Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hand samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

First principles calculation of finite temperature magnetism in Fe and Fe3C

Density functional calculations have proven to be a useful tool in the study of ground state properties of many materials. The investigation of finite temperature magnetism, on the other hand, has to rely usually on the usage of empirical models that allow the large number of evaluations of the systems Hamiltonian that are required to obtain the phase space sampling needed to obtain the free energy, specific heat, magnetization, susceptibility, and other quantities as function of temperature. We have demonstrated a solution to this problem that harnesses the computational power of today s large massively parallel computers by combining a classical Wang Landau Monte-Carlo calculation [F. Wang and D. P. Landau, Phys. Rev. Lett. 86, 2050 (2001)] with our first principles multiple scattering electronic structure code [Y. Wang et al., Phys. Rev. Lett. 75, 2867 (1995)] that allows the energy calculation of constrained magnetic states [M. Eisenbach et al., Proceedings of the Conference on High Performance Computing, Networking, Storage and Analysis (ACM, New York, 2009)]. We present our calculations of finite temperature properties of Fe and Fe3C using this approach and we find the Curie temperatures to be 980 and 425K, respectively.

36 MATERIALS SCIENCE↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

Determination of Significant Composite Processing Factors by Designed Experiment (MSFC Center Director's Discretionary Fund)

To determie composite material properties' effects from porcessing variables, a 3 factorial designed experiment with two replicates was conducted. The factors were cure method (oven versus autoclave), layup (hand versus tape-laying machine), and thickness (8 versus 52 ply). Four material systems were tested: AS4/3501-6, IM7/8551-7, IM7/F655 bismaleimide (BMI), and shear tests on IM7/F584. Material properties were G(sub 12), v(sub 12), E(sub 1c) and E(sub 2c). Since the samples were necessarily nonstandard, strengths, though recorded, cannot be considered valid. Void content was also compared. Autoclave curing helped material properties for the low modulus fiber material but showed little benefit for higher stiffness fibers. The number of plies was very important for epoxy composites but not for the BMI. E(sub 1) was generally unaffected by any factor. Particularly high void content did correlate to reduced properties. Autoclave curing reduced void content over oven curiing but a moderate amount of voids, less than 1 percent void content, didnot correlate with material properties. Oven cures and hand layups can produce high-quality parts. Part thickness of epoxy composites is important, though cure optimization may improve performance. Significant variations can be caused by processing and it is important that test coupons always reflect the layup and processes of the final part.

Finckenor, J. L.↗

The Nature of Extraterrestrial Amino Acids in Carbonaceous Chondrites and Links to Their Parent Bodies

Meteorites and samples returned from asteroids and comets provide an important record of the physical and chemical processes that occurred in the early solar system and represent some of the oldest solid materials currently available for laboratory analyses. The delivery of organic matter by extraterrestrial material to the early Earth could have been an important source of complex prebiotic organic molecules available for the emergence of life. Analyses of primitive carbonaceous chondrites over the last five decades have revealed a major insoluble organic component [1,2], as well as a complex and highly diverse suite of soluble organic molecules of prebiotic importance [3,4] that includes carboxylic acids, N-heterocycles, sugars, amino acids, amines, and many other organic molecules that have not yet been identified [5]. Amino acids continue to be a primary focus of many soluble organic analyses in carbonaceous chondrites because (1) these molecules are essential components of life (as the monomers of proteins), (2) they have structural diversity (multiple possible isomers) that can be used to help constrain formation mechanisms and parent body conditions, and (3) most amino acids identified in carbonaceous chondrites are chiral, a property that can be used to distinguish between amino acids of extraterrestrial and terrestrial origins. The degree of parent body hydrothermal alteration has been shown to have a major influence on the formation and destruction of amino acids in carbonaceous meteorites as observed in the measured abundances and molecular distributions [6]. Aqueous alteration in primitive asteroids could have also led to the preferential enrichment of some left-handed amino acids over their right-handed forms, an astounding discovery that suggests that the origin of life on Earth or elsewhere was biased toward left-handed amino acid homochirality [7,8]. This talk will give an overview of what is known about the amino acid composition of carbonaceous chondrites, present some key unanswered questions, and discuss how the analysis of samples returned from asteroids Ryugu and Bennu will further advance our understanding of parent body chemistry and potential contributions from carbonaceous asteroids to the origin of life on Earth or elsewhere.

Daniel P. Glavin↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements?and to protect our science from human contamination?we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

planetary protection↗

Designing the stripe-ordered cuprate phase diagram through uniaxial-stress

The ability to efficiently control charge and spin in the cuprate high-temperature superconductors is crucial for fundamental research and underpins technological development. Here, we explore the tunability of magnetism, superconductivity and crystal structure in the stripe phase of the cuprate La 2-x Ba x CuO 4 , with x = 0.115 and 0.135, by employing temperature-dependent (down to 400 mK) muon-spin rotation and AC susceptibility, as well as X-ray scattering experiments under compressive uniaxial stress in the CuO 2 plane. A sixfold increase of the 3-dimensional (3D) superconducting critical temperature T c and a full recovery of the 3D phase coherence is observed in both samples with the application of extremely low uniaxial stress of 0.1 GPa. This finding demonstrates the removal of the well-known 1/8-anomaly of cuprates by uniaxial stress. On the other hand, the spin-stripe order temperature as well as the magnetic fraction at 400 mK show only a modest decrease under stress. Moreover, the onset temperatures of 3D superconductivity and spin-stripe order are very similar in the large stress regime. However, a substantial decrease of the magnetic volume fraction and a full suppression of the low-temperature tetragonal structure is found at elevated temperatures, which is a necessary condition for the development of the 3D superconducting phase with optimal T c . Our results evidence a remarkable cooperation between the long-range static spin-stripe order and the underlying crystalline order with the three-dimensional fully coherent superconductivity. Overall, these results suggest that the stripe- and the SC order may have a common physical mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistics of Storm Updraft Velocities from TWP-ICE Including Verification with Profiling Measurements

Comparisons between direct measurements and modeled values of vertical air motions in precipitating systems are complicated by differences in temporal and spatial scales. On one hand, vertically profiling radars more directly measure the vertical air motion but do not adequately capture full storm dynamics. On the other hand, vertical air motions retrieved from two or more scanning Doppler radars capture the full storm dynamics but require model constraints that may not capture all updraft features because of inadequate sampling, resolution, numerical constraints, and the fact that the storm is evolving as it is scanned by the radars. To investigate the veracity of radar-based retrievals, which can be used to verify numerically modeled vertical air motions, this article presents several case studies from storm events around Darwin, Northern Territory, Australia, in which measurements from a dual-frequency radar profiler system and volumetric radar-based wind retrievals are compared. While a direct comparison was not possible because of instrumentation location, an indirect comparison shows promising results, with volume retrievals comparing well to those obtained from the profiling system. This prompted a statistical analysis of an extended period of an active monsoon period during the Tropical Warm Pool International Cloud Experiment (TWP-ICE). Results show less vigorous deep convective cores with maximum updraft velocities occurring at lower heights than some cloudresolving modeling studies suggest. 1. Introduction The regionalization of global climate models has been a driver of demand for more complex convective parameterization schemes. A key readjustment of the modeled atmosphere

Collis, Scott↗

Characterizing the γ-Ray Emission from Low-luminosity AGN

A majority of the active galactic nuclei (AGN) in the local Universe are classified as low-luminosity AGN (LLAGN), having bolometric luminosities ≲10 42 erg s −1 . Although high-energy γ-ray emission is predicted from both the jets and disks of LLAGN, to date only four have been detected by the Fermi Large Area Telescope (Fermi-LAT). In this work, we therefore conduct a comprehensive study of all the LLAGN from the Palomar spectroscopic survey of bright, northern galaxies, including both subthreshold and detected γ-ray sources, using 14.4 yr of LAT data. Our analysis results in a new detection of one LLAGN, as well as a detection of the subthreshold population using a stacking technique. We find that the signal from the subthreshold sample is consistent with being dominated by star formation activity, although a contribution from compact jets or a mixed contribution from jetted and nonjetted systems is also feasible. On the other hand, the individually detected LLAGN are likely dominated by jet emission. We perform detailed spectral modeling for a subset of these sources and find that the γ-ray signal can be explained by synchrotron self-Compton radiation if the inner jet emission region is weakly magnetized, with its total energy density being strongly particle dominated and only slowly moving. With this work we also publicly release our Python-based stacking library for analyzing subthreshold source populations with the LAT based on a proven technique used in numerous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Dissolution of bulk specimens of silicon nitride

An accurate chemical characterization of silicon nitride has become important in connection with current efforts to incorporate components of this material into advanced heat engines. However, there are problems concerning a chemical analysis of bulk silicon nitride. Current analytical methods require the pulverization of bulk specimens. A pulverization procedure making use of grinding media, on the other hand, will introduce contaminants. A description is given of a dissolution procedure which overcomes these difficulties. It has been found that up to at least 0.6 g solid pieces of various samples of hot pressed and reaction bonded silicon nitride can be decomposed in a mixture of 3 mL hydrofluoric acid and 1 mL nitric acid overnight at 150 C in a Parr bomb. High-purity silicon nitride is completely soluble in nitric acid after treatment in the bomb. Following decomposition, silicon and hydrofluoric acid are volatilized and insoluble fluorides are converted to a soluble form.

Davis, W. F.↗

Ultra-compact system for characterization of physical, chemical and ignition properties of fuels

The present disclosure relates to a miniaturized fuel laboratory system having exterior dimensions enabling the system to be at least one of hand-holdable or contained on a component. The system makes use of a processor, a fuel inlet port for receiving a quantity of fuel to be used as a fuel test sample, and at least one fuel sensor in communication with the fuel inlet port for receiving the fuel test sample. The processor uses the information obtained by the fuel sensor to determine at least one characteristic of the fuel test sample.

Mcnenly, Matthew J.↗

Search for top quark partners with charge 5/3 in the same-sign dilepton and single-lepton final states in proton-proton collisions at $\sqrt{s}=13$ TeV

A search for the pair production of heavy fermionic partners of the top quark with charge 5/3 (X$_{5/3}$) is performed in proton-proton collisions at a center-of-mass energy of 13 TeV with the CMS detector at the CERN LHC. The data sample analyzed corresponds to an integrated luminosity of 35.9 fb$^{-1}$. The X$_{5/3}$ quark is assumed always to decay into a top quark and a W boson. Both the right-handed and left-handed X$_{5/3}$ couplings to the W boson are considered. Final states with either a pair of same-sign leptons or a single lepton are studied. No significant excess of events is observed above the expected standard model background. Lower limits at 95% confidence level on the X$_{5/3}$ quark mass are set at 1.33 and 1.30 TeV respectively for the case of right-handed and left-handed couplings to W bosons in a combination of the same-sign dilepton and single-lepton final states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Depicting the roles of CuO secondary phase and heat treatment in driving the magnetic and magnetocaloric features of Pr 2/3 Sr 1/3 MnO 3 manganite

In this work, we report a detailed experimental study regarding the impact of copper oxide (CuO) secondary phase and heat treatments on the structural, magnetic, and magnetocaloric properties of the near-room temperature Pr 2/3 Sr 1/3 MnO 3 (PSMO) magnetic refrigerant. Our investigations are carried out by using structural and microstructural analyses, alongside magnetization measurements. Here, the analysis of X-ray diffraction data of PSMO(95%)-CuO(5%) (PSMO-CuO) samples shows the coexistence of both CuO and PSMO phases. Further, the microstructural analysis of PSMO-CuO reveals that the addition of CuO significantly enhances the grains size. On the other hand, the added secondary phase markedly reduces the Curie temperature (T c ) from 293 K for PSMO to about 273 K for PSMO-CuO composite while increasing the magnetocaloric effect. This decrease in T c is associated with a significant change from 162° to about 156° in the Mn-OII-Mn bond angle respectively. Moreover, performed investigations regarding the role of heat treatments unveil that the observed changes in the structural and magnetic features are mainly driven by the secondary phase that modify grains size and double-exchange interactions in the PSMO compound. Interestingly, our findings demonstrate that the Curie temperature of the PSMO and accordingly its magnetocaloric effect can be tailored by adding small amounts of CuO without need to substitution on cation sites. In the light of obtained results, a multilayered refrigerant composed of PSMO and PSMO-CuO is proposed to cover the magnetic cooling temperature range close to room-temperature. The resulting entropy change remains practically constant between 273 K and 293 K. Such a behavior is highly appreciated from a practical point of view, particularly in cases where the cooling process is carried out by using the AMR and Ericsson cycles.

36 MATERIALS SCIENCE↗

Effects of long pulse width and high pulsing frequency on surface superhydrophobicity of polytetrafluoroethylene in quasi-direct-current plasma immersion ion implantation

Long pulse, high frequency quasi-direct-current (dc) oxygen plasma immersion ion implantation (PIII) is utilized to create a superhydrophobic polytetrafluoroethylene (PTFE) surface with a water contact angle of over 150 deg. This technique allows the use of a high duty cycle without deleterious effects such as extensive sample heating encountered in conventional PIII. Scanning electron microscopy images review submicrometer-nanometer structures on the PTFE surface after long pulse, high frequency PIII indicative of ion implantation. On the other hand, plasma modification is the dominant effect in short pulse, low frequency PIII. Quasi-dc PIII is demonstrated to offer adjustable synergistic plasma and ion beam effects.

36 MATERIALS SCIENCE↗

Microscopic model of the doping dependence of linewidths in monolayer transition metal dichalcogenides

A fully microscopic model of the doping-dependent exciton and trion linewidths in the absorption spectra of monolayer transition metal dichalcogenides in the low temperature and low-doping regime is explored. The approach is based on perturbation theory and avoids the use of phenomenological parameters. In the low-doping regime, we find that the trion linewidth is relatively insensitive to doping levels, while the exciton linewidth increases monotonically with doping. On the other hand, we argue that the trion linewidth shows a somewhat stronger temperature dependence. The magnitudes of the linewidths are likely to be masked by phonon scattering for T ≥ 20 K in encapsulated samples in the low-doping regime. We discuss the breakdown of perturbation theory, which should occur at relatively low-doping levels and low temperatures. Our work also paves the way toward understanding a variety of related scattering processes, including impact ionization and Auger scattering in clean 2D samples

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum magnetism in the frustrated square lattice oxyhalides YbBi 2 IO 4 and YbBi 2 ClO 4

Square-lattice systems offer a direct route for realizing two-dimensional (2D) quantum magnetism with frustration induced by competing interactions. In this work, the square lattice materials YbBi 2 IO 4 and YbBi 2 ClO 4 were investigated using a combination of magnetization and specific-heat measurements on polycrystalline samples. Specific-heat measurements provide evidence for long-range magnetic order below $T$ N = 0.21 K (0.25 K) for YbBi 2 IO 4 (YbBi 2 ClO 4 ). On the other hand, a rather broad maximum is found in the temperature-dependent magnetic susceptibility, located at $T$ max = 0.33 K (0.38 K) in YbBi 2 IO 4 (YbBi 2 ClO 4 ), consistent with the quasi-2D magnetism expected for the large separation between the magnetic layers. Estimation of the magnetic entropy supports the expected Kramers' doublet ground state for Yb 3+ and the observed paramagnetic behavior is consistent with a well-isolated doublet. Roughly two-thirds of the entropy is consumed above $T$ N , due to a combination of the quasi-2D behavior and magnetic frustration. The impact of frustration is examined from the viewpoint of a simplified $J$ 1 -$J$ 2 square lattice model, which is frustrated for antiferromagnetic interactions. Specifically, a high-temperature series expansion analysis of the temperature-dependent specific-heat and magnetization data yields $J$ 2 /$J$ 1 = 0.30 (=0.23) for YbBi 2 IO 4 (YbBi 2 ClO 4 ). In conclusion, this simplified analysis suggests strong frustration that should promote significant quantum fluctuations in these compounds, and thus motivates future work on the static and dynamic magnetic properties of these materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of focused ion beam induced damage on the plasticity of micropillars

The hardening effects of focused ion beam (FIB) induced damage produced during the fabrication of micropillars are examined by introducing a surface layer of nanosized obstacles into a dislocation dynamics simulation. The influence of the depth and strength of the obstacles as a function of pillar diameter is assessed parametrically. We show that for a selected set of sample sizes between 0.5 and 1.0 {mu}m, the flow strength can increase by 10-20 %, for an obstacle strength of 750 MPa, and damage depth of 100 nm. On the other hand, for sizes larger and smaller than this range, the effect of damage is negligible. Results show that the obstacles formed during the FIB milling may be expected to alter the microstructure of micropillars, however, they have a negligible effect on the observed size-strength scaling laws.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗