Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid connected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

5G Enabled Transformative Co-design and Co-simulation Framework for Grid Decarbonization and Modernization

5G is a breakthrough technology to enable a fully mobile and connected society, and a 5G-enabled digital continuum will be one of the critical foundations for clean energy economy and grid modernization. The clean energy transformation not only requires innovative manufacturing, algorithm, application, and cross-domain co-simulation, but also a systematic evaluation and comprehensive support on the microelectronic and architectural computing customization to enable and maximize the high renewable penetration in the future power grid. The co-design of decarbonized grid, reliable yet efficient communication, and affordable yet ubiquitous computing will unlock the potential of almost any available tools for the undergoing clean energy transformation. 5G is also an opportunity to rethink the paradigm of infrastructure planning, as computing will be one of the core services for society alongside electricity and communication services.

5G↗

Disruption avoidance via island suppression: the crucial roles of DIII-D and foundational research

The FESAC long range plan calls out disruption avoidance and mitigation as key remaining technical gaps. In discussing the roles of DIII-D and NSTX-U, the FESAC long range plan says “Additional research on these facilities, in combination with private and international collaborations, continuing support of existing university tokamak programs, and utilization of US expertise in theory and simulation, is needed to find solutions to remaining technical gaps. These gaps include disruption prediction, avoidance, and mitigation …”. Disruptions pose an existential threat to ITER and to FPPs. For a fusion reactor, unplanned shutdowns caused by disruptions will be a significant barrier to connecting such a reactor to the electric grid, even if disruption mitigation is successful. Disruption studies for ITER in recent years have largely focused on disruption mitigation (e.g., pellet injection), motivated by near-term deadlines for finalizing the design of the mitigation hardware. It is recognized, however, that mitigation alone will not suffice. The 2022 U.S. ITER Research Needs Workshop Report states that ”[d]isruptions are considered the largest threat to the ITER Research Program”, and that “[m]itigation should be a last resort”. As we discuss below, there are unresolved foundational issues that play a critical role in avoidance, and DIII-D is an ideal device for generating the data needed to address these issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 15 kWe (nominal) solar thermal-electric power conversion concept definition study: Steam Rankin reciprocator system

A conceptual design of a 3600 rpm reciprocation expander was developed for maximum thermal input power of 80 kW. The conceptual design covered two engine configurations; a single cylinder design for simple cycle operation and a two cylinder design for reheat cycle operation. The reheat expander contains a high pressure cylinder and a low pressure cylinder with steam being reheated to the initial inlet temperature after expansion in the high pressure cylinder. Power generation is accomplished with a three-phase induction motor coupled directly to the expander and connected electrically to the public utility power grid. The expander, generator, water pump and control system weigh 297 kg and are dish mounted. The steam condenser, water tank and accessory pumps are ground based. Maximum heat engine efficiency is 33 percent: maximum power conversion efficiency is 30 percent. Total cost is $3,307 or $138 per kW of maximum output power.

Wingenback, W.↗

Predicting Temperatures In Ball Bearings

Computer simulations speed design studies. Analyses performed in two or three dimensions. Sizes and shapes of components approximated by zones or nodes connected by gridlines. From geometric information about grids and boundary conditions, properties of bearing and lubricant materials, and information supplied by users, thermal-analysis programs generate mathematical models for thermal transport. Thermal analysis of high-speed rolling contact bearings matured so much that computerized numerical simulations replace expensive time consuming full scale experiments.

Wagner, William R.↗

Unlocking the price

To help balance load and power generation that ensue from the electrification of transportation and the increased connection of variable power sources to the grid, ABB has developed an RL-based dynamic price model for EV charging with the required flexibility to respond to changing grid conditions.

Suryanarayana, Harish↗

Predicting Geologic Behavior in Carbon Storage Projects Using Graph Neural Network

This study was invited to presented at NVIDIA's GTC conference to highlight the potential of Graph Neural Network as a novel and promising methodology for predicting pressure and saturation evolution in carbon storage projects. Carbon capture and storage (CCS) technology plays a pivotal role in mitigating greenhouse gas emissions, facilitating the transition to a low-carbon future. Effective management of subsurface reservoirs is essential to ensure the safe and efficient storage of captured carbon dioxide (CO₂). Accurate predictions of pressure and saturation over time are critical for evaluating the long-term performance and integrity of CCS projects. In recent years, Graph Neural Network (GNN) has emerged as a powerful framework for analyzing complex data in graph-structured domains. This abstract explores the application of GNN to forecast pressure and saturation evolution in carbon storage projects. Traditional numerical simulations of subsurface reservoirs have proven successful in providing pressure and saturation forecasts. However, these simulations involve massive amounts of computational effort and require extensive domain expertise for proper model calibration and validation. Graph Neural Operator offers an alternative approach that harnesses the inherent graph structure of reservoirs, where nodes represent reservoir grid cells and edges represent the geological connectivity between them.

Shih, Chung Yan↗

Parallel and Distributed System Simulation

This exploratory study initiated our research into the software infrastructure necessary to support the modeling and simulation techniques that are most appropriate for the Information Power Grid. Such computational power grids will use high-performance networking to connect hardware, software, instruments, databases, and people into a seamless web that supports a new generation of computation-rich problem solving environments for scientists and engineers. In this context we looked at evaluating the NetSolve software environment for network computing that leverages the potential of such systems while addressing their complexities. NetSolve's main purpose is to enable the creation of complex applications that harness the immense power of the grid, yet are simple to use and easy to deploy. NetSolve uses a modular, client-agent-server architecture to create a system that is very easy to use. Moreover, it is designed to be highly composable in that it readily permits new resources to be added by anyone willing to do so. In these respects NetSolve is to the Grid what the World Wide Web is to the Internet. But like the Web, the design that makes these wonderful features possible can also impose significant limitations on the performance and robustness of a NetSolve system. This project explored the design innovations that push the performance and robustness of the NetSolve paradigm as far as possible without sacrificing the Web-like ease of use and composability that make it so powerful.

Dongarra, Jack↗

Highly Available Nuclear Power for Mission-Critical Applications

Some energy consumers require power on an anytime, all-year-round basis with a high level of certainty, including defense installations, isolated communities, and some industrial processes. For these customers, interruptions in electricity or heat can mean substantial financial loss or even loss of life. In the absence of grid-scale energy storage, a high level of power availability can be accomplished only through the robustness and redundancy of power generators. The NuScale small modular reactor design is well suited to provide highly available power because of several features related to both the nuclear steam supply system and the overall plant design. In analogy to Redundant Array of Independent Disks (RAID) systems used to provide highly reliable data storage, a NuScale plant can assure sustained power generation by virtue of its Redundant Array of Integral Reactors (RAIR).This paper describes the NuScale RAIR plant features and summarizes the results of a rigorous analysis of RAIR availability as a function of power or, conversely, the RAIR plant output power as a function of power availability. The analysis utilized the Matrix Laboratory code (MATLAB) and included probability distributions for the frequency and duration of module outages due to planned and unplanned events. Further, the study evaluated the impact of implementing turbine bypass rather than module shutdown and using one or more modules to supply house loads in the case of loss of off-site power (LOOP). Availability results are presented for a 12-module RAIR plant with and without turbine bypass enabled during a LOOP and for different possible connections to the off-site power distribution grid and dedicated service loads. Results indicate that a very high level of availability can be achieved at relatively high power output levels, regardless of turbine bypass and dedicated load connection, compared to the operating fleet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time-domain analysis of planar microstrip devices using a generalized Yee-algorithm based on unstructured grids

The generalized Yee-algorithm is presented for the temporal full-wave analysis of planar microstrip devices. This algorithm has the significant advantage over the traditional Yee-algorithm in that it is based on unstructured and irregular grids. The robustness of the generalized Yee-algorithm is that structures that contain curved conductors or complex three-dimensional geometries can be more accurately, and much more conveniently modeled using standard automatic grid generation techniques. This generalized Yee-algorithm is based on the the time-marching solution of the discrete form of Maxwell's equations in their integral form. To this end, the electric and magnetic fields are discretized over a dual, irregular, and unstructured grid. The primary grid is assumed to be composed of general fitted polyhedra distributed throughout the volume. The secondary grid (or dual grid) is built up of the closed polyhedra whose edges connect the centroid's of adjacent primary cells, penetrating shared faces. Faraday's law and Ampere's law are used to update the fields normal to the primary and secondary grid faces, respectively. Subsequently, a correction scheme is introduced to project the normal fields onto the grid edges. It is shown that this scheme is stable, maintains second-order accuracy, and preserves the divergenceless nature of the flux densities. Finally, for computational efficiency the algorithm is structured as a series of sparse matrix-vector multiplications. Based on this scheme, the generalized Yee-algorithm has been implemented on vector and parallel high performance computers in a highly efficient manner.

Gedney, Stephen D.↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connectivity, Centrality, and Bottleneckedness: On Graph Theoretic Methods for Power Systems

This report provides an introduction to selected graph theoretic topics with pertinence to the structural analysis of electric power grid and communication systems. We focus on methodologies for defining, scoring, and identifying connectivity, spectral, and bottleneckeness properties in graphs, as well as vertex and edge importance measures such as centrality. We apply these measures to power systems and communications graph data, discuss and visualize the results, and comment on computational aspects of these methods. We show that graph theoretic methods can provide useful insights into grid and communication network structure, leading to tools and methods that could be used by electric utility engineers to improve key grid and communication network characteristics, such as resilience and scalability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct control of the grid point distribution in meshes generated by elliptic equations

The generation of computational grids suitable for obtaining accurate numerical solutions to the three-dimensional Navier-Stokes equations is the subject of intensive research. For a wide class of nozzle configurations, a three-dimensional grid can be constructed by a sequence of two-dimensional grids in successive cross-sectional planes. The present paper is concerned with numerical generation of two-dimensional grids. An effective method of interior grid control is presented based on a modified elliptic system containing free parameters. For a simply connected region, the free parameters are computed from the Dirichlet boundary values. The resulting interior grid point distribution is controlled entirely by a priori selection of the grid point distribution along the boundaries of the section.

Middlecoff, J. F.↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Topography‐Driven Water Redistribution on Terrestrial Water Storage Change in California Through Ecosystem Responses

Abstract Lateral subsurface flow plays an essential role in sustaining the terrestrial ecosystem, but it is not explicitly represented in most Earth System Models. In this study, we implemented an explicit lateral saturated flow model into the E3SM land model (ELM). The model explicitly describes lateral flow in the saturated zone by representing, for each model grid, an idealized hillslope consisting of five hydrologically connected soil columns. We conducted three model experiments driven by 0.125° atmospheric forcing data during 1980–2015 over California using models of the default ELM, a modified version of ELM to enhance infiltration, and the model with the lateral saturated flow model. The simulated runoff, evapotranspiration, and terrestrial water storage anomaly (TWSA) from the three simulations were evaluated against available observations, and the model explicitly representing lateral flow performs best. The new model produces greater gridcell‐averaged evapotranspiration especially over the mountainous regions with moderate relief and seasonally dry climates. Most importantly, it improves the modeled seasonal variations, interannual variabilities, and the recent decadal decline of TWSA. Many of these improvements can be attributed to the enhanced ecosystem resilience to droughts as demonstrated by transpiration increases caused by lateral flow. Model sensitivity experiments suggest that subsurface runoff is most sensitive to the ratio between horizontal and vertical saturated hydraulic conductivity, followed by hillslope planforms (convergent, divergent, and uniform), number of columns, and lower boundary conditions. Future work should effectively characterize hillslopes in global models and explore the long‐term influences of lateral water movement on modeled biogeochemical cycle.

54 ENVIRONMENTAL SCIENCES↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

distribution system state estimation↗