Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Strong field gravitational lensing by a charged Galileon black hole

Strong field gravitational lensings are dramatically disparate from those in the weak field by representing relativistic images due to light winds one to infinity loops around a lens before escaping. We study such a lensing caused by a charged Galileon black hole, which is expected to have possibility to evade no-hair theorem. We calculate the angular separations and time delays between different relativistic images of the charged Galileon black hole. All these observables can potentially be used to discriminate a charged Galileon black hole from others. We estimate the magnitudes of these observables for the closest supermassive black hole Sgr A*. The strong field lensing observables of the charged Galileon black hole can be close to those of a tidal Reissner-Nordström black hole or those of a Reissner-Nordström black hole. It will be helpful to distinguish these black holes if we can separate the outermost relativistic images and determine their angular separation, brightness difference and time delay, although it requires techniques beyond the current limit.

79 ASTRONOMY AND ASTROPHYSICS↗

Stable Lobed Mixer With Combustion Demonstrated and Measured

The NASA Lewis Research Center collaborated with the Massachusetts Institute of Technology (MIT) on an experiment to study the use of lobed mixers to improve the fuel-air mixing process and increase combustion intensity in combustors with minimal pressure loss. This experiment is the first known stable combusting flow studied for this device, and the data show a much faster and much more uniform combustion process than for flat-plate mixers. Several potential benefits may be realized from this study in future combustors, including a reduction in NO_x emissions because of the more uniform temperature distribution. The experiment was done in Lewis' Planar Reacting Shear Layer facility, which was adapted to accept a lobed mixer in addition to the original planar tip. A graduate student at MIT provided the mixer design concept, and Lewis provided the engineering, operations, and research expertise. The experiment used hydrogen-nitrogen mixtures to react with vitiated hot air at 920 K. A flow speed of about 120 m/sec and a speed ratio of 0.5 were used. Flow diagnostics consisted of traversing fine-wire thermocouples and pitot probes for flow mapping. Supplementary fluorescence images were taken with a charged coupled device (CCD) camera to show the location and temporal behavior of the reaction zone. The data showed that the lobed mixer consumed the reactants between 3 to 10 times faster than a corresponding planar shear layer. The figure shows the dramatic difference in the measured temperature distribution with and without the lobed mixer. The increased mixing rate was due to a larger interfacial area as well as to the secondary flow from the streamwise vortices off the tips of the lobes. In addition, the fluorescence images showed that the lobes acted as flame stabilizers.

Source record↗

Nonlinear Nano‐Imaging of Interlayer Coupling in 2D Graphene‐Semiconductor Heterostructures

The emergent electronic, spin, and other quantum properties of 2D heterostructures of graphene and transition metal dichalcogenides are controlled by the underlying interlayer coupling and associated charge and energy transfer dynamics. However, these processes are sensitive to interlayer distance and crystallographic orientation, which are in turn affected by defects, grain boundaries, or other nanoscale heterogeneities. This obfuscates the distinction between interlayer charge and energy transfer. Here, nanoscale imaging in coherent four‐wave mixing (FWM) and incoherent two‐photon photoluminescence (2PPL) is combined with a tip distance‐dependent coupled rate equation model to resolve the underlying intra‐ and inter‐layer dynamics while avoiding the influence of structural heterogeneities in mono‐ to multi‐layer graphene/WSe 2 heterostructures. With selective insertion of hBN spacer layers, it is shown that energy, as opposed to charge transfer, dominates the interlayer‐coupled optical response. From the distinct nano‐FWM and ‐2PPL tip‐sample distance‐dependent modification of interlayer and intralayer relaxation by tip‐induced enhancement and quenching, an interlayer energy transfer time of τ ET ≈ ( 0 . 35 − 0.15 + 0.65 ) $\tau _{\rm ET} \approx (0.35^{+0.65}_{-0.15})$ ps consistent with recent reports is derived. As a local probe technique, this approach highlights the ability to determine intrinsic sample properties even in the presence of large sample heterogeneity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantitative Analysis of Ultralow-Density Materials Using Laboratory-Based Quasi-Monochromatic Radiography

The measurement of the density of materials, especially ultralow-density foams, is difficult in that the measurement must be precise and localizable. The density of the material is often governed by its cellular (i.e., porous) structure, and many techniques exist to create that structure. Often, the cellular structure can vary from one location within the material to another, and when at low densities (i.e., densities lower than ~500 mg/cm 3 ), it can vary due to shrinkage during syneresis, collapse under the weight of gravity, or gas/water vapor uptake. Quantifying this variation is important for a variety of applications, especially when used in plasma physics targets. Knowing the density and its variation across the sample is critical for experimental results to be accurately predicted by physics calculations and for modeling the results of the physics targets. The use of quasi-monochromatic radiography provides a means to image the two-dimensional (2-D) distribution of density variation within silica aerogel materials and to quantitatively measure that variation from sample to sample and lot to lot. For this work, two batches of silica aerogels with targeted densities of ~20 mg/cm 3 were created, one batch at Lawrence Livermore National Laboratory, and the other batch at Los Alamos National Laboratory. Outlined here is a quasi-monochromatic radiography system using various X-ray sources coupled to a doubly curved crystal optic and X-ray charge-coupled device camera to image and characterize these materials. It was found that measuring the density both gravimetrically and using quasi-monochromatic radiography were statistically identical, although the two batches were found to be slightly higher than their targeted density due to shrinkage. The radiography system also provided 2-D information as to the aerogel quality, i.e., presence of voids, chipped material, or inclusions.

36 MATERIALS SCIENCE↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Sub-GeV dark matter and neutrino searches with Skipper-CCDs: status and prospects

Thick fully-depleted charge-coupled devices (CCDs) with high-resistivity silicon are used in a wide range of scientific applications, from particle detection to astronomical imaging. Their low noise and high charge collection efficiency allow us to reach unprecedented sensitivity to physical processes with low-energy transfers. The newly-developed Skipper-CCD enhances this sensitivity by reducing the read-out noise reaching a sub-electron resolution. In this work, we summarize the fundamentals of the skipper-CCD operation and the prospects for both sub-GeV dark-matter searches and the detection of coherent elastic neutrino-nucleus scattering. A brief discussion of the challenges associated with the construction of the foreseen detectors with multi-kilogram target mass is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The detection of soft X-rays with charged coupled detectors

The characteristics of an ideal soft X-ray imaging detector are enumerated. Of recent technical developments the CCD or charge coupled device goes furthest to meeting these requirements. Several properties of CCDs are described with reference to experimental work and their application to practical instruments is reviewed.

Burstein, P.↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

07 ISOTOPE AND RADIATION SOURCES↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Portable Airborne Laser System Measures Forest-Canopy Height

(PALS) is a combination of laser ranging, video imaging, positioning, and data-processing subsystems designed for measuring the heights of forest canopies along linear transects from tens to thousands of kilometers long. Unlike prior laser ranging systems designed to serve the same purpose, the PALS is not restricted to use aboard a single aircraft of a specific type: the PALS fits into two large suitcases that can be carried to any convenient location, and the PALS can be installed in almost any local aircraft for hire, thereby making it possible to sample remote forests at relatively low cost. The initial cost and the cost of repairing the PALS are also lower because the PALS hardware consists mostly of commercial off-the-shelf (COTS) units that can easily be replaced in the field. The COTS units include a laser ranging transceiver, a charge-coupled-device camera that images the laser-illuminated targets, a differential Global Positioning System (dGPS) receiver capable of operation within the Wide Area Augmentation System, a video titler, a video cassette recorder (VCR), and a laptop computer equipped with two serial ports. The VCR and computer are powered by batteries; the other units are powered at 12 VDC from the 28-VDC aircraft power system via a low-pass filter and a voltage converter. The dGPS receiver feeds location and time data, at an update rate of 0.5 Hz, to the video titler and the computer. The laser ranging transceiver, operating at a sampling rate of 2 kHz, feeds its serial range and amplitude data stream to the computer. The analog video signal from the CCD camera is fed into the video titler wherein the signal is annotated with position and time information. The titler then forwards the annotated signal to the VCR for recording on 8-mm tapes. The dGPS and laser range and amplitude serial data streams are processed by software that displays the laser trace and the dGPS information as they are fed into the computer, subsamples the laser range and amplitude data, interleaves the subsampled data with the dGPS information, and records the resulting interleaved data stream.

Nelson, Ross↗

Imaging Plasma Density Structures in the Soft X-Rays Generated by Solar Wind Charge Exchange with Neutrals

Both heliophysics and planetary physics seek to understand the complex nature of the solar wind's interaction with solar system obstacles like Earth's magnetosphere, the ionospheres of Venus and Mars, and comets. Studies with this objective are frequently conducted with the help of single or multipoint in situ electromagnetic field and particle observations, guided by the predictions of both local and global numerical simulations, and placed in context by observations from far and extreme ultraviolet (FUV, EUV), hard X-ray, and energetic neutral atom imagers (ENA). Each proposed interaction mechanism (e.g., steady or transient magnetic reconnection, local or global magnetic reconnection, ion pick-up, or the Kelvin- Helmholtz instability) generates diagnostic plasma density structures. The significance of each mechanism to the overall interaction (as measured in terms of atmospheric/ionospheric loss at comets, Venus, and Mars or global magnetospheric/ionospheric convection at Earth) remains to be determined but can be evaluated on the basis of how often the density signatures that it generates are observed as a function of solar wind conditions. This paper reviews efforts to image the diagnostic plasma density structures in the soft (low energy, 0.1-2.0 keV) X-rays produced when high charge state solar wind ions exchange electrons with the exospheric neutrals surrounding solar system obstacles.

Sibeck, David G.↗

Backside charging of the CCD

Until recently, the usefulness of the charge coupled device (CCD) as an imaging sensor was thought to be restricted to within rather narrow boundaries of the visible and near IR spectrum. However, since the discovery of backside charging the full potential of CCD performance is now realized. Indeed, the technique of backside charging not only allows the CCD to be used directly in the UV, EUV, and soft X-ray regimes, it has opened up new opportunities in optimizing charge collection processes as well. The technique of backside charging is discussed, and its properties, use, and potential in the future as it applies to the CCD are described.

Janesick, J.↗

Fast-ion D{alpha} measurements of the fast-ion distribution (invited)

The fast-ion D{alpha} (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-{alpha} light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of D{alpha} light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of {approx}1 ms, {approx}10 keV, and {approx}2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of {approx}50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗