Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling supercritical CO2 injection induced rupture of a minor fault embedded in a poroelastic layered reservoir-caprock system

CO2 injection for geologic carbon sequestration involves hydromechanical processes that lead to changes in fluid pressure and stresses that can activate existing faults. This paper presents a new method and workflow of modeling fault activation considering more complex three-dimensional geometry of natural faults using the TOUGH-FLAC multiphase fluid flow and geomechanical simulator. In this method and workflow, FLAC3D mechanical interfaces and TOUGH3 finite volume elements are discretized using computer aided design and gridding software along with a tailored mesh translation routine. The method and workflow are demonstrated with a model of a curved minor fault embedded in a poro-elastic layered reservoir-caprock system. The model is used for a comprehensive sensitivity analysis of fault responses to fault length, injection mass rate, injection schedule, well-fault distance, and well locations versus fault location. Four metrics (CO2 plume, shear state of fault, pressure and stress path at fault monitoring points) are selected to assess CO2 migration, pressure change, and the reactivation of faults. The results reveal that CO2 can bypass around the tip of the minor impermeable fault, building up pressure and poro-elastic stress on both sides that tends to impede fault rupture. Our study shows the benefit of carefully designing the injection to achieve the targeted final storage volume, starting at a relatively low rate for considerable time, and then ramping up the injection rate to the full rate of injection. The initial low injection has two distinct benefits: (1) it allows for the formation of an extensive CO2 plume with a much higher mobility through a low viscosity that will result in a lower pressure for a given injection rate, and (2) it allows for gradual build-up of horizontal poro-elastic stress within the reservoir that will tend to impede activation of steeply dipping faults. The injection scenario starting at a low injection rate, denoted here as conservative injection, can significantly reduce the risk of fault activation as high fluid mobility and reservoir strengthening poro-elastic stress has been established long before reaching the peak injection rates. Moreover, simultaneous injection in two injection wells on both sides of fault can provide further reservoir strengthening through poro-elastic stress buildup acting on a fault under normal faulting stress regime. The findings presented in the paper can provide practical and effective guidance on long-term, safe, and reliable geological CO2 storage.

Cao, Meng↗

Deep reinforcement learning based optimization for a tightly coupled nuclear renewable integrated energy system

New ways to integrate energy systems to maximize efficiency are being sought to meet carbon emissions goals. Nuclear-renewable integrated energy system (NR-IES) concepts are a leading solution that couples a nuclear power plant with renewable energy, hydrogen generation plants, and energy storage systems, such that thermal and electrical power are dispatchable to fulfill grid-flexibility requirements while also producing hydrogen and maximizing revenue. Here, this paper introduces a deep reinforcement learning (DRL)-based framework to address the complex decision-making tasks for NR-IES. The objective is to maximize revenue by generating and selling hydrogen and electricity simultaneously according to their time-varying prices while keeping the energy flow in the subsystems in balance. A Python-based simulator for a NR-IES concept has been developed to integrate with OpenAI Gym and Ray/RLlib to enable an efficient and flexible computational framework for DRL research and development. Three state-of-the-art DRL algorithms have been investigated, including two-delayed deep deterministic policy gradient (TD3), soft-actor critic (SAC), proximal policy optimization (PPO), to illustrate DRL’s superiority for controlling NR-IES by comparing it with a conventional control approach, particle swarm optimization (PSO). In this effort, PPO has shown more-stable performance and also better generalization capability than SAC and TD3. Comparisons with PSO have demonstrated that, on average, PPO can achieve 13.9% more mean episode returns from the training process and 29.4% more mean episode returns from the testing process when different hydrogen-production targets are applied.

08 HYDROGEN↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D printing synthesis of catalysts

The catalyst industry generates approximately $20 billion every year globally and plays a major role in the energy production sector. Traditional industrial catalysts (e.g., pellets) typically have mass and heat transfer limitations, and cause a pressure drop in continuous-flow reactors, lowering the efficiency of the catalytic processes. 3D printing technology has evolved rapidly over the past decade, and the 3D printing of catalysts with desired geometries can address many of the above-stated challenges with traditional catalysts. However, challenges remain to be addressed and opportunities remain to be explored before the full potential in the design and 3D printing of novel catalysts can be realized. Herein this article reviews the recent development in the 3D printing of catalysts. It summarizes the 3D printing design, dimension, property, and performance of 3D printed catalysts. The applications of 3D printed catalysts, such as reforming, wastewater treatment, and CO 2 capture and removal, are discussed, with a techno-economic analysis and life cycle analysis. Future research directions and opportunities for 3D printing of catalysts are also highlighted.

25 ENERGY STORAGE↗

Stormwater Storage and Retention Within an Urban Prairie Wetland Complex

Climate change is expected to increase the frequency and severity of flooding in the Great Lakes region. In many cities, flood-control infrastructure is insufficient to protect against future climate conditions. Consequently, there is increasing focus on stormwater storage provided by urban greenspace, such as wetlands and prairies, but the ecohydrological behavior of these ecosystems is not well understood when they are embedded within cities. To improve understanding of hydrological connectivity between urban areas and natural greenspaces, we deployed a sensor network in Gensburg Markham Prairie (GMP), a large intact prairie-wetland complex in south suburban Chicago. We used the resulting high-frequency time-series data to assess surface-subsurface hydrologic dynamics between upland and low-lying wetland areas, interactions between the prairie and surrounding environment, and stormwater storage provided by the prairie. Rapid infiltration within the prairie during and after storm events provides subsurface flow that stores considerable water, flattens storm hydrographs, and increases the wetland hydroperiod. Much of the stormwater input to GMP derives from the surrounding cityscape. Consequently, storage within the prairie-wetland system reduces and slows stormwater discharge to downstream urban communities. For a typical 5-year 24-hr storm with 10.9 cm of rain, GMP stores 77,100 m 3 , 64% greater than the estimated direct rainfall volume onto the prairie, yielding 30,000 m 3 of offsite stormwater storage. This improved understanding of ecohydrological dynamics in urban prairies and wetlands informs the design and implementation of green infrastructure to meet growing needs for stormwater management.

Rivera, Vivien Anne [Northwestern University, Evan↗

Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020) (Rev. 2)

This document provides an updated Hanford Site composite analysis (CA). A Hanford Site CA was prepared and issued in 1998 (PNNL-11800) with an addendum provided in 2002 (PNNL-11800 Addendum 1). The CA was approved in 2002 (Frei, 2002) and has been maintained (DOE/RL-2000-29 and subsequent revisions) to support low-level waste disposal performance assessments (PAs) and disposal authorizations for facilities at the Hanford Site, including the following: Continued operation of the Environmental Restoration Disposal Facility (ERDF) and the 200 East and 200 West Low-Level Burial Grounds; Construction of the Integrated Disposal Facility (IDF); Forthcoming closure of tank residual waste systems such as Waste Management Area (WMA) C. The CA maintenance program resulted in a determination in 2015 (DOE/RL-2015-66) that the Hanford Site CA needed an update for the following reasons: While the initial Hanford Site CA has been maintained since 2001, the accumulation of basis changes reported in the annual summary reports over the succeeding 14 years merit evaluation in an updated analysis; The U.S. Department of Energy (DOE) Headquarters requested in a memorandum in 2015 (Gilbertson and Marcinowski, 2015) that “as soon as the relevant PAs are complete, the CA will be revised to account for all of the new information.” This updated Hanford Site CA accounts for the following new information: 1. Inclusion of a detailed Hanford Site baseline disposition that projects remedial activities through site closure. There have been significant changes through decision making in the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) process that were not available when the original CA was produced; 2. Inclusion of an updated inventory basis, new modeling capabilities, and new decisions reached in the associated record of decision (ROD) that was provided by issuance of DOE/EIS-0391 in fiscal year (FY) 2013. Development of a Hanford Site groundwater model from the baseline provided in a technical transfer of models for the Final Tank Closure and Waste Management Environmental Impact Statement (DOE/EIS-0391) commenced in FY 2014 and resulted in the plateau-to-river (P2R) groundwater flow model that is used in this updated Hanford Site CA; 3. Accounting for pump and treat systems, which were not evaluated in the initial CA. Pump and treat systems have had significant impact on groundwater flow system behavior, contaminant transport, and contaminant removal from Hanford Site groundwater. This process is accounted for in the use of the P2R model for this updated Hanford Site CA; 4. Inclusion of water-level data collected since the initial CA was completed. Data collected as the unconfined aquifer water levels continue to recede since the cessation of large liquid discharges in the late 1990s have led to marked improvement in understanding of the flow system for future conditions, particularly regarding northward flow potential in the critical Gable Gap area. The calibration in the latest version of the P2R model accounts for this information; 5. Inclusion of results from the revised ERDF PA completed in 2013 (WCH-5209) that account for updated inventory and expansion of the ERDF facility to about twice the size that was evaluated in the original CA; 6. Use of updated geoframeworks to provide the structural basis for numerical fate and transport models in the groundwater pathway of this updated CA. The geologic basis for groundwater models has continued to improve with additional data collection and interpretation with the creation and maintenance of the Hanford South Geoframework and the Central Plateau Vadose Zone Geoframework tools; 7. Incorporation of updated tank residual inventory estimates. Tank residual inventory estimates have improved with the incorporation of tank retrieval inventory data for those tanks that have completed retrieval. The CA inventory data package includes this updated information; 8. Incorporation of WMA C PA results. Two additional PAs for tank farm closure decisions are in preparation during the period required to prepare an updated Hanford Site CA: WMA C (FY 2016) and WMA A-AX (in preparation). The WMA C PA results are incorporated into the updated Hanford Site CA, and its grouted residuals model is used as the basis for a release model to account for the other tank farm systems modeling in this updated CA; 9. An update to the IDF PA was submitted in FY 2017 and has been reviewed and approved. The results of the IDF PA are incorporated into this updated CA; 10. Updated risk assessment scenarios. The risk assessment scenarios currently in use for Hanford Site CERCLA and Resource Conservation and Recovery Act of 1976 (RCRA) analyses differ from those evaluated in the initial Hanford Site CA. The representative person exposure scenario evaluated in this updated Hanford Site CA is consistent with recent PAs and CERCLA and RCRA analyses as the Hanford Site. This updated Hanford Site CA provides the following: A comparison of the updated Hanford Site CA all-pathway dose results with the performance measures during the compliance period, which is assumed to begin with site closure in calendar 2070 with the last scheduled disposal action and continue for 1,000 years postclosure (to calendar year 3069); A comparison of Hanford Site CA all-pathway dose results with the performance measures during the postcompliance period to address potential peaks beyond the compliance period. This is accomplished by evaluating dose in the period for 9,000 years following the compliance period (i.e., from calendar year 3070 to 12070).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamics and Heat Transfer Modeling of a Dimpled Heat Exchanger

Multiphysics and analytical calculations were conducted for a heat exchanger with passive, natural circulation flow. A glycol/water working fluid convects the heat to a dimpled heat exchanger shell, which subsequently transfers the heat to the soil, which acts as the ultimate heat sink. Because the system is fully-passive, it is not subject to the expenses, maintenance, and mechanical breakdowns associated with moving parts. Density, heat capacity, and thermal conductivity material properties were measured for various soil samples, and subsequently included as input for the soil heat conduction model. The soil model was coupled to a computational fluid dynamics (CFD) heat exchanger model that included the dynamic Smagorinsky large eddy simulation and k- omega turbulence models. The analysis showed that the fluid dynamics and heat transfer models worked properly, albeit at a slow pace. Nevertheless, the coupled CFD/heat conduction simulation ran long enough to determine a key parameter—the amount of heat conducted from the heat exchanger to the ground. This unique performance value, along with experimental data, was used as input for stand-alone, fast-running CFD models, as well as boundaries to obtain solutions to partial differential equations for soil heat conduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polyhedral Relaxations for Optimal Pump Scheduling of Potable Water Distribution Networks

The classic pump scheduling or optimal water flow (OWF) problem for water distribution networks (WDNs) minimizes the cost of power consumption for a given WDN over a fixed time horizon. In its exact form, the OWF is a computationally challenging mixed-integer nonlinear program (MINLP). It is complicated by nonlinear equality constraints that model network physics, discrete variables that model operational controls, and intertemporal constraints that model changes to storage devices. To address the computational challenges of the OWF, this paper develops tight polyhedral relaxations of the original MINLP, derives novel valid inequalities (or cuts) using duality theory, and implements novel optimization-based bound tightening and cut generation procedures. The efficacy of each new method is rigorously evaluated by measuring empirical improvements in OWF primal and dual bounds over 45 literature instances. The evaluation suggests that our relaxation improvements, model strengthening techniques, and a thoughtfully selected polyhedral relaxation partitioning scheme can substantially improve OWF primal and dual bounds, especially when compared with similar relaxation-based techniques that do not leverage these new methods.

bound tightening↗

Bulk Spray and Individual Plume Characterization of LPG and Iso-Octane Sprays at Engine-Like Conditions

This study presents experimental and numerical examination of directly injected (DI) propane and iso-octane, surrogates for liquified petroleum gas (LPG) and gasoline, respectively, at various engine like conditions with the overall objective to establish the baseline with regards to fuel delivery required for future high efficiency DI-LPG fueled heavy-duty engines. Sprays for both iso-octane and propane were characterized and the results from the optical diagnostic techniques including high-speed Schlieren and planar Mie scattering imaging were applied to differentiate the liquid-phase regions and the bulk spray phenomenon from single plume behaviors. The experimental results, coupled with high-fidelity internal nozzle-flow simulations were then used to define best practices in CFD Lagrangian spray models. Optical imaging revealed that unlike iso-octane, propane’s spray propagation was fed by its flash boiling, spray collapse, and high degree of vaporization, resulting in a direct proportionality of propane’s penetration length to temperature. These unique features of propane and its variation from iso-octane’s spray pattern, contributed to its classification as an unconventional spray. Appropriate corrections to the injection and breakup models were developed to reproduce the under-expanded jet dynamics and to mimic the flash boiling-driven spray development observed with propane sprays. The simulation results were found to be sensitive to cone and inclusion angles of the blob injector. The current work represents a first assessment of the capability of the commonly available models for engine-spray simulations and highlights the fact that, despite the reasonable agreement obtained in the fuel vapor morphology, the representation of the liquid phase lacks accuracy and requires further model development.

02 PETROLEUM↗

Integration and Optimization of a Waste Heat Driven Organic Rankine Cycle for Power Generation in Wastewater Treatment Plants

The study focuses on achieving energy self-sufficiency in Wastewater Treatment Plants by proposing a comprehensive model for integrating, sizing, and optimizing an Organic Rankine Cycle system. The Organic Rankine Cycle system is designed to utilize waste heat from the gensets at As Samra Wastewater Treatment Plant in Jordan, where it will contribute to the overall electrical energy supply of the plant. Real data from As Samra Wastewater Treatment Plant is used to model and calculate the available waste heat using TRNSYS® software. The Organic Rankine Cycle model is then developed using ASPEN PLUS® software to explore the impact of operational parameters and determine their optimal values for maximizing the plant's energy profile. An economic analysis is conducted to assess the feasibility of the proposed model, considering system components, installation, operation, and maintenance costs. To optimize the Organic Rankine Cycle system, the study employs the Multi-Output Support Vector Regression technique to capture nonlinear relationships between independent variables (fluid type, turbine inlet pressure, turbine inlet temperature, turbine outlet pressure, and mass flow rate) and dependent variables (pump power input, waste heat input, and turbine specific work). The Osprey optimization algorithm is used to address the multi-objective optimization problem, with the proposed Pareto-based Osprey Optimization Algorithm and the Multi-Objective Particle Swarm Optimization technique being employed to evaluate critical performance and economic parameters such as system thermal efficiency, net power output, and the levelized cost of electricity. The results of the optimization strategies indicate that the M-SVR model's prediction accuracy is significantly improved after parameter optimization, with the model returning high R 2 and low Mean Square Error values of 0.991 and 0.00216, respectively. The Pareto-Based Osprey Optimization Algorithm optimizer identifies the best working fluid as Isobutane/Isopentane in a ratio of 66:34, with optimal turbine inlet pressure and temperature of 15 bars and 218 °C, respectively. In conclusion, the Organic Rankine Cycle model at these optimal conditions achieves a cycle efficiency of 19.93% and an Levelized Cost of Electricity value of 0.0353 USD/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytic solutions for Asay foil trajectories with implications for ejecta source models and mass measurements

We consider the trajectory of an Asay foil ejecta diagnostic for scenarios where ejecta are produced at a singly shocked planar surface and fly ballistically through a perfect vacuum to the sensor. We do so by building upon a previously established mathematical framework derived for the analytic study of stationary sensors. First, we derive the momentum conservation equation for the problem, in a form amenable to accelerating sensors, in terms of a generic ejecta source model. The result is an integrodifferential equation of motion for the foil trajectory. This equation yields an easily calculable closed-form implicit solution for the foil trajectory in instant-production scenarios. From there, we derive a boundary condition that particle velocity distributions must satisfy if their associated foil trajectories are to exhibit a smooth initial acceleration, as occurs in some experiments. This condition is identical to one derived previously from a consideration of piezoelectric voltage data obtained in similar experiments. We also compare techniques for inferring accumulated ejecta masses from foil trajectories, first by deriving the exact solution, and then by quantifying the error imposed by a frequently used approximate solution (both subject to the assumption of instantaneous ejecta production). Finally, we examine the common practice of presenting inferred cumulative ejecta masses as a function of implied ejecta velocity, establishing the conditions under which this methodology is most meaningful.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗