Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Evaluation of Maximum Dose Rate Resulting from Failure of the Linac Charge Monitoring System

This evaluation was prepared in response to a request from the Accelerator Readiness Review Team for NSLS-II Routine Operations. The purpose of this evaluation is to document the maximum dose rate potential for failures in the linac charge monitoring system. It is noted that the probability of such a failure is extremely low and likely never realized. For the failure to occur, the linac injection has to be set to maximum output, monitoring devices as displayed in the Control Room would go unnoticed by the Operators, the Operator on duty would have to fail to recognize the event, other accumulating charge monitors that alarm at ASE limits would also need to fail or would have to go unrecognized by the Operator and finally there would have to be a simultaneous fault in the storage ring to generate dose on the experimental floor. Regardless of these multiple layers of protection, the maximum dose rate to staff on the NSLS-II experimental floor is presented below.

36 MATERIALS SCIENCE↗

235-F Deactivation and Decommissioning: Inventory and Scenarios

Facility inventory has a significant influence on the fate and transport modeling of 235-F. This memorandum details the proposed source inventory for 235-F for verification from 235-F Risk Reduction (see Tables 7 and 9) and specifies two scenarios that will be investigated using GoldSim and PORFLOW as follows: grout the entire first floor (including the area directly below PuFF cells), and grout the entire first and second floors (including the area directly below PuFF cells).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

April Burn-in Testing Report for Genentech B35, South San Francisco Campus

Genentech and Webcor reserved a thirty-day “burn-in” period after completion of the commissioning phase to conduct a detailed evaluation of all systems in the new HTA B35 building prior to occupancy. During this period, LBNL evaluated the automated shading and dimmable indoor lighting control systems to determine whether the systems were working according to design intent. LBNL also evaluated lighting energy use and visual and thermal comfort in the perimeter zones. LBNL conducted the monitored evaluation in four perimeter zones on the 7th floor from March 25th to May 7th, 2015. The daylight and tuning control functions of the dimmable LED direct-indirect lighting control system were evaluated and then adjusted in collaboration with the electrical contractor (Redwood Electric) during the first three weeks of the evaluation. The lighting controls were then considered to be operating as expected after April 20th and a detailed evaluation of control performance and energy use was conducted thereafter. The automated shading system was assessed over a limited period (April 15-30) on both the 6th and 7th floors to determine whether the controls raised the shade when discomfort glare was imperceptible. After a few days of analysis, changes were made to the settings to admit more daylight by changing both the glare sensor threshold and by increasing the depth of direct sun ingress from 36” to 48” from the façade on all orientations except the east.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is the BPD Nationally Representative? A Comparison of the Building Performance Database to the Commercial Buildings Energy Consumption Survey

The Building Performance Database (BPD) contains building characteristics and energy use data that can be used to benchmark buildings against their peers. However, the BPD contains data from any source that was willing to contribute data, regardless of whether that dataset is representative of the national building stock. This report explores the representativeness of the BPD. Namely, we compared the BPD to the Commercial Buildings Energy Consumption Survey (CBECS), which was designed to be a nationally representative sample of buildings. We divided the datasets into subgroups based on building type and location, we focused on three key variables (floor area, site energy use intensity, and source energy use intensity), and we compared their statistical properties in the BPD to the CBECS. We found that while the BPD contains significantly more buildings with larger floor areas, the BPD is reasonably representative in terms of site and source energy use intensity and does not appear to have a systemic bias towards energy efficient buildings.

42 ENGINEERING↗

SNL API-653 In-Service Tank Inspection and Evaluation Tank ID: 981-A2-T0 (West)

An API Standard 653 In-Service inspection was completed on Tank 981-A2-T0 (West) located at the Sandia National Laboratories TAIV tank farm in Albuquerque, NM on September 22, 2015. The inspection was completed to collect data to evaluate the mechanical integrity and fitness for continued service of the tank. No indication or records of any previous inspection were identified for this tank. The inspection and engineering evaluation were completed using API-653, 5 th Edition and conservative engineering practices. The tank was not removed from service, so an internal inspection could not be completed. The tank was also fully insulated. The insulation was removed in specified areas of the tank shell and tank chime to accommodate an acoustic emission scan of the tank and an ultrasonic thickness evaluation of portions of the tank. The acoustic emission scan resulted in a grade of B / I - II indicating an overall TANKPAC grade B and composite grade II indicating minor active damage with highly concentrated sources related to corrosion found in the southeast and west side section of the tank. Eight Potential Localized Damage sources were found mainly in the west side (re-test in 2 years). The tank chime could not be inspected due to the configuration of the insulation welded angle support. An ultrasonic guided bulk wave inspection was completed on the tank shell to assess the lower shell section. At the time of the inspection the limited data collected showed minimal material loss from the shell at the thickness monitoring locations, however, visual inspection and pit depth gauge measurements showed > 3/16” inch pitting and significant general external surface corrosion on the shell at the shell to floor joint. This corrosion is caused by the insulation sheeting support welded angle iron trapping moisture and dirt against the tank shell. This tank should be removed from service, internally inspected, and repaired. Ultrasonic thickness measurement locations were established on this tank and the data is included in this report. The limited data collected indicated minimal material loss at these locations, with the only noted corrosion occurring on the tank shell to floor joint as noted above. An API-653 Annex B Evaluation of Tank Bottom Settlement was completed and the results are included in this report. No significant settlement issues were identified.

42 ENGINEERING↗

University of Washington Harborview Research and Training Building Environmental Sample Plan for Cs-137 in Soils and Sediments

On May 2, 2019, a release of Cs-137 from a breached sealed source containing 2,800 curies (Ci) (1E14 Bq) of Cesium-137 (Cs-137) occurred at the University of Washington (UW) Harborview Research and Training Building (HRB). The release occurred during removal of the source from its holder within a portable hot cell in the second floor loading dock area. The loading dock and northeast corner of the building above the ground floor were heavily impacted by the release, while the remaining portions of the building and the exterior of the building were minimally impacted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s second mobile facility (AMF2) Aerosol Observing System, designated AOS02, entered service in October of 2010 at Steamboat Springs, Colorado for the Storm Peak Laboratory Cloud Property Validation Experiment (StormVEx). The Aerosol Observing S ystem is meant to be a standalone, autonomous, aerosol sampling system. It requires only power, 208 or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s AMF3 AOS, designated AOS03, entered service in August of 2016 at the ARM Mobile Facility at Oliktok Point, Alaska. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Eastern North Atlantic (ENA) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s ENA AOS, designated AOS06, entered service in October of 2013 at the ARM Facility on Graciosa Island, Azores. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Building Energy Codes Program: National Benefits Assessment (1992-2040)

Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, assuring reductions in energy use and greenhouse gas emissions over the life of buildings. DOE, through the Building Energy Codes Program, supports the improvement of energy efficiency in buildings. BECP periodically assesses the impacts of its activities by estimating historical and projected energy savings, consumer savings, and avoided emissions. The Pacific Northwest National Laboratory conducted the codes benefits assessment in support of the BECP. Underlying the assessment is a series of calculations that estimate and compare energy savings under two scenarios: "with BECP" and "without BECP." The analysis covers the years 1992-2040 and includes comparing the nominal energy savings (assuming 100 percent adoption and compliance) attributable to different code versions, determining the applicable floor space (both residential and commercial) subject to the code, and estimating the final energy savings by adjusting nominal energy savings for the applicable floor space according to the estimated actual adoption and compliance levels. The resulting estimates of energy consumption for each scenario are compared, and the difference equals the impact of BECP activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Salt Repository Concept for CSNF in 21-PWR Size Canisters

The most straightforward concept for disposal of large, heavy packages containing commercial spent nuclear fuel (CSNF) in a repository in bedded salt, would be to emplace them directly on the floor in emplacement tunnels. In-tunnel axially aligned horizontal emplacement would minimize excavated volume and avoid drilling of large-diameter emplacement boreholes. A similar concept was proposed in Germany for direct disposal of POLLUX ® canisters. The repository would be constructed at a depth of 500 to 1,000 m for isolation from the surface, and for sufficient overburden stress to ensure creep reconsolidation of repository openings. It could entail modular panels of emplacement tunnels arranged on headings oriented in cardinal directions from a central core, to accommodate the estimated 140,000 MTU total U.S. CSNF inventory. To do so, the overall area of the repository layout would be approximately 20 km 2 . Many layouts are possible, but the approach should be modular, excavation should be deferred for as long as possible to avoid maintenance, and the emplacement areas should share support facilities and shafts. Vertical shafts would be used in accordance with mining practice in sedimentary basins. Large diameter shafts would be needed for ventilation exhaust and waste transport, with smaller shafts for waste salt removal, men & materials, and ventilation intake. The spacing between disposal tunnels as estimated from thermal modeling, seeks to limit the maximum average areal thermal load in the panels to 11 W/m 2 to control long-term heat buildup in the host rock. Peak salt temperature would occur within a few years and would be dominated by each waste package locally, simplifying thermal management. There would be some flexibility to decrease the package spacing or increase the emplacement thermal power limit Backfilling emplaced waste packages immediately with mine-run crushed salt would provide shielding and expedite reconsolidation. This arrangement would isolate adjacent waste packages from one another by the intervening backfill, especially after it reconsolidates and its properties approach those of intact salt. After the repository is fully loaded and the performance confirmation program is complete, activities to permanently close the repository would be initiated. During closure operations all openings in the host salt would be backfilled, then shafts would be sealed, and boreholes plugged. Plans for the Waste Isolation Pilot Plant (WIPP) show how sealing and plugging could be done. A monitoring program could continue for 50 years or longer after repository closure. With an emplacement thermal power limit of 10 kW per waste package, nearly all the CSNF that is projected to be produced by the current fleet of reactors in the U.S. could be emplaced over a period of approximately 50 years starting in calendar 2048. No barriers to implementation in a reasonable timeframe have been identified from this generic analysis. Engineering challenges include: 1) shaft construction; 2) a very-large capacity shaft hoist; 3) overpack design; 4) a transport-emplacement-vehicle (TEV) for transporting waste packages once they are underground and emplacing them remotely; and 5) remotely operated equipment for emplacing backfill. The method of shaft construction would depend on site-specific conditions, and could involve freezing the subsurface. A shaft hoist with payload capacity of 175 MT seems technically and economically feasible based on development work in Germany, and it would be the largest hoist of its kind. The function of disposal overpacks would be to provide reliable containment during repository operations, which could be accomplished using a corrosion allowance material such as a low-carbon steel. Development effort would be needed to determine overpack thickness (e.g., 7 to 20 cm) that can resist corrosion and loading from salt creep, to rovide containment throughout the repository operational period. The transport-emplacement vehicle (TEV) would be similar to previous concepts, particularly one option proposed for a Yucca Mountain repository. It would move over a rough salt floor on independently driven and steered wheels, and carry heavy shielding in addition to a waste package. By analogy to the safety case for the WIPP in New Mexico, human intrusion is likely to be the dominant mode of radionuclide release from the repository. Treatment of human intrusion for a CSNF repository in salt could depend on promulgation of site-specific changes in the regulations. Radionuclide release and migration would be quite limited for undisturbed conditions. There may be opportunities for improved understanding of salt performance with waste heating, based on future in situ testing in an underground salt research laboratory. This report also discusses a developing area of salt rock mechanics that involves low-stress, low strain-rate creep that might cause large, heavy waste packages to slowly sink. Site-specific sampling, testing, and modeling would be used to determine if the mechanism is important enough to merit consideration in design, or inclusion in performance assessment. Part of engineering design and postclosure safety assessment for a CSNF repository in salt would be to implement a methodology to show that the probability of a criticality event in the repository, when waste packages eventually breach and are flooded, is less than the probability screening threshold for performance assessment. In the methodology, a criticality analysis would be performed for waste packages in the repository, incorporating measures that could be introduced as needed to limit reactivity, for example using fuel selection and loading rules, and crediting the absorption of thermal neutrons by natural chlorine in the environment. A similar analysis has been underway for CSNF stored in dual-purpose canisters. Ideally the strategy would be developed prior to actually loading SNF assemblies into canisters used in waste packages for disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scat Detection Dog Surveys for the San Joaquin Kit Fox on the Lawrence Livermore National Laboratory's Experimental Test Site (Site 300) and the Corral Hollow Ecological Reserve: 2020 Deployment

The San Joaquin kit fox (Vulpes macrotis mutica) historically occupied an extensive range in the San Joaquin Valley, California; however, their populations and habitat have since been significantly reduced by human impacts (United States Fish and Wildlife Service [USFWS] 1998). More than 95% of the potential habitat for kit foxes on the San Joaquin Valley floor has been converted to irrigated agriculture, urbanized, or industrialized lands. The San Joaquin kit fox was listed as endangered by the USFWS in 1967 and as threatened by the State of California in 1971. Records from local surveys, research projects, and incidental sightings indicate the present distribution of kit foxes extends from 1) southern Kern County north to Contra Costa, Alameda, and San Joaquin counties on the west side of the valley and to Stanislaus County on the east side; 2) into some of the larger, uncultivated valley-floor land parcels in Kern, Tulare, Kings, Fresno, Madera, and Merced counties; and 3) westward within 5 counties in the interior coastal range (USFWS 1998). Kit foxes have been denoted to occur in 3 geographically distinct core and several satellite populations in a heavily fragmented landscape, with the largest extant populations concentrated in the southern part of the range and smaller populations and isolated sightings in the central and northern portions (USFWS 1998, 2010).

54 ENVIRONMENTAL SCIENCES↗

A Compilation of Historical Data on Hagan Drop Testing with Results

The Hagan nuclear material storage container was designed in the late 1990’s to provide a robust container for daily use, safe transport within the plutonium facility PF-4, and storage of nuclear material for up to twenty years. There are currently >3000 loaded Hagan containers in use at TA-55. The majority of these are in the TA-55 vault, but they are also used in safes and in floor locations on the main floor of PF-4. The original design criteria are given below

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cavern Leaching Monitoring CY18 And CY19

The U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system run by the U.S. Department of Energy (DOE). The reserve consists of 60 active storage caverns spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR began executing U.S. congressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 MMB, requires raw water to be used instead of saturated brine for oil withdrawals such as for sales. All sales will produce leaching within the caverns used for oil delivery. Thirty-six caverns had a combined total of over 29 MMB of water injected from CY18-CY19 for mandatory sales. Leaching effects were monitored in these caverns to understand how the sales operations may impact the long-term integrity of the caverns. While frequent sonars are the best way to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An intermediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code (SANSMIC). The results indicate that leaching induced features are not of concern in the majority of the caverns, 32 of 36. Four caverns, BH-107, BH-108, BH-114 and WH-114 have features that may grow with additional leaching and should be monitored as leaching continues in those caverns. Six caverns had post sale sonars which were compared with SANSMIC results. SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results suggest SANSMIC is a useful tool for monitoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Strategic Petroleum Reserve Cavern Leaching Monitoring CY20

The U.S. Strategic Petroleum Reserve is a crude oil storage system run by the U.S. Department of Energy. The reserve consists of 60 active storage caverns spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR began executing U.S. congressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 MMB, requires raw water to be used instead of saturated brine for oil withdrawals such as for sales. All sales will produce leaching within the caverns used for oil delivery. Twenty-five caverns had a combined total of over 39 MMB of water injected in CY 20 as part of the Exchange for Storage program; oil was withdrawn in the same manner as for congressionally mandated sales. Leaching effects were monitored in these caverns to understand how the oil withdrawals may impact the long-term integrity of the caverns. While frequent sonars are the best way to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An intermediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code (SANSMIC) . The results indicate that leaching induced features are not of concern in the majority of the caverns, 19 of 25. Six caverns, BH-107, BH-113, BH-114, BM-4, BM-106, and WH-114 have features that may grow with additional leaching and should be monitored as leaching continues in those caverns. Ten caverns had post sale sonars that were compared with SANSMIC results. SANSMIC was able to capture the leaching well , particularly the formation of shelves and flares. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results suggest SANSMIC is a useful tool for monitoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Strategic Petroleum Reserve Cavern Leaching Monitoring CY21

Th e U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system administered by the U.S. Department of Energy. The reserve consists of 60 active storage caverns located in underground salt domes spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR started executing C ongressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 million barrels ( MMB ) , re quires that unsaturated water (referred to herein as ?raw? water) is injected into the storage caverns to displace oil for sales , exchanges, and drawdowns . As such, oil sales will produce cavern growth to the extent that raw water contacts the salt cavern walls and dissolves (leaches) the surrounding salt before reaching brine saturation. SPR injected a total of over 45 MMB of raw water into twenty - six caverns as part of oil sales in CY21 . Leaching effects were monitored in these caverns to understand how the sales operations may impact the long - term integrity of the caverns. While frequent sonars are the most direct means to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An interm ediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code , SANSMIC . The modeling results indicate that leaching - induced features do not raise co ncern for the majority of the caverns, 15 of 26. Eleven caverns, BH - 107, BH - 110, BH - 112, BH - 113, BM - 109, WH - 11, WH - 112, WH - 114, BC - 17, BC - 18, and BC - 19 have features that may grow with additional leaching and should be monitored as leaching continues in th ose caverns. Additionally, BH - 114, BM - 4, and BM - 106 were identified in previous leaching reports for recommendation of monitoring. Nine caverns had pre - and post - leach sonars that were compared with SANSMIC results. Overall, SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results validate that SANSMIC continues to serve as a useful tool for mon itoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗