Non-Hamiltonian perturbations of integrable systems and resonance trapping

This paper studies general, non-Hamiltonian perturbations of integrable systems with two degrees of freedom and derives conditions for temporary and permanent resonance trapping. The analysis involves a noncanonical transformation of variables near the resonant manifold and averaging with respect to the fast phase to investigate oscillatory behavior on the intermediate timescale. The resulting reduced system is Hamiltonian to leading order and permits, after averaging on the intermediate, or libration, timescale, a canonical transformation to action-angle variables in the oscillation zone. The final system so obtained reveals the possible existence of two- and three-dimensional invariant tori in the vicinity of the resonant manifold. An explicit divergence condition for general perturbations to be dissipative on the slow timescale follows from the analysis. An application of this approach to the problem of resonant trapping and escape is outlined for the restricted problem of three bodies subject to dissipative perturbations with a radial symmetry.

Ghil, M.↗

Multigrid Acceleration of Time-Accurate DNS of Compressible Turbulent Flow

An efficient scheme for the direct numerical simulation of 3D transitional and developed turbulent flow is presented. Explicit and implicit time integration schemes for the compressible Navier-Stokes equations are compared. The nonlinear system resulting from the implicit time discretization is solved with an iterative method and accelerated by the application of a multigrid technique. Since we use central spatial discretizations and no artificial dissipation is added to the equations, the smoothing method is less effective than in the more traditional use of multigrid in steady-state calculations. Therefore, a special prolongation method is needed in order to obtain an effective multigrid method. This simulation scheme was studied in detail for compressible flow over a flat plate. In the laminar regime and in the first stages of turbulent flow the implicit method provides a speed-up of a factor 2 relative to the explicit method on a relatively coarse grid. At increased resolution this speed-up is enhanced correspondingly.

Broeze, Jan↗

The Capture of Interstellar Dust: The Pure Poynting-Robertson Case

Ulysses and Galileo spacecraft have discovered interstellar dust particles entering the solar system. In general, particles trajectories not altered by Lorentz forces or radiation pressure should encounter the sun on open orbits. Under Newtonian forces alone these particles return to the interstellar medium. Dissipative forces, such as Poynting Robertson (PR) and corpuscular drag and non-dissipative Lorentz forces can modify open orbits to become closed. In particular, it is possible for the orbits of particles that pass close to the Sun to become closed due to PR drag. Further, solar irradiation will cause modification of the size of the dust particle by evaporation. The combination of these processes gives rise a class of capture orbits and bound orbits with evaporation. Considering only the case of pure PR drag a minimum impact parameter is derived for initial capture by Poynting-Robertson drag. Orbits in the solar radiation field are computed numerically accounting for evaporation with optical and material properties for ideal interstellar particles modeled. The properties of this kind of particle capture are discussed for the Sun but is applicable to other stars.

Jackson, A. A.↗

Flow Cage Assemblies

Apparatus, systems and methods for implementing flow cages and flow cage assemblies in association with high pressure fluid flows and fluid valves are provided. Flow cages and flow assemblies are provided to dissipate the energy of a fluid flow, such as by reducing fluid flow pressure and/or fluid flow velocity. In some embodiments the dissipation of the fluid flow energy is adapted to reduce erosion, such as from high-pressure jet flows, to reduce cavitation, such as by controllably increasing the flow area, and/or to reduce valve noise associated with pressure surge.

Sherrit, Stewart↗

Constraints on impact rates in the Pluto-Charon system and the population of the Kuiper comet belt

Impact rates in the Pluto-Charon system are dominated by comets from the proposed Kuiper Belt, 30 to 50 AU from the sun. Such collisions excite the eccentricity of Charon's orbit, which then decays due to tidal dissipation. Charon's eccentricity approaches a quasi-steady state, which can be used to constrain the total number and mass of comets in the Kuiper Belt. Unfortunately, the current upper limit on Charon's orbital eccentricity must be reduced by more than a factor of ten before useful constraints can be set.

Weissman, Paul R.↗

Multifractal scaling of the kinetic energy flux in solar wind turbulence

The geometrical and scaling properties of the energy flux of the turbulent kinetic energy in the solar wind have been studied. By present experimental technology in solar wind measurements, we cannot directly measure the real volumetric dissipation rate, epsilon(t), but are constrained to represent it by surrogating the energy flux near the dissipation range at the proton gyro scales. There is evidence for the multifractal nature of the so defined dissipation field epsilon(t), a result derived from the scaling exponents of its statistical q-th order moments. The related generalized dimension D(q) has been determined and reveals that the dissipation field has a multifractal structure. which is not compatible with a scale-invariant cascade. The associated multifractal spectrum f(alpha) has been estimated for the first time for MHD turbulence in the solar wind. Its features resemble those obtained for turbulent fluids and other nonlinear multifractal systems. The generalized dimension D(q) can, for turbulence in high-speed streams, be fitted well by the functional dependence of the p-model with a comparatively large parameter, p = 0.87. indicating a strongly intermittent multifractal energy cascade. The experimental value for D(p)/3, if used in the scaling exponent s(p) of the velocity structure function, gives an exponent that can describe some of the observations. The scaling exponent mu of the auto correlation function of epsilon(t) has also been directly evaluated. It has the value of 0.37. Finally. the mean dissipation rate was determined, which could be used in solar wind heating models.

Marsch, E.↗

High-Performance electronics at ultra-low power consumption for space applications: From superconductor to nanoscale semiconductor technology

A detailed review of Sandia's work in ultralow power dissipation electronics for space flight applications, including superconductive electronics, new advances in quantum well structures, and ultra-high purity 3-5 materials, and recent advances in micro-electro-optical-mechanical systems (MEMS) is presented. The superconductive electronics and micromechanical devices are well suited for application in micro-robotics, micro-rocket engines, and advanced sensors.

Duncan, Robert V.↗

Thermo-Mechanical Analyses of Dynamically Loaded Rubber Cylinders

Thick rubber components are employed by the Army to carry large loads. In tanks, rubber covers road wheels and track systems to protect roadways. It is difficult for design engineers to simulate the details of the hysteretic heating for large strain viscoelastic deformations. In this study, an approximation to the viscoelastic energy dissipated per unit time is investigated for use in estimating mechanically induced viscoelastic heating. Coupled thermo-mechanical simulations of large cyclic deformations of rubber cylinders are presented. The cylinders are first compressed axially and then cyclically loaded about the compressed state. Details of the algorithm and some computational issues are discussed. The coupled analyses are conducted for tall and short rubber cylinders both with and without imbedded metal disks.

Johnson, Arthur R.↗

Linear Multivariable Regression Models for Prediction of Eddy Dissipation Rate from Available Meteorological Data

Linear multivariable regression models for predicting day and night Eddy Dissipation Rate (EDR) from available meteorological data sources are defined and validated. Model definition is based on a combination of 1997-2000 Dallas/Fort Worth (DFW) data sources, EDR from Aircraft Vortex Spacing System (AVOSS) deployment data, and regression variables primarily from corresponding Automated Surface Observation System (ASOS) data. Model validation is accomplished through EDR predictions on a similar combination of 1994-1995 Memphis (MEM) AVOSS and ASOS data. Model forms include an intercept plus a single term of fixed optimal power for each of these regression variables; 30-minute forward averaged mean and variance of near-surface wind speed and temperature, variance of wind direction, and a discrete cloud cover metric. Distinct day and night models, regressing on EDR and the natural log of EDR respectively, yield best performance and avoid model discontinuity over day/night data boundaries.

MCKissick, Burnell T.↗

Clogging of Joule-Thomson Devices in Liquid Hydrogen Handling

Experiments conducted at the NASA Glenn Research Center indicate that Joule-Thomson devices become clogged when transferring liquid hydrogen (LH2), operating at a temperature range from 20.5 to 24.4 K. Blockage does not exist under all test conditions but is found to be sensitive to the inlet temperature of the LH2. At a subcooled inlet temperature of 20.5 K blockage consistently appears but is dissipated when the fluid temperature is raised above 24.5 K. Clogging steadily reduced flow rate through the orifices, eventually resulting in complete blockage. This tendency poses a threat to spacecraft cryogenic propulsion systems that would utilize passive thermal control systems. We propose that this clogging is due to trace amounts of neon in the regular LH2 supply. Neon freezes at 24.5 K at one atmosphere pressure. It is postulated that between 20.5 and 24.5 K, neon remains in a meta-stable, supercooled liquid state. When impacting the face of an orifice, liquid neon droplets solidify and accumulate, blocking flow over time. The purpose of this test program was to definitively quantify the phenomena experimentally by obtaining direct visual evidence of orifice clogging by accretion from neon contaminates in the LH2 flow stream, utilizing state of the art imaging technology. Tests were conducted with LH2 flowing in the temperature range of 20.5 to 24.4 K. Additional imaging was also done at LH2 temperatures with no flow to verify clear view through the orifice.

Jurns, John M.↗

Spline approximations for nonlinear hereditary control systems

A sline-based approximation scheme is discussed for optimal control problems governed by nonlinear nonautonomous delay differential equations. The approximating framework reduces the original control problem to a sequence of optimization problems governed by ordinary differential equations. Convergence proofs, which appeal directly to dissipative-type estimates for the underlying nonlinear operator, are given and numerical findings are summarized.

Daniel, P. L.↗

Coherent interannual and decadal variations inthe atmosphere-ocean system

We investigate the source of poleward propagating atmospheric zonal wind anomalies, originating at the equator and penetrating to high latitudes in both hemispheres in conjunction with ENSO [Dickey et al.,1992], and report the discovery of similar variability on decadal and longer timescales. Since atmospheric dissipation times are generally on the order of a month or less, we examine the ocean as a 'memory' source for these globally coherent anomalies. This hypothesis is substantiated by the observation of complementaryoscillation in the sea surface temperature (SST) field; further, we detect a robust decadal variability (~1012 yrs)in both the SST and contemporaneous atmospheric angular momentum (AAM) series. Analyzing GISST SST data beginning in 1902, we confirm this decadal mode and find signatures of longer (multidecadal) SST variability centered in the equatorial and North Pacific.

coherent decadal meridional↗

Continuum Covariance Propagation for Understanding Variance Loss in Advective Systems

We demonstrate for state dynamics governed by the continuity equation and related hyperbolic partial differential equations that significant, spurious variance loss occurs during covariance propagation by traditional methods used in data assimilation, even at full rank. This inaccurate variance evolution is caused not by numerical dissipation, but rather by a discontinuous change in the continuum covariance dynamics as correlation lengths tend to zero.

Shay Gilpin↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗

Ice-Borehole Probe

An instrumentation system has been developed for studying interactions between a glacier or ice sheet and the underlying rock and/or soil. Prior borehole imaging systems have been used in well-drilling and mineral-exploration applications and for studying relatively thin valley glaciers, but have not been used for studying thick ice sheets like those of Antarctica. The system includes a cylindrical imaging probe that is lowered into a hole that has been bored through the ice to the ice/bedrock interface by use of an established hot-water-jet technique. The images acquired by the cameras yield information on the movement of the ice relative to the bedrock and on visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-data-transmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At thime of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the adjacent water and ice.

Behar, Alberto↗

Thermal testing of a high powered communications satellite

Thermal Vacuum and Thermal Balance tests were successfully conducted on the high power Communications Technology Satellite (CTS). The mission required testing for two distinct thermal environments; spin stabilized at 60 rpm with a minimum of 55 watts of dissipated power, and three-axis stabilized with as much as a tenfold increase of dissipation. The test program verified the adequacy of the spacecraft thermal design and demonstrated functional operation over a wide temperature range for all of the components. Special test hardware incorporating water-cooling systems was required to accomodate the heatpipes and high RF output power. Objectives, test facilities, special hardware, spacecraft configurations, and results of the tests are discussed. Preliminary flight results and conclusions drawn from the test experience are reported.

Caswell, R. D.↗

Orbital performance of a one-year lifetime superfluid helium dewar based on ground testing and computer modelling

The ground-test results of the 550-liter superfluid-He dewar built for IRAS are presented and discussed, and a computer projection of its orbital performance life is developed. The ground-testing program included flow-swap, cold-flow, power-off, hot/cold-viewport, and strap-thermal-efficiency tests. After one set of trials, some design changes were made, and the thermal-network computer model of the system was modified as well. The driving boundary conditions of dewar orbital operation used in this model are vacuum-shell temperature = 170 K, aperture heating = 8.0 mW, and focal-plane power dissipation = 16.2 mW. An operational lifetime of 319 days and an He loss rate of 2.54 mg/sec are predicted.

Hopkins, R. A.↗