Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

ORNL Portable Diagnostic Package for Evaluating Mirror Performance

Oak Ridge National Laboratory (ORNL) and Realta Fusion successfully executed a one-year collaborative effort to deploy the Portable Diagnostic Package (PDP) on the Wisconsin HTS Axisymmetric Mirror (WHAM) and to assess future diagnostic needs. The PDP consists of an optical emission spectroscopy (OES) subsystem and a Thomson scattering (TS) subsystem. Within the first two months, the PDP OES subsystem was installed, integrated with WHAM timing, and handed over to trained Realta personnel. It immediately delivered multi-channel impurity surveys and the first spatially resolved plasma-rotation profiles inferred from C III Doppler shifts. The TS subsystem was commissioned within the first six months; transportation of the class IV laser system, approval of the safety plan, and the integration with WHAM timing with 100 ns resolution. The TS subsystem provided the first localized electron temperature measurements in WHAM commissioning shots. Leveraging these results, the team has discussed a diagnostic concept map for Realta’s next-step facility, Anvil, identifying line-of-sight constraints, required temporal resolution, and hardware upgrades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion diagnostics and physics at MAST-Upgrade (Final Report)

The main contribution of UCI personnel to MAST-U was installation of the solid-state neutral particle analyzer (SSNPA) diagnostic, which was documented in a 2022 Review of Scientific Instruments article by UCI PhD student Garrett Prechel. Another paper by PI William Heidbrink et al supplied a helpful tool for analysis of the data from the 3 MeV proton diagnostic [Plasma Phys. Cont. Fusion, 2021]. Useful advice was also given concerning the FIDA diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The National Diagnostic Plan (NDP) for HED Science September 2025

This documents the National Diagnostic Plan as of September 2025. The major changes in this version compared to the NDP document issued in 2024 are the new schedules and the text for the national transformative diagnostics - section III. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA are also updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Completion document for MRT 8824 - Upgrade NIF’s gaseous radiochemistry diagnostics (RAGS) to support weapons science

This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spin Diagnostics Using Mott Polarimeter for the EIC Pre-Injector

Polarization measurement and front-end commissioning are critical steps in the EIC preinjector program. We designed a spin-diagnostics beamline at around 4 MeV for front-end commissioning. This paper describes a high-energy Mott polarimeter, including Mott scattering, the Sherman function, and extrapolation toward single elastic scattering in finite-thickness foils. We summarize the key equations used to calculate essential design parameters, including detection time, effective Sherman function, differential cross section, and Mott polarimeter figure of merit. We also present the diagnostics beamline lattice design and kicker design for continuous spin-polarization monitoring. These notes provide concepts, formulas, and methods for diagnostic-beamline design and commissioning measurements.

43 PARTICLE ACCELERATORS↗

Magnetic Diagnostics for the Lithium Tokamak eXperiment

The Lithium Tokamak eXperiment (LTX) is a spherical tokamak with R0 = 0.4m, a = 0.26m, BTF ~ 3.4kG, IP ~ 400kA, and pulse length ~ 0.25s. The focus of LTX is to investigate the novel, low-recycling Lithium Wall operating regime for magnetically confined plasmas. This regime is reached by placing an in-vessel shell conformal to the plasma last closed flux surface. The shell is heated and then coated with liquid lithium. An extensive array of magnetic diagnostics is available to characterize the experiment, including 80 Mirnov coils (single and double-axis, internal and external to the shell), 34 flux loops, 3 Rogowskii coils, and a diamagnetic loop. Diagnostics are specifically located to account for the presence of a secondary conducting surface and engineered to withstand both high temperatures and incidental contact with liquid lithium. The diagnostic set is therefore fabricated from robust materials with heat and lithium resistance and is designed for electrical isolation from the shell and to provide the data required for highly constrained equilibrium reconstructions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among all the team members. Fortunately, the project team performed exceptionally well together and was able to work through the various challenges that this presented - for example, when one software tool required a detailed description of the output of a second tool, before that tool had been fully designed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of backlighting sources for a Compton Radiography diagnostic of Inertial Confinement Fusion targets

An important diagnostic tool for inertial confinement fusion is time-resolved imaging of the dense cold fuel surrounding the hot spot. Here we report on the source and diagnostic development of hard x-ray radiography and on the first radiographs of direct drive implosions obtained at photon energies up to about 100keV, where the Compton effect is the dominant contributor to the shell opacity. The radiographs of direct drive, plastic shell implosions obtained at the OMEGA laser facility have a spatial resolution of {approx}10um and a temporal resolution of {approx}10ps. This novel Compton Radiography is an invaluable diagnostic tool for Inertial Confinement Fusion targets, and will be integrated at the National Ignition Facility (NIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of advanced laser diagnostics to hypersonic wind tunnels and combustion systems.

This LDRD was a Sandia Fellowship that supported Andrea Hsu's PhD research at Texas A&M University and her work as a visitor at Sandia's Combustion Research Facility. The research project at Texas A&M University is concerned with the experimental characterization of hypersonic (Mach>5) flowfields using experimental diagnostics. This effort is part of a Multidisciplinary University Research Initiative (MURI) and is a collaboration between the Chemistry and Aerospace Engineering departments. Hypersonic flight conditions often lead to a non-thermochemical equilibrium (NTE) state of air, where the timescale of reaching a single (equilibrium) Boltzmann temperature is much longer than the timescale of the flow. Certain molecular modes, such as vibrational modes, may be much more excited than the translational or rotational modes of the molecule, leading to thermal-nonequilibrium. A nontrivial amount of energy is therefore contained within the vibrational mode, and this energy cascades into the flow as thermal energy, affecting flow properties through vibrational-vibrational (V-V) and vibrational-translational (V-T) energy exchanges between the flow species. The research is a fundamental experimental study of these NTE systems and involves the application of advanced laser and optical diagnostics towards hypersonic flowfields. The research is broken down into two main categories: the application and adaptation of existing laser and optical techniques towards characterization of NTE, and the development of new molecular tagging velocimetry techniques which have been demonstrated in an underexpanded jet flowfield, but may be extended towards a variety of flowfields. In addition, Andrea's work at Sandia National Labs involved the application of advanced laser diagnostics to flames and turbulent non-reacting jets. These studies included quench-free planar laser-induced fluorescence measurements of nitric oxide (NO) and mixture fraction measurements via Rayleigh scattering.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Associations between diagnostic patterns and stages in ovarian cancer

Ovarian cancer (OvCa) is the fifth leading cause of cancer deaths in women and remains the most deadly gynecological cancer. The disease places a debilitating burden on the US population, in terms of mortality, morbidity, individual suffering and loss of productivity for all women with OvCa. National expenditures for OvCa care were estimated at $5.12B in 2010. The high fatality of OvCa is attributed to the fact that most patients are diagnosed at a late stage, with 63% diagnosed at Stage III or later. Effective early-stage diagnosis is challenging because there are no approved screening procedures for the general population, which has led to OvCa being termed1 the “silent killer”. We have previously shown that public awareness and knowledge about OvCa is poor among the general population. It has also been reported that ovarian masses have often been misdiagnosed, although there was some association of pre-diagnostic symptoms with OvCa and with OvCa diagnostic stages. The motivation for the current study was to examine the association of diagnostic patterns (determined by the responses from ‘frontline’ clinicians, specifically primary care physicians (PCPs) and emergency room (ER) doctors, together with follow-up by specialists), with OvCa stages.

60 APPLIED LIFE SCIENCES↗

Virtual Diagnostic Suite for Electron Beam Prediction and Control at FACET-II

We discuss the implementation of a suite of virtual diagnostics at the FACET-II facility currently under commissioning at SLAC National Accelerator Laboratory. The diagnostics will be used for the prediction of the longitudinal phase space along the linac, spectral reconstruction of the bunch profile, and non-destructive inference of transverse beam quality (emittance) while using edge radiation at the injector dogleg and bunch compressor locations. These measurements will be folded into adaptive feedbacks and Machine Learning (ML)-based reinforcement learning controls to improve the stability and optimize the performance of the machine for different experimental configurations. In this paper we describe each of these diagnostics with expected measurement results that are based on simulation data and discuss progress towards implementation in regular operations.

Emma, Claudio (ORCID:0000000247191831)↗

Luminosity dependence and redshift evolution of strong emission-line diagnostics in star-forming galaxies

We examine the redshift evolution of standard strong emission-line diagnostics for Hβ-selected star-forming galaxies using the local SDSS sample and a new z=0.2--2.3 sample obtained from Hubble Space Telescope WFC3 grism and Keck DEIMOS and MOSFIRE data. We use the SDSS galaxies to show that there is a systematic dependence of the strong emission-line properties on Balmer-line luminosity, which we interpret as showing that both the N/O abundance and the ionization parameter increase with increasing line luminosity. Allowing for the luminosity dependence tightens the diagnostic diagrams and the metallicity calibrations. The combined SDSS and high-redshift samples show that there is no redshift evolution in the line properties once the luminosity correction is applied, i.e., all galaxies with a given L(Hβ) have similar strong emission-line distributions at all the observed redshifts. We argue that the best metal diagnostic for the high-redshift galaxies may be a luminosity-adjusted version of the [N ii]6584/Hα metallicity relation.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Calibrations of Fe xii–xiv Line-Intensity Ratios for Electron Density Diagnostics

In this work, we have used an electron beam ion trap to measure electron-density-diagnostic line-intensity ratios for extreme ultraviolet lines from Fe xii, xiii, and xiv at wavelengths of ≈185–205 and 255–276 Å. These ratios can be used as density diagnostics for astrophysical spectra and are especially relevant to solar physics. We found that density diagnostics using the Fe xiii 196.53/202.04 and the Fe xiv 264.79/274.21 and 270.52A/274.21 line ratios are reliable using the atomic data calculated with the Flexible Atomic Code (FAC). On the other hand, we found a large discrepancy between the FAC theory and experiment for the commonly used Fe xii (186.85 + 186.88)/195.12 line ratio. These FAC theory calculations give results similar to the data tabulated in CHIANTI, which are commonly used to analyze solar observations. Our results suggest that the discrepancies seen between solar coronal density measurements using the Fe xii (186.85 + 186.88)/195.12 and Fe xiii 196.54/202.04 line ratios are likely due to issues with the atomic calculations for Fe xii.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Low-redshift Lyman Continuum Survey. II. New Insights into LyC Diagnostics

The Lyman continuum (LyC) cannot be observed at the epoch of reionization (z ≳ 6) owing to intergalactic H I absorption. To identify LyC emitters (LCEs) and infer the fraction of escaping LyC, astronomers have developed various indirect diagnostics of LyC escape. Using measurements of the LyC from the Low-redshift Lyman Continuum Survey (LzLCS), we present the first statistical test of these diagnostics. While optical depth indicators based on Lyα, such as peak velocity separation and equivalent width, perform well, we also find that other diagnostics, such as the [O III ]/[O II ] flux ratio and star formation rate surface density, predict whether a galaxy is an LCE. The relationship between these galaxy properties and the fraction of escaping LyC flux suggests that LyC escape depends strongly on H I column density, ionization parameter, and stellar feedback. We find that LCEs occupy a range of stellar masses, metallicities, star formation histories, and ionization parameters, which may indicate episodic and/or different physical causes of LyC escape.

79 ASTRONOMY AND ASTROPHYSICS↗

Earth System Model Aerosol–Cloud Diagnostics (ESMAC Diags) package, version 2: assessing aerosols, clouds, and aerosol–cloud interactions via field campaign and long-term observations

Abstract. Poor representations of aerosols, clouds, and aerosol–cloud interactions (ACIs) in Earth system models (ESMs) have long been the largest uncertainties in predicting global climate change. Huge efforts have been made to improve the representation of these processes in ESMs, and the key to these efforts is the evaluation of ESM simulations with observations. Most well-established ESM diagnostics packages focus on the climatological features; however, they lack process-level understanding and representations of aerosols, clouds, and ACIs. In this study, we developed the Earth System Model Aerosol–Cloud Diagnostics (ESMAC Diags) package to facilitate the routine evaluation of aerosols, clouds, and ACIs simulated the Energy Exascale Earth System Model (E3SM) from the US Department of Energy (DOE). This paper documents its version 2 functionality (ESMAC Diags v2), which has substantial updates compared with version 1 (Tang et al., 2022a). The simulated aerosol and cloud properties have been extensively compared with in situ and remote-sensing measurements from aircraft, ship, surface, and satellite platforms in ESMAC Diags v2. It currently includes six field campaigns and two permanent sites covering four geographical regions: the eastern North Atlantic, the central US, the northeastern Pacific, and the Southern Ocean. These regions produce frequent liquid- or mixed-phase clouds, with extensive measurements available from the DOE Atmospheric Radiation Measurement user facility and other agencies. ESMAC Diags v2 generates various types of single-variable and multivariable diagnostics, including percentiles, histograms, joint histograms, and heatmaps, to evaluate the model representation of aerosols, clouds, and ACIs. Select examples highlighting the capabilities of ESMAC Diags are shown using E3SM version 2 (E3SMv2). In general, E3SMv2 can reasonably reproduce many observed aerosol and cloud properties, with biases in some variables such as aerosol particle and cloud droplet sizes and number concentrations. The coupling of aerosol and cloud number concentrations may be too strong in E3SMv2, possibly indicating a bias in processes that control aerosol activation. Furthermore, the liquid water path response to a perturbed cloud droplet number concentration behaves differently in E3SMv2 and observations, which warrants further study to improve the cloud microphysics parameterizations in E3SMv2.

54 ENVIRONMENTAL SCIENCES↗

ESMValTool (v1.0) – a community diagnostic and performance metrics tool for routine evaluation of Earth system models in CMIP

A community diagnostics and performance metrics tool for the evaluation of Earth system models (ESMs) has been developed that allows for routine comparison of single or multiple models, either against predecessor versions or against observations. The priority of the effort so far has been to target specific scientific themes focusing on selected essential climate variables (ECVs), a range of known systematic biases common to ESMs, such as coupled tropical climate variability, monsoons, Southern Ocean processes, continental dry biases, and soil hydrology–climate interactions, as well as atmospheric CO 2 budgets, tropospheric and stratospheric ozone, and tropospheric aerosols. The tool is being developed in such a way that additional analyses can easily be added. A set of standard namelists for each scientific topic reproduces specific sets of diagnostics or performance metrics that have demonstrated their importance in ESM evaluation in the peer-reviewed literature. The Earth System Model Evaluation Tool (ESMValTool) is a community effort open to both users and developers encouraging open exchange of diagnostic source code and evaluation results from the Coupled Model Intercomparison Project (CMIP) ensemble. This will facilitate and improve ESM evaluation beyond the state-of-the-art and aims at supporting such activities within CMIP and at individual modelling centres. Ultimately, we envisage running the ESMValTool alongside the Earth System Grid Federation (ESGF) as part of a more routine evaluation of CMIP model simulations while utilizing observations available in standard formats (obs4MIPs) or provided by the user.

58 GEOSCIENCES↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities. (2016-06-06)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗