Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Doping of Cr in Graphene Using Electron Beam Manipulation for Functional Defect Engineering

Chromium atoms in graphene have been proposed to exhibit magnetic moments and spin-selective conducting states depending on the local bonding geometry within the graphene structure, which could lead to interesting applications in spintronics. Despite this interest, there are few direct experimental reports of Cr dopants in graphene even though it is theorized to be stable. Here, we demonstrate the introduction of single Cr dopant atoms into the graphene lattice and onto graphene edges through the controlled use of a focused electron beam in a scanning transmission electron microscope. Here, we show local control of doping locations, and when coupled with targeted in situ milling during scanning of the e-beam, these strategies demonstrate an important component of the fabrication of tailored nanostructured devices in the electron microscope. The approach is validated with first-principles calculations to understand synthesis pathways during fabrication and reveal the energetics and local properties of Cr atoms embedded in graphene; for example, Cr doping can convert graphene into a magnetic and semiconducting material, which suggests Cr-doped graphene can be used as a building block for potential electronic devices and a means to construct them.

36 MATERIALS SCIENCE↗

Dynamic properties of 316l stainless steel repaired using electron beam additive manufacturing

Additive manufacturing has the potential to be used for repair of high-value parts, but the strength and integrity of such repaired parts, especially under dynamic loading, in still unknown. This work presents the results of high strain-rate dynamic testing of additively repaired stainless steel samples. The 316L samples were intentionally damaged and subsequently repaired with 308L stainless steel wire using electron beam additive manufacturing. The repaired samples were subjected to gas-gun impact testing to induce incipient damage and determine the role played by the repaired region in dictating damage and failure. The results show the following: 1) the equation of state of the repaired region is comparable to the original material as shown by the unchanged spall plane location, 2) the deformation behavior is similar to the original material as shown by the similar Hugoniot Elastic limit, 3) the spall strength of the repaired region is slightly higher than the original material due to varying grain size, and 4) the damage morphology in the repaired region is different and involves a high rate of void coalescence. In conclusion, despite these minor differences in the spall strength and the damage morphology, the overall dynamic response of the original material and repaired samples is similar suggesting that AM is a promising approach for repairing high-value components.

36 MATERIALS SCIENCE↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

Adjusting an electron beam for drilling

Reticle contains two concentric circles: inner circle insures beam circularity and outer circle is guide to prevent beam from cutting workpiece clamp. Precise measurement of beam and clamp are required with old reticle. New reticle speeds up electron-beam drilling process by eliminating need to rotate eyepiece to make measurements against reticle scale.

Childress, C. L.↗

Electron beam irradiation effects on bulk metals: a comparative study of polycrystalline versus single-crystalline structures

This study investigates the effects of electron beam (e-beam) irradiation on the mechanical and structural properties of eight bulk metallic samples, comprising both polycrystalline (PC) and single-crystalline (SC) forms of Ni, Cr, V, and Ti. These metals were evaluated as potential candidates for beam exit windows in high-power (MW-class) particle accelerators. The primary objective is to identify metals capable of withstanding the conditions of high-power/MW-class e-beam accelerators and serve effectively as exit windows. Selection criteria were based on each metal’s intrinsic properties, power dissipation capability, and irradiation-induced changes in mechanical behavior, including hardness, elastic modulus, and defect density. Comprehensive characterization was conducted using field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM–EDS), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and nanoindentation, performed both before and after exposure to a ~¿66 kGy dose from a 10 MeV e-beam accelerator. Results revealed that e-beam irradiation induced hardening in PC Ni, whereas PC Ti, commonly used in beam exit windows, exhibited softening. The observed softening in PC Ti is attributed to grain coarsening, elongation, and the formation of twins and twin boundaries, in contrast to the smaller, compressed grains in the pristine (Pr) PC Ti samples, consistent with the Hall–Petch relationship. The stresses due to twinning are small and insignificant in influencing the overall hardening of the PC Ti irradiated sample when compared to the stresses due to the dislocation density. Conversely, SC Ti samples exhibited irradiation-induced hardening. The SC Ti irradiated samples developed additional irradiation-induced modifications in crystallographic texture of (100), (101), (110), (200), (112), (004), and (211) as evidenced from the XRD results, which could probably explain the hardening effect that is caused by irradiation.

36 MATERIALS SCIENCE↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Stitching-error reduction in gratings by shot-shifted electron-beam lithography

Calculations of the grating spatial-frequency spectrum and the filtering properties of multiple-pass electron-beam writing demonstrate a tradeoff between stitching-error suppression and minimum pitch separation. High-resolution measurements of optical-diffraction patterns show a 25-dB reduction in stitching-error side modes.

Integrated optics semiconductor lasersgratings↗

Closed-loop electron-beam-induced spectroscopy and nanofabrication around individual quantum emitters

Color centers in diamond play a central role in the development of quantum photonic technologies, and their importance is only expected to grow in the near future. For many quantum applications, high collection efficiency from individual emitters is required, but the refractive index mismatch between diamond and air limits the optimal collection efficiency with conventional diamond device geometries. While different out-coupling methods with near-unity efficiency exist, many have yet to be realized due to current limitations in nanofabrication methods, especially for mechanically hard materials like diamond. Here, we leverage electron-beam-induced etching to modify Sn-implanted diamond quantum microchiplets containing integrated waveguides with a width and thickness of 280 nm and 200 nm, respectively. This approach allows for simultaneous high-resolution imaging and modification of the host matrix with an open geometry and direct writing. When coupled with the cathodoluminescence signal generated from the electron–emitter interactions, we can monitor the enhancement of the quantum emitters in real-time with nanoscale spatial resolution. The operando cathodoluminescence measurement and fabrication around single photon emitters demonstrated here provide a new foundation for the potential control of emitter–cavity interactions in integrated quantum photonics.

36 MATERIALS SCIENCE↗

Microstructure and high temperature properties of tungsten processed via electron beam melting additive manufacturing

There is considerable interest in the adoption of additive manufacturing for processing refractory metals. The layer-wise fabrication approach enables opportunities for producing complex geometries which cannot be otherwise be achieved via powder metallurgy. However, the processing science is still in its nascent stages and structure–property relations are relatively unexplored. Fundamental research is needed to further develop the technology and enable the fabrication of refractory metals for high temperature applications. Here we focus on the processing of pure tungsten using electron beam melting additive manufacturing. Experimentally we develop a suitable processing window for achieving high density crack free material. Microstructural analysis reveals that the microstructure generally consists of a columnar structure with a (111) build direction fiber preference, although, fiber switching was observed. Process induced deformation is believed to drive the formation of subgrains whose boundaries exhibit a high dislocation density. Additionally, high temperature tensile testing reveals that the material exhibits excellent properties closer to that of annealed tungsten. Significant mechanical anisotropy was observed to be present which is likely driven by strong crystallographic texture.

36 MATERIALS SCIENCE↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electric potential structures and propagation of electron beams injected from a spacecraft into a plasma

One-dimensional Vlasov simulations are used to study the propagation of electron beams injected from a spacecraft into an ambient plasma and the associated potential structures. It is shown that, for a given beam velocity, the propagation velocity and the potential structure depends on the beam density. In the case of moderate beams, a double layer forms near the beam head which propagates into the ambient plasma much more slowly than the initial beam velocity.

Singh, Nagendra↗

Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

Winckler, J. R.↗

Effect of Electron Beam Irradiation on the Tensile Properties of Carbon Nanotubes Sheets and Yarns

Carbon nanotube sheets and yarns were irradiated using electron beam (e-beam) energy to determine the effect of irradiation dose on the tensile properties. Results showed that a slight change in tensile strength occurred after irradiating as-received CNT sheets for 20 minutes, and a slight decrease in tensile strength as the irradiation time approached 90 minutes. On the other hand, the addition of small molecules to the CNT sheet surface had a greater effect on the tensile properties of e-beam irradiated CNT sheets. Some functionalized CNT sheets displayed up to a 57% increase in tensile strength following 90 minutes of e-beam exposure. In addition, as-received CNT yarns showed a significant increase in tensile strength as the irradiation time increased.

Williams, Tiffany S.↗

Nickel-based superalloy single crystals fabricated via electron beam melting

Additive manufacturing technologies have emerged as potential disruptive processes whose possible impacts range from supply chain logistics, prototyping, and novel materials synthesis. Numerous works illustrate the ability to control mi- crostructure in fusion based processes and a few recent authors have even produced single crystals. However, a number of open questions remain regarding the process window which enables printing of single crystals. Furthermore, it has been observed that these additively manufactured single crystals exhibit a preferred $\langle$011$\rangle$ secondary orientation. In this work we investigate fabrication conditions which enable printing of single crystals via electron beam melting. A space filling design of experiments is utilized to efficiently explore the fabrication space. Single crystals were success- fully obtained using both commercially available powders and custom melt alloys. Microstructures obtained via these exploratory experiments exhibited a continuum of columnar structures ranging from weakly textured polycrystals, near single crystal, and fully single crystalline material. Complex geometry experiments are performed to study the grain selection mechanism. We find that the grain selection mechanism is independent of the bulk scale geometry and must therefore by driven by local heat transfer and solidification dynamics. Furthermore, grain selection is shown to be driven by competing driving forces; one which prefers epitaxial growth and another which is driven by the imposed scan pattern geometry. Finally, a mechanism is proposed for the anomalous secondary orientation preference.

36 MATERIALS SCIENCE↗

Energy Evaluation of Electron Beam Treatment of Perfluoroalkyl Substances in Water: A Critical Review

Due to their recalcitrant nature and ubiquitous use, per- and polyfluoroalkyl substances (PFAS) will continue to be major water treatment hurdles. Although effective water treatment technologies exist for physical removal of many PFAS from water (e.g., activated carbon and ion-exchange resin), a PFAS-concentrated waste stream is generated as an end product that can potentially reintroduce PFAS back into the environment. Thus, there is an increased interest in developing destructive technologies to decompose and mineralize PFAS directly in water or in these waste streams. High energy electron beam (e-beam) accelerators have been used for water treatment to degrade a wide range of recalcitrant contaminants, including PFAS, since the 1960s. However, large-scale applications of e-beam for water treatment are restricted due to its high energy consumption and inability to treat large flow rates. Considering there are very few available technologies for destructive removal of PFAS, this study provides a critical review on the treatment of PFAS by direct irradiation of contaminated water by e-beam from an energy consumption point of view. To date, very limited studies have been conducted to investigate the success of this technology to treat PFAS. Results from the limited studies were not directly comparable due to the variation in operating conditions and water quality parameters used in the studies. Here, for the first time, we develop and apply the concept of electrical energy per order (EE/O) to assess the performance of e-beam for PFAS treatment. Results show that EE/O is a better performance parameter than the G value of e-beam for interstudy comparisons and to evaluate the effects of water quality and operating parameters on e-beam performance. We additionally developed a kinetic scheme to predict the performance of e-beam to treat PFAS and revealed that the competition between species to react with aqueous electrons is the determinant factor influencing PFAS degradation efficiency. Comparison of EE/O values of e-beam (range: 31–176 kWh m –3 order –1 ) with other destructive technologies (range: 5–9595 kWh m –3 order –1 ) suggest that e-beam, for PFAS treatment, is a promising approach under favorable conditions. Furthermore, this review further elucidates the feasibility and limitations of e-beam technology that could be improved upon to potentially make e-beam viable for large-scale water treatment applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoemission characterization of N-polar III-nitride photocathodes as candidate bright electron beam sources for accelerator applications

We report on the growth and characterization of a new class of photocathode structures for use as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-nitride materials and are designed to leverage the strong polarization field, which is characteristic of this class of materials when grown in their wurtzite crystal structure, to produce a negative electron affinity condition without the use of Cs, possibly allowing these materials to be operated in radio frequency guns. A Quantum Efficiency (QE) of about 1×10−3 and an emitted electrons’ Mean Transverse Energy (MTE) of about 100 meV are measured at a wavelength of 265 nm. In a vacuum level of 3×10−10 Torr, the QE does not decrease after more than 24 h of continuous operation. The lowest MTE of about 50 meV is measured at 300 nm along with a QE of 1.5×10−5. Surface characterizations reveal a possible contribution to the MTE from surface morphology, calling for more detailed studies.

Cultrera, L. (ORCID:0000000235606059)↗