Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Apparatus including a plurality of spaced transformers for locating short circuits in cables

A cable fault locator is described for sensing faults such as short circuits in power cables. The apparatus includes a plurality of current transformers strategically located along a cable. Trigger circuits are connected to each of the current transformers for placing a resistor in series with a resistive element responsive to an abnormally high current flowing through that portion of the cable. By measuring the voltage drop across the resistive element, the location of the fault can be determined.

Cason, R. L.↗

Intelligent Automation Approach for Improving Pilot Situational Awareness

Automation in the aviation domain has been increasing for the past two decades. Pilot reaction to automation varies from highly favorable to highly critical depending on both the pilot's background and how effectively the automation is implemented. We describe a user-centered approach for automation that considers the pilot's tasks and his needs related to accomplishing those tasks. Further, we augment rather than replace how the pilot currently fulfills his goals, relying on redundant displays that offer the pilot an opportunity to build trust in the automation. Our prototype system automates the interpretation of hydraulic system faults of the UH-60 helicopter. We describe the problem with the current system and our methodology for resolving it.

Spirkovska, Lilly↗

A Scalable Test-Bed for Direct Current Current Transformer Automated Functional Testing and Characterization

This article describes a scalable test-bed for automation of measurements of the direct current current transformers (DCCT). Automation of measurement involves functional measurements, fault event based measurements and data validation. The test-bed is designed to measure up to 20 DCCTs at a time with software based measurement repetition checks and validation of the measurements.

43 PARTICLE ACCELERATORS↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-Based Fault Diagnosis for Turboshaft Engines

Tests are described which, when used to augment the existing periodic maintenance and pre-flight checks of T700 engines, can greatly improve the chances of uncovering a problem compared to the current practice. These test signals can be used to expose and differentiate between faults in various components by comparing the responses of particular engine variables to the expected. The responses can be processed on-line in a variety of ways which have been shown to reveal and identify faults. The combination of specific test signals and on-line processing methods provides an ad hoc approach to the isolation of faults which might not otherwise be detected during pre-flight checkout.

Green, Michael D.↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Adaptive Sampling using Support Vector Machines

Reliability/safety analysis of stochastic dynamic systems (e.g., nuclear power plants, airplanes, chemical plants) is currently performed through a combination of Event-Tress and Fault-Trees. However, these conventional methods suffer from certain drawbacks: • Timing of events is not explicitly modeled • Ordering of events is preset by the analyst • The modeling of complex accident scenarios is driven by expert-judgment For these reasons, there is currently an increasing interest into the development of dynamic PRA methodologies since they can be used to address the deficiencies of conventional methods listed above.

99 GENERAL AND MISCELLANEOUS↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Designing a Scalable Fault Tolerance Model for High Performance Computational Chemistry: A Case Study with Coupled Cluster Perturbative Triples

In the last couple of decades, the massive computational power provided by the most modern supercomputers has resulted in simulation of higher order computational chem- istry methods, previously considered intractable. As the system sizes continue to increase, computational chemistry domain continues to escalate this trend using parallel comput- ing with programming models such as Message Passing Interface (MPI) and Partitioned Global Address Space (PGAS) programming models such as Global Arrays. The ever increasing scale of these supercomputers comes at a cost of reduced mean time between failures, currently in the order of days, and projected to be in the order of hours for up- coming extreme scale systems. While traditional disk based checkpointing methods are ubiquitous for storing intermediate solutions, they suffer from high overhead of writing and recovering from checkpoints. In practice, checkpointing itself often brings the system down. Clearly, methods beyond checkpointing are imperative to handling the aggravating issue of reducing MTBF. In this paper, we address this challenge by designing and im- plementing an efficient fault tolerant version of coupled cluster method with NWChem, using in memory data redundancy. We present the challenges associated with our de- sign including efficient data storage model, maintenance of at least one consistent data copy and the recovery process. Our performance evaluation without faults shows that the current design exhibits negligible overhead. In the presence of a fault, the proposed design incurs negligible overhead in comparison to the state of the art implementation without faults.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assurance of Fault Management: Risk-Significant Adverse Condition Awareness

Fault Management (FM) systems are ranked high in risk-based assessment of criticality within flight software, emphasizing the importance of establishing highly competent domain expertise to provide assurance for NASA projects, especially as spaceflight systems continue to increase in complexity. Insight into specific characteristics of FM architectures seen embedded within safety- and mission-critical software systems analyzed by the NASA Independent Verification Validation (IVV) Program has been enhanced with an FM Technical Reference (TR) suite. Benefits are aimed beyond the IVV community to those that seek ways to efficiently and effectively provide software assurance to reduce the FM risk posture of NASA and other space missions. The identification of particular FM architectures, visibility, and associated IVV techniques provides a TR suite that enables greater assurance that critical software systems will adequately protect against faults and respond to adverse conditions. The role FM has with regard to overall asset protection of flight software systems is being addressed with the development of an adverse condition (AC) database encompassing flight software vulnerabilities.Identification of potential off-nominal conditions and analysis to determine how a system responds to these conditions are important aspects of hazard analysis and fault management. Understanding what ACs the mission may face, and ensuring they are prevented or addressed is the responsibility of the assurance team, which necessarily should have insight into ACs beyond those defined by the project itself. Research efforts sponsored by NASAs Office of Safety and Mission Assurance defined terminology, categorized data fields, and designed a baseline repository that centralizes and compiles a comprehensive listing of ACs and correlated data relevant across many NASA missions. This prototype tool helps projects improve analysis by tracking ACs, and allowing queries based on project, mission type, domain component, causal fault, and other key characteristics. The repository has a firm structure, initial collection of data, and an interface established for informational queries, with plans for integration within the Enterprise Architecture at NASA IVV, enabling support and accessibility across the Agency. The development of an improved workflow process for adaptive, risk-informed FM assurance is currently underway.

Software Verification & Validation↗

The Geomechanics of CO 2 Storage in Deep Sedimentary Formations

This study provides a review of the geomechanics and modeling of geomechanics associated with geologic carbon storage (GCS), focusing on storage in deep sedimentary formations, in particular saline aquifers. The paper first introduces the concept of storage in deep sedimentary formations, the geomechanical processes and issues related with such an operation, and the relevant geomechanical modeling tools. This is followed by a more detailed review of geomechanical aspects, including reservoir stress-strain and microseismicity, well integrity, caprock sealing performance, and the potential for fault reactivation and notable (felt) seismic events. Geomechanical observations at current GCS field deployments, mainly at the In Salah CO 2 storage project in Algeria, are also integrated into the review. The In Salah project, with its injection into a relatively thin, low-permeability sandstone is an excellent analogue to the saline aquifers that might be used for large scale GCS in parts of Northwest Europe, the U.S. Midwest, and China. Some of the lessons learned at In Salah related to geomechanics are discussed, including how monitoring of geomechanical responses is used for detecting subsurface geomechanical changes and tracking fluid movements, and how such monitoring and geomechanical analyses have led to preventative changes in the injection parameters. Recently, the importance of geomechanics has become more widely recognized among GCS stakeholders, especially with respect to the potential for triggering notable (felt) seismic events and how such events could impact the long-term integrity of a CO 2 repository (as well as how it could impact the public perception of GCS). As described in the paper, to date, no notable seismic event has been reported from any of the current CO 2 storage projects, although some unfelt microseismic activities have been detected by geophones. However, potential future commercial GCS operations from large power plants will require injection at a much larger scale. In conclusion, for such large-scale injections, a staged, learn-as-you-go approach is recommended, involving a gradual increase of injection rates combined with continuous monitoring of geomechanical changes, as well as siting beneath a multiple layered overburden for multiple flow barrier protection, should an unexpected deep fault reactivation occur.

54 ENVIRONMENTAL SCIENCES↗

A Convolution Neural Network for Voltage Event Classification at a Photovoltaic Inverter

This paper presents a convolutional neural network (CNN) developed to identify voltage events in photovoltaic (PV) inverters. The CNN is trained on synthetic data generated using the IEEE 13-bus distribution feeder model and evaluated on field measured data collected from Energy Northwest’s Horn Rapids Solar, Storage, and Training (HRSST) facility. The study focuses on two common voltage events: faults and voltage sags. The CNN is configured to analyze voltage and current waveforms from three-phase PV systems, demonstrating excellent accuracy during training. Field data from the HRSST facility is employed to assess its real-world performance, where the CNN achieves perfect identification of faults and voltage sags in a sample of nine events. This work highlights the potential of the proposed method to enhance PV protection schemes, providing a robust foundation for improved voltage event detection and grid reliability.

Cornachione, Matthew A.↗

Improving EV Charger Resiliency for MW Charging Systems

In this paper, the resiliency of a megawatt-scale EV charging station is investigated. Fault detection and tolerance methodologies are presented, based on monitoring the voltage offsets in DABs and switch-level currents in three-phase inverters, with the goal of maintaining operation at rated power during single faults and at reduced power under multiple fault conditions. To validate the effectiveness of the proposed strategy, simulation results at the rated 1 MW power of the charging station are carried out, followed by controller hardware-in-the-loop (CHIL) experiments on a 250 kW section of the station. The results highlight the feasibility of the integrated fault-tolerant methods for resilient, high-power EV charging infrastructure.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

Comparison and Discussion on Shortcircuit Protections for Silicon-Carbide MOSFET Modules: Desaturation Versus Rogowski Switch-Current Sensor

Survivability of silicon-carbide (SiC) mosfet modules during short circuit (SC) is essential for modern power electronics systems due to large economic implications. SiC mosfet modules exhibit narrow SC withstand times and generally much lower SC robustness than silicon (Si) insulated-gate bipolar transistors (IGBTs). This puts a critical concern on their utilization, further stressing the importance of reliable protection. This article presents a comprehensive analysis and discussion on the SiC mosfet module SC protection and performance comparison between conventional desaturation detection, previously used for Si IGBT protection, and Rogowski switch-current sensor (RSCS) detection. In addition, this article presents the experimental design for soft turn-off as a reaction to the SC detection to avoid excessive overshoots during the abrupt turn-off of the SC current. To perform different types of SC with various fault inductances on different temperatures, and for the sake of fair comparison under the same conditions, a gate-driver unit for 1.2 kV SiC mosfet half-bridge modules is developed containing both detection methods. The results demonstrate that both methods are successful in protecting the module in all SC types, with superiority of the RSCS detection and concerns for desaturation detection in high-inductance and high dc-bus voltage SC events.

42 ENGINEERING↗

Interpretation of hydrothermal conditions, production-injection induced effects, and evidence for enhanced geothermal system-type heat exchange in response to >30 years of production at Roosevelt Hot Springs, Utah, USA

The Roosevelt Hot Springs hydrothermal system is located at the base of the Mineral Mountains in southwestern Utah on the eastern side of the Basin and Range. Hydrothermal activity is related to relatively recent bimodal magmatism, and the system is hosted in coarsely crystalline rock made of Oligocene–Miocene granitoids and Precambrian gneiss. The hydrothermal plume covers ~5 km 2 , with a maximum temperature of 268 °C at ~750 m depth, and a vertically extensive fault-fracture mesh east of the Opal Mound fault controls the upflow of hydrothermal fluids. Power generation (currently 38 MWe gross) began in 1984, and up through 2016, four wells were used for fluid production, and three wells were used for edge-field injection. Chemical analyses of produced fluids show that modern reservoir fluid compositions are similar to but more concentrated than those at the start of production, having near-neutral pH, total dissolved solids of 7000–10,000 mg/kg, and ionic ratios of Cl/HCO 3 ~50–100, Cl/SO4 ~50–100, and Na/K ~4–5. Chemical geothermometers indicate equilibration temperatures that mainly range between 240° and 300 °C. Early production induced a steep drop in pressure (~3.0–3.5 MPa), which was accompanied by a 250–300 m lowering of piezometric levels in wells and development of a shallow steam zone across the system. Hydrothermal fluid compositions evolved continuously in response to production-related steam-loss and injection breakthrough, which is reflected by gradual increases in chloride of up to 35% and stable isotope ratios of up to ~2‰δ 18 O and ~10‰δD. Simple mixing model calculations suggest that there has been a significant amount, ~10–20 MW th , of sustained multi-decadal heat mining and enhanced geothermal system (EGS)–type heat transfer by the injectate as it returns to the production zone. Overall, the two factors that have sustained long-term power production (currently 38 MWe gross) are the increased upflow of deep chloride water and, to a lesser extent, the mining of heat at <1 km depth.

58 GEOSCIENCES↗

Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors

The protection, control, and monitoring of the power grid is not possible without accurate measurement devices. As the percentage of renewable energy sources penetrating the existing grid infrastructure increases, so do uncertainties surrounding their effects on the everyday operation of the power system. Many of these devices are sources of high-frequency transients. These transients may be useful for identifying certain events or behaviors otherwise not seen in traditional analysis techniques. Therefore, the ability of sensors to accurately capture these phenomena is paramount. In this work, two commercial-grade power system distribution sensors are investigated in terms of their ability to replicate high-frequency phenomena by studying their responses to three events: a current inrush, a microgrid “close-in”, and a fault on the terminals of a wind turbine. Kernel density estimation is used to derive the non-parametric probability density functions of these error distributions and their adequateness is quantified utilizing the commonly used root mean square error (RMSE) metric. It is demonstrated that both sensors exhibit characteristics in the high harmonic range that go against the assumption that measurement error is normally distributed.

47 OTHER INSTRUMENTATION↗

Photovoltaic module reliability improvement through application testing and failure analysis

During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

Dumas, L. N.↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study, volume 1

An active controls technology (ACT) system architecture was selected based on current technology system elements and optimal control theory was evaluated for use in analyzing and synthesizing ACT multiple control laws. The system selected employs three redundant computers to implement all of the ACT functions, four redundant smaller computers to implement the crucial pitch-augmented stability function, and a separate maintenance and display computer. The reliability objective of probability of crucial function failure of less than 1 x 10 to the -9th power per flight of 1 hr can be met with current technology system components, if the software is assumed fault free and coverage approaching 1.0 can be provided. The optimal control theory approach to ACT control law synthesis yielded comparable control law performance much more systematically and directly than the classical s-domain approach. The ACT control law performance, although somewhat degraded by the inclusion of representative nonlinearities, remained quite effective. Certain high-frequency gust-load alleviation functions may require increased surface rate capability.

Hanks, G. W.↗