Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical switches”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Low modulation index 3-phase solid state transformer

A solid-state transformer (SST) comprises a transformer core, a primary winding, a secondary winding, a primary-side switch bank, and a secondary-side switch bank. Each of the switch banks includes six 4-quadrant switches. The twelve 4-quadrant switches are toggled on and off over six clock cycles in a repetitive sequence with a period that is a function of a desired operating frequency of the transformer. The sequence is configured such that at any given time, 2 of 3 input and output phases are connected to the primary and secondary windings. The SST further includes L-C filter circuits that are configured to filter high-frequency components of current and voltage waveforms such that these components are not back-fed to the electrical mains or delivered to a load. The SST includes a primary-side filter circuit and a secondary-side filter circuit that can each include respective L-C filters for three input or output phases.

Koplow, Jeffrey P.↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispersion of cryogenic hydrogen through high-aspect ratio nozzles

Liquid hydrogen is increasingly being used as a delivery and storage medium for stations that provide compressed gaseous hydrogen for fuel cell electric vehicles. In efforts to provide scientific justification for separation distances for liquid hydrogen infrastructure in fire codes, the dispersion characteristics of cryogenic hydrogen jets (50–64 K) from high aspect ratio nozzles have been measured at 3 and 5 bar abs stagnation pressures. These nozzles are more characteristic of unintended leaks, which would be expected to be cracks, rather than conventional round nozzles. Spontaneous Raman scattering was used to measure the concentration and temperature field along the major and minor axes. Within the field of interrogation, the axis-switching phenomena was not observed, but rather a self-similar Gaussian-profile flow regime similar to room temperature or cryogenic hydrogen releases through round nozzles. The concentration decay rate and half-widths for the planar cryogenic jets were found to be nominally equivalent to that of round nozzle cryogenic hydrogen jets indicating a similar flammable envelope. The results from these experiments will be used to validate models for cryogenic hydrogen dispersion that will be used for simulations of alternative scenarios and quantitative risk assessment.

08 HYDROGEN↗

Hybrid MBE Route to Adsorption-Controlled Growth of BaTiO 3 Membranes with Robust Polarization Switching

Freestanding ferroelectric membranes are promising for flexible electronics, nonvolatile memory, photonics, and spintronics, but their synthesis is challenged by the need for reproducibility with precise stoichiometric control. Here, we demonstrate the adsorption-controlled growth of single-crystalline, epitaxial BaTiO 3 films by hybrid molecular beam epitaxy (MBE) on a binary oxide sacrificial layer. Using a simple water-droplet lift-off method, we obtained submillimeter- to millimeter-sized membranes that retained crystallinity, as confirmed by high-resolution X-ray diffraction, and exhibited robust tetragonal symmetry, as verified by Raman spectroscopy. Impedance spectroscopy confirmed a high dielectric constant of ∼1340, reflecting the robust dielectric response of the membranes. Ferroelectric functionality was revealed by piezoresponse force microscopy (PFM) and further verified by polarization-electric field (P-E) loop measurements with Positive-Up-Negative-Down (PUND). The P-E loops exhibited a remnant polarization of ∼5 μC cm –2 and a coercive field of ∼63 kV cm –1 . Furthermore, these results were interpreted in relation to c- and a-domain configurations.

Raman spectroscopy↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Enhanced Performance of Dual Inverter with a Floating Capacitor for Motor Drive Applications

This paper studies a dual inverter supplied by a DC-link and a floating capacitor (FC), emerged as a promising inverter topology for motor drive applications. For this type of inverter, the voltage ratio between the DC-link and the FC can be actively controlled. This ratio design is crucial as it essentially defines both the DC-link voltage utilization and the inverter output quality. Several voltage ratios have previously been discussed to enhance the dual inverter performance, but only one aspect, either the voltage utilization or the output quality, is investigated. As a result, although one performance aspect can be improved, the other aspect has been adversely affected. In this work, a comparative study considering both aspects is carried out for all the possible voltage ratios. Based on this analysis, the optimal ratios for different inverter modulation indices are identified. This is followed by proposing a ratio selection strategy to double the voltage utilization without degrading the output quality. Furthermore, this strategy enables an electric drive to work at a higher maximum speed without flux weakening for a given DC-link voltage. The claimed advantages have been proved by experimental tests on an open-end windings induction motor drive.

42 ENGINEERING↗

Universal Battery Supercharger

During the course of the UBS project a dc-fast charger was developed to be used in off board high power charging stations. High efficiency is targeted to reduce the charging price for the consumer while reducing the charge time. In the meantime, the size of the converter is minimized so that it could be used in small spaces and potentially urban areas. The topology is modular, and the power level can be expanded for charging higher power vehicles like trucks and buses. During the course of this research several key technologies was developed in LESES that improve the performance of the power electronics system used in EV charger. Integrated magnetics was developed for DMCR to improve the power density as well as efficiency of the magnetic components which is one of the main bottlenecks of EV development. Triangular mode EV current conduction mode is using to perform soft switching (increase efficiency) without adding any new components to the existing topology. Passive and active damping are developed to suppress the interaction between grid and converter, stabilizing the control system. Further numerous other technical problems have been solved to pave the way for even higher performance converters in the future.

25 ENERGY STORAGE↗

NiSi: A New Venue for Antiferromagnetic Spintronics

Envisaging antiferromagnetic spintronics pivots on two key criteria of high transition temperature and tuning of underlying magnetic order using straightforward application of magnetic field or electric current. Here, it is shown that NiSi metal can provide suitable new platform in this quest. First, the study unveils high-temperature antiferromagnetism in single-crystal NiSi with Néel temperature, T N $\geqslant$ 700 K. Antiferromagnetic order in NiSi is accompanied by non-centrosymmetric magnetic character with small ferromagnetic component in the a–c plane. Second, it is found that NiSi manifests distinct magnetic and electronic hysteresis responses to field applications due to the disparity in two moment directions. While magnetic hysteresis is characterized by one-step switching between ferromagnetic states of uncompensated moment, electronic behavior is ascribed to metamagnetic switching phenomena between non-collinear spin configurations. Importantly, the switching behaviors persist to high temperature. In conclusion, the properties underscore the importance of NiSi in the pursuit of antiferromagnetic spintronics.

36 MATERIALS SCIENCE↗

Hexagonal Boron Nitride: Physical Properties, Hydride Vapor‐Phase Epitaxy Growth of Large‐Diameter Quasi‐Bulk Wafers and Applications

Hexagonal boron nitride ( h ‐BN), with its ultrawide bandgap and 2D structure, holds an immense promise for advanced semiconductor applications. Scaling bulk crystals to large‐diameter wafers, crucial for complex device fabrication, remains a challenge with high temperature, high pressure, and metal flux solution methods. To address this, recent efforts have focused on hydride vapor‐phase epitaxy (HVPE) for producing large diameter thick h ‐BN quasi‐bulk wafers, reaching hundreds of micrometers. These HVPE‐grown quasi‐bulk crystals exhibit excellent c ‐axis long‐range order. Notably, the in‐plane mobility‐lifetime products for both electrons and holes surpass 10 −4 cm 2 V −1 , which are two orders of magnitude greater than the out‐of‐plane (vertical) values, highlighting the potential for high‐performance devices leveraging superior lateral transport. Lateral detectors fabricated from 100 μm thick B‐10 enriched h‐ BN wafers have achieved a record 60% thermal neutron detection efficiency. Based on its physical properties, h‐ BN appears to be an outstanding material of choice for light‐triggered electronic power switches capable of supporting high ‐ voltage and high ‐ power operations. These recent advancements in large‐diameter h ‐BN quasi‐bulk crystal growth, enabled by HVPE, pave the way for applications spanning deep UV photonics, high‐power electronics, high‐efficiency neutron detection, and quantum information technologies, establishing h ‐BN as both a versatile active semiconductor and an ideal substrate.

Jiang, Hongxing [Department of Electrical and Comp↗

Systematic investigations on iron cycling in phosphorus/siderophore systems: Synergism or antagonism?

Synergisms between microbial exudates on Fe (hydr)oxide dissolution as an effective Fe acquisition pathway have been recently addressed and vigorously debated. However, Fe liberation mechanisms and where siderophores and phosphorus (P) coexist received little attentions. Current study systematically investigated ferrihydrite dissolution in the presence of desferrioxamine B (DFOB) (a kind of fungally-derived siderophores) and inorganic/organic phosphorus (orthophosphate, Pi; myo-inositol hexaphosphate, IHP), as a function of solute pH, reaction time and reagent content. Reacted solids were characterized by N 2 -BET adsorption, zeta (ζ) potential analysis, sequential extraction analysis (SEDEX), field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), micro Raman spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). Our results indicate that upon reaction with P-only or (DFOB + P) systems, interfacial complexation partially switched from monolayer bidentate-binuclear surface complexes to ternary complexes, or laterally transformed into amorphous Fe–P precipitates. The Fe-Pi complex precipitated more readily under acidic conditions, and Fe-IHP complex preferentially nucleated in neutral-alkaline environments. Phosphorus slightly promoted Fe release from minerals and fixation to the leached layer or interfacial liquid zone initially, but subsequently prevented further attacks from protons and DFOB. The co-effects of P and DFOB likely correspond to two successive scenarios: 1) DFOB is preferentially attracted toward ferrihydrite surfaces by negative electrical fields induced by adsorbed phosphorus and can act synergistically with labile P–Fe complexes, resulting in intensive temporal dissolution of Fh; 2) subsequent Fe shuttling to DFOB can be prohibited by stabilized, passive P/Fe–P layers. Finally, our results emphasize the antagonism between P compounds and siderophores (i.e., DFOB here) on ferrihydrite dissolution to improve understanding of the biologically-mediated Fe cycling in natural systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Orbital gyrotropic magnetoelectric effect and its strain engineering in monolayer NbX 2

Electrical control of the orbital degrees of freedom is an important area of research in the emerging field of "orbitronics.'' Orbital gyrotropic magneto-electric effect (OGME) is the generation of an orbital magnetization in a nonmagnetic metal by an applied electric field. Here, we show that strain induces a large GME in the monolayer NbX 2 (X = S, Se) normal to the plane, primarily driven by the orbital moments of the Bloch bands as opposed to the conventional spin magnetization, without any need for spin-orbit coupling. The key physics is captured within an effective two-band valley-orbital model and it is shown to be driven by three key ingredients: the intrinsic valley orbital moment, broken $C_{3z}$ symmetry, and strain-induced Fermi surface changes. The effect can be furthermore switched by changing the strain condition, with potential for future device applications.

2D materials↗

Total cost of ownership of vehicle electrification and fuel switching options for light-duty and heavy-duty vehicles

Projecting the transition from combustion engines to battery-based powertrains is complex becuase it involves numerous interdependent decisions. This study estimates total cost of ownership (TCO) to assess the economic viability of powertrain electrification, focusing exclusively on advances in vehicle and fuel technologies. Under two bounding technology-progress scenarios, we develop vehicle designs and fuel cost trajectories, which serve as inputs to TCO projections for selected classes from 2021 to 2050. We analyzed a small sport utility vehicle (SUV) to represent the light-duty vehicle (LDV) sector, and four medium- and heavy-duty vehicle (MHDV) classes: Class 6 box delivery, Class 8 drayage, Class 8 long-haul, and Class 8 transit bus. For each class, we compared the TCO of battery electric vehicles (BEVs) and fuel cell hybrid electric vehicles (FCHEVs) against conventional internal combustion engine vehicles (ICEVs). The results show that modern ICEVs generally have lower TCO; however, BEVs and FCHEVs could match or have lower TCOs than ICEVs over time, depending on technological progress. In LDVs, BEV300 is projected to deliver the lowest TCO by 2050, particularly under the high-progress scenario. In MHDVs, both BEVs and FCHEVs could become more cost-competitive than ICEVs by 2050 in the high-progress case. Beyond these results, the findings suggest further investigation is warranted for BEV charging infrastructure, FCHEV hydrogen refueling infrastructure, and MHDV charging strategies. In conclusion, these factors could reduce the fuel-cost share of TCO and enhance the competitiveness of BEVs and FCHEVs relative to ICEVs.

Battery electric vehicle↗

Investigation of Dynamic Temperature-Sensitive Electrical Parameters for Medium-Voltage Low-Current Silicon Carbide and Silicon Devices

This paper presents five dynamic temperature-sensitive electrical parameters (TSEPs) for the medium-voltage silicon carbide (SiC) and silicon (Si) devices. The theoretical temperature dependence of these parameters is analyzed. A test platform that enables to implement the temperature relevant dynamic characterization is developed. The tested TSEPs are summarized in terms of their relationship with junction temperature, drain/collector current, DC voltage, and external gate resistance. The comparison between the 3 kV 12 A Si IGBT and 3.3 kV 5 A SiC MOSFET with the identical TO-263 package is conducted. The results verify that the turn-off drain-source voltage switching rate achieves better thermal sensitivity for medium-voltage low-current SiC MOSFETs compared with Si IGBTs. Both the turn-on and turn-off delay time exhibit better thermal linearity for the two devices. The turn-off delay time further achieves five times better thermal sensitivity than the turn-on delay time for investigated medium-voltage SiC MOSFETs.

Ni, Ze↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗