Effects of the hollow cathode discharge on throttled ion thruster performance.
An experimental study performed on a 20 cm electron bombardment thruster shows substantial improvements in throttled performance can be achieved if cathode discharge region diameter and length, cathode flow rate and baffle aperture area are reduced simultaneously. This improvement is related to a thruster operating mode in which arc current does not vary significantly with arc voltage. In this mode it is possible to operate the thruster at a high arc voltage and a correspondingly high primary electron energy without the penalty of a prohibitively high arc power. Langmuir probe data indicate the arc current is limited by the cathode region plasma potential and electron density which are both nearly invariant with arc voltage.