Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy systems security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Battery Energy Storage Systems Report

Battery energy storage systems (BESS) are a critical component of grid reliability and resilience today, providing rapid response capabilities while enabling grid modernization and capacity expansion across the United States. As utilities, communities, and customers prepare to deploy significant BESS capacity over the next several years, the United States has an opportunity to build security into battery system design and deployments. This report provides a framework for assessing the current dominance of foreign-manufactured components in the supply chains for BESS, inverter-based resources, and transformers. It offers high-impact, actionable solutions to service partners, industry, and government to address supply chain risks for currently installed, in design, and future deployments.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Material Identification From Radiographs Without Energy Resolution

We propose a method for performing material identification from radiographs without energy-resolved measurements. Material identification has a wide variety of applications, including in biomedical imaging, nondestructive testing, and security. While existing techniques for radiographic material identification make use of dual energy sources, energy-resolving detectors, or additional (e.g., neutron) measurements, such setups are not always practical— requiring additional hardware and complicating imaging. We tackle material identification without energy resolution, allowing standard X-ray systems to provide material identification information without requiring additional hardware. Assuming a setting where the geometry of each object in the scene is known and the materials come from a known set of possible materials, we pose the problem as a combinatorial optimization with a loss function that accounts for the presence of scatter and an unknown gain and propose a branch and bound algorithm to efficiently solve it. We present experiments on both synthetic data and real, experimental data with relevance to security applications— thick, dense objects imaged with MeV X-rays. We show that material identification can be efficient and accurate, for example, in a scene with three shells (two copper, one aluminum), our algorithm ran in six minutes on a consumer-level laptop and identified the correct materials as being among the top 10 best matches out of 8,000 possibilities.

36 MATERIALS SCIENCE↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

Prioritizing ICS Beachhead Systems for Cyber Vulnerability Testing

Cyber Testing for Resilient Industrial Control Systems™ (CyTRICS™) is the Department of Energy’s (DOE’s) program for cybersecurity vulnerability testing, digital subcomponent enumeration, and forensic assessment. CyTRICS leverages best-in-class test facilities and analytic capabilities at six DOE National Laboratories and strategic partnerships with key stakeholders including technology developers, manufacturers, asset owners and operators, and interagency partners. During the program’s development, CyTRICS established a unique methodology for prioritizing digital components within operational technology (OT) and industrial control systems (ICS) in the Energy Sector Industrial Base (ESIB) for cyber vulnerability testing. The CyTRICS Prioritization Process leverages multiple characteristics of systems, components, and their contextual deployment to calculate a quantification of individual digital components for CyTRICS testing. The initial version of the CyTRICS Prioritization Process was premised largely upon the impact which could result to an industrial control system if the digital component under testing was compromised, either through malicious means, faulty engineering, or other modes. The worldwide compromise of the SolarWinds Orion platform, first reported in December 2020, through malicious interference with the digital patching cycle was a watershed event in cyber supply chain security. The SolarWinds compromised demonstrated the strategic importance of certain types of ubiquitous software, and the ability to generate widespread cybersecurity effects. To address this challenge and as a part of the Department of Energy’s response to the SolarWinds compromise, DOE’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER) directed the National Laboratories to evolve the CyTRICS Prioritization Process methodology to encompass additional factors related to the strategic importance of digital components. CESER directed CyTRICS researchers to identify, characterize, and append strategic factors to the CyTRICS Prioritization Process to provide additional weight to these characteristics. National Laboratory expert researchers identified functionality, distribution, and platform characteristics for digital components in ICS and OT that they assessed would be likely targeted in strategic initial-access cyber attack. CyTRICS has termed these factors “ICS Beachhead Systems,” leveraging a definition first advanced by Schneider Electric, which is intended as a blanket term to encompass digital components, products, and systems in OT. This paper describes the ICS Beachhead Systems identified and the rationale for inclusion. As a next step in the research and refinement process, the National Laboratories will validate this initial set of characteristics against digital components evaluated by the CyTRICS program and current implementation of the CyTRICS Prioritization Process. After validation, CyTRICS researchers will then develop a scoring methodology to generate a quantitative score to assess the degree to which a digital component is characterized as an ICS Beachhead System. Finally, the National Laboratories will append this scoring to the existing CyTRICS Prioritization Process algorithm.

97 MATHEMATICS AND COMPUTING↗

Blockchain Research and Development Activities Sponsored by the U.S. Department of Energy and Utility Sector

This article provides an in-depth analysis of blockchain research in the energy sector, focusing on projects funded by the U.S. Department of Energy (DOE) and comparing them with industry-funded initiatives. A total of 110 funded activities within the U.S. power industry were successfully tracked and mapped into a newly developed categorization framework. This framework is designed to help research agencies to systematically understand their funded portfolio. Such characterization is expected to help them make effective investments, identify research gaps, measure impact, and advance technological progress to meet national goals. In line with this need, the proposed framework proposes a 2-D categorization matrix to systematically classify blockchain efforts within the energy sector.Under the proposed framework, the Energy System Domain serves as the primary classification dimension, categorizing use cases into 30 distinct applications. The second dimension, Blockchain Properties, captures the specific needs and functionalities provided by Blockchain technology. The aim was to capture blockchain’s applicability and functionality: where and why blockchain? Principles behind the selection of the viewpoint dimensions were carefully defined based on consensus obtained through the Blockchain for Optimized Security and Energy Management (BLOSEM) project. The mapped results show that activities within the Grid Automation, Coordination, and Control (31.8%), Marketplaces and Trading (25.5%), Foundational Blockchain Research (19.1%), and Supply Chain Management (17.3%) domains have been actively pursued to date. The three leading specific use case applications were identified as Transactive Energy Management for Marketplaces and Trading, Asset Management for Supply Chain Management, and Fundamental Blockchain for Foundational Blockchain Research. The Marketplaces and Trading and Retail Services Enablement domains stood out as being favored by industry by a factor greater than 2 (2.3 and 2.6, respectively), yet there seemed to be little to zero investment from DOE. Approximately 76% of the total projects prioritized Immutability, Identity Management, and Decentralization and/or Disintermediation compared to Asset Digitization and/or Tokenization, Automation, and Privacy and/or Anonymity. The greatest discrepancies between DOE and industry were in Asset Digitization and/or Tokenization and Automation. The industry efforts (36% in Asset Digitization/Tokenization and 22% in Automation) was 14 times and 2.4 times, respectively, more intensive than the DOE-sponsored efforts, indicating a significant discrepancy in industry versus government priorities. Overall, quantifying DOE-sponsored projects and industry activities through mapping provides clarity on portfolio investments and opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - Asimily Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator (TM) (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The shape of electrified transportation

Transportation is currently the least-diversified energy demand sector, with over 90% of global transportation energy use coming from petroleum products [1]. For more than a century, petroleum fuels have been relied upon to move people and goods within and between towns and cities, and on roads, railways, farms, waterways, and in the air. These energy-dense fuels have unquestionably provided reliable and convenient mobility options to power the modern global economy. However, these benefits have also created challenges associated with geopolitics, energy security, price volatility, and environmental impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statement of Work. Y-12 National Security Complex Security Infrastructure Revitalization Program Project - Combination Inspector

The Y-12 SIRP Quadrant 1, Quadrant 2, and Vehicle Barrier project involves the following summary elements. The perimeter intrusion detection and assessment system (PIDAS) is an existing system at the Y-12 National Security Complex, which is a government-owned facility located in Oak Ridge, Tennessee, and managed by Consolidated Nuclear Security, LLC (CNS) for the Department of Energy (DOE). National Technology and Engineering Solutions of Sandia, LLC (NTESS) is the engineering design agent and construction manager (CM) for the Y-12 SIRP effort. The Quadrants 1 and 2 portion of the project involves the replacement of the PIDAS, and the vehicle barrier portion of the project involves the installation of a continuous passive vehicle barrier alongside the inner PIDAS fence.

42 ENGINEERING↗

Modulated High-Energy Gamma-Ray Emission from the Microquasar Cygnus X-3

Microquasars are accreting black holes or neutron stars in binary systems with associated relativistic jets. Despite their frequent outburst activity, they have never been unambiguously detected emitting high-energy gamma rays. The Fermi Large Area Telescope (LAT) has detected a variable high-energy source coinciding with the position of the x-ray binary and microquasar Cygnus X-3. Its identification with Cygnus X-3 is secured by the detection of its orbital period in gamma rays, as well as the correlation of the LAT flux with radio emission from the relativistic jets of Cygnus X-3. The gamma-ray emission probably originates from within the binary system, opening new areas in which to study the formation of relativistic jets.

Celik, O.↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous-time look-ahead flexible ramp scheduling in real-time operation

This paper develops a novel continuous-time look-ahead optimization model for co-optimizing balancing energy and flexible ramp products in real-time power systems operation. In addition, a continuous-time day-ahead operation model is developed to commit and schedule an adequate subset of generating units for providing balancing energy and ramping requirements in real-time operation. The up and down flexible ramp products are defined as continuous-time decision trajectories that continuously supply the real-time up and down ramping requirements of the system. The deliverability of flexible ramp products is secured through reserving the respective power requirements in generation capacity constraints of generating units. A function space solution method is proposed to reduce the dimensionality of day-ahead and real-time models through projecting them into finite-dimensional function spaces spanned by Bernstein polynomials, where the real-time operation decisions are modeled with a higher accuracy level than day-ahead decisions. Simulations are conducted on the IEEE-RTS system using CAISO load data, and the numerical results showcase the effectiveness of the proposed model in supplying the energy and flexible ramp requirements and avoiding ramping scarcity in the system, while reducing the operation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BESS Digital Assurance, Supply Chain Risk Management, and Emerging Regulation Session Two

The TADA BESS Supply Chain Workshops are designed to equip participants with the knowledge and tools necessary to address the evolving challenges at the intersection of battery energy storage systems (BESS), cybersecurity, and supply chain vulnerabilities. The workshops emphasize the application of Cyber-Informed Engineering (CIE) principles using INL’s procurement guide and the CIE-BAT tool. Attendees will develop risk-based security strategies and actionable compliance roadmaps tailored to their BESS projects. Additionally, the program fosters a collaborative network of practitioners and provides guidance on navigating emerging regulatory requirements, including FEOC rules under the OBBB framework, to assess and enhance organizational readiness. A comprehensive exploration of BESS cybersecurity supply chain risks, systematic vendor risk assessment through the BESS Procurement Guide, and practical application of the INL SCRM Chatbot for enhanced supply chain resilience. This is Session 2 of 3. (Full Version)

25 - ENERGY STORAGE↗

Energy Storage Impacts in Resilience Hubs and Other Critical Infrastructure: An Assessment Guide for Developers and Practitioners

Battery energy storage systems (BESS) deployed behind the meter at resilience hubs and other critical infrastructure can provide economic and operational value during normal operations—such as lower and more predictable energy costs—as well as resilience and security benefits during power disruptions by maintaining essential services. However, existing evaluation approaches tend to focus narrowly on engineering performance or rely on broad socio-economic frameworks that are not well suited to behind-the-meter storage. As a result, developers, utilities, and funders often lack consistent methods for defining success, quantifying benefits, and comparing outcomes across projects. This report presents a practitioner-oriented impact assessment framework for evaluating behind-the-meter BESS at resilience hubs and critical infrastructure facilities. The framework is organized into five iterative components—developing an action plan, defining project goals, identifying metrics, collecting data and measuring outcomes, and reporting and using results—and includes a structured metric architecture spanning six impact categories. Designed for real-world constraints such as limited staffing and uneven data availability, the framework was developed, applied, and refined through real projects, and is illustrated with case studies across diverse deployment contexts.

Impact Assessment↗

Mental Models for Managing Grid Cybersecurity Risk - ARC Industry Forum, Cybersecurity and Energy Transition

A proper mental model of the concepts of cyber risk and its components of threat and exploitability and consequence is necessary to allocate limited resources to different security activities, especially when considered alongside reliability and regulatory and economic risks. Understanding the consequence and frequency different risks are realized also helps align the right mitigations to the right risks. Cyber-informed engineering (CIE) is an emerging method to “engineer out” cyber risk across product and system lifecycles, and INL has a portfolio of programs operationalizing CIE’s principles for the energy sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗