Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Expert System (TEXSYS): Systems automony demonstration project, volume 1. Overview

The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS test bed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

Glass, B. J.↗

Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results

The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

Glass, B. J.↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Fault-tolerance experiments with the JPL STAR computer.

Results of fault-tolerance experiments performed using an experimental computer with dynamic (standby) redundancy, including replaceable subsystems and a 'program rollback' provision to eliminate transient-caused errors. After a brief review of the specification of fault-tolerance with respect to transient faults, including a description of the method of injection of transient faults in software and system tests, fault-tolerance experiments carried out with this computer with regard to the determination of fault classes, software verification, system verification, and recovery stability are summarized. A test and repair processor is described which constitutes a special monitor unit of the computer and is used to obtain information for fault detection in the other subsystems of the computer and to ensure that proper recovery occurs when a fault is detected.

Avizienis, A.↗

Common Faults and Their Prioritization in Small Commercial Buildings: February 2017 - December 2017

To support an ongoing project at NREL titled 'An Open, Cloud-Based Platform for Whole-Building Fault Detection and Diagnostics' (work breakdown structure number 3.2.6.18 funded by the Department of Energy Building Technologies Office), this report documents faults that are commonly found in small commercial buildings (with a floor area of 10,000 ft2 or less) based on a literature review and discussions with building commissioning experts. It also provides a list of prioritized faults based on an estimation of the prevalence, energy impact, and financial impact of each fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

This guide presents an overview of the top energy-savings opportunities in commercial buildings and shows how they can be identified using the type of interval meter analytics offered in energy information system technologies or using the automated analytics offered in fault detection and diagnostics systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Detection of Electric Power Troubles (ADEPT)

ADEPT is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system, and is designed for two modes of operation: real-time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a Laser printer. This system consists of a simulated Space Station power module using direct-current power supplies for Solar arrays on three power busses. For tests of the system's ability to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three busses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modelling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base. A load scheduler and a fault recovery system are currently under development to support both modes of operation.

Wang, Caroline↗

Flight test of a full authority Digital Electronic Engine Control system in an F-15 aircraft

The Digital Electronic Engine Control (DEEC) system considered is a relatively low cost digital full authority control system containing selectively redundant components and fault detection logic with capability for accommodating faults to various levels of operational capability. The DEEC digital control system is built around a 16-bit, 1.2 microsecond cycle time, CMOS microprocessor, microcomputer system with approximately 14 K of available memory. Attention is given to the control mode, component bench testing, closed loop bench testing, a failure mode and effects analysis, sea-level engine testing, simulated altitude engine testing, flight testing, the data system, cockpit, and real time display.

Barrett, W. J.↗

The Design of a Fault-Tolerant COTS-Based Bus Architecture for Space Applications

The high-performance, scalability and miniaturization requirements together with the power, mass and cost constraints mandate the use of commercial-off-the-shelf (COTS) components and standards in the X2000 avionics system architecture for deep-space missions. In this paper, we report our experiences and findings on the design of an IEEE 1394 compliant fault-tolerant COTS-based bus architecture. While the COTS standard IEEE 1394 adequately supports power management, high performance and scalability, its topological criteria impose restrictions on fault tolerance realization. To circumvent the difficulties, we derive a "stack-tree" topology that not only complies with the IEEE 1394 standard but also facilitates fault tolerance realization in a spaceborne system with limited dedicated resource redundancies. Moreover, by exploiting pertinent standard features of the 1394 interface which are not purposely designed for fault tolerance, we devise a comprehensive set of fault detection mechanisms to support the fault-tolerant bus architecture.

Chau, Savio N.↗

KEA-71 Smart Current Signature Sensor (SCSS)

This slide presentation reviews the development and uses of the Smart Current Signature Sensor (SCSS), also known as the Valve Health Monitor (VHM) system. SCSS provides a way to not only monitor real-time the valve's operation in a non invasive manner, but also to monitor its health (Fault Detection and Isolation) and identify potential faults and/or degradation in the near future (Prediction/Prognosis). This technology approach is not only applicable for solenoid valves, and it could be extrapolated to other electrical components with repeatable electrical current signatures such as motors.

Perotti, Jose M.↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation

Automated fault detection and diagnosis (AFDD) tools based on machine-learning algorithms hold promise for lowering cost barriers for AFDD in small commercial buildings; however, access to high-quality training data for such algorithms is often difficult to obtain. To fill the gap in this research area, this study covers the development (Part I) and validation (Part II) of fault models that can be used with the building energy modeling software EnergyPlus® and OpenStudio® to generate a cost-effective training data set for developing AFDD algorithms. Part II (this paper) first presents a methodology of validating fault models with OpenStudio and then presents validation results, which are compared against measurements from a reference building. We discuss the results of our experiments with eight different faults in the reference building (a total of 39 different baseline and faulted scenarios), including our methodology for using fault models along with the reference building model to simulate the same faulted scenarios. Then, we present validation of the fault models by comparing results of simulations and experiments either quantitatively or qualitatively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of an Enhanced Bank of Kalman Filters for In-Flight Aircraft Engine Sensor Fault Diagnostics

In this paper, an approach for in-flight fault detection and isolation (FDI) of aircraft engine sensors based on a bank of Kalman filters is developed. This approach utilizes multiple Kalman filters, each of which is designed based on a specific fault hypothesis. When the propulsion system experiences a fault, only one Kalman filter with the correct hypothesis is able to maintain the nominal estimation performance. Based on this knowledge, the isolation of faults is achieved. Since the propulsion system may experience component and actuator faults as well, a sensor FDI system must be robust in terms of avoiding misclassifications of any anomalies. The proposed approach utilizes a bank of (m+1) Kalman filters where m is the number of sensors being monitored. One Kalman filter is used for the detection of component and actuator faults while each of the other m filters detects a fault in a specific sensor. With this setup, the overall robustness of the sensor FDI system to anomalies is enhanced. Moreover, numerous component fault events can be accounted for by the FDI system. The sensor FDI system is applied to a commercial aircraft engine simulation, and its performance is evaluated at multiple power settings at a cruise operating point using various fault scenarios.

Kobayashi, Takahisa↗

DALG: A program for test pattern generation in combinational logical circuits

A user's manual for a computer program DALG which generates test patterns for detecting faults in combinational logic circuits containing up to 200 logical gates is presented. The gates may be of logical types AND, OR, NAND, NOR, NOT, or Exclusive OR is presented. The faults may be any one gate or input struck at a fixed value (0 or 1). In addition to test pattern generation DALG will also determine whether or not the given test pattern will detect given faults in a circuit. Sample problems are given along with input data sheets and printed output to illustrate the capabilities of the program.

Source record↗

Performance Evaluation of a Novel Sequence-Based Directional Detection Strategy for Protection of Active Distribution Networks

Directional elements are relied on to achieve selectivity in fault detection in power systems. Although such elements have been deployed successfully for many years, there is an increased need for novel methods to deal with the unique challenges of directional protection in modern distribution networks. This article analyzes the impact of inverter-based resources (IBRs) on existing directional protection methods in distribution systems. It identifies parts of such elements that pose a risk of misoperation when IBRs are used in distribution networks. The authors have developed a new directional detection method for unbalanced faults in such networks using superimposed symmetrical sequence quantities. The phase angle of the superimposed negative sequence admittance is used to determine fault direction. The paper also presents a real-time co-simulation platform between a simulated distribution system and physical protection relay, using OPAL-RT. An SEL-411L relay is used to program the detection algorithm. This hardware-in-the-loop (HIL) setup is used to verify the performance of the method and the results are compared with existing directional methods

24 POWER TRANSMISSION AND DISTRIBUTION↗