Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Interfacial shear behavior of sapphire-reinforced NiAl composites

The interfacial shear behavior in near-equiatomic NiAl reinforced by sapphire filaments has been examined at room temperature using a fiber pushout test technique. The load-displacement data indicate a large variability in the initial interface failure stress, although reverse push behavior indicates a comparatively constant interfacial sliding friction stress. The observed behavior suggests that the presence of asperities on the fiber surfaces and nonuniformities in fiber diameter require constrained plastic flow within the NiAl matrix in order for interfacial shear to occur. The location, shape, severity, and distribution of fiber asperities as well as the uniformity of fiber diameter are critical to the interfacial shear process.

Moose, C. A.↗

Kinetics of small single particle combustion of zirconium alloy

We present quantitative kinetic information regarding small, 1-10 {mu}m in diameter, single particle combustion of Zr-rich metal alloy foils subjected to either mechanical impacts or laser-ablation. The lights from combustion of metal fragments were recorded on a high-speed camera. The particle size was determined by the motion analysis of individual particle trajectory based on an aerodynamic drag law and further verified by the microstructure and chemical composition analysis of recovered post-burn particles. The measured particle sizes show a log-normal distribution centered at around 3.1 {mu}m in diameter, and the composition of recovered particles is that of fully oxidized ZrO{sub 2}. The temperature evolution of each particle along the space/time-trajectory is determined based on the thermal emission from combustion using a single-color photographic spectro-pyrometry. The result indicates that the particle has reached the maximum combustion temperature of 4000 K, well beyond the melting temperature of ZrO{sub 2}, and undergone the solidification of molten ZrO{sub 2} during the cooling stage. It also shows that the maximum combustion temperature decreases linearly with increasing the particle diameter, following the correlation t aD{sup 1.5-1.8} between the burn time (t) and the particle diameter (D). Combining the particle size, the burn time, and the particle temperature, both temperature and mass burn rates are obtained as a function of particle size. As the particle size increases, the temperature burn rate decreases, whereas the mass burn rate goes in the opposite direction.

36 MATERIALS SCIENCE↗

Origin and relative age of lunar and Mercurian intercrater plains

Differences in the diameter/density distribution of craters in the size range 7-100 km between heavily cratered areas and areas of intercrater plains indicate the deposition of both lunar and Mercurian intercrater plains has preferentially obliterated craters not greater than about 30 km diameter. This obliteration has altered the original lunar population distribution function from about a -1.3 slope to about -0.7 slope. At least a significant portion of both the lunar and Mercurian intercrater plains appear to be volcanic deposits emplaced during the later stages of heavy bombardment on each body rather than basin ejecta or an ancient primordial surface. The very widespread distribution of intercrater plains on Mercury compared to the moon may be related to Mercury's core formation which would have resulted in a large radius increase leading to widespread extensional fracturing to provide egress for the eruption of volcanic deposits on a global scale. This was followed by a radius decrease due to contraction of the lithosphere to produce thrust faulting represented by Mercury's lobate scarps.

Strom, R. G.↗

Effects of Non-Sphericity on Mineral Dust Modeling

The dependency of non-sphericity on gravitational settling of mineral dust particles is parameterized for prolate ellipsoids and Reynolds number lower than 2. The settling speed is numerically solved from the momentum equation as a function of particle diameter and aspect ratio. The reduction of settling speed due to non-sphericity is included in the GO-CART model to simulate dust size distribution for April 2001. Two numerical schemes for solving sedimentation are compared. For particles of diameter greater than 5 micron the simulated size distribution is sensitive to the numerical sedimentation scheme. Changing the particle shape from spherical to non-spherical with lambda=2, makes little difference to the simulated surface concentration and size distribution except at the periphery of the dust sources. However, when very elongated particles (lambda=5) are simulated the differences between non-spherical and spherical particles are significant. With limited in-situ measurements reporting most frequent lambda around 1.5, the overall effects on global modeling is rather negligible and the essential benefit is to relax the CFL condition of Eulerian settling schemes.

Ginoux, Paul↗

Aerosol Physics Considerations for Using Cerium Oxide CeO 2 as a Surrogate for Plutonium Oxide PuO 2 in Airborne Release Fraction Measurements for Storage Container Investigations

Cerium oxide (CeO2) dust is recommended as a surrogate for plutonium oxide (PuO2) in airborne release fraction experiments. The total range of applicable particle sizes for PuO2 extends from 0.0032 μm (the diameter of a single PuO2 molecule) to 10 μm (the defined upper boundary for respirable particles). For particulates with a physical particle diameter of 1.0 μm, the corresponding aerodynamic diameters for CeO2 and PuO2 are 2.7 μm and 3.4 μm, respectively. Cascade impactor air samplers are capable of measuring the size distributions of CeO2 or PuO2 particulates. In this document, the aerodynamic diameters for CeO2 and PuO2 were calculated for seven different physical diameters (0.0032, 0.02, 0.11, 0.27, 1.0, 3.2, and 10 μm). For cascade impactor measurements, CeO2 and PuO2 particulates with the same physical diameter would be collected onto the same or adjacent collection substrates. The difference between the aerodynamic diameter of CeO2 and PuO2 particles (that have the same physical diameter) is 39% of the resolution of a twelve-stage MSP Inc. 125 cascade impactor, and 34% for an eight-stage Andersen impactor. An approach is given to calculate the committed effective dose (CED) coefficient for PuO2 aerosol particles, compared to a corresponding aerodynamic diameter of CeO2 particles. With this approach, use of CeO2 as a surrogate for PuO2 material would follow a direct conversion based on a molar equivalent. In addition to the analytical information developed for this document, several US national labs have published articles about the use of CeO2 as a PuO2 surrogate. Different physical and chemical aspects were considered by these investigators, including thermal properties, ceramic formulations, cold pressing, sintering, molecular reactions, and mass loss in high temperature gas flows. All of those US national lab studies recommended the use of CeO2 as a surrogate material for PuO2.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ponderomotive self-focusing of Gaussian laser beam in warm collisional plasma

The propagation characteristics of a Gaussian laser beam through warm collisional plasma are investigated by considering the ponderomotive force nonlinearity and the complex eikonal function. By introducing the dielectric permittivity of warm unmagnetized plasma and using the WKB and paraxial ray approximations, the coupled differential equations defining the variations of laser beam parameters are obtained and solved numerically. Effects of laser and plasma parameters such as the collision frequency, the initial laser intensity and its spot size on the beam width parameter and the axis laser intensity distribution are analyzed. It is shown that, self-focusing of the laser beam takes place faster by increasing the collision frequency and initial laser spot size and then after some distance propagation the laser beam abruptly loses its initial diameter and vastly diverges. Furthermore, the modified electron density distribution is obtained and the collision frequency effect on this distribution is studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl{sub 2} and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact of such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm{sup 3} (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.

60 APPLIED LIFE SCIENCES↗

Pore system characterization of organic-rich shales using nanoscale-resolution 3D imaging

The Vaca Muerta Shale in Argentina is the first signifcant commercial shale oil/gas play outside of North America. High-resolution 2D/3D imaging of shale rocks for the purpose of establishing their mineralogy, total, and connected porosities has become more and more sophisticated. In this paper, nanoscale-resolution focused ion beam (FIB)-scanning electron microscopy (SEM) nano-tomography was used to obtain images of pore structures within two organic-rich regions of interest (ROIs), selected based on correlative SEM and automated mineralogy maps. Advanced machine learning classification tools were used to segment the images and assign porosities and other components. Pore size distribution and pore connectivity analyzes revealed that about 95% of all the pores, present within the two ROIs, had a diameter of less than approximately 75 nm, and that most of these pores were poorly connected. In a similar fashion, the flow rate distribution analysis showed that pores with diameters of about 150-330 nm contributed to over 50% of the flow capacity of the connected pore systems. These results suggest that although most of the pores typically found in shales have pore diameter smaller than about 100 nm, most of the hydrocarbon production may be carried by a relatively small number of larger connected pores with pore diameter greater than about 150 nm. This research implies that a large portion of the organic-hosted pores (with diameter typically smaller than about 100 nm) may not provide permeable flow pathways for the oil and/or gas migration, and hence may have very little contribution to the hydrocarbon production.

58 GEOSCIENCES↗

Gas phase synthesis of non-bundled, small diameter single-walled carbon nanotubes with near-armchair chiralities

We present a floating catalyst synthesis route for individual, i.e., non-bundled, small diameter single-walled carbon nanotubes (SWCNTs) with a narrow chiral angle distribution peaking at high chiralities near the armchair species. An ex situ spark discharge generator was used to form iron particles with geometric number mean diameters of 3–4 nm and fed into a laminar flow chemical vapour deposition reactor for the continuous synthesis of long and high-quality SWCNTs from ambient pressure carbon monoxide. The intensity ratio of G/D peaks in Raman spectra up to 48 and mean tube lengths up to 4 μm were observed. The chiral distributions, as directly determined by electron diffraction in the transmission electron microscope, clustered around the (n,m) indices (7,6), (8,6), (8,7), and (9,6), with up to 70% of tubes having chiral angles over 20°. The mean diameter of SWCNTs was reduced from 1.10 to 1.04 nm by decreasing the growth temperature from 880 to 750 °C, which simultaneously increased the fraction of semiconducting tubes from 67% to 80%. Limiting the nanotube gas phase number concentration to ∼10{sup 5 }cm{sup −3} prevented nanotube bundle formation that is due to collisions induced by Brownian diffusion. Up to 80% of 500 as-deposited tubes observed by atomic force and transmission electron microscopy were individual. Transparent conducting films deposited from these SWCNTs exhibited record low sheet resistances of 63 Ω/□ at 90% transparency for 550 nm light.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel Asynchronous Distributed-Memory Maximal Independent Set Algorithm with Work Ordering

The maximal independent set (MIS) graph problem arises in many applications such as computer vision, information theory, molecular biology, and process scheduling. The growing scale of graph data suggests the use of distributed memory hardware as a cost-effective approach to providing necessary compute and memory resources. Existing distributed memory parallel MIS algorithms rely on synchronous communication and use techniques such as subgraph computations. In this paper, we present an asynchronous distributed-memory parallel graph algorithm that relies on a virtual directed acyclic graph (DAG) that is created during the algorithm execution. We introduce two additional algorithms that save computations by ordering generated work. The first algorithm applies ordering globally to reduce computations, and the second algorithm applies ordering locally at the level of threads to minimize the synchronization overhead. We use two different implementations of Luby’s algorithm variants as baseline to compare the performance of the presented algorithms: (1) vertex-centric Luby A and Luby B implementations, and (2) the CombBLAS linear-algebra Luby A implementation. Results show that proposed algorithms outperform both implementations of Luby algorithms, especially in distributed execution. Furthermore, we show that for low-diameter graphs the algorithm that applies global ordering scales better than other algorithms and for high diameter graphs the original asynchronous algorithm and thread-level ordering algorithm show better performance.

maximal independent set (MIS), distributed memory ↗

On the definition of crater saturation diameter

A theoretical model is developed for determining the diameter D sub p such that the density of lunar craters exceeding D sub p constitutes a specified proportion p of the maximum number that could be observed on a crater-saturated surface. It is shown that this diameter is sensitive to the value of the exponent in the fresh crater size distribution, and is much more informative than usual log-log plot intercept definition of satureation diameter.

Marcus, A. H.↗

Clustering, randomness, and regularity in cloud fields. 4: Stratocumulus cloud fields

To complete the analysis of the spatial distribution of boundary layer cloudiness, the present study focuses on nine stratocumulus Landsat scenes. The results indicate many similarities between stratocumulus and cumulus spatial distributions. Most notably, at full spatial resolution all scenes exhibit a decidedly clustered distribution. The strength of the clustering signal decreases with increasing cloud size; the clusters themselves consist of a few clouds (less than 10), occupy a small percentage of the cloud field area (less than 5%), contain between 20% and 60% of the cloud field population, and are randomly located within the scene. In contrast, stratocumulus in almost every respect are more strongly clustered than are cumulus cloud fields. For instance, stratocumulus clusters contain more clouds per cluster, occupy a larger percentage of the total area, and have a larger percentage of clouds participating in clusters than the corresponding cumulus examples. To investigate clustering at intermediate spatial scales, the local dimensionality statistic is introduced. Results obtained from this statistic provide the first direct evidence for regularity among large (more than 900 m in diameter) clouds in stratocumulus and cumulus cloud fields, in support of the inhibition hypothesis of Ramirez and Bras (1990). Also, the size compensated point-to-cloud cumulative distribution function statistic is found to be necessary to obtain a consistent description of stratocumulus cloud distributions. A hypothesis regarding the underlying physical mechanisms responsible for cloud clustering is presented. It is suggested that cloud clusters often arise from 4 to 10 triggering events localized within regions less than 2 km in diameter and randomly distributed within the cloud field. As the size of the cloud surpasses the scale of the triggering region, the clustering signal weakens and the larger cloud locations become more random.

Lee, J.↗

Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are larger and more common in volumes with high microsphere concentrations and indicate that the spatial distribution of the artery tree must be considered in estimates of microsphere distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗

SU-F-T-129: Impact of Radial Fluctuations in RBE for Therapeutic Proton Beams

Purpose: To evaluate the off axis relative biological effectiveness (RBE) for actively scanned proton beams and determine if a constant radial RBE can be assumed. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary protons were simulated for a 0.6cm diameter pencil beam. Beam energies corresponding to Bragg Peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially for annuli of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm outer radius. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model, for human submandibular gland (HSG) cells, to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. Results: RBE was generally seen to increase as distance from the central axis (CAX) increased. However, this increase was only seen in low dose regions and its overall effects on the transverse biological dose remains low. In the entrance region of the phantom (10mm depth), minimum and maximum calculated RBEs varied between 15.22 and 18.88% for different energies. At the Bragg peak, this difference ranged from 3.15 to 26.77%. Despite these rather large variations the dose-weighted RBE and the CAX RBE varied by less than 0.14% at 10mm depth and less than 0.16% at the Bragg peak. Similarly small variations were found at all depths proximal of the Bragg peak. Conclusion: Although proton RBE does vary radially, its overall effect on biological dose is minimal and the use of a radially constant RBE in treatment planning for scanned proton beams would not produce large errors.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-09: Application of a Modified Microdosimetric-Kinetic Model to Analyze Relative Biological Effectiveness of Ions Relevant to Light Ion Therapy Using the Particle Heavy Ion Transport System

Purpose: To evaluate the dose and biological effectiveness of various ions that could potentially be used for actively scanned particle therapy. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary particles for 1H beams and ten million particles for 4He, 7Li, 10B, 12C, 14N, 16O, and 20Ne were simulated for 0.6cm diameter pencil beams. Beam energies corresponding to Bragg peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially in annuli with outer radius of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model for five different cell types to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. The product of the calculated RBEs and the simulated physical dose was taken to create biological dose and comparisons were then made between the various ions. Results: Transversely, the 10B beam was seen to minimize relative biological dose in both the constant and accelerated dose change regions, proximal to the Bragg Peak, for all beams traveling greater than 50mm. For the 50mm beam, 7Li was seen to provide the most optimal biological dose profile. Radially small fluctuations (<4.2%) were seen in RBE while physical dose was greater than 1% for all beams. Conclusion: Even with the growing usage of 12C, it may not be the most optimal ion in all clinical situations. Boron was calculated to have slightly enhanced RBE characteristics, leading to lower relative biological doses.

60 APPLIED LIFE SCIENCES↗

Distribution, Statistics, and Resurfacing of Large Impact Basins on Mercury

The distribution and geological history of large impact basins (diameter D greater than or equal to 300 km) on Mercury is important to understanding the planet's stratigraphy and surface evolution. It is also informative to compare the density of impact basins on Mercury with that of the Moon to understand similarities and differences in their impact crater and basin populations [1, 2]. A variety of impact basins were proposed on the basis of geological mapping with Mariner 10 data [e.g. 3]. This basin population can now be re-assessed and extended to the full planet, using data from the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. Note that small-to- medium-sized peak-ring basins on Mercury are being examined separately [4, 5]; only the three largest peak-ring basins on Mercury overlap with the size range we consider here. In this study, we (1) re-examine the large basins suggested on the basis of Mariner 10 data, (2) suggest additional basins from MESSENGER's global coverage of Mercury, (3) assess the size-frequency distribution of mercurian basins on the basis of these global observations and compare it to the Moon, and (4) analyze the implications of these observations for the modification history of basins on Mercury.

Fassett, Caleb I.↗