Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A study of the performance of an ion shutter for drift tubes in atmospheric pressure ion mobility spectrometry: Computer models and experimental findings

Ion mobility spectra are initiated when ions, derived from a sample, are pulsed or injected through ion shutters into a drift region. The effect on signal intensity from electric fields arising from the shutter grids (E{sub s}) and a superimposed electric field of the drift tube (E{sub d}) was determined experimentally and simulated computationally for ion motion at ambient pressure. The combination of these two fields influenced shutter performance in three ways: (1) intensity of an ion peak was suppressed by increased current in the baseline due to continuous leakage of ions into the drift region from insufficient E{sub s} to block ion motion when needed, at a given value of E{sub d}; (2) the ion shutter provided maximum peak intensity with some optimal ratio of E{sub s}/E{sub d} when ions were fully blocked except using the injection time; (c) the signal intensity was reduced when the blocking voltage of the ion shutter exceeded this optimal E{sub s}/E{sub d} ratio from ion depletion at the shutter grids. The optimal ratio from the computer models was equal to 1.50, whereas a value of 2.50 was obtained from the experimental findings. This difference was attributed to nonideal geometry with the grids of the shutter and the conducting elements in the drift tube establishing both E{sub s} and E{sub d}. As both the experimental and modeling results demonstrated, a mobility dependence of ion yield from the ionization source was found to cause a mobility dependent ion signal at the collector electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanosecond Repetitively Pulsed (NRP) Plasmas: Relationship Between Induced Flow and Plasma Characteristics at Atmospheric Pressure (Final Technical Report)

The local flow fields induced by plasma discharges at atmospheric pressure can play a critical role in aerodynamic flow and combustion control and have significant implications for plasma-based technologies in medicine and environmental engineering. However, the coupling between the plasma characteristics, the geometry and the induced flow field is not well understood. The primary goal of this work is to determine the relationship between the plasma characteristics and the induced flow field for nanosecond pulsed discharges at atmospheric pressure. A comprehensive experimental investigation of plasmas produced by nanosecond high-voltage pulses in a pin-to-pin electrode configuration was conducted, employing several measurement techniques including microwave and laser Rayleigh scattering, optical emission spectroscopy, and high-speed imaging. The flow field induced by the nanosecond plasma was measured and characterized using measurements of the velocity (particle image velocimetry) and density (background oriented schlieren) with unprecedented spatiotemporal resolution. The experimental measurements were complemented by development of a one-dimensional model of the plasma discharge and a high-fidelity computational fluid dynamics (CFD) simulation of the subsequent plasma-induced flow field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous detection of electronic structure changes from two elements of a bifunctional catalyst using wavelength-dispersive X-ray emission spectroscopy and in situ electrochemistry.

Multielectron catalytic reactions, such as water oxidation, nitrogen reduction, or hydrogen production in enzymes and inorganic catalysts often involve multimetallic clusters. In these systems, the reaction takes place between metals or metals and ligands to facilitate charge transfer, bond formation/breaking, substrate binding, and release of products. In this study, we present a method to detect X-ray emission signals from multiple elements simultaneously, which allows for the study of charge transfer and the sequential chemistry occurring between elements. Kβ X-ray emission spectroscopy (XES) probes charge and spin states of metals as well as their ligand environment. A wavelength-dispersive spectrometer based on the von Hamos geometry was used to disperse Kβ signals of multiple elements onto a position detector, enabling an XES spectrum to be measured in a single-shot mode. This overcomes the scanning needs of the scanning spectrometers, providing data free from temporal and normalization errors and therefore ideal to follow sequential chemistry at multiple sites. We have applied this method to study MnOx-based bifunctional electrocatalysts for the oxygen evolution reaction (OER) and the oxygen reduction reaction (ORR). In particular, we investigated the effects of adding a secondary element, Ni, to form MnNiOx and its impact on the chemical states and catalytic activity, by tracking the redox characteristics of each element upon sweeping the electrode potential. The detection scheme we describe here is general and can be applied to time-resolved studies of materials consisting of multiple elements, to follow the dynamics of catalytic and electron transfer reactions.

Gul, Sheraz↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

Probing Activities of Individual Catalytic Nanoflakes by Tunneling Mode of Scanning Electrochemical Microscopy

The tunneling mode of scanning electrochemical microscopy (SECM) was developed recently and applied to studies of charge-transfer reactions at single metal nanoparticles (NPs). When an SECM tip is brought within the tunneling distance from a conductive NP, the particle begins to act as a part of the nanoelectrode. Herein, we demonstrate the possibility of using carbon nanoelectrodes with a very thin insulating sheath for electrochemical tunneling experiments at flat samples. In this way, electrocatalytic activity, conductivity, and charging properties of and faradaic processes in layered nanomaterials can be characterized by single-nanoflake voltammetry without making direct ohmic contact with them. A broad applicability of tunneling SECM experiments is demonstrated by probing nanomaterials with different size, geometry, and electrocatalytic properties, including metallic/pseudo-metallic (1T/1T') and semiconducting (2H) MoS 2 nanoflakes, N-doped porous carbon catalyst, and MXene nanosheets. Further, the Tafel plots for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) at individual nanoflakes are compared to analogous measurements for an ensemble of flakes attached to the surface of a macroscopic electrode. Moreover, we observed variations in catalytic activities of individual MXene flakes toward HER and OER caused by non-uniform doping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional kinetic modeling of streamer propagation in a nitrogen/helium gas mixture

A fully resolved kinetic model (Particle-in-Cell and Direct Simulation Monte Carlo for particle/photon collisions) of a near atmospheric pressure ionization wave is presented here. Fully resolving the required numerical spatial (sub-um) and temporal scales (tens of fs) for atmospheric pressure discharges in three dimensions is still a challenging task on modern super computers. To keep the overall problem tractable, the total number of elements are reduced by only simulating a 10 degree wedge rather than a full 360 degree geometry. The ionization wave is generated in a needle-plane configuration with a gap size of 250 um and a background of nitrogen and helium gas. A voltage of 1500 V is applied to the anode and an initial electron and ion density of 10 9 cm 3 is seeded in a region near the anode electrode tip and extending towards the cathode. As these initial electrons are swept away, photoionization and photoemission create new electrons and allow the ionization front to propagate towards the cathode. Results from the 90% N 2 , 10% He discharge indicate that photoionization has minimal impact on plasma formation processes and cathode photoemission is the dominant mechanism for new electrons. In the 90% He, 10% N 2 discharge case, however, photoionization likely has an impact as the observed locations of photoionization occur far enough away from the ionization front to allow for sufficient avalanche processes that contribute to the propagation of the ionization wave. Additionally, the electron energy distribution functions in the 90% He, 10% N 2 case indicate that there is less energy loss to the low lying molecular N 2 electronic states as well as the vibrational and rotational modes. This leads to higher electron energies and faster plasma development times of ~0.4 ns for the 90% He, 10% N 2 case, and ~1.5 ns for the 90% N 2 , 10% He case. In addition to analysis of the ionization wave results, the overall challenges associated with simulations near atmospheric pressure discharges in three dimensions are discussed, including the limitations of the 10 degree wedge that produces, at least qualitatively, minimal 3D effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating Battery Simulations by Using High Performance Computing and Opportunities with Machine Learning

The US Department of Energy (DOE) estimates that the battery pack cost of $60 per kilowatt-hour while increasing the driving range to over 300 miles and vehicle charging under 15 min or less would enable mass penetration of electric vehicles in the USA by 2030. These projections are based on the currently available high-density cell chemistry combined with a system level design and optimized electrodes. Electrodes for current state-of-the-art lithium-ion cell technology are fabricated from electrode slurry comprising of active material, polymeric binder, and conductive diluent such as carbon black that are coated on metal current collectors such as copper and aluminum. Given these challenging requirements for development of electrical energy storage devices for future transportation needs, a predictive simulation capability which can accelerate design by considering performance and safety implications of different geometry, materials, and chemistry choices is required. In this chapter, we discuss our state-of-the-art three-dimensional modeling framework, providing examples on battery performance and safety simulations. We also present approaches to use machine learning in the context of large datasets that are becoming available.

Allu, Srikanth↗

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling of Armchair and Zigzag Tubes to a Free Electron Metal

The effect of nanotube chirality is of prime importance in determining its electronic properties. We address the issue of how chirality affects the coupling of a nanotube to metal contacts. We model coupling of armchair and zigzag nanotubes to metal contacts, in both the side- and end-contacted geometries. In the side-contacted geometry, the coupling of armchair and metallic-zigzag nanotubes to a free electron metal are significantly different. Namely, it is possible to drive a larger current through a metallic-zigzag nanotube. The predicted difference holds good when both (a) the entire circumference and (b) only a finite sector of the nanotube makes contact to the metal electrode. It might be possible to observe the predicted difference between armchair and zigzag nanotubes using gold contacts.

Anantram, M. P.↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscale 2.5D Batteries

3D solid-state batteries use vertical topography to increase both energy and power density relative to batteries with planar geometry. Here we investigate, using finite element simulations, a battery that incorporates a 3D cathode consisting of a vertical array of microcolumns, and a planar 2D anode, which we call a 2.5D battery. By confining the 3D structure to the cathode we greatly simplify the battery fabrication process (i.e., 3D structure only needs to be introduced into one electrode) at the cost of introducing a non-uniform electrolyte thickness in which the anode-cathode distance varies significantly across different parts of the battery. We use simulations to show that a non-uniform electrolyte thickness results in inhomogeneous lithiation and subsequent underutilization of the cathode. The underutilization of the cathode can be avoided by using an electrolyte with sufficient ionic conductivity, which suggests that non-uniform electrolyte thickness can be tolerated in high ionic conductivity electrolytes but should be avoided in low ionic conductivity electrolytes.

25 ENERGY STORAGE↗

A Stable Coordination Complex of Rh(IV) in an N,O-Donor Environment

Herein we describe facial and meridional isomers of [Rh III (pyalk) 3 ], as well as meridional [Rh IV (pyalk) 3 ] + {pyalk =2-(2-pyridyl)-2-propanoate}, the first coordination complex in an N,O-donor environment to show a clean, reversible Rh III/IV redox couple and to have a stable Rh(IV) form, which we characterize by EPR and UV–visible spectroscopy as well as X-ray crystallography. The unprecedented stability of the Rh(IV) species is ascribed to the exceptional donor strength of the ligands, their oxidation resistance, and the meridional coordination geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-cusp ion source for doping process of flat panel display manufacturing

We developed a multi-cusp ion source for Nissin ion doping system iG5 which is used in low temperature poly-crystalline silicon processes for flat panel display (FPD) manufacturing. In this ion source, BF{sub 3} or PH{sub 3} diluted H{sub 2} plasmas are produced and large area ribbon ion beams are extracted. In general, ion ratio of B{sup +} in BF{sub 3} plasma is much smaller than BF{sub 2}{sup +} in multi-cusp ion sources. We developed a new method to increase B{sup +} ratio and obtained mass analyzed B{sup +} target current of 130 mA. We employed newly improved multi-slot type electrodes for the beam extraction system and obtained stable beams with the uniformity of below 3%. In BF{sub 3} plasmas, several undesirable metal fluorides are produced in the plasma chamber and deposited on the electrode system, which cause glitches and poor beam uniformity. We introduce several cleaning methods.

36 MATERIALS SCIENCE↗

Electrochemical Synthesis of Zeolite Coatings with Controlled Crystal Polymorphism and Self-Regulating Growth

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days). Here, we report the first zeolite coatings synthesized via electrochemical deposition on a cathodic electrode, with controlled crystal polymorphism achieved within subhourly duration. We demonstrate this approach by developing sodium zeolite (e.g., sodalite (SOD), NaA (LTA), and Linde Type N (LTN)) coatings on a titanium electrode and extending the synthesis method to porous stainless steel. The coating morphology and crystallinity depend on the temperature, time, and applied current. The coating thickness is independent of the applied current, showing the presence of a self-regulating mechanism to ensure a uniform coating thickness across the metal surface. The electrochemical zeolite growth mechanism was elucidated with high-resolution transmission electron microscopy, and applications of the resultant zeolite coatings for oil/water separation and ethanol/water pervaporation were exploited. Electrochemical synthesis represents a novel, simple, fast, and environmentally friendly approach to preparing zeolite coatings. It can potentially be generalized for developing zeolite materials with diverse framework structures, morphologies, and orientations for substrates with complicated geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Morphological and Electrochemical Characterization of Nanostructured Li 4 Ti 5 O 12 Electrodes Using Multiple Imaging Mode Synchrotron X-ray Computed Tomography

In this study, synchrotron X-ray computed tomography has been utilized using two different imaging modes, absorption and Zernike phase contrast, to reconstruct the real three-dimensional (3D) morphology of nanostructured Li 4 Ti 5 O 12 (LTO) electrodes. The morphology of the high atomic number active material has been obtained using the absorption contrast mode, whereas the percolated solid network composed of active material and carbon-doped polymer binder domain (CBD) has been obtained using the Zernike phase contrast mode. The 3D absorption contrast image revealed that some LTO nano-particles tend to agglomerate and form secondary micro-sized particles with varying degrees of sphericity. The tortuosity of electrode’s pore and solid phases were found to have directional dependence, different from Bruggeman’s tortuosity commonly used in macro-homogeneous models. The electrode’s heterogeneous structure was investigated by developing a numerical model to simulate galvanostatic discharge process using the Zernike phase contrast mode. The inclusion of CBD in the Zernike phase contrast results in an integrated percolated network of active material and CBD that is highly suited for continuum modeling. As a result, the simulation results highlight the importance of using the real 3D geometry since the spatial distribution of physical and electrochemical properties have a strong non-uniformity due to microstructural heterogeneities.

25 ENERGY STORAGE↗

Flat plate electrohydrodynamic heat pipe experiments

Performance capabilities of electrohydrodynamic (EHD) flat heat pipes were investigated using Freon 113 and Freon 11 as working fluids. All of the pipes employed straight rod electrodes to form axial liquid flow channels and tranverse grooves for capillary surface wetting. Results show: (1) the EHD pipe will prime under load, (2) voltage controlled conductance can be achieved by varying the active area of the evaporator, and (3) the average evaporator conductances measured in these experiments were consistent with those obtained in other experiments with heat pipes of similar surface geometry using the same or similar working fluids.

Loehrke, R. I.↗

Effects of Ultramicroelectrode Dimensions on the Electropolymerization of Polypyrrole

Anode geometry can significantly affect the electrochemical synthesis of conductive polymers. Here, the effects of anode dimensions on the electropolymerization of pyrrole are investigated. Band microelectrodes were prepared with widths ranging from 2 to 500 {micro}m. The anode dimension has a significant effect on the resulting thickness of polymer film. The electropolymerization process deviates significantly from that predicted by simple mass transfer considerations when electrode dimensions are less than {approx}20 {micro}m. Polymer film thickness is thinner than expected when electrode dimensions become less than {approx}10 {micro}m. A simple mathematical model was derived to explain the observed effects of anode dimensions on the polymerization process. Simulation results confirm that diffusive loss of reaction intermediates accounts for the observed experimental trends. The described simulation facilitates understanding of the electropolymerization processes and approaches to the controlled deposition of polypyrrole, particularly at the submicron scale, for microelectromechanical systems and biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser plasmadynamic energy conversion

The generation of electrons ions by interacting an intense laser beam with cesium vapor is considered. Theoretical calculation shows that the conversion efficiency is as high as 40 percent if the entire photon energy is utilized in ionizing the cesium vapor that is generated initially by the incoming laser beam. An output voltage is expected to be generated across two electrodes, one of which is the liquid cesium, by keeping the other electrode at a different work function. Evaluation of the laser plasmadynamic (LPD) converter was performed using pulsed ruby and Nd-glass lasers. Although the results obtained to date indicate an efficiency smaller than that of theoretical predictions, an unoptimized LPD converter did demonstrate the capability of converting laser energy at large power levels. The limitations in the performance may by due to converter geometry, the types of lasers used, and other limitations inherent to the cesium plasma.

Shimada, K.↗