Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

System and method for forming material substrate printer

A method is disclosed for manufacturing a part via an additive manufacturing process. A solution is used which has a volatile component within which is suspended particles of a powdered material. The solution is heated until it at least one of begins boiling or is about to begin boiling. The heated solution is then deposited at least at one location on a substrate to help form a layer of the part. The volatile component then evaporates, leaving only the particles of powdered material. The particles are then heated to the melting point. The deposition and heating operations are repeated to successively form a plurality of layers for the part. The evaporation of the volatile component helps to cool the part.

36 MATERIALS SCIENCE↗

Suggestions on the Vapor Pressure Determination of Molten Salts

The knowledge of the thermophysical properties of coolant and fuel in molten salts nuclear reactors (MSRs), such as thermal stability and vapor pressure, are of remarkable interest, particularly for simulating safe reactor operations. Molten salt reactorsMSRs use molten salt mixtures as the primary coolant and/or fuel and are expected to operate up to 800 °C. With the revival of interest in deploying MSRs, complete thermophysical and thermochemical characterization of these materials is of interest to industry, regulators, and researchers. Vapor pressure data for molten salts are scarce in the literature, both for pure salts but especially for eutectic mixtures. This report describes the effusion method, which consist of measuring the rate of escape of vapor molecules through a small orifice for the determination of the vapor pressure of compounds and may be useful on compounds such as molten salts. Thermogravimetric analysis records the mass loss as a function of time and temperature. There are two equations that can be used to relate the mass loss rate with the vapor pressure: (1) the Knudsen equation and (2) the Langmuir equation. To apply these equations, the system needs to reach a pseudo (or near) equilibrium condition. Therefore, the experimental conditions must be such that allow the condensed and the vapor/gas phases to be in equilibrium. In order to accomplish equilibrium like conditions, the sample must be in an almost-sealed cell except for a small orifice, from where the vapor escapes. In the Knudsen method vacuum is applied to eliminate the effect that the presence of other gas molecules could have on the evaporation rate of the sample. However, Langmuir alleged that in certain conditions, such as at low temperatures and/or when the vapor pressure is low, the rate of evaporation of a substance is independent of the presence of vapor around it. For that reason, some researchers, when measuring the mass loss of a substance with a predictable low vapor pressure, do not apply vacuum when using the Langmuir equation. However, they use a standard substance to parameterize the experimental setup. The use of one equation or the other will depend on the characteristics of the sample and the availability of an appropriate standard. Some important aspects related to the nature of the samples and vapor pressure measurements are described for future consideration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Systems and methods for photothermal material

Chinese ink is applied on various materials and stabilized by atomic layer deposition to fabricate solar steam generation devices. The encapsulated ink has excellent photothermal properties and evaporation efficiency under simulated sunlight, holding great promise in solar evaporation device applications.

Yang, Hao-Cheng↗

System and method for forming material substrate printer

A method is disclosed for manufacturing a part via an additive manufacturing process. A solution is used which has a volatile component within which is suspended particles of a powdered material. The solution is heated until it at least one of begins boiling or is about to begin boiling. The heated solution is then deposited at least at one location on a substrate to help form a layer of the part. The volatile component then evaporates, leaving only the particles of powdered material. The particles are then heated to the melting point. The deposition and heating operations are repeated to successively form a plurality of layers for the part. The evaporation of the volatile component helps to cool the part.

Demuth, James A.↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Experimental study of steam-driven ejector heat pump

Ejector-driven systems have been shown to be promising for heating applications. Most of the research works have been devoted to cooling purposes, while little attention has been focused on heating applications. An experimental steam ejector heat pump system (EHP) was designed and constructed to assess its applicability to water heating applications. The effect of the primary nozzle exit position (NXP) on the performance of the steam ejector system was investigated for primary nozzle throat diameter of 1.5 mm and 2.0 mm. The ejector system was run for high-temperature evaporator (HTE) temperatures of 120, 130, and 140 °C and low-temperature evaporator (LTE) temperatures of 10, 15, and 20 °C. The target of this investigation was to attain the highest condensing temperature to be able to use the proposed system for water heating purposes. The ejector heat pump coefficient of performance (EHP COP) was used to determine the system efficiency. Larger LTE temperatures were found to result in higher EHP COPs and condensing temperatures. A maximum EHP COP of 2.02 was attained for a HTE and LTE temperatures of 120 °C and 20 °C, respectively; however only resulted in a condensing temperature of 22.88 °C. Higher HTE temperatures were found to result in higher condensing temperatures but at the cost of EHP COP.

Spitzenberger, Jeremy↗

GaN vertical-channel junction field-effect transistors with regrown p-GaN by metal organic chemical vapor deposition (MOCVD)

Fabricating a vertical-channel junction field-effect transistor includes forming an unintentionally doped GaN layer on a bulk GaN layer by metalorganic chemical vapor deposition, forming a Cr/SiO 2 hard mask on the unintentionally doped GaN layer, patterning a fin by electron beam lithography, defining the Cr and SiO 2 hard masks by reactive ion etching, improving a regrowth surface with inductively coupled plasma etching, removing hard mask residuals, regrowing a p-GaN layer, selectively etching the p-GaN layer, forming gate electrodes by electron beam evaporation, and forming source and drain electrodes by electron beam evaporation. The resulting vertical-channel junction field-effect transistor includes a doped GaN layer, an unintentionally doped GaN layer on the doped GaN layer, and a p-GaN regrowth layer on the unintentionally doped GaN layer. Portions of the p-GaN regrowth layer are separated by a vertical channel of the unintentionally doped GaN layer.

Zhao, Yuji↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Multijunction organic photovoltaics incorporating solution and vacuum deposited active layers

There is disclosed an organic photovoltaic device comprising at least one first subcell comprising at least one first small molecular weight material deposited by solution processing, and at least one second subcell comprising a weight at least one second small molecular material deposited by vacuum evaporation. Also disclosed herein is a method for preparing an organic photovoltaic device comprising at least one first subcell comprising at least one first small molecular weight material and at least one second subcell comprising at least one second small molecular weight material, the method comprising depositing at least one first small weight material by solution processing; and depositing at least one second small weight material by vacuum evaporation.

Forrest, Stephen R.↗

Heat pipe with axial wick

A heat pipe has an evaporator portion, a condenser portion, and at least one flexible portion that is sealingly coupled between the evaporator portion and the condenser portion. The flexible portion has a flexible tube and a flexible separator plate held in place within the flexible tube so as to divide the flexible tube into a gas-phase passage and a liquid-phase artery. The separator plate and flexible tube are configured such that the flexible portion is flexible in a plane that is perpendicular to the separator plate.

Ambrose, Jay H.↗

Investigation of properties of CdSeTe/Sb and Sb/CdSeTe stacks

The effect of Sb inclusion in CdSeTe thin films was examined. CdSeTe alloys were grown by co-evaporation, either on 5 nm thick electron-beam evaporated Sb layers (Sb/CdSeTe) or coated with Sb post-deposition (CdSeTe/Sb). Sb inclusion improved CdSeTe grain structure, a critical factor for device performance, with average grain size increasing from 0.6 to 1.5 μm. All samples crystallized on annealing to the cubic structure, with a change in film orientation from (111) to random or (220). The presence of Sb in CdSeTe/Sb or Sb/CdSeTe samples, however, had a limited effect on the carrier concentration compared to Sb-free samples. Time resolved photoluminescence showed Sb inclusion increased decay lifetimes, with τ1 = 0.8 ns for and τ2 = 6.9 ns for the Sb/CdSeTe sample.

14 SOLAR ENERGY↗

Performance Evaluation of Various Configurations for Domestic Refrigerators with R600a

The increasing global focus on mitigating global warming has driven a change in refrigerant selection for domestic refrigerators. While most existing refrigerators use R-134a as their working fluid, there is a gradual shift towards R600a in newly manufactured products to minimize environmental impact. In order to design a more energy-efficient isobutane refrigerator, various configurations, including both single-evaporator and dual-evaporator cycles, were investigated. The study was conducted using a high-fidelity simulation platform, the Heat Pump Design Model (HPDM), developed and experimentally validated by the US DOE/ORNL. This platform includes detailed segment-to-segment heat exchanger model, fan model, and compressor model, utilizing refrigerant properties from REFPROP 10. A quasi-steady-state approach was employed to simulate the transient behavior and performance of a domestic refrigerator. The performance of various configurations was compared, and the effects of the refrigerant properties and operating conditions were also analyzed and discussed.

Yang, Cheng-Min↗

Aircraft electric motor having a stator heat pipe cooling scheme

Aircraft electric motors are described. The aircraft electric motors include a motor unit having a rotor and a stator, wherein the stator includes a plurality of windings and cooling channels arranged to provide cooling to the plurality of windings, a drive unit configured to drive operation of the motor unit, and a cooling system. The cooling system includes an oscillating heat pipe containing a first working fluid, wherein the oscillating heat pipe is arranged to pick up heat from at least one winding, the oscillating heat pipe having an evaporator section arranged in thermal contact with the at least one winding and a condenser section arranged away from the evaporator section and a heat pickup portion arranged to receive a second working fluid to remove heat from the condenser section of the oscillating heat pipe.

Saviers, Kimberly Rae↗

Heat exchanger(s) for recovering water and/or heat energy from turbine engine combustion products

A turbine engine is provided that includes a fan section, a turbine engine core and a recovery system. The turbine engine core is configured to power the fan section. The turbine engine core includes a core compressor section, a core combustor section and a core turbine section. A centerline axis of the turbine engine core is offset from a centerline axis of the turbine engine. The recovery system includes an evaporator module and a condenser module. A core flowpath extends sequentially through the core compressor section, the core combustor section, the core turbine section, the evaporator module and the condenser module from an inlet into the core flowpath to an exhaust from the core flowpath.

Sobanski, Jon E.↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Determining the Solubility Behavior of Kogarkoite in Simulated Nuclear Waste

Kogarkoite (Na 3 FSO 4 ) is a sparingly soluble fluoride–sulfate double salt that has been identified in high level nuclear waste sludge at the Hanford Site and, more recently, in sludge batch compilation samples at the Savannah River Site (SRS). Due to its complex dissolution behavior, which exhibits an inverse dependence on sodium ion activity, the presence of this mineral poses significant challenges to waste retrieval and processing. Incomplete dissolution during sludge washing can lead to the retention of fluoride and sulfate in the high-level waste feed, potentially causing the formation of corrosive, immiscible molten salt layers, known as "glass gall,” in vitrification melters. Current efforts to optimize flowsheet parameters and wash-water volumes are hindered by the absence of a commercially available, certified reference material, which prevents the accurate calibration of analytical methods and the verification of dissolution kinetics. To address this critical gap, this research focuses on the laboratory synthesis of pure Kogarkoite to serve as a standard for comprehensive solubility and washing performance testing. A coupled synthesis and simulant campaign was executed using an evaporative crystallization protocol designed to replicate the dynamic concentration effects observed in tank farm operations. Thirteen simulant matrices were prepared by dissolving systematically varied ratios of sodium fluoride (NaF) and sodium sulfate (Na 2 SO 4 ) in deionized water under three distinct caustic regimes: 0.0 g (control), 4.0 g (~1 M), and 12.0 g (~3 M) sodium hydroxide (NaOH). While thermodynamic equilibrium models suggest that high-caustic environments should favor the stability of the double salt7, results from this evaporative study at 25 0 C revealed a distinct kinetic divergence. Simulants with high hydroxide loading predominantly yielded large, blocky crystals of sodium sulfate decahydrate (Na 2 SO 4 .10H 2 O). Successful synthesis of pure Kogarkoite was achieved exclusively in specific NaOH-free compositional windows, where the precipitate manifested as fine, opaque granular aggregates. Ion chromatography (IC) analysis confirmed phase purity through the simultaneous stoichiometric depletion of both fluoride and sulfate from the supernatant. This successful synthesis establishes a reproducible route to generate bulk Kogarkoite, enabling the subsequent phase of quantitative dissolution testing using inhibited water to optimize sludge-batch assembly.

Sarker, Md Sharif [Florida International Univ. (FI↗