Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Frequency-doubled CO2 lidar measurement and diode laser spectroscopy of atmospheric CO2

A lidar instrument based on pulsed frequency-doubled carbon-dioxide lasers has been used at 4.88 microns for remote sensing of atmospheric carbon dioxide. A tunable-diode laser spectrometer provided the high-resolution spectroscopic data on carbon-dioxide line strength and line broadening needed for an accurate differential absorption measurement. Initial field measurements are presented, and instrument improvements necessary for accurate carbon dioxide measurement are discussed.

Bufton, J. L.↗

Ultrasonic attenuation in superconducting molybdenum-rhenium alloys.

Investigation of longitudinal sound attenuation in superconducting Mo-Re alloys as a function of temperature, magnetic field, and frequency. Evaporated thin film CdS transducers were used for the measurements at frequencies up to 3 GHz. The normal state attenuation coefficient was found to be proportional to the square of frequency over this frequency range. Measurements in zero magnetic field yielded a value of the energy gap parameter close to the threshold value of 3.56 kTc, appropriate to a weakly coupled dirty limit superconductor.

Ashkin, M.↗

Snow Microphysical Retrieval from the NASA D3R Radar During ICE-POP 2018

A method is developed to use both polarimetric and dual-frequency radar measurements to retrieve microphysical properties of falling snow. It is applied to the Ku- and Ka-band measurements of the NASA dual-polarization, dual-frequency Doppler radar (D3R) obtained during the International Collaborative Experiments for PyeongChang 2018 Olympic and Paralympic winter games (ICE-POP 2018) field campaign and incorporates the Atmospheric Radiative Transfer Simulator (ARTS) microwave singles cattering property database for oriented particles. The retrieval uses optimal estimation to solve for several parameters that describe the particle size distribution (PSD), relative contribution of pristine, aggregate, and rimed ice species, and the orientation distribution along an entire radial simultaneously. Examination of Jacobian matrices and averaging kernels shows that the dual-wavelength ratio (DWR) measurements provide information regarding the characteristic particle size, and to a lesser extent, the rime fraction and shape parameter of the size distribution, whereas the polarimetric measurements provide information regarding the mass fraction of pristine particles and their characteristic size and orientation distribution. Thus, by combining the dual-frequency and polarimetric measurements, some ambiguities can be resolved that should allow a better determination of the PSD and bulk microphysical properties (e.g., snowfall rate) than can be retrieved from single-frequency polarimetric measurements or dual-frequency, single-polarization measurements. The D3R ICE-POP retrievals were validated using Precipitation Imaging Package (PIP) and Pluvio weighing gauge measurements taken nearby at the May Hills ground site. The PIP measures the snow PSD directly, and its measurements can be used to derived the snowfall rate (volumetric and water equivalent), mean volume-weighted particle size, and effective density, as well as particle aspect ratio and orientation. Four retrieval experiments were performed to evaluate the utility of different measurement combinations: Kuonly, DWR-only, Ku-pol, and All-obs. In terms of correlation, the volumetric snowfall rate (r D 0:95) and snow water equivalent rate (r D 0:92) were best retrieved by the Ku-pol method, while the DWR-only method had the lowest magnitude bias for these parameters (-31% and -8 %, respectively). The methods that incorporated DWR also had the best correlation to particle size (r D 0:74 and r D 0:71 for DWR-only and All-obs, respectively), although none of the methods retrieved density particularly well (r D 0:43 for Allobs). The ability of the measurements to retrieve mean aspect ratio was also inconclusive, although the polarimetric methods (Ku-pol and All-obs) had reduced biases and mean absolute error (MAE) relative to the Ku-only and DWR-only methods. The significant biases in particle size and snowfall rate appeared to be related to biases in the measured DWR, emphasizing the need for accurate DWR measurements and frequent calibration in future D3R deployments.

S Joseph Munchak↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Local modeling for FRF estimation with noisy input measurements

The frequency response function (FRF) is an essential means by which dynamic systems are qualified. In recent years, local modeling approaches have been extensively researched and shown to significantly outperform traditional FRF estimators. However, the standard local modeling approach assumes a perfectly-known system input, which results in biased FRF estimates in the presence of input noise. This paper derives a simple adjustment that can be used to improve FRF estimation for systems subjected to random excitation with noisy input data. This improvement can be implemented with little modification to standard local modeling algorithms and with little additional computational burden. The adjustment is coupled with a model selection procedure to avoid underfitting and overfitting. In conclusion, the methods presented in this paper are validated on a simulation, and they are shown to reduce bias due to input noise.

47 OTHER INSTRUMENTATION↗

Radar studies of the equatorial electrojet at three frequencies.

Radar measurements at 16.25, 49.92, and 146.25 MHz of plasma irregularities in the equatorial electrojet were carried out with the objective to investigate the dependence upon wavelength of the properties of the type I and type II irregularities and to see to what extent this dependence is consistent with present theoretical ideas. The equipment and experimental procedure employed is discussed in detail, and the data obtained are analyzed. The following conclusions have been drawn: the Doppler velocity of the type I echoes corresponds to the acoustic velocity rather than the electron streaming velocity; the acoustic velocity varies with wavelength in at least approximate agreement with theory; and the type II irregularities are probably not excited directly, but rather result from nonlinear interactions among larger irregularities.

Balsley, B. B.↗

Orbiter environment at S- and Ku-band frequencies

Detailed measurements of the electric field strength associated with the Ku-band radar and S-band communication link were made by the Plasma Diagnostics Package (PDP) on STS 51F. These measurements were made while the PDP was attached to the Remote Manipulation System arm and again while the PDP was released as a subsatellite. The results indicate that cargo elements that remain inside of the scan limits of the radar should experience fields less than 2 V/m and that elements that may encounter the main beam can use 300 V/m as a design guideline with adequate safety margin. S-band fields tended to be several dB lower than worst-case predictions. Safe design practice indicates that an electric field E = 100/r (r in meters) should be used as a guideline for deployable systems. S-band electric fields within the cargo bay envelope should be less than 2 V/m even with edge diffraction effects and reflections from other payloads taken into account. The absolute accuracy of these measurements is about 2 dB.

Murphy, G. B.↗

Spectral analysis of oscillation instabilities in frequency standards

Phase and frequency fluctuations, inherent in oscillators used as frequency standards, are measured over spectral frequency range of 1 Hz to 5 kHz. Basic measurement system consists of electromechanical phase-locked loop that extracts phase and frequency fluctuations and error multiplier that extends threshold sensitivity.

Lippincott, S.↗

Experimental measurements of the rotating frequencies and mode shapes of a full scale helicopter rotor in a vacuum and correlations with calculated results

This paper presents results of an experimental program conducted to obtain data which can be used for correlations of rotor blade dynamic analyses. Measurements were made of the rotating frequencies and mode shapes of a representative full-scale, two-bladed helicopter rotor in a vacuum. The blades were cantilevered to the hub. Mode shape data were obtained optically using a system of cameras developed specifically for this purpose. Excitation of the rotor was provided by vertical oscillatory motion of the hub. To compare experimental and analytical results, correlations of some experimental measurements with calculations from an existing blade modes computer program based on a Holzer-Myklestad procedure are presented, and the differences between the results are discussed. The experimental and analytical natural frequencies were generally in good agreement as were the principal components of the modal deflections for the flap and lag modes. The torsion mode shape indicated disagreement between the measured and calculated results in regard to the amount of flap and lag motions present in this mode, while the spanwise variations of the measured and calculated torsional components were in agreement.

Lee, B. L.↗

International Space Station Increment-4/5 Microgravity Environment Summary Report

This summary report presents the results of some of the processed acceleration data measured aboard the International Space Station during the period of December 2001 to December 2002. Unlike the past two ISS Increment reports, which were increment specific, this summary report covers two increments: Increments 4 and 5, hereafter referred to as Increment-4/5. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-4/5. Due to time constraint and lack of precise timeline information regarding some payload operations and station activities, not a11 of the activities were analyzed for this report. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System supports science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit supports experiments requiring vibratory acceleration measurement. The International Space Station Increment-4/5 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: The Microgravity Acceleration Measurement System, which consists of two sensors: the low-frequency Orbital Acceleration Research Experiment Sensor Subsystem and the higher frequency High Resolution Accelerometer Package. The low frequency sensor measures up to 1 Hz, but is routinely trimmean filtered to yield much lower frequency acceleration data up to 0.01 Hz. This filtered data can be mapped to arbitrary locations for characterizing the quasi-steady environment for payloads and the vehicle. The high frequency sensor is used to characterize the vibratory environment up to 100 Hz at a single measurement location. The Space Acceleration Measurement System, which deploys high frequency sensors, measures vibratory acceleration data in the range of 0.01 to 400 Hz at multiple measurement locations. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment- 4/5 from December 2001 to December 2002.

Jules, Kenol↗

Measurements of the Low Frequency Gain Fluctuations of a 30 GHz High-Electron-Mobility-Transistor Cryogenic Amplifier

Low frequency gain fluctuations of a 30 GHz cryogenic HEMT amplifier have been measured with the input of the amplifier connected to a 15 K load. Effects of fluctuations of other components of the test set-up were eliminated by use of a power-power correlation technique. Strong correlation between output power fluctuations of the amplifier and drain current fluctuations of the transistors comprising the amplifier are observed. The existence of these correlations introduces the possibility of regressing some of the excess noise from the HEMT amplifier's output using the measured drain currents.

Jarosik, Norman↗

Molecular-Level Insights into the NMR Relaxivity of Gadobutrol Using Quantum and Classical Molecular Simulations

MRI is an indispensable diagnostic tool in modern medicine; however, understanding the molecular-level processes governing NMR relaxation of water in the presence of MRI contrast agents remains a challenge, hindering the molecular-guided development of more effective contrast agents. By using quantum-based polarizable force fields, the first-of-its-kind molecular dynamics (MD) simulations of Gadobutrol are reported where the 1 H NMR longitudinal relaxivity r 1 of the aqueous phase is determined without any adjustable parameters. The MD simulations of r 1 dispersion (i.e., frequency dependence) show good agreement with measurements at frequencies of interest in clinical MRI. Importantly, the simulations reveal key insights into the molecular level processes leading to r 1 dispersion by decomposing the NMR dipole–dipole autocorrelation function G(t) into a discrete set of molecular modes, analogous to the eigenmodes of a quantum harmonic oscillator. The molecular modes reveal important aspects of the underlying mechanisms governing r 1 , such as its multiexponential nature and the importance of the second eigenmodal decay. By simply analyzing the MD trajectories on a parameter-free approach, the Gadobutrol simulations show that the outer-shell water contributes ∼50% of the total relaxivity r 1 compared to the inner-shell water, in contrast to simulations of (nonchelated) gadolinium-aqua where the outer shell contributes only ∼15% of r 1 . The deviation between simulations and measurements of r 1 below clinical MRI frequencies is used to determine the low-frequency electron-spin relaxation time for Gadobutrol, in good agreement with independent studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Physical Model to Determine Snowfall over Land by Microwave Radiometry

Because microwave brightness temperatures emitted by snow covered surfaces are highly variable, snowfall above such surfaces is difficult to observe using window channels that occur at low frequencies (v less than 100 GHz). Furthermore, at frequencies v less than or equal to 37 GHz, sensitivity to liquid hydrometeors is dominant. These problems are mitigated at high frequencies (v greater than 100 GHz) where water vapor screens the surface emission and sensitivity to frozen hydrometeors is significant. However the scattering effect of snowfall in the atmosphere at those higher frequencies is also impacted by water vapor in the upper atmosphere. This work describes the methodology and results of physically-based retrievals of snow falling over land surfaces. The theory of scattering by randomly oriented dry snow particles at high microwave frequencies appears to be better described by regarding snow as a concatenation of equivalent ice spheres rather than as a sphere with the effective dielectric constant of an air-ice mixture. An equivalent sphere snow scattering model was validated against high frequency attenuation measurements. Satellite-based high frequency observations from an Advanced Microwave Sounding Unit (AMSU-B) instrument during the March 5-6, 2001 New England blizzard were used to retrieve snowfall over land. Vertical distributions of snow, temperature and relative humidity profiles were derived from the Pennsylvania State University-National Center for Atmospheric Research (PSU-NCAR) fifth-generation Mesoscale Model (MM5). Those data were applied and modified in a radiative transfer model that derived brightness temperatures consistent with the AMSU-B observations. The retrieved snowfall distribution was validated with radar reflectivity measurements obtained from the National Oceanic and Atmospheric Administration (NOAA) National Weather Service (NWS) ground-based radar network.

Skofronick-Jackson, G.↗

Miniature quantum frequency standard based on the phenomenon of coherent population trapping in vapours of {sup 87}Rb atoms

We report the results of the development and production of a quantum frequency standard (QFS) based on the coherent population trapping (CPT) resonance observed on the D{sub 1} absorption line of {sup 87}Rb atoms. The effect of various physical factors on the QFS frequency is studied, and the optimal physical parameters of the device to attain the best frequency stability are determined. The measured relative frequency instability (Allan deviation) is ∼9 × 10{sup −12} for the averaging time of 1 s, 3 ×10{sup −13} for 1000 s, and 1.5 ×10{sup −12} for 24 hours. For a volume of 60 cm{sup 3}, the power consumption of the entire device is 300 mW. The designed QFS can be used in a new-generation satellite navigation systems with increased accuracy and reliability, as well as for solving a number of other problems of science and technology. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the measurement of pilot perceptual workload - A comparison of assessment techniques addressing sensitivity and intrusion issues

A flight simulator-based study was conducted to examine fourteen distinct mental workload estimation measures, including opinion, secondary task, physiological, and primary task measures. Both the relative sensitivity of the measures to changes in mental workload and the differential intrusion of the changes on primary task performance were assessed. The flight task was varied in difficulty by manipulation of the presentation rate and complexity of a hazard-perception task that required each of 48 licensed pilots to rely heavily on their perceptual abilities. Three rating scales (Modified Cooper-Harper, Multi-descriptor, and Workload-Compensation-Interference/Technical Effectiveness), two secondary task measures (time estimation and tapping regularity), one physiological measure (respiration frequency), and one primary task measure (danger-condition response time) were reliable indicants of workload changes. Recommendations for applying the workload measures are presented.

Casali, J. G.↗

Measuring Q And f(sub r) Of A Microwave Cavity: Part I

Method of measuring quality factor (Q) and frequency of resonance (f(subr)) of microwave cavity exploits two inflection points of power-vs.-frequency resonance curve of cavity. Intended particularly for use with microwave cavity in which sample of lossy dielectric material heated to specified high temperature by microwave power at resonant frequency. Accurate measurement contributes to enhanced monitoring and control in contactless high-temperature processing of materials. Also used with small spherical sample to determine temperature dependence of complex dielectric constant.

Barmatz, Martin B.↗

Vibratory response of a stiffened, floor equipped, composite cylinder

A structural modal analysis has been performed on a composite, filament wound cylindrical shell with floor, using a Computer Aided Test (CAT) system. The twelve foot (3.66 m) long shell is five and one half feet (1.68 m) in diameter and includes a half inch thick plywood floor attached to the shell 69 degrees from the vertical centerline through the bottom of the shell. The shell is composed of carbon fibers embedded in an epoxy resin. The cylinder is supported by two heavy, rigid endcaps simulating simply supported end conditions. Modal frequencies of the shell and floor have been extracted by measuring the frequency response functions from impulse excitation by an impact hammer. Reasonable agreement is obtained between the measured structural modal frequencies and mode shapes and analytical results from a computerized prediction model. The effects of floor location, fiber orientation, and skin thickness on the resonance frequencies of the shell and floor have been predicted for a stiffened and unstiffened cylinder.

Grosveld, Ferdinand W.↗