Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Potential of Attosecond Coherent Diffractive Imaging

Attosecond science has been transforming our understanding of electron dynamics in atoms, molecules, and solids. However, to date almost all of the attoscience experiments have been based on spectroscopic measurements because attosecond pulses have intrinsically very broad spectra due to the uncertainty principle and are incompatible with conventional imaging systems. In this paper we report an important advance towards achieving attosecond coherent diffractive imaging. Using simulated attosecond pulses, we simultaneously reconstruct the spectrum, 17 probes, and 17 spectral images of extended objects from a set of ptychographic diffraction patterns. We further confirm the principle and feasibility of this method by successfully performing a ptychographic coherent diffractive imaging experiment using a light-emitting diode with a broad spectrum. We believe this work clears the way to an unexplored domain of attosecond imaging science, which could have a far-reaching impact across different disciplines.

36 MATERIALS SCIENCE↗

Imaging heliospheric shocks using energetic neutral atoms

In order to explore the feasibility of energetic neutral atom (ENA) imaging of shock-associated energetic proton populations in the heliosphere, computer-simulated ENA images have been generated based on Voyager 1/2 energetic ion measurements. One favorable vantage point for ENA shock imaging is from the Cassini spacecraft's orbit around Saturn at 10 AU. These images, calibrated relative to the measured shock-associated proton fluxes, yield an absolute estimate of ENA fluxes which indicates that useful heliospheric ENA imaging can be accomplished with present technology.

Roelof, E. C.↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic Image Reconstruction for the Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

For the past three years, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly in order to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager is under construction. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies. This report documents the development of the iterative reconstruction code used to perform tomographic image reconstruction, the imager response calculation used by the reconstruction code, and the results of reconstructions of simulated tomographic imaging measurements for the prototype imager design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DeepZipper. II. Searching for Lensed Supernovae in Dark Energy Survey Data with Deep Learning

Gravitationally lensed supernovae (LSNe) are important probes of cosmic expansion, but they remain rare and difficult to find. Current cosmic surveys likely contain 5–10 LSNe in total while next-generation experiments are expected to contain several hundred to a few thousand of these systems. We search for these systems in observed Dark Energy Survey (DES) five year SN fields—10 3 sq. deg. regions of sky imaged in the griz bands approximately every six nights over five years. To perform the search, we utilize the DeepZipper approach: a multi-branch deep learning architecture trained on image-level simulations of LSNe that simultaneously learns spatial and temporal relationships from time series of images. We find that our method obtains an LSN recall of 61.13% and a false-positive rate of 0.02% on the DES SN field data. DeepZipper selected 2245 candidates from a magnitude-limited (m i < 22.5) catalog of 3,459,186 systems. We employ human visual inspection to review systems selected by the network and find three candidate LSNe in the DES SN fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Onboard utilization of ground control points for image correction. Volume 2: Analysis and simulation results

An approach to remote sensing that meets future mission requirements was investigated. The deterministic acquisition of data and the rapid correction of data for radiometric effects and image distortions are the most critical limitations of remote sensing. The following topics are discussed: onboard image correction systems, GCP navigation system simulation, GCP analysis, and image correction analysis measurement.

Source record↗

WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging.

60 APPLIED LIFE SCIENCES↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Massive star-forming host galaxies of quasars on Sloan digital sky survey stripe 82

The stellar properties of about 800 galaxies hosting optically luminous, unobscured quasars at z < 0.6 are analyzed. Deep co-added Sloan Digital Sky Survey (SDSS) images of the quasars on Stripe 82 are decomposed into nucleus and host galaxy using point spread function and Sérsic models. The systematic errors in the measured galaxy absolute magnitudes and colors are estimated to be less than 0.5 mag and 0.1 mag, respectively, with simulated quasar images. The effect of quasar light scattered by the interstellar medium is also carefully addressed. The measured quasar-to-galaxy ratio in total flux decreases toward longer wavelengths, from ∼8 in the u band to ∼1 in the i and z bands. We find that the SDSS quasars are hosted exclusively by massive galaxies (stellar mass M {sub star} > 10{sup 10} M {sub ☉}), which is consistent with previous results for less luminous narrow-line (obscured) active galactic nuclei (AGNs). The quasar hosts are very blue and almost absent on the red sequence, showing stark contrast to the color-magnitude distribution of normal galaxies. The fact that more powerful AGNs reside in galaxies with higher star-formation efficiency may indicate that negative AGN feedback, if it exists, is not concurrent with the most luminous phase of AGNs. We also find positive correlation between the mass of supermassive black holes (SMBHs; M {sub BH}) and host stellar mass, but the M {sub BH}-M {sub star} relation is offset toward large M {sub BH} or small M {sub star} compared to the local relation. While this could indicate that SMBHs grow earlier than do their host galaxies, such an argument is not conclusive, as the effect may be dominated by observational biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning enhanced super-resolution x-ray fluorescence microscopy by a dual-branch network

X-ray fluorescence (XRF) microscopy is a powerful technique for quantifying the distribution of elements in complex materials, which makes it a crucial imaging technique across a wide range of disciplines in physical and biological sciences, including chemistry, materials science, microbiology, and geosciences. However, as a scanning microscopy technique, the spatial resolution of XRF imaging is inherently constrained by the x-ray probe profile and scanning step size. Here we propose a dual-branch machine learning (ML) model, which can extract scale-variant features and bypass abundant low-frequency information separately, to enhance the spatial resolution of the XRF images by mitigating the effects of blurring from the probe profile. The model is trained by simulated natural images, and a two-stage training strategy is used to overcome the domain gap between the natural images and experimental data. The tomography reconstruction from enhanced XRF projections shows an improvement in resolution by a scale factor of four and reveals distinct internal features invisible in low-resolution XRF within a battery sample. This study offers a promising approach for obtaining high-resolution XRF imaging from its low-resolution version, paving the way for future investigations in a broader range of disciplines and materials.

36 MATERIALS SCIENCE↗

Galileo Press Conference from JPL

This two-tape Jet Propulsion Laboratory (JPL) video production presents a Dec. 8, 1992 press conference held at JPL to discuss the final Galileo spacecraft encounter with Earth before beginning its journey to Jupiter. The main theme of the conference was centered on the significance of the 2nd and final Earth/Moon flyby as being the spacecraft's last planetary encounter in the solar system before reaching Jupiter, as well as final flight preparations prior to its final journey. Each person of the five member panel was introduced by Robert MacMillan (JPL Public Information Mgr.) before giving brief presentations including slides and viewgraphs covering their area of expertise regarding Galileo's current status and future plans. After the presentations, the media was given an opportunity to ask questions of the panel regarding the mission. Mr. Wesley Huntress (Dir. of Solar System Exploration (NASA)), William J. ONeill (Galileo Project Manager), Neal E. Ausman, Jr. (Galileo Mission Director), Dr. Torrence V. Johnson (Galileo Project Scientist) and Dr. Ronald Greeley (Member, Imaging Team, Colorado St. Univ.) made up the panel and discussed topics including: Galileo's interplanetary trajectory; project status and performance review; instrument calibration activities; mission timelines; lunar observation and imaging; and general lunar science. Also included in the last three minutes of the video are simulations and images of the 2nd Galileo/Moon encounter.

Source record↗

Solar Flare Physics

We have continued our previous efforts in studies of fourier imaging methods applied to hard X-ray flares. We have performed physical and theoretical analysis of rotating collimator grids submitted to GSFC(Goddard Space Flight Center) for the High Energy Solar Spectroscopic Imager (HESSI). We have produced simulation algorithms which are currently being used to test imaging software and hardware for HESSI. We have developed Maximum-Entropy, Maximum-Likelihood, and "CLEAN" methods for reconstructing HESSI images from count-rate profiles. This work is expected to continue through the launch of HESSI in July, 2000. Section 1 shows a poster presentation "Image Reconstruction from HESSI Photon Lists" at the Solar Physics Division Meeting, June 1998; Section 2 shows the text and viewgraphs prepared for "Imaging Simulations" at HESSI's Preliminary Design Review on July 30, 1998.

Schmahl, Edward J.↗

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗

Enhanced material identification via momentum-integrated muon scattering tomography

Cosmic ray muons, originating from interactions in the upper atmosphere, possess high energy and unique penetrative capabilities suitable for non-traditional radiographic inspection. This study explores their application in various fields such as nuclear fuel cask monitoring, nuclear reactor imaging, and archaeology, leveraging the principle of multiple Coulomb scattering for imaging dense materials. While muon scattering tomography has shown promise, accurately measuring muon momentum remains challenging. This research introduces the Momentum Integrated Point-of-Closest Approach (mPoCA) algorithm, integrating muon momentum data into the traditional Point-of-Closest Approach (PoCA) framework. Utilizing the Cherenkov muon spectrometer, renowned for precise muon momentum estimation, the mPoCA algorithm offers a novel imaging approach. Simulations conducted with GEANT4 evaluate the mPoCA algorithm’s performance against the standard PoCA method, demonstrating superior image resolution and enhanced material identification capabilities, particularly in distinguishing materials like uranium and lead. These findings underscore the potential of the mPoCA algorithm for advancing muon scattering tomography applications.

36 MATERIALS SCIENCE↗

THE DETECTION AND STATISTICS OF GIANT ARCS BEHIND CLASH CLUSTERS

We developed an algorithm to find and characterize gravitationally lensed galaxies (arcs) to perform a comparison of the observed and simulated arc abundance. Observations are from the Cluster Lensing And Supernova survey with Hubble (CLASH). Simulated CLASH images are created using the MOKA package and also clusters selected from the high-resolution, hydrodynamical simulations, MUSIC, over the same mass and redshift range as the CLASH sample. The algorithm's arc elongation accuracy, completeness, and false positive rate are determined and used to compute an estimate of the true arc abundance. We derive a lensing efficiency of 4 ± 1 arcs (with length ≥6″ and length-to-width ratio ≥7) per cluster for the X-ray-selected CLASH sample, 4 ± 1 arcs per cluster for the MOKA-simulated sample, and 3 ± 1 arcs per cluster for the MUSIC-simulated sample. The observed and simulated arc statistics are in full agreement. We measure the photometric redshifts of all detected arcs and find a median redshift z{sub s} = 1.9 with 33% of the detected arcs having z{sub s} > 3. We find that the arc abundance does not depend strongly on the source redshift distribution but is sensitive to the mass distribution of the dark matter halos (e.g., the c–M relation). Our results show that consistency between the observed and simulated distributions of lensed arc sizes and axial ratios can be achieved by using cluster-lensing simulations that are carefully matched to the selection criteria used in the observations.

79 ASTRONOMY AND ASTROPHYSICS↗