Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Hemobilia after CT-guided radiofrequency ablation of liver tumors: frequency, risk factors, and clinical significance

Purpose: The purpose of the study is to evaluate the frequency, risk factors, and clinical significance of hemobilia after percutaneous computed tomography (CT)-guided radiofrequency ablation (RFA) of liver tumors. Materials and methods: From January 2013 to September 2016, 195 patients received 267 sessions of CT-guided RFA for liver tumors at our institution. The CT images during and immediately after the RFA were retrospectively reviewed. The frequency of hemobilia development and clinical outcome of patients with hemobilia were studied. Risk factors were identified by comparison between the hemobilia and non-hemobilia groups using univariate and multivariate analysis. The clinical courses of patients with hemobilia were also reviewed. Results: The frequency of CT detected hemobilia after RFA was 8.2% (22/267). The majority of the clinical courses were self-limited. Univariate analysis showed that the tumor numbers (p = 0.015), the central type puncture track (p < 0.001), the length of the puncture track (p = 0.033), and the platelet count (p = 0.026) were significantly associated with the development of hemobilia. Multivariate analysis demonstrated that the central type puncture track (p < 0.024) and the platelet count (p = 0.023) were significant independent risk factors. Conclusion: Detection of hemobilia on CT images immediately after percutaneous RFA for liver tumors was not rare. Low platelet count and central type puncture track are independent risk factors. In most cases, hemobilia presented as a minor complication with favorable prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a steerable needle for CT-guided nerve plexus blockade

Purpose: Demonstrate the use of a new steerable needle for CT-guided neural plexus blockade to avoid traversing the kidneys. Materials and methods: Retrospective evaluation of 23 consecutive CT-guided neural plexus blockade procedures in which a new steerable needle was used in the last 13 and compared with the prior 10 procedures in which a standard needle was used. Results: Use of the steerable needle was beneficial to reach the target area without traversing a kidney or other organs in 6/13 (46%) procedures; in the other 7 procedures there was no benefit. A kidney was traversed in 0/13 procedures performed with the steerable needle. In contrast, a kidney was traversed in 4/10 (40%) procedures using a standard needle (P = 0.02). There was no significant difference in clinical benefit (P = 1.00) or complications (P = 0.56) between procedures using the steerable needle versus a standard needle. Three complications were observed (1 major and 2 minor) felt to be related to the injection and not the needle type. Conclusions: The utility of a steerable 21-gauge needle during neural plexus blockades was found to allow for avoidance of the kidneys when compared to a standard (non-steerable) needle. Interventional radiologists may find this needle and its future iterations useful for neural blockades, as well as other procedures, when intervening structures need to be avoided. Level of evidence: Level 3, Non-randomized controlled cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Therapeutic Results of Computed Tomography-Guided Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma: Results of 265 Tumors in 79 Patients

Purpose. To elucidate the local therapeutic results of computed tomography (CT)-guided transcatheter arterial chemoembolization (TACE) as initial treatment for hepatocellular carcinoma (HCC), and to verify factors which affect local therapeutic results. Methods. From 1992 to 2002, 265 tumors of 79 HCC patients were treated by 139 sessions of CT-guided TACE as initial treatment. Among these 265 tumors, 182 constituted multiple new lesions, and the remaining 83 tumors were single new lesions. Local recurrence was retrospectively ascertained on follow-up CT images obtained after TACE. Results. The overall local recurrence-free rates (LR-FRs) after a single TACE session at 6, 12, and 36 months were 67%, 49%, and 28%; those of the single new lesions were 80%, 66%, and 32%; and those of tumors with complete lipiodol accumulation were 82%, 68%, and 41%, respectively. LR-FRs of tumors of the single new lesions, and those of tumors with complete lipiodol accumulation, were significantly higher than the LR-FRs of multiple new lesions and tumors with incomplete lipiodol accumulation, respectively. For single new lesions {<=}4 cm and the tumors that were one of multiple new lesions, there were no significant differences in the LR-FRs regarding the number of TACE sessions on the basis of patient, tumor location, or tumor size. Conclusion. Local therapeutic results of single new lesions were better than those of multiple new lesions, and the local therapeutic effect of TACE was not affected by the number of treatments on the basis of patient, tumor location, or tumor size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pericardial Tamponade Following CT-Guided Lung Biopsy

While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0{sup o} and sub-0{sup o}C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0{sup o}C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up to 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radiofrequency Ablation in Patients with Hepatic Metastases from Breast Cancer

The purpose of this study was to evaluate technical success, technique effectiveness, and survival following radiofrequency ablation for breast cancer liver metastases and to determine prognostic factors. Forty-three patients with 111 breast cancer liver metastases underwent CT-guided percutaneous radiofrequency (RF) ablation. Technical success and technique effectiveness was evaluated by performing serial CT scans. We assessed the prognostic value of hormone receptor status, overexpression of human epidermal growth factor receptor 2 (HER2), and presence of extrahepatic tumor spread. Survival rates were calculated using the Kaplan-Meier method. Technical success was achieved in 107 metastases (96%). Primary technique effectiveness was 96%. During follow-up local tumor progression was observed in 15 metastases, representing a secondary technique effectiveness of 86.5%. The overall time to progression to the liver was 10.5 months. The estimated overall median survival was 58.6 months. There was no significant difference in terms of survival probability with respect to hormone receptor status, HER2 overexpression, and presence of isolated bone metastases. Survival was significantly lower among patients with extrahepatic disease, with the exception of skeletal metastases. We conclude that CT-guided RF ablation of liver metastases from breast cancer can be performed with a high degree of technical success and technique effectiveness, providing promising survival rates in patients with no visceral extrahepatic disease. Solitary bone metastases did not negatively affect survival probability after RF ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of Local Progression After Computed Tomography-Guided Percutaneous Radiofrequency Ablation for Unresectable Lung Tumors: 9-Year Experience in a Single Institution

The purpose of this study was to retrospectively determine the local control rate and contributing factors to local progression after computed tomography (CT)-guided radiofrequency ablation (RFA) for unresectable lung tumor. This study included 138 lung tumors in 72 patients (56 men and 16 women; age 70.0 {+-} 11.6 years (range 31-94); mean tumor size 2.1 {+-} 1.2 cm [range 0.2-9]) who underwent lung RFA between June 2000 and May 2009. Mean follow-up periods for patients and tumors were 14 and 12 months, respectively. The local progression-free rate and survival rate were calculated to determine the contributing factors to local progression. During follow-up, 44 of 138 (32%) lung tumors showed local progression. The 1-, 2-, 3-, and 5-year overall local control rates were 61, 57, 57, and 38%, respectively. The risk factors for local progression were age ({>=}70 years), tumor size ({>=}2 cm), sex (male), and no achievement of roll-off during RFA (P < 0.05). Multivariate analysis identified tumor size {>=}2 cm as the only independent factor for local progression (P = 0.003). For tumors <2 cm, 17 of 68 (25%) showed local progression, and the 1-, 2-, and 3-year overall local control rates were 77, 73, and 73%, respectively. Multivariate analysis identified that age {>=}70 years was an independent determinant of local progression for tumors <2 cm in diameter (P = 0.011). The present study showed that 32% of lung tumors developed local progression after CT-guided RFA. The significant risk factor for local progression after RFA for lung tumors was tumor size {>=}2 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Institution Results of Image-Guided Nonplugged Percutaneous Versus Transjugular Liver Biopsy

Purpose: To retrospectively review patients who underwent transjugular and image-guided percutaneous biopsy and compare the relative risk of ascites, thrombocytopenia, and coagulopathy. Materials and Methods: From August 2001 through February 2006, a total of 238 liver biopsies were performed. The radiologist reviewed all patient referrals for transjugular biopsy. These patients either underwent transjugular biopsy or were reassigned to percutaneous biopsy (crossover group). Patients referred to percutaneous image-guided liver biopsy underwent this same procedure. Biopsies were considered successful if a tissue diagnosis could be made from the samples obtained. Results: A total of 36 transjugular biopsies were performed with 3 total (8.3%) and 1 major (2.8%) complications. A total of 171 percutaneous biopsies were performed with 10 (5.8%) total and 3 (1.8%) major complications. The crossover group showed a total of 4 (12.9%) complications with 1 (3.2%) major complication. Sample adequacy was 91.9% for transjugular and 99.5% for percutaneous biopsy. Conclusion: Both transjugular and percutaneous liver biopsy techniques are efficacious and safe. Contraindications such as thrombocytopenia, coagulopathy, and ascites are indicators of greater complications but are not necessarily prevented by transjugular biopsy. Percutaneous biopsy more frequently yields a diagnostic specimen than transjugular biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Magnetic Resonance Imaging-Guided Free-Hand Aspiration of Symptomatic Nerve Route Compressing Lumbosacral Cysts Using a 1.0-Tesla Open Magnetic Resonance Imaging System

Purpose: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence. Materials and Methods: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.0-T open MRI system. For MRI interventional cyst aspiration, an interactive sequence was used, allowing for near real-time position validation of the needle in any desired three-dimensional plane. Results: Seven of 11 cysts in the lumbosacral region were successfully aspirated (average 10.1 mm [SD {+-} 1.9]). After successful cyst aspiration, each patient reported speedy relief of initial symptoms. Average cyst size was 9.6 mm ({+-}2.6 mm). Four cysts (8.8 {+-} 3.8 mm) could not be aspirated. Conclusion: Open MRI systems with tailored interactive sequences have great potential for cyst aspiration in the lumbosacral region. The authors perceive major advantages of the MR-guided cyst aspiration in its minimally invasive character compared to direct and open surgical options along with consecutive less trauma, less stress, and also less side-effects for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner

Purpose: The aim of this work was to develop and test a general methodology for the planning and performance of robot-assisted, MR-guided interventions. This methodology also includes the employment of software tools with appropriately tailored routines to effectively exploit the capabilities of MRI and address the relevant spatial limitations. Methods: The described methodology consists of: (1) patient-customized feasibility study that focuses on the geometric limitations imposed by the gantry, the robotic hardware, and interventional tools, as well as the patient; (2) stereotactic preoperative planning for initial positioning of the manipulator and alignment of its end-effector with a selected target; and (3) real-time, intraoperative tool tracking and monitoring of the actual intervention execution. Testing was performed inside a standard 1.5T MRI scanner in which the MR-compatible manipulator is deployed to provide the required access. Results: A volunteer imaging study demonstrates the application of the feasibility stage. A phantom study on needle targeting is also presented, demonstrating the applicability and effectiveness of the proposed preoperative and intraoperative stages of the methodology. For this purpose, a manually actuated, MR-compatible robotic manipulation system was used to accurately acquire a prescribed target through alternative approaching paths. Conclusions: The methodology presented and experimentally examined allows the effective performance of MR-guided interventions. It is suitable for, but not restricted to, needle-targeting applications assisted by a robotic manipulation system, which can be deployed inside a cylindrical scanner to provide the required access to the patient facilitating real-time guidance and monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations

Introduction: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluated according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months. Conclusions: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗