month follow-up using computed tomography angiography. Follow-up ranged from 24 to 48 months (mean 31.2). Results: Technical success was achieved in all patients. Complete exclusion of the aneurysm with sac shrinking was achieved in two patients. Two stents became occluded at 6- and 24-month follow-up, respectively; both patients were asymptomatic and were not retreated. One patient developed sac reperfusion due to incomplete aneurysm exclusion. Conclusion: Long-term results in a wider population are needed to validate the effectiveness of the CMFM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 Cases

PurposeThis study was designed to assess feasibility of US-CT/MRI fusion-guided ablation in liver tumors undetectable with US.MethodsFrom 2002 to 2012, 295 tumors (162 HCCs and 133 metastases; mean diameter 1.3 ± 0.6 cm, range 0.5–2.5 cm) detectable on contrast-enhanced CT/MRI, but completely undetectable with unenhanced US and either totally undetectable or incompletely conspicuous with contrast-enhanced US (CEUS), were treated in 215 sessions using either internally cooled radiofrequency or microwave with standard ablation protocols, guided by an image fusion system (Virtual Navigation System, Esaote S.p.A., Genova, Italy) that combines US with CT/ MRI images. Correct targeting and successful ablation of tumor were verified after 24 hours with CT or MRI.ResultsA total of 282 of 295 (95.6 %) tumors were correctly targeted with successful ablation achieved in 266 of 295 (90.2 %). Sixteen of 295 (5.4 %) tumors were correctly targeted, but unsuccessfully ablated, and 13 of 295 (4.4 %) tumors were unsuccessfully ablated due to inaccurate targeting. There were no perioperative deaths. Major complications were observed in 2 of the 215 treatments sessions (0.9 %).ConclusionsReal-time virtual navigation system with US-CT/MRI fusion imaging is precise for targeting and achieving successful ablation of target tumors undetectable with US alone. Therefore, a larger population could benefit from ultrasound guided ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Ruptured Vertebral Artery Dissecting Aneurysms Distal to the Posterior Inferior Cerebellar Artery: Stenting or Trapping?

PurposeThe treatment of ruptured vertebral artery dissecting aneurysms (VADAs) continues to be controversial. Our goal was to evaluate the safety, efficacy, and long-term outcomes of internal trapping and stent-assisted coiling (SAC) for ruptured VADAs distal to the posterior inferior cerebellar artery (supra-PICA VADAs), which is the most common subset.MethodsA retrospective review was conducted of 39 consecutive ruptured supra-PICA VADAs treated with internal trapping (n = 20) or with SAC (n = 19) at our institution. The clinical and angiographic data were retrospectively compared.ResultsThe immediate total occlusion rate of the VADAs was 80 % in the trapping group, which improved to 88.9 % at the follow-ups (45 months on average). Unwanted occlusions of the posterior inferior cerebellar artery (PICA) were detected in three trapped cases. Incomplete obliteration of the VADA or unwanted occlusions of the PICA were detected primarily in the VADAs closest to the PICA. In the stenting group, the immediate total occlusion rate was 47.4 %, which improved to 100 % at the follow-ups (39 months on average). The immediate total occlusion rate of the VADAs was higher in the trapping group (p < 0.05), but the later total occlusion was slightly higher in the stenting group (p > 0.05).ConclusionsOur preliminary results showed that internal trapping and stent-assisted coiling are both technically feasible for treating ruptured supra-PICA VADAs. Although not statistically significant, procedural related complications occurred more frequently in the trapping group. When the VADAs are close to the PICA, we suggest that the lesions should be treated using SAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Lung Thermal Ablation of Non-surgical Clinical N0 Non-small Cell Lung Cancer: Results of Eight Years’ Experience in 87 Patients from Two Centers

PurposeTo evaluate the survival outcomes of percutaneous thermal ablation (RFA + microwaves) for patients presenting N0 non-small-cell lung cancer (NSCLC) ineligible for surgery.Materials and MethodsEighty-seven patients from two comprehensive cancer centers were included. Eighty-two patients were treated with RFA electrodes and five with microwave antenna. Overall survival (OS) and disease-free survival (DFS) were estimated and predictive factors of local tumor progression, OS and DFS identified and compared by univariate and multivariate analysesResultsMedian follow-up was 30.5 months (interquartile range 16.7–51) and tumor size was 21 mm (range 10–54 mm). Treatment was incomplete for 14 patients with a local tumor progression of 11.5, 18.3, and 21.1 % at 1, 2, and 3 years, respectively. Two patients presented with neurological (grade III or IV) complications, and one died of respiratory and multivisceral failure as a result of the procedure at 29 days. In univariate analysis, increasing tumor size (P = 0.003) was the only predictive factor related to risk of local tumor progression. 5-year OS and DFS were 58.1 and 27.9 %, respectively. Sex (P = 0.044), pathology (P = 0.032), and tumor size >2 cm (P = 0.046) were prognostic factors for DFS. In multivariate analysis, pathology (P = 0.033) and tumor size >2 cm (P = 0.032) were independent prognostic factors for DFS.ConclusionsOversized and overlapping ablation of N0 NSCLC was well tolerated, effective, with few local tumor progressions, even over long-term follow-up. Increasing tumor size was the main prognostic factor linked to OS, DFS, and local tumor progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗