Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Free-field propagation of high intensity noise

Research on high intensity (finite amplitude) acoustic waves shows that nonlinear distortion effects generally result in a shift of energy to higher frequencies. The higher intensities associated with supersonic jets would therefore indicate that high frequency enhancement of the spectrum should occur, resulting in the differences observed between subsonic and supersonic jets. A 10,000 acoustic watt source installed in an anechoic chamber generates sound levels such that acoustic shocks are readily observable. Dual frequency excitation of the source produces a strong parametric effect with a difference frequency comparable in level to the primary frequency. The test set up and recording equipment being used to determine the finite amplitude noise representative of an actual supersonic jet are described as well as the development of a computer program based on Burger's equation. The spectra of 1/2 octave band, 1 kHz sine wave, and dual frequency input and output are presented in graphs along with waveforms at Z = .025, 0.1, and 1.0.

Mcdaniel, O. H.↗

On the Use of Experimental Methods to Improve Confidence in Educed Impedance

Results from impedance eduction methods developed by NASA Langley Research Center are used throughout the acoustic liner community. In spite of recent enhancements, occasional anomalies persist with these methods, generally at frequencies where the liner produces minimal attenuation. This investigation demonstrates an experimental approach to educe impedance with increased confidence over a desired frequency range, by combining results from successive tests with different cavity depths. A series of tests is conducted with three wire-mesh facesheets, for which the results should be weakly dependent on source sound pressure level and mean grazing flow speed. First, a raylometer is used to measure the DC flow resistance of each facesheet. These facesheets are then mounted onto a frame and a normal incidence tube is used to determine their respective acoustic impedance spectra. A comparison of the acoustic resistance component with the DC flow resistance for each facesheet is used to validate the measurement process. Next, each facesheet is successively mounted onto three frames with different cavity depths, and a grazing flow impedance tube is used to educe their respective acoustic impedance spectra with and without mean flow. The no-flow results are compared with those measured in the normal incidence tube to validate the impedance eduction method. Since the anti-resonance frequency varies with cavity depth, each sample provides robust results over a different frequency range. Hence, a combination of results can be used to determine the facesheet acoustic resistance. When combined with the acoustic reactance, observed to be weakly dependent on the source sound pressure level and grazing flow Mach number, the acoustic impedance can be educed with increased confidence. Representative results of these tests are discussed, and the complete database is available in electronic format upon request.

Jones, Michael G.↗

A Channelized 2nd IF/LO Downconverter for the E0S Microwave Limb Sounder

The Earth Observing System (EOS) Microwave Limb Sounder (MLS) is scheduled for launch in 2004 on the EOS Aura spacecraft. The design, assembly and test of the flight 2nd Intermediate Frequency/ Local Oscillator (2nd IF/LO) subsystem for this instrument has been completed and is presented here. The 2nd IF/LO subsystem consists of 5 separate microwave assemblies, 1 for each of the 5 millimeter wave radiometer front ends, providing a total of 33 separate IF channels. Some key requirements of the subsystem are as follows: provide frequency multiplexing of overlapping or closely spaced 1st IF channels while maintaining low ripple in the passbands; generate 19 different 2nd LO frequencies, in the range of 4-20 GHz, with low phase noise and a placement resolution of 400 KHz; downconvert the 1st IF's to a common 2nd IF frequency centered at 900 MHz; minimize cost and schedule by using common designs for the 5 different assemblies wherever possible.

intermediate frequency/local oscillator (IF/LO)↗

Global QBO in circulation and ozone. Part 1: Reexamination of observational evidence

Observational evidence for a global quasi-biennial oscillation (QBO) pattern is reviewed. In particular, the presence of an extratropical, as well as an equatorial, component of the QBO signal in column ozone is established. It is found that the ozone interannual variability is such that as one moves away from the Tropics, the frequency spectrum of the anomaly changes from one that is dominated by the equatorial QBO frequency of 1/30 mo to a two-peak spectrum around the two frequencies: 1/30 mo and 1/20 mo. Instead of treating the 1/20 mo frequency as a separate phenomenon to be filtered away in extracting the QBO in the extratropics, as was previously done, the authors argue that both peaks are integral parts of the extratropical QBO phenomenon. The 1/20 mo frequency happens to be the difference combination of the QBO frequency 1/30 mo and the annual frequency 1/12 mo. Therefore, it can represent the result of the QBO modulating an annual cycle. The authors suggest that previous methods of extracting the extratropical QBO signal severely underestimated the contribution of the QBO to the interannual variability of ozone when data are filtered to pass only the component with the period of equatorial QBO. Further, it is argued that the transport of equatorial QBO ozone anomaly by a non-QBO circulation can at most account for 6-8 Dobson units (DU) of the observed interannual variability of column ozone in the extratropics. The remaining variability (up to 20 DU) probably cannot be produced without an anomaly in the transporting circulation in the extratropics.

Tung, K. K.↗

Microwave Oscillators Based on Nonlinear WGM Resonators

Optical oscillators that exploit resonantly enhanced four-wave mixing in nonlinear whispering-gallery-mode (WGM) resonators are under investigation for potential utility as low-power, ultra-miniature sources of stable, spectrally pure microwave signals. There are numerous potential uses for such oscillators in radar systems, communication systems, and scientific instrumentation. The resonator in an oscillator of this type is made of a crystalline material that exhibits cubic Kerr nonlinearity, which supports the four-photon parametric process also known as four-wave mixing. The oscillator can be characterized as all-optical in the sense that the entire process of generation of the microwave signal takes place within the WGM resonator. The resonantly enhanced four-wave mixing yields coherent, phase-modulated optical signals at frequencies governed by the resonator structure. The frequency of the phase-modulation signal, which is in the microwave range, equals the difference between the frequencies of the optical signals; hence, this frequency is also governed by the resonator structure. Hence, further, the microwave signal is stable and can be used as a reference signal. The figure schematically depicts the apparatus used in a proof-of-principle experiment. Linearly polarized pump light was generated by an yttrium aluminum garnet laser at a wavelength of 1.32 microns. By use of a 90:10 fiber-optic splitter and optical fibers, some of the laser light was sent into a delay line and some was transmitted to one face of glass coupling prism, that, in turn, coupled the laser light into a crystalline CaF2 WGM disk resonator that had a resonance quality factor (Q) of 6x10(exp 9). The output light of the resonator was collected via another face of the coupling prism and a single-mode optical fiber, which transmitted the light to a 50:50 fiber-optic splitter. One output of this splitter was sent to a slow photodiode to obtain a DC signal for locking the laser to a particular resonator mode. The other output of this splitter was combined with the delayed laser signal in another 50:50 fiber-optic splitter used as a combiner. The output.of the combiner was fed to a fast photodiode that demodulated light and generated microwave signal. In this optical configuration, the resonator was incorporated into one arm of a Mach-Zehnder interferometer, which was necessary for the following reasons: It was found that when the output of the resonator was sent directly to a fast photodiode, the output of the photodiode did not include a measurable microwave signal. However, when the resonator was placed in an arm of the interferometer and the delay in the other arm was set at the correct value, the microwave signal appeared. Such behavior is distinctly characteristic of phase-modulated light. The phase-modulation signal had a frequency of about 8 GHz, corresponding to the free spectral range of the resonator. The spectral width of this microwave signal was less than 200 Hz. The threshold pump power for generating the microwave signal was about 1 mW. It would be possible to reduce the threshold power by several orders of magnitude if resonators could be made from crystalline materials in dimensions comparable to those of micro-resonators heretofore made from fused silica.

Maleki, Lute↗

Circuit for Driving Piezoelectric Transducers

The figure schematically depicts an oscillator circuit for driving a piezoelectric transducer to excite vibrations in a mechanical structure. The circuit was designed and built to satisfy application-specific requirements to drive a selected one of 16 such transducers at a regulated amplitude and frequency chosen to optimize the amount of work performed by the transducer and to compensate for both (1) temporal variations of the resonance frequency and damping time of each transducer and (2) initially unknown differences among the resonance frequencies and damping times of different transducers. In other words, the circuit is designed to adjust itself to optimize the performance of whichever transducer is selected at any given time. The basic design concept may be adaptable to other applications that involve the use of piezoelectric transducers in ultrasonic cleaners and other apparatuses in which high-frequency mechanical drives are utilized. This circuit includes three resistor-capacitor networks that, together with the selected piezoelectric transducer, constitute a band-pass filter having a peak response at a frequency of about 2 kHz, which is approximately the resonance frequency of the piezoelectric transducers. Gain for generating oscillations is provided by a power hybrid operational amplifier (U1). A junction field-effect transistor (Q1) in combination with a resistor (R4) is used as a voltage-variable resistor to control the magnitude of the oscillation. The voltage-variable resistor is part of a feedback control loop: Part of the output of the oscillator is rectified and filtered for use as a slow negative feedback to the gate of Q1 to keep the output amplitude constant. The response of this control loop is much slower than 2 kHz and, therefore, does not introduce significant distortion of the oscillator output, which is a fairly clean sine wave. The positive AC feedback needed to sustain oscillations is derived from sampling the current through the piezoelectric transducer. This positive AC feedback, in combination with the slow feedback to the voltage-variable resistors, causes the overall loop gain to be just large enough to keep the oscillator running. The positive feedback loop includes two 16-channel multiplexers, which are not shown in the figure. One multiplexer is used to select the desired piezoelectric transducer. The other multiplexer, which is provided for use in the event that there are significant differences among the damping times of the 16 piezoelectric transducers, facilitates changing the value of one of the resistors in the positive-feedback loop to accommodate the damping time of the selected transducer.

Randall, David P.↗

Navigational demands of low-level helicopter flight

The present study was designed to assess the verbal references to map, terrain, direction, and position, that navigators and pilots communicate during a simulated low-level flight. Two-person crews were asked to communicate normally while negotiating six short flight missions that varied widely in regard to map-terrain characteristics. Half of the crews performed the exercises with fixed, north-up maps and the other half used movable maps that were adjusted to maintain a track-up correspondence to the flight route. An analysis was performed to compare differences in crew communication patterns between map orientations, characteristics, and navigation tasks. The results showed differences in the frequency of communication across categories for map characteristics but not for map orientations or tasks. A difference in the proportion of communications between pilot and navigator occurred when crew were lost. Pilots communicated more than navigators when crews were lost and the reverse was true when crews were not lost. The results support and extend findings from a distance error performance analysis performed on the same flight missions.

Delzell, Susanne↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Chromosome Aberrations in Normal and Ataxia-Telangiectasia Cells Exposed to Heavy Ions

Although cells derived from Ataxia Telangiectasia (AT) patients are known to exhibit abnormal responses to ionizing radiations, its underlying mechanism still remains unclear. Previously, the authors reported that at the same gamma-irradiation dose AT cells show higher frequencies of misrepair and deletions compared to normal human fibroblast cells. In this study, we investigated the effects of heavy ions beams on chromosomal aberrations in normal and AT cells. Normal and AT fibroblast cells arrested at G0/G1 phase were irradiated with 2 Gy of X-rays, 490 MeV/u Silicon (LET 55 keV/m), 500 MeV/u Iron (LET 185 keV/m) and 200 MeV/u Iron (LET 440 keV/m) particles, and then cells were allowed to repair for 24 hours at 37 degrees before subculture. Calyculin-A induced PCC method was employed to collect G2/M chromosomes and whole DNA probes 1 and 3 were used to analyze chromosomal aberrations such as color-junctions, deletions, simple exchanges (incomplete and reciprocal exanges) and complex-type exchanges. The percentages of aberrant cells were higher when normal and AT cells were exposed to heavy ions compared to X-rays, and had a tendency to increase with increasing LET up to 185 keV/m and then decreased at 440 keV/m. When the frequency of color-junctions per cell was compared after X-ray exposure, AT cells had around three times higher frequency of color-junctions (mis-rejoining) than normal cells. However, at 185 keV/m there was no difference in the frequency of color-junctions between two cell lines. It was also found that the frequency of simple exchanges per cell was almost constant in AT cells regardless LET levels, but it was LET dependent for normal cells. Interestingly, the frequency of simple exchanges was higher for AT cells when it was compared at 185 keV/m but AT cells had more complex-type exchanges at the same LET levels. Heavy ions are more efficient in inducing chromosome aberrations in normal and AT cells compared to X-rays, and the aberration types between normal and AT fibroblast appeared different probably due to difference in the ATM gene function.

Kawata, T.↗

Hyper-ballistic transport models of Copernican ejecta

As the ejecta curtain sweeps outward from the crater which forms after meteorite impact, fine particles may receive a hyperballistic boost from the expanding gas cloud created by vaporization. In modeling the phenomenon, this paper considers both spatial and frequency variations of the particle size parameter. Two models which preserve spatial homogeneity within the elliptical transient crater serve to test the effects of different particle-frequency distributions. Three models which feature identical spatial nonhomogeneity of particle sizes serve to test different crater-formation rates. From 1 to 6% of the total ejected mass is sent beyond the maximum ballistic range of 437 km, according to the five models, each of which is a possible simulation of the lunar crater Copernicus.

Rehfuss, D. E.↗

Electron density profiles in the background of LF absorption during Forbush-decrease and PSE

Based on the simulation of different Forbush decrease and particle precipitation effects in the D region, electron density profiles in the mid-latitudes the ionospheric absorption of low frequency (LF) radio waves was determined. The absorption variations at different frequenceis are strongly affected by the shape of the electron density profile. A structure appears which sometimes resembles the letter S (in a sloping form). Both the height (around 70 to 72 km) and the depth of the local minimum in the electron density contribute to the computed absorption changes of various degree at different frequencies. In this way several observed special absorption events can be interpreted.

Satori, G.↗

Laser Heterodyne Radiometer for Sensitive Detection of CO2 and CH4

We propose to develop an inexpensive, miniaturized, passive laser heterodyne radiometer (LHR) using commercially available telecommunications laser components to measure two significant carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). This instrument would operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach that supports the Decadal Survey. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In a laser heterodyne radiometer, the weak input signal is light that has undergone absorption by a trace gas. The local oscillator is a laser at a near-by frequency - in this case a low-cost distributed feedback (DFB) telecommunications laser. These two light waves are superimposed in either a beamsplitter or in a fiber coupler (as is the case in this design). The signals are mixed in the detector, and the RF beat frequency is extracted. Changes in concentration of the trace gas are realized through analyzing changes in the beat frequency amplitude. A schematic of the progression of the LHR development project is shown in the figure below. At the center (within the dashed line), light from the local oscillator is superimposed upon light that has undergone absorption by a trace gas, in a single mode fiber coupler. Superimposed light is mixed in a fast photoreceiver, and the beat signal is analyzed for changes in absorption. The left portion of the figure depicts a progression of light sources that pass through the trace gas, increasing in complexity in the downward direction. On the right side of the figure, RF signal processing progresses from a commercially available spectrum analyzer to a RF receiver, and finally to an RF filter bank to deconvolute portions of the beat frequency more heavily weighted for different altitudes.

Wilson, Emily L.↗

Squeezing Alters Frequency Tuning of WGM Optical Resonator

Mechanical squeezing has been found to alter the frequency tuning of a whispering-gallery-mode (WGM) optical resonator that has an elliptical shape and is made of lithium niobate. It may be possible to exploit this effect to design reconfigurable optical filters for optical communications and for scientific experiments involving quantum electrodynamics. Some background information is prerequisite to a meaningful description of the squeezing-induced alteration of frequency tuning: The spectrum of a WGM resonator is represented by a comblike plot of intensity versus frequency. Each peak of the comblike plot corresponds to an electromagnetic mode represented by an integer mode number, and the modes are grouped into sets represented by integer mode indices. Because lithium niobate is an electro-optically active material, the WGM resonator can be tuned (that is, the resonance frequencies can be shifted) by applying a suitable bias potential. The frequency shift of each mode is quantified by a tuning rate defined as the ratio between the frequency shift and the applied potential. In the absence of squeezing, all modes exhibit the same tuning rate. This concludes the background information. It has been demonstrated experimentally that when the resonator is squeezed along part of either of its two principal axes, tuning rates differ among the groups of modes represented by different indices (see figure). The differences in tuning rates could be utilized to configure the resonance spectrum to obtain a desired effect; for example, through a combination of squeezing and electrical biasing, two resonances represented by different mode indices could be set at a specified frequency difference something that could not be done through electrical biasing alone.

Mohageg, Makan↗

Linkage among Ice Crystal Microphysics, Mesoscale Dynamics and Cloud and Precipitation Structures Revealed By Collocated Microwave Radiometer and Multi-Frequency Radar Observations

Ice clouds and falling snow are ubiquitous globally and play important roles in the Earth’s radiation budget and precipitation processes. Ice particle microphysical properties (e.g., size, habit and orientation) are not only influenced by ambient environment’s dynamic and thermodynamic conditions, but also intimately connect to the cloud radiative effects and particle fall speeds, which therefore impact up to the future climate projection and down to the details of the surface precipitation (e.g., onset-time, location, type and strength). Our previous work revealed that high-frequency Polarimetric radiance Difference (PD) from passive microwave sensors is a good indicator of the bulk aspect ratio of horizontally oriented ice particles that are often occur inside anvil clouds and/or stratiform precipitations. In this current work, we further investigate the dynamic/thermodynamic mechanisms and cloud/precipitation structures associated with ice-phase microphysics corresponding to different PD signals. In order to do so, collocated CloudSat radar (W-band) and Global Precipitation Measurement Dual-frequency Precipitation Radar (GPM-DPR, Ku/Ka bands) observations as well as European Centre for Medium-Range Weather Forecasts (ECMWF) atmosphere background profiles are grouped according to the magnitude of PD for only stratiform precipitation and/or anvil cloud scenes. We found that horizontally-oriented snow aggregates or large snow particles are likely the major contributor to the high-PD signals at 166 GHz, while low-PD magnitudes can be attributed to small cloud ice, randomly oriented snow aggregates, riming snow or super-cooled water. Further, high (low) PD scenes are found to be associated with stronger (weaker) wind shear and higher (lower) ambient humidity, both of which help promote (prohibit) the growth of frozen particles and the organization of convective systems. An ensemble of squall line cases is studied at the end to demonstrate that the PD asymmetry in the leading and trailing edges of the deep convection line is closely tied to the anvil cloud and stratiform precipitation layers respectively, suggesting the potential usefulness of PD as a proxy of stratiform/convective precipitation flag, as well as a proxy of convection life stage.

Ice crystal microphysics↗

Time and frequency-domain identification and verification of BO-105 dynamic models

Mathematical models for the dynamics of the DLR BO 105 helicopter are extracted from flight test data using two different approaches: frequency-domain and time-domain identification. Both approaches are reviewed. Results from an extensive data consistency analysis are given. Identifications for 6 degrees of freedom (DOF) rigid body models are presented and compared in detail. The extracted models compare favorably and their prediction capability is demonstrated in verification results. Approaches to extend the 6 DOF models are addressed and first results are presented. System identification is broadly defined as the deduction of system characteristics from measured data. It provides the only possibility to extract both non-parametric (e.g., frequency responses) and parametric (e.g., state space matrices) aircraft models from flight test data and therefore gives a reliable characterization of the dynamics of the actually existing aircraft. Main applications of system identification are seen in areas where higher accuracies of the mathematical models are required: Simulation validation, control system design (in particular model-following control system design for in-flight simulation), and handling qualities.

Kaletka, Juergen↗

Time and frequency-domain identification and verification of BO-105 dynamic models

Mathematical models for the dynamics of the DLR BO 105 helicopter are extracted from flight test data using two different approaches: frequency-domain and time-domain identification. Both approaches are reviewed. Results from an extensive data consistency analysis are given. Identifications for 6 degrees of freedom (DOF) rigid body models are presented and compared in detail. The extracted models compare favorably and their prediction capability is demonstrated in verification results. Approaches to extend the 6 DOF models are addressed and first results are presented. System identification is broadly defined as the deduction of system characteristics from measured data. It provides the only possibility to extract both non-parametric (e.g., frequency responses) and parametric (e.g., state space matrices) aircraft models from flight test data and therefore gives a reliable characterization of the dynamics of the actually existing aircraft. Main applications of system identification are seen in areas where higher accuracies of the mathematical models are required: Simulation validation, control system design (in particular model-following control system design for in-flight simulation), and handling qualities.

Kaletka, Juergen↗

Transponder System for High-Frequency Ranging

Transponder system uses phase difference between transmitted and reflected high-frequency radio waves to measure distance to target. To suppress spurious measurements of reflections from objects near target at transmitted frequency and its harmonics, transponder at target generates return signal at half transmitted frequency. System useful in such applications as surveying, docking of ships, and short-range navigation.

Lichtenberg, C. L.↗